Asus GIGAX 2024M Cli Manual

GigaX2024B/M CLI Manual Layer 2 Managed Switch
E2644 May 2006 V1 No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUST eK COMPUTER INC. (ASUS). Product warranty or service will not be extended if: (1) the product is repaired, modied or altered, unless such repair , modication of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing. ASUS provides this manual “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties or conditions of merchantability or tness for a particular purpose. In no event shall ASUS, its directors, ofcers, employees, or agents be liable for any indirect, special, incidental, or consequential damages (including damages for loss of prots, loss of business, loss of use or data, interruption of business and the like), even if ASUS has been advised of the possibility of such damages arising from any defect or error in this manual or product. Specications and information contained in this manual are furnished for informational use only , and are subject to change at any time without notice, and should not be construed as a commitment by ASUS. ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual, including the products and software described in it. Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identication or explanation and to the owners’ benet, without intent to infringe. Copyright © 2006 ASUST eK COMPUTER INC. All Rights Reserved.
i T able of content CLI Command Modes ................................................................. 1 1 IGMP ......................................................................................... 2 1.1 ip igmp snooping .............................................................................. 2 1.2 ip igmp snooping last-member-query-interval TIMEV ALUE ............. 2 1.3 ip igmp snooping vlan <1-3000> ...................................................... 3 1.4 ip igmp snooping vlan <1-3000> immediate-leave .................................. 3 1.5 show ip igmp snooping .................................................................... 4 1.6 show ip igmp snooping vlan <1-3000> ............................................ 4 2. LACP: ....................................................................................... 5 2.1 lacp aggregation-link group <1-32> (add|set) IFLIST ...................... 5 2.2 lacp aggregation-link group delete IFNAME .................................... 5 2.3 lacp system-priority <1-65535> ........................................................ 6 2.4 show lacp [GROUPID] ..................................................................... 6 3. Static Link Aggregation ......................................................... 7 3.1 aggregation-link group <1-32> PORTLIST ...................................... 7 3.2 aggregation-link group <1-32> load-balance (src-mac |dst-mac |src- dst-mac |src-ip |dst-ip |src-dst-ip) ..................................................... 7 3.3 show aggregation-link group [GROUPID] ........................................ 8 4. GVRP ....................................................................................... 8 4.1 clear gvrp statistics [IFNAME] .......................................................... 8 4.2 gvrp (enable|disable) ...................................................................... 9 4.3 gvrp (enable|disable) ...................................................................... 9 4.4 gvrp registration (normal|xed|forbidden) ..................................... 10 4.5 show gvrp ...................................................................................... 10 4.6 show gvrp statistics [IFNAME] ....................................................... 10
ii 4.7 show gvrp interface IFNAME .........................................................1 1 4.8 garp join-timer <1-100000000> ....................................................... 1 1 4.9 garp leaveall-timer <1-100000000> ................................................ 1 1 4.10 garp leave-timer <1-100000000> ................................................... 12 4.1 1 show garp timer IFNAME ............................................................... 12 5. VLAN: ..................................................................................... 13 5.1 show vlan name VLANAME ........................................................... 13 5.2 vlan <2-3000> ................................................................................ 13 5.3 show vlan [VLANID] ....................................................................... 13 5.4 name VLANAME ............................................................................ 14 5.5 switchport access vlan <1-3000> ................................................... 14 5.6 switchport mode (access|trunk) ..................................................... 14 5.7 switchport trunk native vlan <1-3000> ........................................... 15 5.8 switchport trunk allowed vlan (add|remove) VLANLIST ................. 15 6. 802.1x: ................................................................................... 16 6.1 dot1x guest-vlan <1-3000> ............................................................ 16 6.2 dot1x max-req <1-10> .................................................................... 16 6.3 dot1x port-control (auto|force-authorized| force-unauthorized) ...... 17 6.4 dot1x radius server A.B.C.D RADIUS_KEY [POR TID] .................. 18 6.5 dot1x radius secondary-server A.B.C.D RADIUS_KEY [POR TID] . 18 6.6 dot1x re-authenticate interface [IFNAME] ...................................... 19 6.7 dot1x reauthentication .................................................................... 19 6.8 dot1x system-auth-control .............................................................. 19 6.9 dot1x timeout (reauth-period| quiet-period|tx-period| supp-timeout| server-timeout) TIMEV ALUE .......................................................... 20 6.10 dot1x host-mode (multi-host| single-host) ...................................... 21 6.1 1 dot1x authentic-method (local | radius) .......................................... 21 6.12 dot1x user WORD P ASSWORD <1-3000> .................................... 21 6.13 show dot1x ..................................................................................... 22 6.14 show dot1x interface IFNAME ....................................................... 22
iii 6.15 show dot1x radius .......................................................................... 23 6.16 show dot1x user ................................................................................. 23 7. Mirror ..................................................................................... 23 7.1 mirror session <1-8> destination IFNAME ..................................... 23 7.2 mirror session <1-8> source IFLIST (rx|tx|both)) ........................... 24 7.3 show mirror session ....................................................................... 24 7.4 no mirror session <1-8> source IFLIST ......................................... 25 8. QoS/CoS ................................................................................ 25 8.1 cos cos-map PRIORITY QUEUE ................................................... 25 8.2 show cos cos-map ......................................................................... 25 8.3 cos policy wrr-queue weight <1-10> <1-10> <1-10> <1-10> <1-10> <1-10> ........................................................................................... 26 8.4 cos policy strict ............................................................................... 26 8.5 show cos policy .............................................................................. 27 8.6 show qos egress bandwidth [IFNAME] .......................................... 27 8.7 show qos Ingress bandwidth [IFNAME] ......................................... 28 8.8 qos egress bandwidth <1-1000> .................................................... 28 8.9 no qos egress bandwidth ............................................................... 28 8.10 qos ingress bandwidth <1-1000> ................................................... 29 8.1 1 no qos ingress bandwidth .............................................................. 29 8.12 cos policy fo ................................................................................. 30 8.13 no cos policy ................................................................................. 30 9. Storm control ........................................................................ 30 9.1 storm-control (broadcast|dlf|multicast) <1-262143> ....................... 30 9.2 no storm-control (broadcast|dlf|multicast) ...................................... 31 9.3 show storm-control (broadcast|dlf|multicast) .................................. 32 10. MAC address management Conguration: ...................... 32 10.1 clear mac-address-table dynamic vlan <1-3000> .......................... 32 10.2 mac-address-table aging-time TIMEV ALUE .................................. 33 10.3 no mac-address-table aging-time .................................................. 33
iv 10.4 show mac-address-table aging-time .............................................. 34 10.5 mac-address-table static MACADDR VLANID IFNAME ................ 34 10.6 mac-address-table multicast MACADDR vlan VLANID interface IFLIST COS_DEST ........................................................................ 35 10.7 no mac-address-table multicast MACADDR vlan VLANID interface IFLIST COS_DEST ........................................................................ 35 10.8 show mac-address-table multicast ................................................. 36 10.9 show mac-address-table static mac [MAC_ADDR] ....................... 37 10.10 show mac-address-table static interface [IFNAME] ....................... 37 10.1 1 show mac-address-table static vlan [VLANID] ............................... 37 10.12 show mac-address-table static ..................................................... 38 10.13 show mac-address-table ............................................................... 38 10.14 show mac-address-table multicast MACADDR vlan VLANID ........ 38 10.15 show mac-address-table dynamic ................................................ 39 10.16 show mac-address-table dynamic interface [IFNAME] .................. 39 10.17 show mac-address-table dynamic mac [MAC_ADDR] .................. 39 10.18 show mac-address-table dynamic vlan [VLANID] .......................... 40 10.19 clear mac-address-table mac MAC_ADDR ................................... 40 10.20 clear mac-address-table dynamic .................................................. 40 10.21 clear mac-address-table dynamic interface IFNAME ..................... 41 10.22 clear mac-address-table dynamic vlan VLANID ............................ 41 10.23 clear mac-address-table interface IFNAME ................................... 42 10.24 clear mac-address-table multicast MACADDR VLANID ................ 42 10.25 clear mac-address-table vlan VLANID ........................................... 43 10.26 show spanning-tree summary ............................................................ 43 10.27 show spanning-tree interface [IFNAME] ............................................ 43 10.28 spanning-tree (enable|disable) ...................................................... 44 10.29 spanning-tree cost <1-200000000> ............................................... 44 10.30 spanning-tree edge-port ................................................................. 44
v 10.31 spanning-tree forward-time <4-30> ................................................ 45 10.32 spanning-tree hello time <1-10> .................................................... 45 10.33 spanning-tree link-type (auto|point-to-point|shared) ...................... 46 10.34 spanning-tree max-age <6-40> ...................................................... 46 10.35 spanning-tree port-priority <0-240> ............................................... 47 10.36 spanning-tree priority <0-61440> ................................................... 47 10.37 spanning-tree transmission-limit <1-10> ........................................ 48 10.38 spanning-tree mode (pvst|rapid-pvst) ............................................ 48 10.39 spanning-tree uplink-fast ................................................................ 49 10.40 spanning-tree algorithm-timer <4-30> <6-40> <1-10> ................... 49 10.41 spanning-tree bpdu-guard (enable|disable) ................................... 49 10.42 spanning-tree mst max-hops [1-40] ............................................... 50 10.43 no spanning-tree mst max-hops .................................................... 50 10.44 show spanning-tree mst ................................................................. 50 10.45 show spanning-tree mst conguration ........................................... 51 10.46 show spanning-tree mst <1-15> .................................................... 51 10.47 show spanning-tree mst instance [1-15] interface [IF Name] ......... 51 10.48 spanning-tree mode mst ................................................................ 52 10.49 spanning-tree mst revision <0-65535> .......................................... 52 10.50 no spanning-tree mst name ........................................................... 52 10.51 spanning-tree mst name [NAME] ................................................... 53 10.52 no spanning-tree mst instance [msti] ............................................. 53 10.53 spanning-tree mst instance [msti] vlan [vids] ................................. 53 10.54 spanning-tree mst [mstis] cost [value] .......................................... 53 10.55 spanning-tree mst [mstis] port-priority [value] .............................. 54 1 1. SNMP ................................................................................... 54 1 1.1 show rmon statistics [IFNAME] ...................................................... 55 1 1.2 show rmon statistics stack <1-8> ................................................... 55 1 1.3 show snmp-server community ....................................................... 55
vi 1 1.4 show snmp-server community network .......................................... 56 1 1.5 show snmp-server contact ............................................................. 56 1 1.6 show snmp-server host .................................................................. 56 1 1.7 show snmp-server location ............................................................ 57 1 1.8 show snmp-server trap community ................................................ 57 1 1.9 snmp-server community trap WORD ............................................. 57 1 1.10 snmp-server community WORD (ro/rw) network A.B.C.D/MASK .. 58 1 1.1 1 snmp-server contact DWORD ....................................................... 58 1 1.12 snmp-server host A.B.C.D ............................................................. 59 1 1.13 snmp-server location DWORD ....................................................... 59 1 1.14 snmp-server user WORD WORD v3 noauth ................................. 60 1 1.15 snmp-server user WORD WORD v3 auth (md5|sha) WORD ........ 60 1 1.16 snmp-server user WORD WORD v3 priv (md5|sha) WORD des WORD ............................................................................................ 61 1 1.17 snmp-server group WORD v3 WORD ........................................... 62 1 1.18 snmp-server group WORD v3 noauth ............................................ 62 1 1.19 snmp-server group WORD v3 noauth read WORD ....................... 63 1 1.20 snmp-server group WORD v3 noauth read WORD write WORD .. 63 1 1.21 snmp-server group WORD v3 noauth read WORD write WORD notify WORD .................................................................................. 64 1 1.22 snmp-server group WORD v3 auth ................................................ 65 1 1.23 snmp-server group WORD v3 auth read WORD ........................... 66 1 1.24 snmp-server group WORD v3 auth read WORD write WORD ...... 66 1 1.25 snmp-server group WORD v3 auth read WORD write WORD notify WORD ............................................................................................ 67 1 1.26 snmp-server group WORD v3 priv ................................................. 68 1 1.27 snmp-server group WORD v3 priv read WORD ............................ 69 1 1.28 snmp-server group WORD v3 priv read WORD write WORD ....... 69 1 1.29 snmp-server group WORD v3 priv read WORD write WORD notify WORD ............................................................................................ 70 1 1.30 snmp-server view WORD WORD (included|excluded) .................. 71
vii 1 1.31 show snmp-server view ................................................................. 72 1 1.32 show snmp-server group ............................................................... 72 1 1.33 show snmp-server user .................................................................. 72 1 1.34 snmp-server host A.B.C.D version (1|2) [COMMUNITY] ............... 73 1 1.35 no snmp-server community trap ................................................... 73 1 1.36 show rmon alarms .......................................................................... 73 1 1.37 show rmon events .......................................................................... 74 1 1.38 show rmon history .......................................................................... 74 1 1.39 rmon alarm <1-65536> O ID <1-42949 67295> (abs olute|delta ) rising- threshold V ALUE <1-65535> falling-threshold V ALUE <1-65535> [OWNER] ....................................................................................... 74 1 1.40 rmon alarm <1-65536> O ID <1-42949 67295> (abs olute|delta ) rising- threshold V ALUE <1-65535> falling-threshold V ALUE [OWNER] 75 1 1.41 rmon alarm <1-65536> O ID <1-42949 67295> (abs olute|delta ) rising- threshold V ALUE falling-threshold V ALUE <1-65535> [OWNER].. 76 1 1.42 rmon alarm <1-65536> O ID <1-42949 67295> (abs olute|delta ) rising- threshold V ALUE falling-threshold V ALUE [OWNER] .................... 77 1 1.43 rmon event <1-65536> description NAME [OWNER] .................... 78 1 1.44 rmon event <1-65536> description NAME log [OWNER] .............. 78 1 1.45 rmon event <1-65536> description NAME trap COMMUNITY [OWNER] ....................................................................................... 79 1 1.46 rmon event <1-65536> description NAME log trap COMMUNITY [OWNER] ....................................................................................... 79 1 1.47 rmon history <1-65536> IFNAME [OWNER] ................................. 80 1 1.48 rmon history <1-65536> IFNAME buckets <1-100> [OWNER] ...... 80 1 1.49 rmon history <1-65536> IFNAME interval <1-4294967295> [OWNER] ....................................................................................... 81 1 1.50 rmon history <1-65536> IFNAME buckets <1-100> interval <1-4294967295> [OWNER] ........................................................... 81 12. ACL : MAC Filter ................................................................. 82 12.1 mac access-list extended WORD .................................................. 82 12.2 show mac access-group [IFNAME] ................................................ 82
viii 12.3 show mac access-list [ACLNAME] ................................................. 83 12.4 (permit|deny) any any [IFNAME] ................................................... 83 12.5 (permit|deny) MACADDR MACADDR any [IFNAME] .................... 83 12.6 (permit|deny) host MACADDR any [IFNAME] ................................ 84 12.7 (permit|deny) host MACADDR host MACADDR [IFNAME] ........... 85 12.8 (permit|deny) MACADDR MACADDR MACADDR MACADDR [IFNAME] ....................................................................................... 85 12.9 (permit|deny) host MACADDR MACADDR MACADDR [IFNAME] 86 12.10 (permit|deny) MACADDR MACADDR host MACADDR [IFNAME] 87 12.1 1 (permit|deny) any host MACADDR [IFNAME] ................................ 87 12.12 (permit|deny) any MACADDR MACADDR [IFNAME] .................... 88 12.13 mac access-group WORD in ......................................................... 88 13. ACL: IP Filter ....................................................................... 89 13.1 ip access-list extended (<100-199>|<2000-2699>|WORD) ........... 89 13.2 ip access-list standard (<1-99>|<1300-1999>|WORD) .................. 90 13.3 show ip access-group [IFNAME] .................................................... 90 13.4 show ip access list ......................................................................... 90 13.5 show ip access list WORD ............................................................. 91 13.6 show ip access list (<1-99>|<100-199>|<1300-1999>|<2000-2699>| WORD) .......................................................................................... 91 13.7 (permit|deny) any [IFNAME] ........................................................... 91 13.8 (permit|deny) host IP ADDR [IFNAME] ........................................... 92 13.9 (permit|deny) IP ADDR MASK [IFNAME] ........................................ 92 13.10 (permit|deny) (ip|tcp|udp|icmp) any any [IFNAME] ........................ 93 13.1 1 (permit|deny) (tcp|udp) any [eq] [<0-65535>] any [eq] [<0-65535>] [IFNAME] ....................................................................................... 94 13.12 (permit|deny) icmp any any [<1-255>] code [<1-255>] [IFNAME] . 94 13.13 (permit|deny) (ip|tcp|udp|icmp) IP ADDR MASK any [IFNAME] ...... 95 13.14 (permit|deny) (tcp|udp) IP ADDR MASK [eq] [<0-65535>] any [eq] [<0-65535>] [IFNAME] ................................................................... 96 13.15 (permit|deny) icmp IP ADDR MASK any <1-255> code <1-255>
ix [IFNAME] ....................................................................................... 97 13.16 (permit|deny) (ip|tcp|udp|icmp) host IP ADDR any [IFNAME] ......... 97 13.17 (permit|deny) (tcp|udp) host IP ADDR [eq] [<0-65535>] any [eq] [<0-65535>] [IFNAME] ................................................................... 98 13.18 (permit|deny) icmp host IP ADDR any [<1-255>] code [<1-255>] [IFNAME] ....................................................................................... 99 13.19 (permit|deny) (ip|tcp|udp|icmp) host IP ADDR host IP ADDR [IFNAME] ..................................................................................... 100 13.20 (permit|deny) (tcp|udp) host IP ADDR [eq] [<0-65535>] host IP ADDR [eq] [<0-65535>] [IFNAME] .......................................................... 101 13.21 (permit|deny) icmp host IP ADDR host IP ADDR [<1-255>] code [<1-255>] [IFNAME] ..................................................................... 101 13.22 (permit|deny) (ip|tcp|udp|icmp) IP ADDR MASK IP ADDR MASK [IFNAME] ..................................................................................... 102 13.23 (permit|deny) (tcp|udp) IP ADDR MASK [eq] [<0-65535>] IP ADDR MASK [eq] [<0-65535>] [IFNAME] ............................................... 103 13.24 (permit|deny) icmp IP ADDR MASK IP ADDR MASK <1-255> code <1-255> [IFNAME] ....................................................................... 104 13.25 (permit|deny) (ip|tcp|udp|icmp) host IP ADDR IP ADDR MASK [IFNAME] ..................................................................................... 105 13.26 (permit|deny) (tcp|udp) host IP ADDR [eq] [<0-65535>] IP ADDR MASK [eq] [<0-65535>] [IFNAME] ............................................... 106 13.27 (permit|deny) icmp host IP ADDR IP ADDR MASK <1-255> code <1-255> [IFNAME] ....................................................................... 107 13.28 (permit|deny) (ip|tcp|udp|icmp) IP ADDR MASK host IP ADDR [IFNAME] ..................................................................................... 107 13.29 (permit|deny) (tcp|udp) IP ADDR MASK [eq] [<0-65535>] host IP ADDR [eq] [<0-65535>] [IFNAME] ............................................ 108 13.30 (permit|deny) icmp IP ADDR MASK host IP ADDR <1-255> code <1-255> [IFNAME] ....................................................................... 109 13.31 (permit|deny) (ip|tcp|udp|icmp) any host IP ADDR [IFNAME] ........ 1 10 13.32 (permit|deny) (tcp|udp) any [eq] [<0-65535>] host IP ADDR [eq] [<0-65535>] [IFNAME] .................................................................. 1 1 1 13.33 (permit|deny) icmp any host IP ADDR <1-255> code <1-255> [IFNAME] ...................................................................................... 1 12
x 13.34 (permit|deny) (ip|tcp|udp|icmp) any IP ADDR MASK [IFNAME] .....1 12 13.35 (permit|deny) (tcp|udp) any [eq] [<0-65535>] IP ADDR MASK [eq] [<0-65535>] [IFNAME] ..................................................................1 13 13.36 (permit|deny) icmp any IP ADDR MASK <1-255> code <1-255> [IFNAME] ...................................................................................... 1 14 13.37 (permit|deny) (tcp|udp) IP ADDR MASK IP ADDR MASK [eq] [<0-65535>] [IFNAME] ..................................................................1 15 13.38 (permit|deny) (tcp|udp) IP ADDR MASK [eq] [<0-65535>] IP ADDR MASK [IFNAME] ...........................................................................1 15 13.39 (permit|deny) (tcp|udp) IP ADDR A.B.C.D [eq] [<0-65535>] any [IFNAME] ...................................................................................... 1 16 13.40 (permit|deny) (tcp|udp) IP ADDR MASK any [eq] [<0-65535>] [IFNAME] ...................................................................................... 1 17 13.41 (permit|deny) (tcp|udp) IP ADDR MASK [eq] [<0-65535>] host IP ADDR [IFNAME] ........................................................................1 18 13.42 (permit|deny) (tcp|udp) IP ADDR MASK host IP ADDR [eq] [<0-65535>] [IFNAME] ..................................................................1 19 13.43 (permit|deny) (tcp|udp) any [eq] [<0-65535>] IP ADDR MASK [IFNAME] ...................................................................................... 1 19 13.44 (permit|deny) (tcp|udp) any IP ADDR MASK [eq] [<0-65535>] [IFNAME] ..................................................................................... 120 13.45 (permit|deny) (tcp|udp) any any [eq] [<0-65535>] [IFNAME] ....... 121 13.46 (permit|deny) (tcp|udp) any [eq] [<0-65535>] any [IFNAME] ....... 122 13.47 (permit|deny) (tcp|udp) any [eq] [<0-65535>] host IP ADDR [IFNAME] ..................................................................................... 122 13.48 (permit|deny) (tcp|udp) any host IP ADDR [eq] [<0-65535>] [IFNAME] ..................................................................................... 123 13.49 (permit|deny) (tcp|udp) host IP ADDR [eq] [<0-65535>] host IP ADDR [IFNAME] ..................................................................................... 124 13.50 (permit|deny) (tcp|udp) host IP ADDR host IP ADDR [eq] [<0-65535>] [IFNAME] ..................................................................................... 125 13.51 (permit|deny) (tcp|udp) host IP ADDR [eq] [<0-65535>] IP ADDR MASK [IFNAME] .......................................................................... 126 13.52 (permit|deny) (tcp|udp) host IP ADDR IP ADDR MASK [eq] [<0-65535>] [IFNAME] ................................................................. 126
xi 13.53 (permit|deny) (tcp|udp) host IP ADDR [eq] [<0-65535>] any [IFNAME] ..................................................................................... 127 13.54 (permit|deny) (tcp|udp) host IP ADDR any [eq] [<0-65535>] [IFNAME] ..................................................................................... 128 13.55 (permit|deny) icmp IP ADDR MASK IP ADDR MASK <1-255> [IFNAME] ..................................................................................... 129 13.56 (permit|deny) icmp host IP ADDR IP ADDR MASK <1-255> [IFNAME] 129 13.57 (permit|deny) icmp IP ADDR MASK host IP ADDR <1-255> [IFNAME] 130 13.58 (permit|deny) icmp any host IP ADDR <1-255> [IFNAME] ........... 131 13.59 (permit|deny) icmp any IP ADDR MASK <1-255> [IFNAME] ........ 132 13.60 (permit|deny) icmp any any [<1-255>] [IFNAME] ......................... 132 13.61 (permit|deny) icmp IP ADDR MASK any [<1-255>] [IFNAME] ...... 133 13.62 (permit|deny) icmp host IP ADDR any [<1-255>] [IFNAME] ......... 134 13.63 (permit|deny) icmp host IP ADDR host IP ADDR [<1-255>] [IFNAME] 134 13.64 (permit|deny) IP ADDR [IFNAME] ................................................. 135 13.65 remark .LINE ................................................................................ 135 13.66 access-list (<1-99>|<100-199>|<1300-1999>|<2000-2699>) remark .LINE ............................................................................................ 136 13.67 access-list (<1-99>|<1300-1999>) (deny|permit) IP ADDR MASK [IFNAME] ..................................................................................... 136 13.68 access-list (<1-99>|<1300-1999>) (deny|permit) host IP ADDR [IFNAME] ..................................................................................... 137 13.69 access-list (<1-99>|<1300-1999>) (deny|permit) any [IFNAME] .. 138 13.70 access-list (<100-199>|<2000-2699>) (deny|permit) (ip|tcp|udp|icmp) IP ADDR MASK IP ADDR MASK [IFNAME] ....... 138 13.71 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) IP ADDR MASK [eq] [<0-65535>] IP ADDR MASK [eq] [<0-65535>] [IFNAME] ..................................................................................... 139 13.72 access-list (<100-199>|<2000-2699>) (deny|permit) icmp IP ADDR MASK IP ADDR MASK <0-255> code <0-255> [IFNAME] ........... 140 13.73 access-list (<100-199>|<2000-2699>) (deny|permit)
xii (ip|tcp|udp|icmp) IP ADDR MASK any [IFNAME] .......................... 141 13.74 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) IP ADDR MASK [eq] [<0-65535>] any [eq] [<0-65535>] [IFNAME] .... 142 13.75 access-list (<100-199>|<2000-2699>) (deny|permit) icmp IP ADDR MASK any <0-255> code <0-255> [IFNAME] .............................. 143 13.76 access-list (<100-199>|<2000-2699>) (deny|permit) (ip|tcp|udp|icmp) any IP ADDR MASK [IFNAME] .......................... 144 13.77 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) any [eq] [<0-65535>] IP ADDR MASK [eq] [<0-65535>] [IFNAME] ..... 145 13.78 access-list (<100-199>|<2000-2699>) (deny|permit) icmp any IP ADDR MASK <0-255> code <0-255> [IFNAME] ...................... 146 13.79 access-list (<100-199>|<2000-2699>) (deny|permit) (ip|tcp|udp|icmp) any any [IFNAME] ............................................ 147 13.80 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) any [eq] [<0-65535>] any [eq] [<0-65535>] [IFNAME] ........................ 148 13.81 access-list (<100-199>|<2000-2699>) (deny|permit) icmp any any <0-255> code <0-255> [IFNAME] ................................................ 149 13.82 access-list (<100-199>|<2000-2699>) (deny|permit) (ip|tcp|udp|icmp) IP ADDR MASK host IP ADDR [IFNAME] .......... 150 13.83 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) IP ADDR MASK [eq] [<0-65535>] host IP ADDR [eq] [<0-65535>] [IFNAME] ..................................................................................... 151 13.84 access-list (<100-199>|<2000-2699>) (deny|permit) icmp IP ADDR MASK host IP ADDR <0-255> code <0-255> [IFNAME] .............. 152 13.85 access-list (<100-199>|<2000-2699>) (deny|permit) (ip|tcp|udp|icmp) host IP ADDR IP ADDR MASK [IFNAME] .......... 153 13.86 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) host IP ADDR [eq] [<0-65535>] IP ADDR MASK [eq] [<0-65535>] [IFNAME] ..................................................................................... 154 13.87 access-list (<100-199>|<2000-2699>) (deny|permit) icmp host IP ADDR IP ADDR MASK <0-255> code <0-255> [IFNAME] ........ 155 13.88 access-list (<100-199>|<2000-2699>) (deny|permit) (ip|tcp|udp|icmp) host IP ADDR host IP ADDR [IFNAME] .............. 156 13.89 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) host IP ADDR [eq] [<0-65535>] host IP ADDR [eq] [<0-65535>] [IFNAME]
xiii 157 13.90 access-list (<100-199>|<2000-2699>) (deny|permit) icmp host IP ADDR host IP ADDR <0-255> code <0-255> [IFNAME] ........... 158 13.91 access-list (<100-199>|<2000-2699>) (deny|permit) (ip|tcp|udp|icmp) any host IP ADDR [IFNAME] ............................. 159 13.92 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) any [eq] [<0-65535>] host IP ADDR [eq] [<0-65535>] [IFNAME] ........ 160 13.93 access-list (<100-199>|<2000-2699>) (deny|permit) icmp any host IP ADDR <0-255> code <0-255> [IFNAME] ................................. 161 13.94 access-list (<100-199>|<2000-2699>) (deny|permit) (ip|tcp|udp|icmp) host IP ADDR any [IFNAME] ............................. 162 13.95 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) host IP ADDR [eq] [<0-65535>] any [eq] [<0-65535>] [IFNAME] ......... 163 13.96 access-list (<100-199>|<2000-2699>) (deny|permit) icmp host IP ADDR any <0-255> code <0-255> [IFNAME] ........................... 164 13.97 access-list (<1-99>|<1300-1999>) (deny|permit) IP ADDR [IFNAME] 165 13.98 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) IP ADDR MASK IP ADDR MASK eq <0-65535> [IFNAME] ........... 165 13.99 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) IP ADDR MASK [eq] [<0-65535>] IP ADDR MASK [IFNAME] ....... 166 13.100 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) IP ADDR MASK any [eq] [<0-65535>] [IFNAME] .......................... 167 13.101 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) IP ADDR MASK [eq] [<0-65535>] any [IFNAME] .......................... 168 13.102 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) IP ADDR MASK [eq] [<0-65535>] host IP ADDR [IFNAME] .......... 169 13.103 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) IP ADDR MASK host IP ADDR [eq] [<0-65535>] [IFNAME] .......... 170 13.104 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) any IP ADDR MASK [eq] [<0-65535>] [IFNAME] ................................ 171 13.105 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) any any [eq] [<0-65535>] [IFNAME] ................................................... 172 13.106 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) any [eq] [<0-65535>] any [IFNAME] ................................................... 173
xiv 13.107 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) any [eq] [<0-65535>] IP ADDR MASK [IFNAME] ................................ 174 13.108 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) any [eq] [<0-65535>] host IP ADDR [IFNAME] .................................... 175 13.109 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) any host IP ADDR [eq] [<0-65535>] [IFNAME] .................................... 176 13.1 10 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) host IP ADDR IP ADDR MASK [eq] [<0-65535>] [IFNAME] .................. 177 13.1 1 1 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) host IP ADDR [eq] [<0-65535>] IP ADDR MASK [IFNAME] .................. 178 13.1 12 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) host IP ADDR any [eq] [<0-65535>] [IFNAME] ..................................... 179 13.1 13 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) host IP ADDR [eq] [<0-65535>] any [IFNAME] ..................................... 180 13.1 14 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) host IP ADDR [eq] [<0-65535>] host IP ADDR [IFNAME] ...................... 181 13.1 15 access-list (<100-199>|<2000-2699>) (deny|permit) (tcp|udp) host IP ADDR host IP ADDR [eq] [<0-65535>] [IFNAME] ...................... 182 13.1 16 access-list (<100-199>|<2000-2699>) (deny|permit) icmp IP ADDR MASK IP ADDR MASK <0-255> [IFNAME] .................................. 183 13.1 17 access-list (<100-199>|<2000-2699>) (deny|permit) icmp IP ADDR MASK any <0-255> [IFNAME] ..................................................... 184 13.1 18 access-list (<100-199>|<2000-2699>) (deny|permit) icmp any any <0-255> [IFNAME] ....................................................................... 184 13.1 19 access-list (<100-199>|<2000-2699>) (deny|permit) icmp IP ADDR MASK host IP ADDR <0-255> [IFNAME] ...................................... 185 13.120 access-list (<100-199>|<2000-2699>) (deny|permit) icmp host IP ADDR IP ADDR MASK <0-255> [IFNAME] ............................... 186 13.121 access-list (<100-199>|<2000-2699>) (deny|permit) icmp host IP ADDR host IP ADDR <0-255> [IFNAME] ................................... 187 13.122 access-list (<100-199>|<2000-2699>) (deny|permit) icmp any host IP ADDR <0-255> [IFNAME] ......................................................... 188 13.123 access-list (<100-199>|<2000-2699>) (deny|permit) icmp host IP ADDR any <0-255> [IFNAME] .................................................. 189 13.124 access-list (<100-199>|<2000-2699>) (deny|permit) icmp any IP ADDR MASK <0-255> [IFNAME] ............................................. 190
xv 14. Port Security ..................................................................... 190 14.1 show port-security ........................................................................ 191 14.2 show port-security address [IFNAME] ......................................... 191 14.3 show port-security interface [IFNAME] ........................................ 191 14.4 switch port-security ..................................................................... 191 14.5 switch port-security aging-time <0-1440> .................................... 192 14.6 switch port-security aging-type (absolute|inactivity) ..................... 192 14.7 switch port-security mac-address MACADDR ............................. 192 14.8 switch port-security maximun <1-132> ........................................ 193 14.9 switch port-security reup .............................................................. 193 14.10 switch port-security shutdown <10-1440> ................................... 193 14.1 1 switch port-security violation (protect|restrict|shutdown) .............. 194 15. Interface conguration: ................................................... 194 15.1 ingress lter (enable|disable) ....................................................... 194 15.2 show ingress lter IFNAME .......................................................... 195 15.3 ip access-group (<1-199> |<1300-2699>|WORD) in ................... 195 15.4 interface IFNAME ......................................................................... 195 15.5 show interface IFNAME ............................................................... 196 15.6 show interface status ................................................................... 196 15.7 show interface stack <1-8> .......................................................... 196 15.8 interface vlanVLAN-ID ................................................................. 197 15.9 ip address A.B.C.D/M ................................................................... 197 15.10 acceptable frame-type ................................................................. 197 15.1 1 duplex (full|half) ............................................................................ 198 15.12 owcontrol (rx|tx|both) (on|off) ..................................................... 198 15.13 auto-negotiation .......................................................................... 199 15.14 speed (10|100|1000) .................................................................... 199 15.15 shutdown ...................................................................................... 200 15.16 default-priority <0-7> .................................................................... 200
xvi 15.17 mdix ............................................................................................. 201 15.18 description .LINE .......................................................................... 201 15.19 line loopback ................................................................................ 202 16. DHCP Client: ..................................................................... 202 16.1 ip dhcp client ................................................................................ 202 16.2 no ip dhcp client .......................................................................... 202 16.3 ip dhcp client renew ..................................................................... 203 17. DHCP Snooping: ............................................................... 203 17.1 ip dhcp snooping .......................................................................... 203 17.2 ip dhcp snooping vlan VLAN ........................................................ 203 17.3 ip dhcp snooping trust .................................................................. 204 17.4 show ip dhcp snooping ................................................................ 204 17.5 show ip dhcp snooping binding .................................................... 205 18. IP Route: ............................................................................ 205 18.1 ip forwarding ................................................................................ 205 18.2 ip route A.B.C.D A.B.C.D (A.B.C.D|INTERF ACE) ........................ 205 18.3 ip route A.B.C.D A.B.C.D (A.B.C.D|INTERF ACE) <1-255> ......... 206 18.4 ip route A.B.C.D/M (A.B.C.D|INTERF ACE) .................................. 207 18.5 ip route A.B.C.D/M (A.B.C.D|INTERF ACE) <1-255> ................... 207 18.6 show ip route supernets-only ....................................................... 208 19. System Management:....................................................... 208 19.1 show switch .................................................................................. 208 19.2 show switch status ....................................................................... 208 19.3 switch <1-8> ................................................................................. 209 19.4 switch priority <1-8> ..................................................................... 209 19.5 archive download-sw /overwrite tftp: IMAGE ............................... 210 19.6 congure terminal ........................................................................ 210 19.7 copy running-cong startup-cong ............................................... 210 19.8 copy startup-cong tftp: URL ......................................................... 21 1
GigaX2024B/M L2 Managed Switch CLI Manual xvii 19.9 copy tftp: URL startup-cong .........................................................21 1 19.10 disable .......................................................................................... 212 19.1 1 enable .......................................................................................... 212 19.12 end ............................................................................................... 212 19.13 exit ............................................................................................... 213 19.14 hostname WORD ......................................................................... 213 19.15 list ................................................................................................. 213 19.16 tracelog add (dhcp-snooping|dot1x|gvrp|igmp-snooping|lacp|stp) 21 4 19.17 tracelog level (critical | high | low ) ............................................... 214 19.18 ping ip WORD .............................................................................. 215 19.19 ping WORD .................................................................................. 215 19.20 quit ............................................................................................... 215 19.21 reboot ........................................................................................... 216 19.22 reload default-cong le ............................................................... 216 19.23 show running-cong ..................................................................... 216 19.24 show startup-cong ...................................................................... 217 19.25 show version ................................................................................ 217 19.26 show cable-diagnostic interface [IFNAME] .................................. 217 19.27 show private health ...................................................................... 218 19.28 show private led ........................................................................... 218 19.29 show private model ...................................................................... 218 19.30 show uptime ................................................................................. 219 19.31 show clock ................................................................................... 219 19.32 clock set TIME MONTH DA Y YEAR ............................................ 219 19.33 show syslog ................................................................................. 220 19.34 show syslog conguration ............................................................ 220 19.35 syslog (enable|disable) ................................................................ 220 19.36 syslog facility <0-23> ................................................................... 221 19.37 syslog hostname .......................................................................... 221
GigaX2024B/M L2 Managed Switch CLI Manual xviii 19.38 syslog server-ip A.B.C.D .............................................................. 221 19.39 syslog severity <0-7> ................................................................... 222 19.40 syslog timestamp ......................................................................... 222 19.41 telnet WORD ................................................................................ 222 19.42 telnet WORD PORT ..................................................................... 223 19.43 traceroute WORD ........................................................................ 223 19.44 write ............................................................................................. 223 19.45 show arp ...................................................................................... 224 19.46 no arp A.B.C.D ............................................................................ 224 19.47 user add ACCOUNT P ASSWORD ............................................... 224 19.48 user delete USERNAME ............................................................. 225 19.49 show user .................................................................................... 225
GigaX2024B/M L2 Managed Switch CLI Manual 1 CLI Command Modes Command mode Access method Prompt Exit or Access Next Mode. U s e r E X E C T h i s i s th e  r st l ev e l o f a cc e s s. ( Fo r t h e s w i t ch ) Ch a ng e t e r m in a l s e tt i ng s , p e r f or m ba s ic ta s k s, a n d li s t s y st e m i n f o rm a t io n . S w i t ch > E x i t t o en t er th e EX I T c o m m an d . T o e n t er p r i v il e g ed EX E C m o de , e n t e r t h e e na b le c om m an d . P r i v il e g ed E X E C F r o m u s e r E XE C m o d e , e n te r t h e e n a b le c om m an d . S w i t ch # T o e x i t t o u s er E XE C m o de , e n t e r t h e d is a bl e co m ma n d. T o e n t e r g lo b al c on  gu r at i o n m o d e , e n te r t h e c o n g ur e t e r m in a l c o mm a nd . G l o b al c o n  gu r a ti o n F r o m pr iv il eg ed E XE C m o d e , e n te r t h e c o n  gu r e c o mm a nd . S w i t ch ( c o n g ) # T o e x i t t o p r iv i l eg e d E XE C m o d e , e n te r t h e e x it or e n d co m m an d , o r p r es s C t r l -Z . T o e n t e r i nt e rf a c e c o n  gu r a ti o n m od e , e n te r t h e in t e rf a ce IF N A ME c o n  gu r a ti o n command. Interface conguration From global conguration mode, specify an interface by entering the interface command followed by an interface identication. Switch (cong-if)# T o exit to privileged EXEC mode, enter the end command, or press Ctrl-Z. T o exit to global conguration mode, enter the exit command. Cong-vlan In global conguration mode, enter the vlan vlan- id command. Switch (cong- vlan)# T o exit to global conguration mode, enter the exit command. T o return to privileged EXEC mode, enter the end command, or press Ctrl-Z. mac access- list extended [NAME] In global conguration mode, enter the ACL NAME command. Switch (cong-ext- mac)# T o exit to global conguration mode, enter the exit command. T o return to privileged EXEC mode, enter the end command, or press Ctrl-Z.
GigaX2024B/M L2 Managed Switch CLI Manual 2 1. IGMP 1 . 1 i p i g m p s n o o p i ng Syntax: ip igmp snooping P a r a me t e rs : i g m p I nt e r ne t G r ou p Ma n ag e me n t P r ot o co l s n o o pi n g I GM P s n o o pi n g o n a l l t he e xi s ti n g V L AN s C o m m an d Mo d e: C o n g ur e t e r mi n al mo d e N o / c le a r : n o i p i g mp sn o op i n g S h o w : s h o w i p ig m p s no o p in g D e f a ul t : T h e de f a ul t s e tt i n g o f I GM P s n o o pi n g i s g l ob a l ly di s ab l e D e s c ri p t io n : T h i s c o m ma n d s et s th e I G MP s no op in g f u nc t i on en a bl e d g l o b al l y . E x a m pl e : A S U S (c o n g ) # i p i g mp sn o op i n g 1 . 2 i p i g m p s no o p i n g l as t - m em b e r - q u e ry - i n t e r v al T I M E V A LU E Syntax: ip igmp snooping last-member-query-interval TIMEV ALUE P a r a me t e rs : i g m p In t er n et G ro u p M an a g em e nt Pr o t oc o l s n o o pi n g I GM P s n o o pi n g o n a l l t h e e xi s ti n g V L AN s l a s t -m e m be r -q u er y - in t er v al t h e in t e rv a l f or w hi c h t he s wi t ch w a i t s b e fo r e u pd a t in g t h e t a bl e e n tr y T I M E V AL UE t h e i n te r va l fo r t h e I G MP q u e r i es se n t b y t h e s w i t ch ( de f au l t 1 se c ) , va l i d r an g e i s 1 0 0~ 1 00 0 mi l li s ec o n ds . C o m m an d Mo d e: C o n g ur e t e r mi n al mo d e N o / c le a r : n o i p i g mp sn o op i n g l as t -m e m be r -q u er y - in t er v al S h o w : s h o w i p ig m p s no o p in g D e f a ul t : T h e de f a ul t i s 1 s e co n d D e s c ri p t io n : T h i s c o m ma n d s et s th e i n te r v al ti m e f o r t he IG M P q u e ri e s s e nt b y s wi t c h. E x a m pl e : A S U S( c on g ) # ip ig mp sn oo p in g l as t- m em be r -q ue r y- in t er va l 1 00
GigaX2024B/M L2 Managed Switch CLI Manual 3 1 . 3 i p i g m p s n o o p i ng v l a n < 1 -3 0 0 0 > S y n t ax : i p i gm p sn o op i ng v la n < 1 -3 0 0 0> P a r a me t e rs : i g m p I n t e rn e t G r ou p M a n ag e me n t P r ot o co l s n o o pi n g I G M P s n o o pi n g o n a l l t he e xi s ti n g V L AN s v l a n I G M P S n o o pi n g e n ab l e f or a s p ec i e d vl a n < 1 - 3 00 0 > Vl an n um b er C o m m an d Mo d e: C o n g ur e t e r mi n al mo d e N o / c le a r : n o i p i g mp sn o op i n g v la n < 1 - 30 0 0> S h o w : s h o w i p ig m p s no o p in g s h o w i p ig m p s no o p in g v l an < 1- 3 00 0 > D e f a ul t : T h e de f a ul t s e tt i n g o f I GM P s n o o pi n g o n e a ch v la n i s e n a bl e a f t e r I G MP s n o o p in g f u nc t i on is gl o b al l y e na b l e. D e s c ri p t io n : T h i s c o m ma n d s et s th e I G MP s no op in g f u nc t i on en a bl e d o n i n d i ca t e d v la n . E x a m pl e : A S U S (c o n g ) # i p i g mp sn o op i n g v la n 1 1. 4 ip ig mp sn oo pi ng v la n < 1- 30 00 > i mme di at e- l e a v e S y n t ax : i p i gm p sn o op i ng v la n < 1 -3 0 0 0> im m ed i a te - le a ve P a r a me t e rs : i g m p In t e rn e t G ro u p M a na g em e n t P ro t oc o l s n o o pi n g I G M P s n o o pi n g o n a l l t he e xi s ti n g V L AN s v l a n I G M P S n o o pi n g e n ab l e f o r a s p ec i  ed vl a n < 1 - 3 00 0 > Vl an n um b er i m m e di a t e- l ea v e E n a b le I GM P I m m e di a te - Le a v e p ro c es s i ng C o m m an d Mo d e: C o n g ur e t e r mi n al mo d e N o / c le a r : n o i p i g mp sn o op i n g v la n < 1 - 30 0 0> im m e di a te - le a v e S h o w : s h o w i p ig m p s no o p in g v l an < 1- 3 00 0 > D e f a ul t : T h e de f a ul t s e tt i n g o f i gm p im m ed i at e - le a ve on e ac h v l an i s
GigaX2024B/M L2 Managed Switch CLI Manual 4 d i s a bl e d a f te r I G M P s n oo p i ng fu n ct i o n i s g lo b a ll y e n ab l e . D e s c ri p t io n : T h i s c o m ma n d s et s th e I G MP s no op in g i m me d i at e -l e av e f u n c ti o n e n ab l ed o n i nd i ca t e d v la n . E x a m pl e : A S U S (c o n g ) # i p i g mp sn o op i n g v la n 1 i mm e di a te - l ea v e 1 . 5 s h o w i p i g m p s no o p i n g S y n t ax : s h o w i p ig m p s no o p in g P a r a me t e rs : s n o o pi n g S no o pi n g i n fo r ma t i on on al l Vl a ns C o m m an d Mo d e: P r iv i le g ed E XE C m o de D e f a ul t : N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n : U s e th e sh o w i p i g mp pr i vi l e ge d E X EC c om m an d t o vi e w a ll c o n  gu r e d I nt e rn e t G r ou p M a n ag e me n t P r ot o co l ( I G MP ) p r o l e s o r a s p e ci  ed IG M P p r o l e . E x a m pl e : A S U S # s h ow ip ig m p s n oo p in g 1 . 6 s h o w i p i g m p s no o p i n g v l an < 1 - 3 0 0 0 > S y n t ax : s h o w i p ig m p s no o p in g v l an < 1- 3 00 0 > P a r a me t e rs : v l a n S n o o pi n g i n fo r ma t i on on a s p ec i e d v l a n < 1 - 3 00 0 > VL AN n um b er C o m m an d Mo d e: P r iv i le g ed E XE C m o de D e f a ul t : N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n : U s e th e sh o w i p i g mp sn o op i n g v la n p r i vi l eg e d E X EC co m ma n d t o d is p l ay th e I n t er n et Gr o u p M an a ge m e nt Pr o to c o l ( IG M P) s n o o pi n g v l an fo r th e s w it c h o r m u lt i c as t i n fo r m at i on fo r th e s e l e ct e d p a ra m et e r . U s e w it h t h e v l an ke y w or d t o d i s pl a y t he V L A N o r in f or m at i o n a bo u t t h e s el e ct e d p a ra m et e r f o r t he V LA N . E x a m pl e : A S U S # s h ow ip ig m p s n oo p in g vl a n 1
GigaX2024B/M L2 Managed Switch CLI Manual 5 LACP: 2 . 1 l a c p a g g re g a t io n - li n k g ro up < 1 - 3 2> ( a d d | se t ) I F L I S T G X 2 0 24 B GR O UP I D r a ng e i s 1 - 6 S y n t ax l a c p a g g re g at i on - l in k t r un k <1 - 32 > ( a d d| s et ) I F L IS T P a r a me t e rs a g g r eg a t io n -l i nk a g g r eg a t io n -l i nk < 1 - 3 2> G R O U PI D a d d a p p e nd po r t s t o l ac p en a bl e d p o rt li s t s e t se t la c p e n ab l ed p or t l i st f or th i s g r ou p P O R TL IS T va l id f or m at is p or t _i d ,[ , p or t _i d .. . ] ,[ - po r t_ i d ,. . .] , .. . C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r l a c p a g g re g at i on - l in k g r ou p de l et e I F N AM E n o l ac p ag g re g at i o n- l in k g r o up <1 - 32 > S h o w s h o w l a c p [ GR O UP I D ] D e f a ul t N o d ef a u lt la c p a g gr e ga t io n - li n k t ru n k g r ou p e n a bl e D e s c ri p t io n T h i s co m m an d se t s t h e L i n k A g g r e g at i o n C o nt r o l P r ot o c ol ( LA C P ) o p e r at i o n a dd / se t fo r t h e t r un k g r ou p po r ts on t he sw i tc h st a ck or o n a s t a nd a lo n e s w it c h. E x a m pl e A S U S (c o n g ) # l ac p ag g re g at i o n- l in k g r o up <1 - 32 > (a d d| s et ) f a 1 / 0/ 1 - 4 2 . 2 l a c p a g g r e g a t i on - l i n k g r ou p d e l e t e I FN A M E S y n t ax l a c p a g g re g at i on - l in k g r ou p de l et e I F N AM E P a r a me t e rs a g g r eg a t io n -l i nk a g g r eg a t io n -l i nk g r o u p g r o u p d e l e te r e m o v e p o rt s f r o m l ac p e n a bl e d p or t li s t I F N A ME i n t e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e
GigaX2024B/M L2 Managed Switch CLI Manual 6 N o / c le a r l a c p a g g re g at i on - l in k g r ou p de l et e I F N AM E S h o w s h o w a g g re g at i on - l in k g r ou p [G R OU P ID ] D e f a ul t N o d ef a u lt la c p a g gr e ga t io n - li n k t ru n k g r ou p e n a bl e D e s c ri p t io n T h i s co m m an d se t s t h e L i n k A g g r e g at i o n C o nt r o l P r ot o c ol ( LA C P ) o p e r at i o n a dd / se t or di s ab l e f o r t he t ru n k g ro u p p o rt s o n th e s w i t ch s ta c k o r o n a st a nd a l on e s w it c h . E x a m pl e A S U S (c o n g ) # l ac p ag g re g at i o n- l in k g r o up de l et e fa 1 /0 / 1 2 . 3 l a c p s y s t e m - p r io r i t y < 1 - 65 5 3 5 > S y n t ax l a c p s y s te m -p r io r i ty <1 - 65 5 3 5> P a r a me t e rs s y s t em - p ri o ri t y P r i o ri t y o f t h e s y st e m < 1 - 6 55 3 5 > V al id v a l ue s a r e f r om 1 t o 6 5 53 5 C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o l ac p sy s te m -p r i or i ty S h o w s h o w l a c p s ys t em - p ri o ri t y / sh o w r un n i ng - co n g D e f a ul t T h e de f a ul t i s 3 2 7 68 . D e s c ri p t io n T h i s c o m ma n d s et s th e s y st e m p r io r it y fo r t h e L i nk A g g r eg a ti o n C o n t ro l Pr o to c ol ( LA C P) on t he sw i tc h st a ck or o n a s t an d a lo n e s w i t ch . E x a m pl e A S U S (c o n g ) # l ac p sy s te m -p r i or i ty 20 0 0 2 . 4 s h o w l a c p [ G R O UP I D ] G X 2 0 24 B GR O UP I D r a ng e i s 1 - 6 S y n t ax s h o w l a c p [ GR O UP I D ] P a r a me t e rs [ G R O UP I D ] va l id g ro u p- i d r a ng e i s 1 t o 3 2 C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w l ac p us e r E XE C co m ma n d t o d i sp l ay L in k A g g r eg a t io n C o nt r o l P ro t oc o l ( L AC P ) c h an n el - gr o u p i nf o rm a t io n . E x a m pl e A S U S #s h o w l ac p 1
GigaX2024B/M L2 Managed Switch CLI Manual 7 3. Static Link Aggregation 3 . 1 a g g r e g a t i o n - l i nk g r o u p < 1- 3 2 > P O R T L I ST G X 2 0 24 B GR O UP I D r a ng e i s 1 - 6 S y n t ax a g g r eg a t io n -l i nk t ru n k < 1- 3 2 > P OR TL IS T P a r a me t e rs a g g r eg a t io n -l i nk s t a t ic t ru n k a gg r e ga t io n l i n k i nf o rm a t io n g r o u p li nk tr u nk gr o u p G R O U PI D T r u nk gr o up I D 1 -3 2 C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a gg r e ga t io n -l i n k g ro u p < 1 -3 2 > s h o w s h o w a g g re g at i on - l in k g r ou p <1 - 32 > D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e ag g re g at i o n- l in k t r u nk gr o up c on  gu r at i o n c om m an d o n t he s wi t ch st a c k o r s ta n d al o ne sw i t ch to co n  gu r e t ru n k a g g r eg a t io n g r ou p . E x a m pl e A S U S (c o n g ) #a g gr e g at i on - li n k g r ou p 1 f a1 / 0/ 1 -4 3 . 2 agg re ga tio n- lin k gro up <1-3 2> loa d- ba lan ce (s rc- m a c | d st -ma c |s rc -ds t-m a c |s r c- ip | d s t- ip | s rc - d s t - i p ) G X 2 0 24 B GR O UP I D r a ng e i s 1 - 6 S y n t ax a g g r eg a t io n -l i nk g ro u p < 1- 3 2 > l oa d -b a l an c e ( sr c - ma c | d st - m ac | s r c -d s t -m a c | sr c - ip |d s t- i p | s rc - ds t - ip ) P a r a me t e rs G R O U PI D T r u nk gr o up I D 1 -3 2 s r c - ma c -> So ur c e M ac ad d r es s . d s t - ma c -> De st in a t io n M a c a d dr e ss . s r c - ds t - ma c - > So u rc e a n d D e st i na t io n Ma c a d dr e s s. s r c - ip - > S o u r ce I P a d dr e s s.
GigaX2024B/M L2 Managed Switch CLI Manual 8 d s t - ip - > D e s t in a ti o n I P a d d r es s . s r c - ds t - ip -> S o u r ce a nd De s ti n a ti o n I P a d d re s s. C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r s h o w s h o w a g g re g at i on - l in k g r ou p <1 - 32 > D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e ag g re g at i o n- l in k t r u nk gr o up c on  gu r at i o n c om m an d o n t he s wi t ch st a c k o r s ta n d al o ne sw i t ch to co n  gu r e t ru n k l o a d b a l an c in g b y us i ng so u r ce - ba s ed o r d es t in a t io n -b a se d f o r w ar d i ng me t ho d s . E x a m pl e A S U S (c o n g ) # a gg r e ga t io n -l i n k g ro u p 1 lo a d- b al a n ce sr c -m a c 3 . 3 s h o w a g g r e g a t i on - l i n k g r ou p [ G R O U P I D ] G X 2 0 24 B GR O UP I D r a ng e i s 1 - 6 S y n t ax s h o w a g g re g at i on - l in k g r ou p [G R OU P ID ] P a r a me t e rs a g g r eg a t io n -l i nk s t a t ic t ru n k a gg r e ga t io n l i n k i nf o rm a t io n g r o u p T r un k mo d e [ G R O UP I D ] 1 - 3 2 C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w a g gr e ga t i on - li n k t r un k s t at u s . E x a m pl e A S U S # s h ow ag g re g a ti o n- l in k gr o up 1 4. GVRP 4 . 1 c l e a r g v r p s t a ti s t i c s [ I FN A M E ] S y n t ax c l e a r g v rp st a ti s t ic s [ I FN A M E] P a r a me t e rs [ I F N AM E ] I nt e rf a c e’ s n a me , ex : f a st e t he r ne t 1/ 0 / 1 o r g i g a bi t e th e rn e t1 / 0 /2 6 C o m m an d Mo d e C on g ur e te r mi n al m od e
GigaX2024B/M L2 Managed Switch CLI Manual 9 N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e cl e ar gv r p s t at i st i c s c on  gu r a ti o n c om m a nd on th e s w i t ch s ta c k o r s t an d al o ne s wi t ch to c le a r a ll t he GV R P s t a ti s ti c s i n f o rm a t io n o n o n e o r a l l i n te r fa c es . E x a m pl e A S U S (c o n g ) # c le a r g v rp st a t is t ic s f a 1 /0 / 1 4 . 2 g v r p ( e n a b l e | d is a b l e ) S y n t ax g v r p ( e n ab l e| d is a b le ) P a r a me t e rs d i s a bl e - > D i s a bl e GV R P f e a tu r e g lo b a ll y o n t h e sw i tc h e n a b le - > E n a b le G VR P f e a t ur e g l ob a l ly on th e sw i tc h C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r g v r p d i s ab l e S h o w s h o w g v r p D e f a ul t T h e de f a ul t i s d i s ab l ed on t he sw i tc h . D e s c ri p t io n T h i s c o m ma n d s et s th e G V RP f ea tu re gl o ba l l y e na b le o r d is a bl e o n t he s wi t ch . O r en a bl e w i t h t he in t e rf a ce E x a m pl e A S U S (c o n g ) #g v rp e na b le 4 . 3 g v r p ( e n a b l e | d is a b l e ) S y n t ax g v r p ( e n ab l e| d is a b le ) P a r a me t e rs d i s a bl e -> D i s ab l e G VR P f e a t ur e gl o ba l ly o n t he sw i t ch e n a b le - > E n a b le G VR P f e a t ur e g l ob a l ly on th e sw i tc h C o m m an d Mo d e I nt er fa c e C o n g ur e mo d e N o / c le a r g v r p d i s ab l e S h o w s h o w g v r p D e f a ul t T h e de f a ul t i s d i s ab l ed on t he sw i tc h . D e s c ri p t io n T h i s c o m ma n d s et s th e G V RP f ea tu re en a bl e or di s ab l e w i th th e i n t e rf a c e E x a m pl e A S U S (c o n g - if ) #g v r p e na b le
GigaX2024B/M L2 Managed Switch CLI Manual 10 4 . 4  g v r p  r e g i s t r a t io n  ( n o r m a l|  x e d | f o r b i dd e n )  S y n t ax g v r p r e g is t ra t io n (n o rm a l|  x ed | fo r bi d d en ) P a r a me t e rs r e g i st r a ti o n G V R P r e g i st r at i o n m od e n o r m al - > n o r m al re g i st r at i on m od e  x e d - >  x e d r e gi s t ra t io n m o d e f o r b id d e n - > f o r b id d e n r eg i st r a ti o n m od e C o m m an d Mo d e I nt er fa c e C o n g ur e mo d e N o / c le a r c l e a r g v rp st a ti s t ic s I F NA M E S h o w s h o w g v r p i nt e rf a c e I FN A ME D e f a ul t T h e de f a ul t i s N o r ma l o n e a c h i nt e rf a c e a ft e r t h e i nd i ca t e d i n t e rf a c e g vr p m o d e i s e na b l ed . D e s c ri p t io n T h i s c o m ma n d s et s th e g v rp r eg i st r at i o n t yp e o f th e i n di c a te d i n t e rf a c e. E x a m pl e A S U S (c o n g - if ) # g v rp re g is t r at i on x e d 4 . 5 s h o w g v r p S y n t ax s h o w g v r p c on  gu r a ti o n I FN A M E P a r a me t e rs g v r p G e ne r al A t t r i bu t e R eg i s tr a ti o n P r ot o co l C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w g v rp co n  gu r at i on s ta t us . E x a m pl e A S U S #s h o w g vr p 4 . 6 s h o w g v r p s t a t is t i c s [ I F NA M E ] S y n t ax s h o w g v r p s ta t is t i cs [I F NA M E ] P a r a me t e rs g v r p G e n e r al A t t r ib u t e R eg i st r a ti o n P ro t o co l s t a t is t i cs t he G VR P s t a t is t ic s [ I F N AM E ] I nt er f ac e ’s n am e , e x: f as t et h er n e t1 / 0/ 1 o r g i g a bi t e th e rn e t1 / 0 /2 6 C o m m an d Mo d e P ri vi le g e d E XE C m o d e
GigaX2024B/M L2 Managed Switch CLI Manual 1 1 D e f a ul t D e s c ri p t io n T o s h o w g v rp st a t is t ic s I F N AM E s t at u s . E x a m pl e A S U S # s h ow gv r p s t at i st i cs f a1 / 0/ 1 4 . 7  s h o w  g v r p  i n t e rf a c e  I F N A ME  S y n t ax s h o w g v r p i nt e rf a c e I FN A ME P a r a me t e rs g v r p G e n er a l At tr ib ut e R e gi s tr a ti o n P r ot o co l [ I F N AM E ] I nt er f ac e ’s n am e , e x: f as t et h er n e t1 / 0/ 1 o r g i g a bi t e th e rn e t1 / 0 /2 6 C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w g v rp po r t s t at u s. E x a m pl e A S U S #s h o w g vr p i n t er f ac e f a 1 /0 / 1 2 4 . 8 g a r p j o i n - t i m e r < 1 - 1 0 0 0 0 00 0 0 > S y n t ax g a r p j o i n- t im e r < 1 -1 0 00 0 00 0 0 > P a r a me t e rs j o i n -t i m er J oi n ti m er < 1 - 1 00 0 0 00 0 0> th e ti m er v al u es C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o g ar p jo i n- t im e r S h o w s h o w g a r p t im e r I F NA M E D e f a ul t T h e de f a ul t i s 2 0 (c e nt i -s e c on d s) D e s c ri p t io n T h i s c o m ma n d s et s th e g a rp j oi n -t i me r va l ue in t he in d ic a t ed i n t e rf a c e p or t . E x a m pl e A S U S (c o n g - if ) #g a r p j oi n -t i m er 20 4 . 9 g a r p l e a v e a l l - ti m e r < 1 - 1 00 0 0 0 0 0 0 > S y n t ax g a r p l e a ve a ll - ti m e r < 1- 1 00 0 0 00 0 0> P a r a me t e rs l e a v e- t i me r L e a ve t im e r < 1 - 1 00 0 0 00 0 0> t h e t i m er va l ue s
GigaX2024B/M L2 Managed Switch CLI Manual 12 C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o g ar p le a ve a ll - t im e r S h o w s h o w g a r p t im e r I F NA M E D e f a ul t T h e de f a ul t i s 1 0 0 0 ( ce n ti - s ec o nd s ) D e s c ri p t io n T h i s c o m ma n d s et s th e g a rp l ea v ea l l- t i me r v a lu e in th e i n d ic a te d i n t e rf a c e p or t . E x a m pl e A S U S (c o n g - if ) #g a r p l ea v ea l l -t i me 20 0 0 4 . 1 0 g a r p le a v e - t i m e r < 1 - 1 0 0 0 0 0 0 00 > S y n t ax g a r p l e a ve - ti m er < 1- 1 00 0 00 0 0 0> P a r a me t e rs l e a v ea l l -t i me r L ea ve a ll ti m er < 1 - 1 00 0 0 00 0 0> th e ti m er v al u es C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o g ar p le a ve - ti m e r S h o w s h o w g a r p t im e r I F NA M E D e f a ul t T h e de f a ul t i s 6 0 (c e nt i -s e c on d s) D e s c ri p t io n T h i s c o m ma n d s et s th e g a rp l ea v e- t im e r v a lu e i n th e i n di c a te d i n t e rf a c e p or t . E x a m pl e A S U S (c o n g - if ) #g a r p l ea v e- t i me r 6 0 4 . 1 1 s h o w g a r p t i m e r I F N A M E S y n t ax s h o w g a r p t im e r I F NA M E P a r a me t e rs t i m e r th e se t t in g t i me r va l ue s ( j o in , l e av e , a n d l e a v ea l l t i me r ) [ I F N AM E ] I nt er f ac e ’s n am e , e x: f as t et h er n e t1 / 0/ 1 o r g i g a bi t e th e rn e t1 / 0 /2 6 C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w g a rp ti m e r I FN A ME s ta t us . E x a m pl e A S U S # s h ow ga r p t i me r f a 1/ 0 / 1
GigaX2024B/M L2 Managed Switch CLI Manual 13 5. VLAN: 5 . 1 s h o w v l a n n a m e V L A N A M E S y n t ax s h o w v l a n n am e V L A NA M E P a r a me t e rs V L A N AM E v l an na m e C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w v la n us e r E XE C co m ma n d t o d i sp l ay t he p a r a me t e rs fo r a l l c o n g ur e d V L AN s o r on e V L AN ( if th e V L A N I D o r n a me is sp e c i e d) on t he sw i tc h . E x a m pl e A S U S #s h o w v la n n a m e V LA N 1 5 . 2 v l a n < 2 - 3 0 0 0 > S y n t ax v l a n < 2 - 30 0 0> P a r a me t e rs v i d v l a n i d N o / c le a r n o v la n <2 - 30 0 0> C o m m an d Mo d e G lo ba l c o n g ur a ti o n m o de D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e vl a n v id c om m an d t o cr e at e v l a n e nt r y o n t h e s wi t c h. E x a m pl e A S U S (c o n g ) #v l an 2 5 . 3 s h o w v l a n [ V L A NI D ] S y n t ax s h o w v l a n [ VL A NI D ] P a r a me t e rs [ V L A NI D ] v la n i d C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w v la n us e r E XE C co m ma n d t o d i sp l ay t he p a r a me t e rs fo r a l l c o n g ur e d V L AN s o r on e V L AN ( if th e V L A N I D o r n a me is sp e c i e d) on t he sw i tc h . E x a m pl e A S U S #s h o w v la n 2
GigaX2024B/M L2 Managed Switch CLI Manual 14 5 . 4 n a m e V L A N A M E S y n t ax n a m e V L A NA M E P a r a me t e rs V L A N AM E - v la n n a m e s tr i ng N o / c le a r n o n am e C o m m an d Mo d e C on g -v l a n m od e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e na m e s tr i n g c om m an d to cr e at e vl a n e nt r y w i th st r i ng on t h e sw i t ch . E x a m pl e A S U S (c o n g - vl a n) # n am e A B C 5 . 5 s w i t c h p o r t a c c es s v l a n < 1- 3 0 0 0 > S y n t ax s w i t ch p o rt ac c es s vl a n < 1- 3 0 00 > P a r a me t e rs a c c e ss t he i nt e r fa c e i n a c ce s s m od e v l a n V i r t u al L AN < 1 - 3 00 0 > va l id vl a n -i d r a ng e is 1 t o 3 0 00 C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o s wi t c hp o rt ac c e ss vl a n S h o w s h o w v l a n [ VL A NI D ] D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n S e t ac c e ss mo d e c h ar a ct e ri s t ic s o f a l l i n te r fa c e s a nd Se t V i r t ua l L A N E x a m pl e A S U S (c o n g - if ) #s w i tc h po r t a c ce s s v la n 2 5 . 6 s w i t c h p o r t m o d e ( a c c e s s | tr u n k ) S y n t ax s w i t ch p o rt mo d e ( a cc e ss | tr u n k) P a r a me t e rs a c c e ss t he i nt e r fa c e i n a c ce s s m od e t r u n k t h e i nt e rf a c e i n t ru n k m o de C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o s wi t c hp o rt ac c e ss vl a n
GigaX2024B/M L2 Managed Switch CLI Manual 15 S h o w s h o w i n t er f ac e [ I F NA M E] D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n S e t ac c e ss mo d e c h ar a ct e ri s t ic s o f a l l i n te r fa c e s a nd Se t V i r t ua l L A N E x a m pl e A S U S (c o n g - if ) #s w i tc h po r t m o de ac c es s 5 . 7 s w i t c h p o r t t r u nk n a t i v e vl a n < 1 - 3 0 0 0 > S y n t ax s w i t ch p o rt tr u nk n at i ve vl a n < 1 -3 0 00 > P a r a me t e rs t r u n k t he i nt e rf a ce i n t ru n k m o de n a t i ve un ta g vl a n v l a n V i r t u a l L A N < 1 - 3 00 0 > va li d vl a n- i d r a ng e i s 1 t o 3 00 0 C o m m an d Mo d e I nt er fa c e m o de N o / c le a r S h o w s h o w v l a n [ VL A NI D ] D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n S e t na t i ve vl a n o f t h e p or t E x a m pl e A S U S (c o n g - if ) #s w i tc h po r t t r un k n a ti v e v l an 2 5 . 8 swi tch po rt tru nk all ow ed vla n (ad d|r emo ve ) V L A N L I S T S y n t ax s w i t ch p o rt tr u nk a ll o we d v l a n ( ad d |r e m ov e ) V LA N L IS T P a r a me t e rs t r u n k t r un k c h ar a c te r is t ic s a l l o we d t h e al l o we d V L AN s th a t c an r ec e iv e a n d s e nd tr a f c o n t hi s in t er f ac e in ta g ge d fo r ma t w h e n i n t ru n k in g m o de v l a n t h e a ll o we d VL A Ns a d d t o ad d t he li s t o f a l lo w ed V LA N s r e m o ve to r em ov e t h e l is t of al l ow e d V L AN s V L A N LI S T v a li d fo r ma t i s vl a n_ a to m , [ , vl a n_ a t om . .. ] , [ - v l an _ a to m ,. . .] , . ..
GigaX2024B/M L2 Managed Switch CLI Manual 16 C o m m an d Mo d e I nt er fa c e m o de N o / c le a r s w i t ch p o rt tr u nk a ll o we d v l a n r em o ve V LA N LI S T S h o w s h o w v l a n [ VL A NI D ] D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sw i tc h po r t t r un k a l l ow e d v la n co n g u ra t i on co m ma n d o n t he s wi t ch st a c k o r s ta n d al o ne sw i t ch to ad d or re m ov e th e a l l o we d VL A Ns th a t c a n r ec e i ve an d s e n d t ra f c o n t hi s i n t er f ac e i n t ag g e d f or m at w he n i n t r u nk i ng mo d e E x a m pl e A S U S (c o n g - if ) # s w it c hp o rt t ru n k a ll o w ed vl a n a d d 2 -2 0 6. 802.1x: 6 . 1  d o t 1 x  g u e s t - v l an  < 1 - 3 0 0 0 > S y n t ax d o t 1 x g u es t -v l an < 1- 3 00 0 > P a r a me t e rs < 1 - 3 00 0 > v al i d v l an - id ra n g e i s f ro m 1 t o 3 00 0 C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o d ot 1 x g u es t -v l a n S h o w s h o w d o t 1x al l / s ho w d o t1 x in t er f ac e IF N AM E D e f a ul t N o d ef a u lt gu e st v la n D e s c ri p t io n U s e th e do t 1x gu e s t- v la n i n t er f ac e c o n g u ra t io n co m ma n d o n t he s wi t ch st a c k o r o n a st a nd a lo n e s w it c h t o s p ec i fy a n a c t i ve V LA N a s a n 80 2 .1 X g u e st VL A N. U se th e n o fo r m o f t h is c o m m an d to re t ur n to th e d e f au l t s et t i ng . E x a m pl e A S U S (c o n g - if ) #d o t 1x gu e st - v la n 2 6 . 2  d o t 1 x  m a x - r e q  < 1 -1 0 > S y n t ax d o t 1 x m a x- r eq <1 - 1 0> P a r a me t e rs < 1 - 1 0> m a x - re q ti m es ; v a li d v a lu e s a r e f ro m 1 t o 1 0 C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o d ot 1 x m a x- r eq S h o w s h o w d o t 1x al l
GigaX2024B/M L2 Managed Switch CLI Manual 17 D e f a ul t T h e de f a ul t i s 2 D e s c ri p t io n U s e th e do t 1x ma x - re q i n te r f ac e c o n g u ra t io n c o m ma n d o n t he s wi t ch st a c k o r o n a st a nd a lo n e s w it c h t o s e t t he m a x i mu m nu m be r o f ti m es th a t t h e s wi t c h s en d s a n E x te n si b l e A u t h en t i ca t io n P r o to c ol (E A P )- r eq u es t / id e nt i ty f ra m e ( as s u mi n g t h a t n o re s po n se i s r ec e iv e d ) t o t he c li e nt be f o re re s ta r t in g t h e a u t h en t i ca t io n p r o ce s s. Us e th e n o f o r m o f t hi s co m ma n d t o r e t u rn t o t he de f a ul t s e tt i n g. E x a m pl e A S U S (c o n g - if ) #d o t 1x ma x -r e q 2 6 . 3  d o t 1 x  p o r t - c o n t r o l  ( a u t o | f o r c e - a u t h o r i z e d |  f o r c e - u n a u t h o r iz e d ) S y n t ax d o t 1 x p o rt - co n tr o l ( a ut o |f o r ce - au t ho r i ze d | f or c e -u n au t ho r i ze d ) P a r a me t e rs a u t o - > En ab le s 8 0 2. 1 x p or t - ba s ed au t h en t ic a ti o n a n d ca u s es th e p o r t t o b eg i n i n t h e u n au t ho r iz e d s t at e , a l lo w in g o n l y E A P OL f r a me s t o b e se n t a nd r ec e iv e d t h ro u gh th e po r t f o r c e- a u th o ri z ed - > Di sa bl e s 8 02 . 1 x p or t -b a s ed au t he n t ic a ti o n a n d ca u s es th e p o r t t o t ra n s it i on to t he au t ho r i ze d s t at e w i t h ou t an y a u th e n ti c at i on e xc h an g e r e qu i re d f o r c e- u n au t ho r iz e d - > C a us e s t h e p or t to re m ai n in th e u n a u th o r iz e d s ta t e , i gn o ri n g a l l a tt e m pt s b y t h e c l ie n t t o a u t h en t i ca t e C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o d ot 1 x p o rt - co n t ro l S h o w s h o w d o t 1x al l / s ho w d o t1 x in t er f ac e IF N AM E D e f a ul t T h e de f a ul t i s F o r ce A ut h or i z ed D e s c ri p t io n U s e th e do t 1x po r t -c o nt r ol i nt e rf a ce c on  gu r at i o n c om m an d on t h e sw i t ch st a ck o r o n a s t a nd a lo n e s w it c h t o e n ab l e m an u a l c o n t ro l of th e a u t ho r iz a ti o n s t at e o f th e p o rt . Us e t h e n o f o rm of t h i s c o m ma n d t o r e tu r n t o t h e d ef a ul t se t ti n g. E x a m pl e A S U S (c o n g - if ) # d o t1 x p o rt - c on t ro l a u t o
GigaX2024B/M L2 Managed Switch CLI Manual 18 6 . 4  do t 1 x  ra d i u s  s e r v e r  A .B . C . D  RA D I U S _ K E Y  [ P O R T I D ] S y n t ax d o t 1 x r a di u s s er v e r A . B . C .D RA D I US _ KE Y [ P O R T I D ] P a r a me t e rs A . B . C. D : I P a dd re ss R A D I US _ K EY : R AD I US k ey [ P O R T I D ] : RA DI US p o r t C o m m an d Mo d e C on g ur e mo d e N o / c le a r S h o w s h o w d o t 1x ra d iu s / s ho w r u n ni n g- c on  g D e f a ul t D e s c ri p t io n T h i s c o m ma n d s et s th e r a di u s s e rv e r i p , r ad i us k ey , an d ra d iu s p o r t f o r 8 0 2. 1 X c o n g ur a ti o n . E x a m pl e A S U S (c o n g ) # d ot 1 x r a di u s s e rv e r 1 92 . 1 92 . 1. 1 t e s ti n g 1 81 2 6 . 5  d o t 1 x  r a d i u s  s e c o n d a r y - s e r v e r  A . B . C . D R A D I U S _ K E Y  [ P O R T I D ] S y n t ax d o t 1 x r a di u s s ec o n da r y- s er v e r A . B . C .D RA D I US _ KE Y [ P O R T I D ] P a r a me t e rs A . B . C. D : I P a dd re ss R A D I US _ K EY : R AD I US k ey [ P O R T I D ] : RA DI US p o r t C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w s h o w d o t 1x ra d iu s / s ho w r u n ni n g- c on  g D e f a ul t D e s c ri p t io n T h i s c o m ma n d s et s th e s e co n d ar y r a di u s s e rv e r i p , r ad i us k ey , a n d ra d i us po r t f o r 8 02 . 1X c on  gu r at i o n. E x a m pl e A S U S (c o n g ) # d ot 1 x r a di u s s e co n da r y- s e rv e r 1 92 . 1 92 . 1. 2 t e s t in g 18 1 2
GigaX2024B/M L2 Managed Switch CLI Manual 19 6 . 6  d o t 1 x  r e - a u t h e nt i c a t e  i n te r f a c e  [ I F N AM E ] S y n t ax d o t 1 x r e -a u th e nt i c at e i n te r f ac e [ I FN A M E] P a r a me t e rs I F N A ME : in t er f ac e ’ s n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w s h o w d o t 1x in t er f a ce IF N AM E D e f a ul t D e s c ri p t io n U s e th e do t 1x re a u th e nt i ca t e p r iv i le g e d E XE C c o m ma n d o n t h e sw i t ch st a ck o r o n a s t a nd a lo n e s w it c h t o m a nu a ll y i n i ti a te a r e -a u t he n ti c at i o n o f a ll 8 02 . 1X - en a b le d p o rt s or th e s p e ci  ed 8 0 2 . 1X - e na b le d p o r t. E x a m pl e A S U S (c o n g ) # d ot 1 x r e -a u th e n ti c at e i n t er f ac e f a 1 /0 / 1 6 . 7  d o t 1 x  r e a u t h e n ti c a t i o n S y n t ax d o t 1 x r e au t he n ti c a ti o n P a r a me t e rs r e a u th e n ti c at i on p e r i od i c r e au t he n t ic a ti o n o f t h e c li e n t C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o d ot 1 x r e au t he n t ic a ti o n S h o w s h o w d o t 1x al l / s ho w d o t1 x in t er f ac e IF N AM E D e f a ul t T h e do t 1 x r ea u th e n ti c at i on f ea t ur e i s de f au l t d i sa b le D e s c ri p t io n U s e th e do t 1x re a u th e nt i ca t i on in t er f a ce co n g u r at i on co m m an d o n t he s wi t ch st a c k o r o n a st a nd a lo n e s w it c h t o e n ab l e p e ri o di c r e - a ut h e nt i ca t io n of th e c l i en t . U se t he no fo r m o f t h is c om m an d t o r et u r n t o t he d ef a ul t s e t ti n g. E x a m pl e A S U S (c o n g - if ) # d o t1 x r e au t h en t ic a ti o n 6 . 8  d o t 1 x  s y s t e m - a ut h - c o n t r o l S y n t ax d o t 1 x s y st e m- a ut h - co n tr o l P a r a me t e rs s y s t em - a ut h -c o nt r o l e n a b le d 80 2 .1 X g l o ba l ly C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o d ot 1 x s y st e m- a u th - co n tr o l
GigaX2024B/M L2 Managed Switch CLI Manual 20 S h o w s h o w d o t 1x / s ho w ru n ni n g- c o n g D e f a ul t T h e de f a ul t i s g l o ba l d i sa b l e D e s c ri p t io n U s e th e d o t 1x s y s t em -a ut h - c on tr ol g l ob al c o n gu ra t i o n co mm a n d o n t he s wi t ch st a c k o r o n a st a nd a lo n e s w it c h t o g l ob a ll y en a bl e 8 0 2 . 1X . Us e t h e n o f o rm of t hi s c o mm a n d t o r et u r n t o t he d ef a ul t s e t t in g . E x a m pl e A S U S (c o n g ) # d ot 1 x s y st e m- a u th - co n tr o l 6 . 9  d o t 1 x t i m e o ut  ( r e a u t h -p e r io d |  q u ie t - p e r i o d| t x - p e r i o d | s u p p - t im e o u t | s e rv e r - t i m e o u t ) T I M E V A L U E S y n t ax d o t 1 x t i me o ut (r e a ut h -p e ri o d | q ui e t- p e ri o d| t x- p e ri o d| su p p - t i m e ou t | se r ve r -t i m eo u t) T I M E V A L U E P a r a me t e rs r e a u th - p er i od -> n u m be r o f se c on d s b e tw e en r e a u th e n ti c at i on a tt e mp t s q u i e t- p e ri o d - > n um be r of s ec o nd s t ha t t he s y st em re ma i ns i n t he q ui e t s ta t e f o ll o wi n g a fa i le d au t he n ti c a ti o n e xc h a ng e w i th t h e cl i e nt t x - p er i o d - > n um be r of se c on d s t h at th e sy s te m w a i ts f o r a r e sp o ns e t o an EA P -r e q ue s t/ i de n t it y f r am e fr o m t he c l i e nt b ef o re re t r an s mi t ti n g t h e r eq u e st s u p p -t i m eo u t - > n u m b er o f s ec o nd s th a t t he s ys t em wa i t s f o r a r e sp o ns e f r o m A u t h e nt i ca t o r t o S up p l ic a nt s e r v er - t im e ou t - > n u m b er o f s ec o nd s th a t t he s ys t em wa i t s f o r a r e sp o ns e f r o m A u t h e nt i ca t o r t o A u t h e nt i c at i on Se r v er T I M E V AL UE : 1 ~6 55 3 5 s ec o nd s C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o d ot 1 x t i me o ut ( qu i et - pe r i od | r e au t h -p e ri o d| s er v er - ti m e ou t | s u p p -t i m eo u t| tx - p er i od ) S h o w s h o w d o t 1x al l / s ho w d o t1 x in t er f ac e IF N AM E D e f a ul t r e a u th - p er i od : 3 6 00 se c on d s q u i e t- p e ri o d: 60 s ec o nd s t x - p er i o d: 30 se c o nd s s u p p -t i m eo u t: 30 s ec o nd s
GigaX2024B/M L2 Managed Switch CLI Manual 21 s e r v er - t im e ou t : 2 0 s e co n ds D e s c ri p t io n T h i s c o m ma n d s et s th e d o t1 x re a ut h en t i ca t io n t i m er . E x a m pl e A S U S (c o n g - if ) # d o t1 x t i me o u t r ea u th - p er i od 36 0 0 6 . 1 0  d o t 1 x h o s t - m o d e ( m u l t i - h o s t | s i n g l e - h os t ) S y n t ax d o t 1 x h o st - mo d e ( m ul t i- h os t | s i ng l e- h o st ) P a r a me t e rs m u l t i- h o st : E n ab l e m u lt i pl e - ho s ts mo d e o n t h e s w it c h s i n g le - h os t : E na b l e s in g le - h os t m o de o n t he sw i t ch C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o d ot 1 x h o st - mo d e S h o w s h o w d o t 1x al l / s ho w d o t1 x in t er f ac e IF N AM E D e f a ul t s i n g le - h os t D e s c ri p t io n A l l o w m u lt i pl e h o s ts (c l ie n t s) on an 8 02 . 1X - au t h or i ze d p o r t. E x a m pl e A S U S (c o n g - if ) # d o t1 x h o st - m od e m u lt i - ho s t 6 . 1 1  d o t 1 x  a u t h e n t i c- m e t h o d  ( lo c a l  |  r a d i us ) S y n t ax d o t 1 x a u th e nt i c- m e th o d ( lo c a l | r a di u s ) P a r a me t e rs L o c a l: U se th e l o c al us e rn a m e d at a ba s e f o r a ut h e nt i ca t io n R a d i us : Us e t h e R e mo t e A u t h e nt i c at i on Di a l -I n U s er S er v ic e ( R A D IU S ) s e rv e rs f or au t he n t ic a ti o n C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o d ot 1 x a u th e nt i c -m e th o d S h o w s h o w d o t 1x au t he n t ic _ me t ho d D e f a ul t r a d i us D e s c ri p t io n S p e c if y th e a u th e n ti c m e th o d f o r A A A . E x a m pl e A S U S (c o n g ) # d ot 1 x a u th e nt i c -m e th o d r a di u s 6 . 1 2  d o t 1 x u s e r  W O R D P A S SW O R D  < 1 - 3 00 0 > S y n t ax d o t 1 x u s er WO R D P A S S W O R D < 1- 3 00 0 >
GigaX2024B/M L2 Managed Switch CLI Manual 22 P a r a me t e rs F i r s t W O RD : U se r Na m e Se co nd W O R D : U s er P as s wo r d C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o d ot 1 x u s er n am e WO R D S h o w s h o w d o t 1x us e rn a m e D e f a ul t N / A D e s c ri p t io n A d d us e r i n to lo c a l r ad i us d at a ba s e. E x a m pl e A S U S (c o n g ) #d o t1 x us e r t es t te s ti n g1 2 3 1 6 . 1 3  s h o w  do t 1 x S y n t ax s h o w d o t 1x P a r a me t e rs d o t 1 x G e t I EE E 80 2 .1 x i n f or m at i on C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w d ot 1 x p r iv i le g e d E XE C c o m ma n d t o d i sp l ay 8 0 2 . 1X st a ti s ti c s, ad m in i st r at i ve st a tu s , a nd op e ra t io n a l s ta t us fo r t h e sw i t ch or fo r th e s p ec i  ed in t er f a ce . E x a m pl e A S U S #s h o w d ot 1 x 6 . 1 4  s h o w  do t 1 x  i n t e rf a c e  I F N A M E S y n t ax s h o w d o t 1x in t er f a ce IF N AM E P a r a me t e rs i n t e rf a c e i nt er fa c e n u mb e r [ I F N AM E ] d es ig n at e s t h e m od u le a nd po r t n u mb e r e x : gi g i bi t et h er n e t1 / 0/ 3 , g i ga b it e th e r ne t 0/ 2 5. . . C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w d ot 1 x p r iv i le g e d E XE C c o m ma n d t o d i sp l ay 8 0 2 . 1X s ta t is t ic s , a d mi n is t r at i ve st a t us , a n d o p er a ti o na l st a tu s f o r th e sw i tc h o r fo r t h e s p ec i e d i n t er f ac e . D i sp l ay th e 80 2 .1 X s t a t us f or th e s p e ci  ed in t e rf a ce (i n c lu d in g t y p e , s t ac k m e mb e r , m o du l e, an d po r t n um b e r) .
GigaX2024B/M L2 Managed Switch CLI Manual 23 E x a m pl e A S U S #s h o w d ot 1 x i n te r fa c e f a 1/ 0 /1 6 . 1 5  s h o w  do t 1 x  r a d i us S y n t ax s h o w d o t 1x ra d iu s P a r a me t e rs r a d i us R e mo t e A c ce s s D ia l - In Us e r S e rv i ce C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w d ot 1 x r a di u s p r iv i le g ed E XE C c o mm a n d t o d i s p la y 80 2 .1 X R e m ot e A c ce s s D i al - In Us e r S e rv i ce s ta t is t ic s , a d m i ni s t ra t iv e s t a tu s , a nd o pe r at i on a l s t at u s f o r t he sw i t ch or fo r t h e sp e c i e d i nt e r fa c e. E x a m pl e A S U S #s h o w d ot 1 x r a di u s 6 . 1 6    s h o w  do t 1 x  u s e r S y n t ax s h o w d o t 1x us e r P a r a me t e rs N / A C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N / A D e s c ri p t io n U s e th e sh o w d ot 1 x u s er n am e pr i vi l eg e d E X EC co m m an d t o d i s p la y th e u s er n a me in lo c a l d at a ba s e . E x a m pl e A S U S # s h ow do t 1x u se r 7. Mirror 7 . 1 m i r r o r s e s s i o n < 1 - 8 > d e s ti n a t i o n I F N AM E S y n t ax m i r r or s es s io n < 1 - 1> de s ti n a ti o n I FN A M E P a r a me t e rs [ I F N AM E ] d es i gn a t es th e m o d ul e a n d p o rt nu m be r ex : f a s t et h e rn e t1 / 0/ 3 , g i ga b it e t he r ne t 1/ 0 / 25 . .. C o m m an d Mo d e C on g ur a t io n m o de
GigaX2024B/M L2 Managed Switch CLI Manual 24 N o / c le a r N o m ir r o r s es s io n <1 - 8> D e f a ul t D i s a bl e D e s c ri p t io n T o s e t mo n it o r p o rt in mi r r or mo d e E x a m pl e A S U S (c o n g ) # m ir r o r s es s io n 1 d es t in a t io n f a 1/ 0 / 1 7 . 2 m i r r o r s e s s i o n < 1 - 8 > s o u r c e I F L I S T ( r x | t x | b o t h ) ) S y n t ax m i r r or s es s io n < 1 - 8> so u rc e IF L IS T ( r x | tx | bo t h ) P a r a me t e rs I F L I ST s o u r ce i nt e rf a ce l is t , e x f a 1/ 0 /1 , fa i 1 /0 / 3- 5 ,g i 1 /0 / 26 b o t h - > re ce iv ed a nd tr a ns m i tt e d t ra f  c r x - > r e c e iv e d t r af  c t x - > t r a n sm i t te d t r af  c C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o m ir r o r s es s io n 1 s ou r ce f a1 / 0/ 2 -4 S h o w s h o w m i r ro r p o rt / s h ow ru n n in g -c o n g D e f a ul t N o m ir r o r r ul e i s se t ti n g D e s c ri p t io n T h i s c o m ma n d m ir r o rs th e s o u rc e i n te r f ac e l i st t ra f c to t he d e s t in a t io n i n te r f ac e . Th e mi rr o r t yp e s u p po r t r ec e i ve d t r af  c , T r a ns m it t ed t ra f c , o r bo t h. E x a m pl e A S U S (c o n g ) #m i rr o r s e ss i on 1 s o ur c e f a 1/ 0 /2 - 4 7 . 3 s h o w m i r r o r s e ss i o n S y n t ax S h o w m i r ro r s e ss i o n P a r a me t e rs m i r r or m ir r or i n g f ea t ur e C o m m an d Mo d e P ri vi li e d ge mo d e D e f a ul t D e s c ri p t io n T o s h o w c u rr e nt m ir r or fe a t ur e s E x a m pl e A S U S #s h o w m ir r or s es s io n
GigaX2024B/M L2 Managed Switch CLI Manual 25 7 . 4 n o m i r r o r s e s s io n < 1 - 8 > so u r c e I F L I S T S y n t ax n o m ir r o r s es s io n <1 - 8> so u r ce IF L IS T P a r a me t e rs n o N eg at e a co m m an d o r s e t i t s d ef a u lt s I F L I ST so ur c e i nt e r fa c e l is t ,e x f a 1/ 0 / 1, f a1 / 0/ 3 - 5, f ai 1 /0 / 7 C o m m an d Mo d e C on g ur e te r mi n al m od e S h o w s h o w m i r ro r s e ss i o n D e f a ul t T h e r e a r e s om e m i r ro r in g r u l es on Sw i t ch . D e s c ri p t io n T h i s c o m ma n d r es e t s t he so u r ce in t er f a ce s ’ r ec e i ve d o r t r a n sm i t te d t r af  c o r b o th t he de s ti n a ti o n i nt e r fa c e. E x a m pl e A S U S (c o n g ) #n o m i r ro r s e ss i o n 1 s o ur c e f a 1/ 0 /2 - 4 8. QoS/CoS 8 . 1  c o s  c o s - m a p  P R IO R I T Y  Q U E U E G X 2 0 24 B Qu e ue ra n g e i s 1 -4 S y n t ax c o s co s - ma p < 0 -7 > <1 - 6> P a r a me t e rs P R I O RI T Y 8 0 2 . 1p pr i o ri t y Q U E U E in t er n al c la s s o f s e rv i ce qu e u es C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o c os c os - ma p S h o w s h o w c o s c o s- m ap D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e qu e ue co s - ma p c o n g u ra t io n c o m ma n d o n t h e s wi t ch s t a c k o r s t an d al o n e s wi t ch t o s et wh i c h C os qu e u e a g i ve n p r i o ri t y s h ou l d m a p i nt o . E x a m pl e A S U S (c o n g ) #c o s c o s- m ap 3 1 8 . 2 s h o w c o s c o s - m ap S y n t ax s h o w c o s c o s- m ap
GigaX2024B/M L2 Managed Switch CLI Manual 26 P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n S h o w w h i ch co s q u e ue ag i ve n pr i or i ty c ur r en t m a p s t o E x a m pl e A S U S # s h ow co s c o s -m a p 8 . 3 cos policy wrr-queue weight <1-10> <1-10> < 1 - 1 0 > < 1 - 1 0 > <1 - 1 0 > < 1 - 10 > G X 2 0 24 B Qu e ue we i g ht pa r am e t er is 4. S y n t ax c o s po l i cy wr r -q u e ue we i gh t <1 - 10 > < 1 - 10 > < 1 -1 0 > < 1 -1 0 > < 1 - 1 0> < 1- 1 0> P a r a me t e rs < 1 - 1 0> we ig ht fo r co s q u eu e 1 < 1 - 1 0> we ig ht fo r co s q u eu e 2 < 1 - 1 0> we ig ht fo r co s q u eu e 3 < 1 - 1 0> we ig ht fo r co s q u eu e 4 < 1 - 1 0> we ig ht fo r co s q u eu e 5 < 1 - 1 0> we ig ht fo r co s q u eu e 6 C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o i ng r e ss - qu e ue c os - ma p S h o w s h o w q o s w r r- q ue u e w e ig h ts D e f a ul t D e s c ri p t io n T h i s c o m ma n d s ho w th e w e ig h t f o r e ac h co s q u eu e E x a m pl e A S U S (c o n g ) #c o s p o li c y w rr - q ue u e w ei g h t 2 3 4 5 6 7 8 . 4 c o s p o l i c y s t r ic t S y n t ax c o s po l i cy st r ic t P a r a me t e rs h i g h _ r s t A l l H ig h be f or e L o w
GigaX2024B/M L2 Managed Switch CLI Manual 27 C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r N o l ow - q ue u e d el a y b o un d S h o w s h o w q o s m o de D e f a ul t T h e de f a ul t s e tt i n g o f q os m od e i s h i g h r st mo d e D e s c ri p t io n T h i s c o m ma n d s et s qo s m o de t o h ig h r s t m o de E x a m pl e A S U S (c o n g ) # c os p ol i cy st r i ct 8 . 5 s h o w c o s p o l i c y S y n t ax s h o w c o s p o li c y P a r a me t e rs q o s q u a l it y of se r vi c e ( Q oS ) m o d e C o S S c h ed u li n g m o de of IE E E 8 0 2. 1 p C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r n o m ax b ri d ge tr a n sm i t d el a y b o un d S h o w s h o w m a x b r id g e t r an s mi t d e l ay bo u nd D e f a ul t D e s c ri p t io n T h i s c o m ma n d s ho w th e q o s m o de . E x a m pl e A S U S # s h ow co s p o l ic y 8 . 6 s h o w q o s e g r e s s b a n d w i d t h [ I F N A M E ] S y n t ax s h o w q o s e g re s s b a nd w id t h [ I FN A ME ] P a r a me t e rs e g r e ss Eg re ss k ey w or d [ I F N AM E ] I nt er f ac e ’s n am e , e x: f a1 / 0/ 1 o r fa 1 /0 / 12 C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n T h i s c o m ma n d u se d to sh o w t h e Q os ba n d wi d th in f o rm a ti o na l p a r a me t e r f or th e ou t co m in g pa c ke t s. E x a m pl e A S U S # s h ow qo s e g r es s b a nd w i dt h f a 1/ 0 / 1
GigaX2024B/M L2 Managed Switch CLI Manual 28 8 . 7 s h o w q o s I n g r e ss b a n d w i d th [ I F N A M E ] S y n t ax s h o w q o s i n gr e ss b an d wi d th [ IF N AM E ] P a r a me t e rs i n r e ss in gr es s k ey w or d [ I F N AM E ] I nt er f ac e ’s n am e , e x: f a1 / 0/ 1 o r fa 1 /0 / 12 C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n T h i s c o m ma n d u se d to sh o w t h e Q os ba n d wi d th in f o rm a ti o na l p a r a me t e r f or th e ou t co m in g pa c ke t s. E x a m pl e A S U S # s h ow qo s i n g re s s b an d w id t h f a1 / 0 /1 8 . 8 q o s e g r e s s b a n dw i d t h < 1 - 10 0 0 > G X 2 0 24 B do e sn ’ t s u pp o rt th i s f u nc t io n . S y n t ax q o s eg r e ss ba n dw i d th <1 - 10 0 0 > P a r a me t e rs e g r e ss Ou tg oi n g p a ck e ts b a n d wi d t h Se t b an d wi d th i nf o rm a ti o n al pa r am e t er < 1 - 1 00 0 > Li mi t i n 64 - ki l o- b i ts pe r s e c on d C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o q os e gr e ss ba n d wi d th S h o w s h o w q o s e g re s s b a nd w id t h [ I FN A ME ] D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n T h i s c o m ma n d u se d to se t t h e Q o s b an d w id t h i nf o r ma t io n al p a r a me t e r f or th e ou t co m in g pa c ke t s. E x a m pl e A S U S (c o n g - if ) # q o s e gr e ss b an d wi d th 2 0 8 . 9 n o q o s e g r e s s ba n d w i d t h G X 2 0 24 B do e sn ’ t s u pp o rt th i s f u nc t io n . S y n t ax n o q os e gr e ss ba n d wi d th
GigaX2024B/M L2 Managed Switch CLI Manual 29 P a r a me t e rs e g r e ss Ou tg oi n g p a ck e ts b a n d wi d t h Se t b an d wi d th i nf o rm a ti o n al pa r am e t er C o m m an d Mo d e I nt er fa c e m o de N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n T h i s c o m ma n d u se d to di s ab l e t h e Q os b an d wi d th i nf o rm a ti o n al p a r a me t e r f or th e ou t co m in g pa c ke t s. E x a m pl e A S U S (c o n g - if ) #n o qo s e g re s s b a nd w id t h 8 . 1 0 q o s i ng r e s s b a n dw i d t h < 1 - 1 0 00 > S y n t ax q o s in g r es s b a nd w i dt h < 1 -1 0 0 0> P a r a me t e rs i n g r es s In go in g p a ck e t s b a n d wi d t h Se t b an d wi d th i nf o rm a ti o n al pa r am e t er < 1 - 1 00 0 > Li mi t i n ma g ab i ts p er se c on d (G X 20 2 4B ) < 1 - 1 00 0 > 64 -k i lo - b it s p e r s e co n d ( GX 2 0 24 M ) C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o q os i ng r es s b a n dw i dt h S h o w s h o w q o s i n gr e ss b an d wi d th [ IF N AM E ] D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n T h i s c o m ma n d u se d to se t t h e Q o s b an d w id t h i nf o r ma t io n al p a r a me t e r f or th e ou t co m in g pa c ke t s. E x a m pl e A S U S (c o n g - if ) # q o s i ng r es s ba n dw i dt h 20 8 . 1 1 n o q o s i n g r e s s b a n d w i d t h S y n t ax n o q os i ng r es s b a n dw i dt h P a r a me t e rs i n g r es s In go in g p a ck e t s b a n d wi d t h Se t b an d wi d th i nf o rm a ti o n al pa r am e t er C o m m an d Mo d e I nt er fa c e m o de N o / c le a r
GigaX2024B/M L2 Managed Switch CLI Manual 30 S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n T h i s c o m ma n d u se d to di s ab l e t h e Q os b an d wi d th i nf o rm a ti o n al p a r a me t e r f or th e ou t co m in g pa c ke t s. E x a m pl e A S U S (c o n g - if ) #n o qo s i n gr e s s b an d wi d t h 8 . 1 2  c o s  p ol i c y   f o S y n t ax c o s po l i cy f o P a r a me t e rs F c f s  r s t c om e  s r t s er v ic e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r N o l ow - q ue u e d el a y b o un d S h o w s h o w q o s m o de D e f a ul t T h e de f a ul t s e tt i n g o f q os m od e i s h i g h r st mo d e D e s c ri p t io n T h i s c o m ma n d s et s qo s m o de t o f cf s m o d e E x a m pl e A S U S (c o n g )# c os p ol i cy f o 8 . 1 3 n o c o s p o l i c y S y n t ax n o c os p ol i cy P a r a me t e rs C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w s h o w q o s m o de D e f a ul t T h e de f a ul t s e tt i n g o f q os m od e i s h i g h r st mo d e D e s c ri p t io n T h i s c o m ma n d s et s qo s m o de t o h ig h r s t m o de E x a m pl e A S U S # n o c o s p ol i c y 9. Storm control 9 . 1  s t o r m - c o n t r o l  ( b r o a d c a s t | d l f | m u l t i c a s t ) 
GigaX2024B/M L2 Managed Switch CLI Manual 31 < 1 - 2 6 2 1 4 3 > S y n t ax s t o r m- c o nt r ol (b r o ad c as t |d l f |m u lt i ca s t ) < 1- 2 62 1 4 3> P a r a me t e rs b r o a dc a s t B ro ad ca s t p a ck e ts d l f D e s t in a ti o n L o ok u p F a il u re m u l t ic a s t Mu l ti c as t pa c ke t s L I M I T_ R A T E v a l u e 1 ~ 26 2 14 3 ( p a ck e ts / s) C o m m an d Mo d e I nt er fa ce m o d e (G X2 02 4M )/ C on g ur e te rm in al m od e( GX 20 24 B) N o / c le a r n o s to r m -c o nt r ol ( br o ad c as t | dl f |m u lt i c as t ) S h o w s h o w s t o rm - co n tr o l I F NA M E ( b ro a dc a st | d lf | mu l ti c a st ) D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e st o rm - co n t ro l c o n g u ra t io n c o m ma n d o n t h e s wi t ch s t a c k o r s t an d al o n e s wi t ch t o s et th e li m it ra t e o f t h e p o rt ’ s t ot a l b a n d wi d t h u se d b y br o ad c as t / dl f /m u lt i c as t . E x a m pl e A S U S (c o n g - if ) # s t or m -c o nt r o l m ul t ic a s t 4 09 6 9 . 2  n o  s t o r m - c o n t r ol  ( b r o a d c as t | d l f | m u l t ic a s t ) S y n t ax n o s to r m -c o nt r ol ( br o ad c as t | dl f |m u lt i c as t ) P a r a me t e rs b r o a dc a s t B ro ad ca s t p a ck e ts d l f D e s t in a ti o n L o ok u p F a il u re m u l t ic a s t Mu l ti c as t pa c ke t s C o m m an d Mo d e I nt er fa c e m o de N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e no st o rm - c on t ro l c o n g u ra t io n co m ma n d o n t h e s wi t c h s t a c k o r s t an d al o n e s wi t ch t o d is a bl e th e l i mi t ra t e o f t h e p or t ’s t o t a l b a nd w id t h u s ed by br o a dc a st / dl f / mu l ti c as t . E x a m pl e A S U S (c o n g - if ) #n o st o rm - co n t ro l m u lt i c as t
GigaX2024B/M L2 Managed Switch CLI Manual 32 9 . 3  s h o w  s t o r m - c o n tr o l  ( b r o a dc a s t | d l f | m u lt i c a s t ) S y n t ax s h o w s t o rm - co n tr o l ( b ro a dc a s t| d lf | mu l t ic a st ) P a r a me t e rs b r o a dc a s t B ro ad ca s t p a ck e ts d l f D e s t in a ti o n L o ok u p F a il u re m u l t ic a s t Mu l ti c as t pa c ke t s C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t D e s c ri p t io n U s e th e sh o w s to r m -c o nt r ol c on  gu r at i o n c om m an d on th e s w i t ch s ta c k o r s t an d al o ne s wi t ch to s ho w t h e l i mi t r a te o f t he p o r t ’s t ot a l b an d w id t h u se d by br o ad c a st / dl f /m u l ti c as t . E x a m pl e A S U S # s h ow st o rm - c on t ro l d l f 10. M A C a d d r e s s m a n a g e m e n t Conguration: 1 0 . 1 c l e a r m a c - a d d r e s s - t a b l e d y n a m i c v l a n < 1 - 3 0 0 0 > S y n t ax c l e a r m a c- a dd r es s - ta b le dy n a mi c v l an < 1- 3 00 0 > P a r a me t e rs d y n a mi c dy na m i c L 2 M AC a dd r es s es i n t he d a t a ba s e < 1 - 3 00 0 > vl a n i d C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e wr i te co n  gu r at i on c om m an d o n th e s w it c h s t ac k o r s t a n da l o ne sw i tc h to cl e ar d yn a mi c L 2 MA C a d dr e s se s i n t h e
GigaX2024B/M L2 Managed Switch CLI Manual 33 d a t a ba s e . E x a m pl e A S U S (c o n g ) # c le a r m a c- a dd r e ss - ta b le d yn a mi c v l a n 1 1 0 . 2 m a c - a dd r e s s - t a b le a g i n g - t i m e T I M E V A L U E S y n t ax m a c - ad d r es s -t a bl e ag i ng - ti m e T I M EV AL UE P a r a me t e rs a g i n g- t i me t he l e ng t h o f t i me th a t a dy n am i c e n tr y r e m a in s in th e M A C a d dr e ss t ab l e T I M E V AL UE A g i n g t i me in se c o nd s ( 1 0~ 1 0 00 0 00 ) C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o m ac - a dd r es s -t a b le ag i ng - t im e S h o w s h o w m a c -a d dr e ss - t ab l e a gi n g -t i me D e f a ul t T h e de f a ul t i s 3 0 0 s e co n ds . D e s c ri p t io n U s e th e ma c -a d dr e s s- t ab l e a g in g -t i me c on  gu r at i o n c om m an d o n t he s wi t ch st a c k o r o n a st a nd a lo n e s w it c h t o s e t t he l en g th o f t im e th a t a d y n am i c e nt r y r e ma i ns i n t he MA C ad d re s s t a bl e a f t e r t h e e nt r y i s u s ed or u pd a te d . T h e re a l a g in g -t i m e i s t he t ri p le of t he co m ma n d i n pu t r a d ix n u m b er . E x a m pl e A S U S (c o n g ) # m ac - a dd r es s -t a b le ag i ng - t im e 3 0 0 1 0 . 3 n o m a c- a d d r e s s - ta b l e a g i n g - ti m e S y n t ax n o m ac - a dd r es s -t a b le ag i ng - t im e P a r a me t e rs a g i n g- t i me t he l e ng t h o f t i me th a t a dy n am i c e n tr y r e m a in s in th e M A C a d dr e ss t ab l e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w D e f a ul t D e s c ri p t io n U s e th e no ma c -a d d re s s- t ab l e a g in g -t i m e c on  gu r a ti o n c o m m an d on th e s w i tc h s t ac k or on a s t an d al o ne s wi t ch to d i s a bl e dy n am i c e n tr y r e ma i n s i n t he M AC ad d re s s t a bl e a f t er t h e en t r y i s u se d or up d at e d .
GigaX2024B/M L2 Managed Switch CLI Manual 34 T h e re a l a g in g -t i m e i s t he t ri p le of t he co m ma n d i n pu t r a d ix n u m b er . E x a m pl e A S U S (c o n g ) # n o m a c- a dd r es s - ta b le ag i n g- t im e 1 0 . 4 s h o w ma c - a d d r e s s- t a b l e a g i n g- t i m e S y n t ax s h o w m a c -a d dr e ss - t ab l e a gi n g -t i me P a r a me t e rs a g i n g- t i me t h e l e ng t h o f t i me th a t a dy n am i c e n tr y r e ma i n s i n t h e MA C ad d re s s t a bl e C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t D e s c ri p t io n U s e th e sh o w m ac - a dd r es s -t a b le ag i ng - t im e c o n g u ra t io n c o m m an d on th e s w i tc h s t ac k or on a s t an d al o ne s wi t ch to s ho w d y n a mi c en t ry re m a in s i n t h e M A C a dd r e ss ta b le a ft e r t he e nt r y i s u se d or up d at e d . T h e re a l a g in g -t i m e i s t he t ri p le of t he co m ma n d i n pu t r a d ix n u m b er . E x a m pl e A S U S # s h ow ma c -a d d re s s- t ab l e a g in g -t i m e 1 0 . 5 ma c - a dd re ss -t ab le s t a ti c M AC AD DR V L A NI D I F N A M E S y n t ax m a c - ad d r es s -t a bl e st a ti c M A C _A D DR VL A N ID IF N AM E P a r a me t e rs s t a t ic S ta ti c k e yw o rd M A C A DD R D e s t in a t io n M A C a d dr e ss xx x x .x x xx . xx x x ( m u l ti c a st ) t o t h e a d dr e ss t ab l e V L A N ID V al id r a n ge is 1 ~ 30 0 0 I F N A ME I n t e rf a c e’ s n a me , ex : f a 1/ 0 / 1 o r f a1 / 0 /1 2 C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o m ac - a dd r es s -t a b le st a ti c MA C AD D R V L AN I D I FN A M E S h o w s h o w m a c -a d dr e ss - t ab l e s ta t i c
GigaX2024B/M L2 Managed Switch CLI Manual 35 D e f a ul t N o s ta t i c a dd r es s e s a re co n  gu r ed . D e s c ri p t io n U s e th e ma c -a d dr e s s- t ab l e s t at i c c on  g ur a ti o n c o mm a nd on t h e sw i t ch st a ck o r o n a s t a nd a lo n e s w it c h t o a d d u ni c as t st a ti c a d d r es s e s t o t he M AC ad d re s s t a bl e . E x a m pl e A S U S (c o n g ) # m ac - a dd r es s -t a b le st a ti c 00 0 0. 0 00 0 . 00 0 1 2 f a 1 / 0/ 2 1 0 . 6 m a c -a dd r e s s- ta b l e mu l t i ca st M A CA DD R vl an V L A N I D  i n t e r f a ce  I F L I S T  CO S _ D E S T S y n t ax m a c - ad d r es s -t a bl e mu l ti c as t MA C AD D R v l an VL A NI D in t er f ac e I F L I ST C OS _D ES T P a r a me t e rs m u l t ic a s t M u l ti c as t M A C A DD R D e s t in a t io n M A C a d dr e ss xx x x .x x xx . xx x x ( m u l ti c a st ) t o t h e a d dr e ss t ab l e v l a n V la n V L A N ID V al id r a n ge is 1 ~ 30 0 0 i n t e rf a c e th e sp e ci  ed i nt e rf a ce I F N A ME I n t e rf a c e’ s n a me , ex : f a 1/ 0 / 1 o r f a1 / 0 /1 2 C O S _ DE S T C O S pr i o ri y t C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w D e f a ul t N o s ta t i c a dd r es s e s a re co n  gu r ed . D e s c ri p t io n U s e th e ac - ad d re s s -t a bl e m u l ti c as t c o n g u ra t io n co m ma n d o n t h e sw i t ch st a ck o r o n a s t a nd a lo n e s w it c h t o a d d m ul t ic a s t s ta t ic a d d r es s e s t o t he M AC ad d re s s t a bl e . E x a m pl e A S U S (c o n g ) # m ac - a dd r es s -t a b le mu l ti c a st 01 0 0. 5 e 0a . 0a 0 a v l a n 1 i nt e rf a ce f a1 / 0/ 2 -5 3 1 0 . 7 no mac-address-t able multicast MACADDR v l a n  V L A N I D  i n te r f a c e  I F LI S T  C O S _ D ES T S y n t ax n o m ac - a dd r es s -t a b le mu l ti c a st MA C AD D R v l an VL A N ID
GigaX2024B/M L2 Managed Switch CLI Manual 36 i n t e rf a c e I FL I ST C OS _D ES T P a r a me t e rs m u l t ic a s t M u l ti c as t M A C A DD R D e s t in a t io n M A C a d dr e ss xx x x .x x xx . xx x x ( m u l ti c a st ) t o t h e a d dr e ss t ab l e v l a n V la n V L A N ID V al id r a n ge is 1 ~ 30 0 0 i n t e rf a c e th e sp e ci  ed i nt e rf a ce I F L I ST In te r fa c e’ s n a m e l is t , e x : f a1 / 0/ 1 - 12 C O S _ DE S T C o s pr i o ri t y C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w D e f a ul t N o s ta t i c a dd r es s e s a re co n  gu r ed . D e s c ri p t io n U s e th e no ma c -a d d re s s- t ab l e m u lt i ca s t c o n g ur a t io n c o mm a n d o n t he s wi t ch st a c k o r o n a st a nd a lo n e s w it c h t o r e mo v e m u l t ic a s t s ta t ic p or t t o t h e M A C a dd r e ss ta b le . E x a m pl e A S U S (c o n g ) # n o m a c- a dd r es s - ta b le mu l t ic a st 01 0 0 .5 e 0a . 0a 0 a v l a n 1 i nt e rf a ce f a1 / 0/ 2 -5 3 1 0 . 8 s h o w ma c - a d d r e s s- t a b l e m u l t ic a s t S y n t ax s h o w m a c -a d dr e ss - t ab l e m ul t i ca s t P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac - a dd r es s -t a b le mu l ti c a st us e r E X EC c o m m an d to di s pl a y t h e L ay e r 2 mu l ti c a st en t ri e s f o r a ll V LA N s. U s e th e co m ma n d i n p r iv i le g e d E XE C m o d e t o d is p l ay sp e ci  c m u l t ic a s t e nt r ie s . E x a m pl e A S U S # s h ow ma c -a d d re s s- t ab l e m u lt i ca s t
GigaX2024B/M L2 Managed Switch CLI Manual 37 1 0 . 9 s h o w m a c - a d d r e s s - t a b l e s t a t i c m a c [ M A C _ A D D R ] S y n t ax s h o w m a c -a d dr e ss - t ab l e s ta t i c m ac [M A C _A D DR ] P a r a me t e rs [ M A C _A D D R] MA C a d d re s s C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac - a dd r es s -t a b le uc a st s ta t ic us e r E X EC c o m m an d to di s pl a y s t at i c/ d y na m ic uc a s t M AC ad d r es s t a bl e e n t r ie s on l y . E x a m pl e A S U S # s h ow ma c -a d d re s s- t ab l e s t at i c m a c 0 00 0 .0 0 0 0. 0 00 1 1 0 . 1 0  s h o w  m a c - a d d r e s s - t a b l e  s t a t i c  i n t e r f a c e  [ I F N A M E ] S y n t ax s h o w m a c -a d dr e ss - t ab l e s ta t i c i nt e rf a c e [ IF N AM E ] P a r a me t e rs [ I F N AM E ] I n t e rf a ce ’ s n a me C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac - a dd r es s -t a b le uc a st s ta t ic us e r E X EC c o m m an d to di s pl a y s t at i c u c as t M A C a d dr e ss ta b l e e nt r ie s on l y . E x a m pl e A S U S # s h ow ma c -a d d re s s- t ab l e s t at i c i n te r fa c e f a 1/ 0 /1 1 0 . 1 1 s h o w m a c - a d dr e s s - t a b l e st a t i c v l a n [V L A N I D ] S y n t ax s h o w m a c -a d dr e ss - t ab l e s ta t i c v la n [ V L AN I D] P a r a me t e rs [ V L A NI D ] v l an ra n g e ( 1~ 3 00 0 ) C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac - a dd r es s -t a b le uc a st s ta t ic us e r E X EC c o m m an d to di s pl a y s t at i c/ d y na m ic uc a s t M AC ad d r es s t a bl e e n t r ie s on l y . E x a m pl e A S U S # s h ow ma c -a d d re s s- t ab l e s t at i c v l an 1
GigaX2024B/M L2 Managed Switch CLI Manual 38 1 0 . 1 2 s h o w m a c - a d d r e s s -t a b l e s t a ti c S y n t ax s h o w m a c -a d dr e ss - t ab l e s ta t i c P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac - a dd r es s -t a b le uc a st s ta t ic us e r E X EC c o m m an d to di s pl a y s t at i c u c as t M A C a d dr e ss ta b l e e nt r ie s on l y . E x a m pl e A S U S # s h ow ma c -a d d re s s- t ab l e s t at i c 1 0 . 1 3 s h o w m a c - a d d r e s s -t a b l e S y n t ax s h o w m a c -a d dr e ss - t ab l e P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac - a dd r es s -t a b le us e r E X EC co m ma n d t o d i s p la y st a ti c /d y n am i c u ca s t M A C a dd r e ss ta b le e nt r ie s o n l y . E x a m pl e A S U S # s h ow ma c -a d d re s s- t ab l e 1 0 . 1 4 s h o w m a c - a d d r e s s - t a b l e m u lt i c as t M A C A D D R v l a n V L A N I D S y n t ax s h o w m a c -a d dr e ss - t ab l e m ul t i ca s t M AC A D DR vl a n V L AN I D P a r a me t e rs m u l t ic a s t M u l ti c as t M A C A DD R D e s t in a t io n M A C a d dr e ss xx x x .x x xx . xx x x ( m u l ti c a st ) t o t h e a d dr e ss t ab l e v l a n V la n V L A N ID V al id r a n ge is 1 ~ 30 0 0 C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac - a dd r es s -t a b le mu l ti c a st us e r E X EC c o m m an d to di s pl a y t h e L ay e r 2 mu l ti c a st en t ri e s f o r a V L A N.
GigaX2024B/M L2 Managed Switch CLI Manual 39 U s e th e co m ma n d i n p r iv i le g e d E XE C m o d e t o d is p l ay sp e ci  c m u l t ic a s t e nt r ie s . E x a m pl e A S U S # s h ow ma c -a d d re s s- t ab l e m u lt i ca s t 0 1 00 . 5e 0 a .0 a 0a vl a n 1 1 0 . 1 5 s h o w m a c - a d d r e s s -t a b l e d y n am i c S y n t ax s h o w m a c -a d dr e ss - t ab l e d yn a m ic P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac - a dd r es s -t a b le uc a st d yn a mi c u s e r E XE C c o m m an d to di s pl a y s t at i c u c as t M A C a d dr e ss ta b l e e nt r ie s on l y . E x a m pl e A S U S # s h ow ma c -a d d re s s- t ab l e d y na m ic 1 0 . 1 6  show mac-address-table dynamic interface  [ I F N A M E ] S y n t ax s h o w m a c -a d dr e ss - t ab l e d yn a m ic in t er f a ce [I F NA M E ] P a r a me t e rs [ I F N AM E ] I n te r fa c e ’s na m e C o m m an d Mo d e P r i v il e g ed EX E C m o de D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac - a dd r es s -t a b le uc a st d yn a mi c c u s er EX E C c o m m an d to di s pl a y d y na m ic u ca s t M AC a dd r es s t a b le en t ri e s o n l y . E x a m pl e A S U S # s h ow ma c -a d d re s s- t ab l e d y na m ic i nt e rf a ce f a1 / 0/ 1 1 0 . 1 7 s h o w m a c - a d d r e s s - t a b l e d y n a m i c m a c [ M A C _ A D D R ] S y n t ax s h o w m a c -a d dr e ss - t ab l e d yn a m ic ma c [ M A C_ A DD R ] P a r a me t e rs [ M A C _A D D R] MA C a d d re s s C o m m an d Mo d e P r i v il e g ed EX E C m o de
GigaX2024B/M L2 Managed Switch CLI Manual 40 D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac - a dd r es s -t a b le uc a st d yn a mi c u s e r E XE C c o m m an d to di s pl a y d y na m ic u ca s t M AC a dd r es s t a b le en t ri e s o n l y . E x a m pl e A S U S # s h ow ma c -a d d re s s- t ab l e d y na m ic m ac 00 0 0. 0 0 00 . 00 0 1 1 0 . 1 8 s h o w m a c - a d d r e s s - t a b l e d y n a m i c v l a n [ V L A N I D ] S y n t ax s h o w m a c -a d dr e ss - t ab l e d yn a m ic vl a n [ V LA N ID ] P a r a me t e rs [ V L A NI D ] v l a n r a ng e ( 1 ~3 0 0 0) C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac - a dd r es s -t a b le uc a st s ta t ic us e r E X EC c o m m an d to di s pl a y d y na m ic u ca s t M AC a dd r es s t a b le en t ri e s o n l y . E x a m pl e A S U S # s h ow ma c -a d d re s s- t ab l e d y na m ic v la n 1 1 0 . 1 9  c l e a r m a c - a d d r e s s - ta b l e  m a c  M A C_ A D D R S y n t ax c l e a r m a c- a dd r es s - ta b le ma c MA C _A D DR P a r a me t e rs a d d r es s m ac a dd r e ss M A C _ AD D R - > M AC a d dr e s s x xx x .x x x x. x xx x ( u n ic a st ) t o a d d to t he ad d re s s t a bl e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e wr i te co n  gu r at i on c om m an d o n th e s w it c h s t ac k o r s t a n da l o ne sw i tc h to cl e ar d yn a mi c L 2 MA C a d dr e s se s i n t h e d a t a ba s e . E x a m pl e A S U S (c o n g ) # c le a r m a c- a dd r e ss - ta b le m ac 00 0 0. 0 0 00 . 00 0 1 1 0 . 2 0 c l e a r m a c - a d d r e s s- t a b l e d y na m i c
GigaX2024B/M L2 Managed Switch CLI Manual 41 S y n t ax c l e a r m a c- a dd r es s - ta b le dy n a mi c P a r a me t e rs C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e wr i te co n  gu r at i on c om m an d o n th e s w it c h s t ac k o r s t a n da l o ne sw i tc h to cl e ar d yn a mi c L 2 MA C a d dr e s se s i n t h e d a t a ba s e . E x a m pl e A S U S (c o n g ) # c le a r m a c- a dd r e ss - ta b le d yn a mi c 1 0 . 2 1  cle ar m ac -a dd re ss- ta bl e dy na mi c in te rf ac e  I F N A M E S y n t ax c l e a r m a c- a dd r es s - ta b le dy n a mi c i n te r f ac e I F NA M E P a r a me t e rs [ I F N AM E ] I n te r fa c e ’s na m e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e wr i te co n  gu r at i on c om m an d o n th e s w it c h s t ac k o r s t a n da l o ne sw i tc h to cl e ar d yn a mi c L 2 MA C a d dr e s se s i n t h e d a t a ba s e . E x a m pl e A S U S (c o n g ) # c le a r m a c- a dd r e ss - ta b le d yn a mi c i n t er f ac e f a 1 / 0/ 1 1 0 . 2 2 c l e a r m a c - a d d r e s s - t a b l e d y n a m i c v l a n V L A N I D S y n t ax c l e a r m a c- a dd r es s - ta b le dy n a mi c v l an V LA N ID P a r a me t e rs [ V L A NI D ] v l an ra n g e ( 1~ 3 00 0 ) C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r
GigaX2024B/M L2 Managed Switch CLI Manual 42 S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e wr i te co n  gu r at i on c om m an d o n th e s w it c h s t ac k o r s t a n da l o ne sw i tc h to cl e ar d yn a mi c L 2 MA C a d dr e s se s i n t h e d a t a ba s e . E x a m pl e A S U S (c o n g ) # c le a r m a c- a dd r e ss - ta b le d yn a mi c v l a n 1 1 0 . 2 3  c l e a r m a c - a d d r e s s - ta b l e  i n t e r f ac e  I F N A M E S y n t ax c l e a r m a c- a dd r es s - ta b le in t e rf a ce IF N A ME P a r a me t e rs [ I F N AM E ] I n t e rf a ce ’ s n a me C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e wr i te co n  gu r at i on c om m an d o n th e s w it c h s t ac k o r s t a n da l o ne sw i tc h to cl e ar s ta t ic L2 M AC ad d re s s es in th e d a t a ba s e . E x a m pl e A S U S (c o n g ) # c le a r m a c- a dd r e ss - ta b le i nt e rf a ce f a1 / 0/ 1 1 0 . 2 4 c l e a r m a c - a d dr e s s - t a b l e m u l t i c a s t M AC A D D R V L A N I D S y n t ax c l e a r m a c- a dd r es s - ta b le mu l t ic a st MA C A DD R V L AN I D P a r a me t e rs [ V L A NI D ] v l a n r a ng e ( 1 ~3 0 0 0) C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e wr i te co n  gu r at i on c om m an d o n th e s w it c h s t ac k o r s t a n da l o ne sw i tc h to cl e ar m ul t ic a st L 2 M AC ad d r es s es in t he d a t a ba s e . E x a m pl e A S U S (c o n g ) # c le a r m a c- a dd r e ss - ta b le m ul t ic a st
GigaX2024B/M L2 Managed Switch CLI Manual 43 0 1 0 0 .5 e 0 a. 0 a0 a 1 1 0 . 2 5 c l e a r m a c - a d d r e s s- t a b l e v l an V L A N I D S y n t ax c l e a r m a c- a dd r es s - ta b le dy n a mi c v l an V LA N ID P a r a me t e rs [ V L A NI D ] v l a n r a ng e ( 1 ~3 0 0 0) C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e wr i te co n  gu r at i on c om m an d o n th e s w it c h s t ac k o r s t a n da l o ne sw i tc h to cl e ar d yn a mi c L 2 MA C a d dr e s se s i n t h e d a t a ba s e . E x a m pl e A S U S (c o n g ) # c le a r m a c- a dd r e ss - ta b le d yn a mi c v l a n 1 1 0 . S p a n ni n g T r ee Pr o to c o l: 1 0 . 2 6 s h o w s p a n n i n g - t r ee s u m m a r y S y n t ax s h o w s p a nn i ng - tr e e s u mm a ry P a r a me t e rs s p a n ni n g -t r ee th e S T P s u m m ar y D i s p l ay sp a n ni n g t re e in f or m at i o n f or on l y a c t i ve p or t s C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w s p an n in g - tr e e a ct i v e. E x a m pl e A S U S # s h ow sp a nn i n g- t re e s u m ma r y 1 0 . 2 7  s h o w s p a n n i n g - t r ee  i n t e r f a ce  [ I F N A M E ]  S y n t ax s h o w s p a nn i ng - tr e e i n te r fa c e [ I FN A ME ] P a r a me t e rs s p a n ni n g -t r ee th e S T P [ I F N AM E ] i nt er f ac e n a m e e q. Fa 1 / 0/ 1 C o m m an d Mo d e P ri vi le g e d E XE C m o d e
GigaX2024B/M L2 Managed Switch CLI Manual 44 D e f a ul t D e s c ri p t io n T o s h o w s p an n in g - tr e e s um m a ry . E x a m pl e A S U S # s h ow sp a nn i n g- t re e i n t er f ac e f a 1 /0 / 1 1 0 . 2 8 s p a n ni n g - t r e e ( e na b l e | d i s a bl e ) S y n t ax s p a n ni n g -t r ee (e n a bl e |d i sa b l e) P a r a me t e rs d i s a bl e -> d i sa b l es th e S p a nn i ng T r e e a l go r it h m g l o b al l y f o r t he s wi t ch e n a b le - > e n a b le s t h e S p an n in g T r e e a lg o ri t h m g l o b al l y f o r t he s wi t ch C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r s p a n ni n g -t r ee di s a bl e S h o w s h o w s p a nn i ng - tr e e a c ti v e D e f a ul t E n a b le D e s c ri p t io n E n a b le / D is a bl e t h e s p an n in g tr e e E x a m pl e A S U S (c o n g ) # s pa n n in g -t r ee e na b le 1 0 . 2 9 s p a n ni n g - t r e e c o st < 1 - 2 0 0 0 00 0 0 0 > S y n t ax s p a n ni n g -t r ee co s t < 1 -2 0 00 0 0 00 0 > P a r a me t e rs c o s t th e pa t h c os t < 1 - 2 00 0 0 00 0 0> V a l i d ra n ge is f ro m 1 to 2 00 , 00 0 ,0 0 0 C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o s pa n n in g -t r ee c os t S h o w s h o w s p a nn i ng - tr e e p o rt de t a il IF N AM E D e f a ul t 1 9 D e s c ri p t io n U s e th e sp a nn i ng - t re e c o st c on  gu r at i o n c om m an d on th e s w i t ch s ta c k o r s t an d al o ne s wi t ch to s et th e s p a nn i ng - tr e e p a th c o s t . E x a m pl e A S U S (c o n g - if ) #s p a nn i ng - tr e e c o st 12 8 1 0 . 3 0 s p a n ni n g - t r e e e d ge - p o r t
GigaX2024B/M L2 Managed Switch CLI Manual 45 S y n t ax s p a n ni n g -t r ee ed g e -p o rt P a r a me t e rs e d g e -p o r t t h e i n te r fa c e i s a t ta c h ed to a L A N s eg m en t th a t i s a t t h e e nd of a b r id g ed L AN or to a n e nd n o d e C o m m an d Mo d e I nt er fa c e m o de N o / c le a r N o s pa n n in g -t r ee e dg e -p o rt S h o w s h o w s p a nn i ng - tr e e p o rt de t a il IF N AM E D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e t he s pa nn in g- tr ee c os t co n gu ra ti on c om ma nd o n t h e sw it ch s t a c k o r s t an d al o n e s wi t ch t o s et th e sp a nn i ng - t re e i n te r f ac e a t t a ch e d t o a LA N se g me n t t h at is at t he en d . E x a m pl e A S U S (c o n g - if ) # s p an n in g -t r e e e dg e -p o r t 1 0 . 3 1  s p a n ni n g - t r e e  f o rw a r d - t i m e < 4 - 3 0 > S y n t ax s p a n ni n g -t r ee fo r w ar d -t i me < 4- 3 0> P a r a me t e rs f o r w ar d - ti m e t h e br i d ge fo r wa r d d e la y t i m e ( se c ) < 4 - 3 0> V al id r a n ge is 4~ 3 0 s e cs C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r N o s pa n n in g -t r ee f or w ar d -t i m e S h o w s h o w s p a nn i ng - tr e e p o rt de t a il IF N AM E D e f a ul t 1 5 s ec D e s c ri p t io n U s e th e sp a nn i ng - t re e c o st c on  gu r at i o n c om m an d on th e s w i t ch s ta c k o r s t an d al o ne s wi t ch to s et th e s p a nn i ng - tr e e b r id g e f o r w ar d de l ay ti m e ( s ec ) . E x a m pl e A S U S (c o n g ) # s pa n n in g -t r ee f or w ar d -t i m e 1 5 1 0 . 3 2 s p a n ni n g - t r e e h e ll o t i m e < 1- 1 0 > S y n t ax s p a n ni n g -t r ee he l l o t im e < 1 - 10 > P a r a me t e rs h e l l o h el lo B P DU s t i m e t h e in t er v a l ( se c ) b e tw e en he l l o B PD U s < 1 - 1 0> v a l i d r a ng e i s 1 ~ 1 0 s ec s C o m m an d Mo d e C on g ur e te r mi n al m od e
GigaX2024B/M L2 Managed Switch CLI Manual 46 N o / c le a r N o s pa n n in g -t r ee h el l o t im e S h o w s h o w s p a nn i ng - tr e e p o rt de t a il IF N AM E D e f a ul t 2 s e c D e s c ri p t io n U s e th e sp a nn i ng - t re e c o st c on  gu r at i o n c om m an d on th e s w i t ch s ta c k o r s t an d al o ne s wi t ch to s et th e h e l lo ti m e t o s e nd h e l l o B P DU s . E x a m pl e A S U S (c o n g ) # s pa n n in g -t r ee h el l o t im e 2 1 0 . 3 3 s p a n n i n g - t r e e l i n k - t y p e ( a u t o | p o i n t - t o - p o i n t | s h a r e d ) S y n t ax s p a n ni n g -t r ee li n k -t y pe (a u t o| p oi n t- t o -p o in t |s h a re d ) P a r a me t e rs l i n k -t y p e th e l in k t y p e f or th e Ra p id Sp a n ni n g T r e e a u t o - > au to ma ti c a ll y d e te r m in e s i f t h e i nt e rf a c e i s a t t a ch e d t o a po i n t- t o- p oi n t l i nk or t o s ha r ed m e d i a p o i n t- t o -p o in t - > a c o nn e c ti o n t o e x ac t ly on e ot h er br i d ge s h a r ed - > a c o nn e c ti o n t o t w o o r m or e br i dg e s C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o s pa n n in g -t r ee l in k -t y pe S h o w s h o w s p a nn i ng - tr e e p o rt de t a il IF N AM E D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sp a nn i ng - t re e c o st c on  gu r at i o n c om m an d on th e s w i t ch s ta c k o r s t an d al o ne s wi t ch to s et th e s p a nn i ng - tr e e l i nk t y p e f o r t h e R ap i d S p an n in g T r e e E x a m pl e A S U S (c o n g - if ) # s p an n in g -t r e e l in k -t y p e a ut o 1 0 . 3 4  s p a n ni n g - t r e e  m a x- a g e  < 6 - 4 0 > S y n t ax s p a n ni n g -t r ee ma x - ag e < 6 -4 0 > P a r a me t e rs m a x - ag e t h e i nt e r va l ( s ec ) be t we e n m e ss a ge s t h e s p a n ni n g t r ee re c e iv e s f ro m th e r o ot s wi t ch < 6 - 4 0> V al id r a n ge is 6~ 4 0 s e cs
GigaX2024B/M L2 Managed Switch CLI Manual 47 C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r N o s pa n n in g -t r ee m ax - ag e S h o w s h o w s p a nn i ng - tr e e p o rt de t a il IF N AM E D e f a ul t 2 0 s ec D e s c ri p t io n U s e th e sp a nn i ng - t re e m a x- a g e c on  gu r a ti o n c om m a nd on t h e sw i t ch st a ck o r s ta n da l o ne sw i tc h to se t t h e s p an n in g - tr e e i n t e rv a l ( s ec ) b e t we e n m es s a ge s t h e s p an n in g t r e e r ec e iv e . E x a m pl e A S U S (c o n g ) # s pa n n in g -t r ee m ax - ag e 2 0 1 0 . 3 5 s p a n ni n g - t r e e p o rt - p r i o r i t y < 0 - 2 4 0 > S y n t ax s p a n ni n g -t r ee po r t -p r io r it y <0 - 24 0 > P a r a me t e rs p o r t -p r i or i ty th e p o r t p ri o ri t y < 0 - 2 40 > Nu mb e r f ro m 0 t o 2 40 , in in c re m e nt s o f 1 6 C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o s pa n n in g -t r ee p or t -p r io r i ty S h o w s h o w s p a nn i ng - tr e e p o rt de t a il IF N AM E D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sp a nn i ng - t re e p o rt - p ri o ri t y c o n g ur a ti o n c o mm a nd o n t he s wi t ch st a c k o r s ta n d al o ne sw i t ch to se t th e s p an n i ng - tr e e t h e po r t p r io r it y be t we e n 0 an d 2 4 0. E x a m pl e A S U S (c o n g - if ) # s p an n in g -t r e e p or t -p r i or i ty 12 8 1 0 . 3 6 s p a n ni n g - t r e e p r io r i t y < 0 - 61 4 4 0 > S y n t ax s p a n ni n g -t r ee pr i o ri t y < 0- 6 1 44 0 > P a r a me t e rs p r i o ri t y t h e s wi t ch p ri o ri t y < 0 - 6 14 4 0 > v a l i d r a ng e i s 0 t o 6 14 4 0 i n i n cr e me n t s o f 4 0 9 6 C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r N o s pa n n in g -t r ee p ri o ri t y S h o w s h o w s p a nn i ng - tr e e p o rt de t a il IF N AM E D e f a ul t 3 2 7 6 8
GigaX2024B/M L2 Managed Switch CLI Manual 48 D e s c ri p t io n U s e th e sp a nn i ng - t re e p r io r i ty co n g u r at i on co m m an d o n t he s wi t ch st a c k o r s ta n d al o ne sw i t ch to se t th e s p an n i ng - tr e e s w i t ch p ri o ri t y E x a m pl e A S U S (c o n g ) # s pa n n in g -t r ee p ri o ri t y 3 2 76 8 1 0 . 3 7 s p a n ni n g - t r e e t r an s m i s s i o n -l i m i t < 1 - 1 0 > S y n t ax s p a n ni n g -t r ee tr a n sm i ss i on - l im i t < 1- 1 0 > P a r a me t e rs t r a n sm i s si o n- l im i t th e t ra n sm i s si o n o f c o ns e cu t iv e RS T P B P D U s < 1 - 1 0> t h e mi n i mu m i n te r v al be t we e n t h e t r a n sm i s si o n o f c o ns e cu t iv e RS T P B P D Us , v a l id r an g e i s 1 ~ 10 C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s pa n n in g -t r ee t ra n sm i ss i o n- l im i t S h o w s h o w s p a nn i ng - tr e e a c ti v e / sh o w r un n i ng - co n g D e f a ul t 3 D e s c ri p t io n U s e th e sp a nn i ng - t re e t r an s m is s io n -l i m it co n g u r at i on co m m an d o n t he s wi t ch st a c k o r s ta n d al o ne sw i t ch to se t th e s p an n i ng - tr e e t r a n sm i s si o n o f c o ns e cu t iv e RS T P B P D Us E x a m pl e A S U S (c o n g ) # s pa n n in g -t r ee t ra n sm i ss i o n- l im i t 3 1 0 . 3 8 s p a n ni n g - t r e e m o de ( p v s t | r ap i d - p v s t ) S y n t ax s p a n ni n g -t r ee mo d e ( p vs t |r a p id - pv s t) P a r a me t e rs P v s t st p m o d e R a p i d- p v st r a pi d st p m o de C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w s h o w s p a nn i ng - tr e e a c ti v e D e f a ul t E n a b le D e s c ri p t io n t h e sp a n ni n g t re e mo d e
GigaX2024B/M L2 Managed Switch CLI Manual 49 E x a m pl e A S U S (c o n g ) # s pa n n in g -t r ee m od e p v st 1 0 . 3 9  s p a n ni n g - t r e e  u p li n k - f a s t S y n t ax s p a n ni n g -t r ee up l i nk - fa s t P a r a me t e rs C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r N o s pa n n in g -t r ee u pl i nk - fa s t S h o w s h o w s p a nn i ng - tr e e s u mm a ry D e f a ul t d i s a bl e D e s c ri p t io n A c c e le r a te th e r o o t p or t t r a ns i ti o ns t o t he fo r w ar d in g s t a te E x a m pl e A S U S (c o n g ) # s pa n n in g -t r ee u pl i nk - fa s t 1 0 . 4 0 s p a nn i n g - t re e a l g o r i t hm - t i m e r < 4- 3 0> < 6 - 4 0 > < 1 - 1 0 > S y n t ax s p a n ni n g -t r ee al g o ri t hm - ti m e r < 4- 3 0> < 6- 4 0> <1 - 1 0> P a r a me t e rs f o r w ar d - ti m e S e t th e fo r wa r d d e la y f o r t h e s pa n ni n g t r ee h e l l o S et t he he l lo in t e rv a l f or t he sp a nn i n g t re e m a x - ag e S e t t he m ax ag e i n t er v al fo r th e s p an n i ng t r e e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r N o s pa n n in g -t r ee a lg o ri t hm - t im e r S h o w s h o w s p a nn i ng - tr e e a c ti v e D e f a ul t D e s c ri p t io n T h i s c o m ma n d s et s sp a nn i ng - t re e p a ra m e te r t o d e f au l t E x a m pl e A S U S (c o n g ) # s pa n n in g -t r ee a lg o ri t hm - t im e 1 0 2 6 1 0 . 4 1 s p a n ni n g - t r e e b p du - g u a r d ( en a b l e | d i s a b le ) S y n t ax s p a n ni n g -t r ee bp d u -g u ar d ( e n ab l e| d is a b le ) P a r a me t e rs E n a b le
GigaX2024B/M L2 Managed Switch CLI Manual 50 D i s a bl e C o m m an d Mo d e I nt er fa c e m o de N o / c le a r S h o w s h o w s p a nn i ng - tr e e p o rt de t a il IF N AM E D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n I f t he s wi t ch re c i ev e t h e b p du se n d b y s e lf , t h e s w it c h p o rt wi l l b e b l o c ke d . E x a m pl e A S U S (c o n g - if ) # s p an n in g -t r e e b pd u -g u a rd en a bl e 1 0 . 4 2  s p a n ni n g - t r e e  m s t m a x - h o p s [ 1 - 4 0 ] S y n t ax s p a n ni n g -t r ee ms t ma x -h o ps [ 1- 4 0] P a r a me t e rs C o m m an d Mo d e c on g ur a t io n t e rm i n al mo d e N o / c le a r n o s pa n n in g -t r ee m st ma x -h o p s S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n 設 設 M S TP B PD U ma x p a ss e d h o p c ou n t (d e fa u lt : 2 0h o ps ) E x a m pl e s A S U S (c o n g ) # s pa n n in g -t r ee m st ma x -h o p s 2 0 1 0 . 4 3  n o  s pa n n i n g - t r e e m s t  m a x - h op s S y n t ax n o s pa n n in g -t r ee m st ma x -h o p s P a r a me t e rs C o m m an d Mo d e c on g ur a t io n t e rm i n al mo d e s h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n 設 設 M S TP B PD U ma x p a ss e d h o p c ou n t 設設 , 設設 設 設 E x a m pl e s A S U S (c o n g ) # n o s p an n in g -t r e e m st ma x - ho p s 1 0 . 4 4 s h o w s p a n n i n g - t r ee m s t
GigaX2024B/M L2 Managed Switch CLI Manual 51 S y n t ax s h o w s p a nn i ng - tr e e m s t P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n 設 設 設 設 MS T P 設設 設 Co n  gu r at i on 設 I ns t an c e 設設 設 設 E x a m pl e s A S U S # s h ow sp a nn i n g- t re e m s t 1 0 . 4 5  s h o w s p a n n i n g - t r ee  m s t  c o n g u r a t i o n S y n t ax s h o w s p a nn i ng - tr e e m s t c on  g ur a ti o n P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n 設 設 設 設 MS T P 設設 設 Co n  gu r at i on 設 設 (R e gi o n N a me / Re v i si o n/ V ID M a p p in g ) E x a m pl e s A S U S # s h ow sp a nn i n g- t re e m s t c o n g ur a t io n 1 0 . 4 6 s h o w s p a n n i n g - t r ee m s t < 1 - 15 > S y n t ax s h o w s p a nn i ng - tr e e m s t < 1- 1 5 > P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n 設 設 設 設 MS T P 設設 設 In s t an c e設 C on  g ur a ti o n設 設 E x a m pl e s A S U S # s h ow sp a nn i n g- t re e m s t 1 1 0 . 4 7 s h o w s p a n n i n g - t r e e m s t i n s t a n c e [ 1 - 1 5 ] i n t e r f a c e  [ I F  Na m e ] S y n t ax s h o w s p a nn i ng - tr e e m s t i ns t a nc e [ 1 -1 5 ] i n te r fa c e [ I F N am e ] P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e
GigaX2024B/M L2 Managed Switch CLI Manual 52 D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n 設 設 設 設 MS T P 設設 設 In s t an c e設 t ar g e t P or t 設C o n g u ra t io n 設 設 E x a m pl e s A S U S # s h ow sp a nn i n g- t re e m s t i n st a nc e 1 i nt e rf a c e f a1 / 0/ 1 1 0 . 4 8 s p a n ni n g - t r e e m o de m s t S y n t ax s p a n ni n g -t r ee mo d e m s t P a r a me t e rs C o m m an d Mo d e c on g ur a t io n t e rm i n al mo d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n 設 設 s p an n i ng tr e e設 設 設 設設 M S TP E x a m pl e s A S U S (c o n g ) # s pa n n in g -t r ee m od e m s t 1 0 . 4 9 s p a n ni n g - t r e e m s t r e v i s i o n < 0 - 6 5 5 3 5 > S y n t ax S p a n ni n g -t r r m st r ev i si o n < 0 -6 5 53 5 > P a r a me t e rs C o m m an d Mo d e C on g ur e te r mi n al m od e S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n 設 設 設 設 M ST P R e g i on 設 設設 設 設 設設 設 設 R e s u lt A S U S (c o n g ) # s pa n n in g -t r ee m st re v is i o n 1 1 0 . 5 0 n o s pa n n i n g - t r e e m s t n a m e S y n t ax n o s pa n n in g -t r ee n am e P a r a me t e rs C o m m an d Mo d e C on g ur e te r mi n al m od e S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n 設 設 設 設 MS T P R e g io n 設 設設 設 設設 設 , 設設 設 設設 設 R e s u lt A S U S (c o n g ) # n o s p an n in g -t r e e n am e
GigaX2024B/M L2 Managed Switch CLI Manual 53 1 0 . 5 1 s p a n ni n g - t r e e m s t n a m e [ N A ME ] S y n t ax S p a n ni n g -t r ee ms t na m e [ NA M E ] P a r a me t e rs C o m m an d Mo d e C on g ur e te r mi n al m od e S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n 設 設 設 設 M ST P R e g i on 設 設設 設 設 設設 R e s u lt A S U S (c o n g ) # s pa n n in g -t r ee m st na m e a b cd 1 0 . 5 2 n o s pa n n i n g - t r e e m s t i n s t a nc e [ m s t i ] S y n t ax n o s pa n n in g -t r ee m st in s ta n c e [ ms t i] P a r a me t e rs C o m m an d Mo d e C on g ur e te r mi n al m od e S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n 設 設 設 設 設設 m s t i ns t a nc e 設設 設 V LA N (V L AN I D) 設 設, 設 設 設設 設 設 R e s u lt A S U S (c o n g ) # n o s p an n in g -t r e e m st in s t an c e 2 1 0 . 5 3 s p a n ni n g - t r e e m s t i n s t a n c e [ m s t i ] v l a n [ v i d s ] S y n t ax S p a n ni n g -t r ee ms t in s ta n ce [ ms t i] vl a n [ v id s ] P a r a me t e rs C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o i ns t a nc e [ m st i ] S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n 設 設 設 設 設設 設 V LA N (V L A N I D) 設 設設 設 設 ms t i n s ta n ce R e s u lt A S U S (c o n g ) # s pa n n in g -t r ee m st in s ta n c e 2 v l an 3 -1 0 0 1 0 . 5 4 s p an n i n g - t r e e ms t [ m s t i s ] c o s t [ v a l u e]
GigaX2024B/M L2 Managed Switch CLI Manual 54 S y n t ax s p a n ni n g -t r ee ms t [m s ti s ] c o st [v a lu e ] P a r a me t e rs m s t i s In st a nc e of MS T 1 - 1 5 V al ue 1 - 2 00 0 00 0 00 C o m m an d Mo d e I nt er fa c e M o de N o / c le a r n o s pa n n in g -t r ee m st [m s ti s ] c o st S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n S e t u p p a th co s t f o r a s p ec i  c p or t E x a m pl e s A S U S (c o n g ) #i n te r f ca e f a 1/ 0 / 1 A S U S (c o n g - if ) #s p a nn i ng - tr e e m s t 1 c o s t 2 00 0 1 0 . 5 5 s p a n n i n g - t r e e m s t [ m s t i s ] p o r t - p r i o r i t y [ v a l u e ] S y n t ax s p a n ni n g -t r ee ms t [m s ti s ] p o rt - pr i or i t y [ va l ue ] P a r a me t e rs m s t i s In st a nc e of MS T 1 - 1 5 p o r t -p r i or i ty 0- 2 40 C o m m an d Mo d e I nt er fa c e M o de N o / c le a r n o s pa n n in g -t r ee m st [m s ti s ] p o rt - pr i o ri t y S h o w D e f a ul t 1 2 8 D e s c ri p t io n S e t u p p r io r it y f o r a sp e ci  c p o rt Po r t P r io r it y E x a m pl e s A S U S (c o n g ) #i n te r f ca e f a 1/ 0 / 1 A S U S (c o n g - if ) #s p a nn i ng - tr e e m s t 1 p o r t- p ri o ri t y 1 6 1 1. SNMP
GigaX2024B/M L2 Managed Switch CLI Manual 55 1 1 . 1 s h o w r m o n s t a t is t i c s [ I F NA M E ] S y n t ax s h o w r m o n s ta t is t i cs [I F NA M E ] P a r a me t e rs r m o n R e mo t e m on i t or i ng s t a t is t i cs t he c on t en t s o f t h e s w it c h’ s R M O N s t a t is t i cs ta b l e [ I F N AM E ] I nt er f ac e ’s n am e , e x: f a1 / 0/ 1 o r g i g a bi t e th e rn e t1 / 0 /2 6 C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w r m on st a t is t ic s I F N AM E s t at u s . E x a m pl e s A S U S # s h ow rm o n s t at i st i cs [ fa 1 /0 / 1] 1 1 . 2 s h o w r m o n s t a t is t i c s s t a ck < 1 - 8 > S y n t ax s h o w r m o n s ta t is t i cs st a ck < 1- 8 > P a r a me t e rs r m o n R e mo t e m on i t or i ng s t a t is t i cs t he c on t en t s o f t h e s w it c h’ s R M O N s t a t is t i cs ta b l e < 1 - 8 > st ac k id C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w r m on st a t is t ic s w i t h s pe c i c st a ck id . E x a m pl e s A S U S # s h ow rm o n s t at i st i cs s ta c k 1 1 1 . 3 s h o w s n m p - s e r v er c o m m u n i ty S y n t ax s h o w s n m p- s er v er c om m un i ty P a r a me t e rs s n m p -s e r ve r th e S N MP s er ve r c o m m un i t y SN M P s e r ve r c o m mu n it y C o m m an d Mo d e P r i v il e g ed EX E C m o de D e f a ul t D e s c ri p t io n T o s h o w s n mp - se r v er co m mu n i ty .
GigaX2024B/M L2 Managed Switch CLI Manual 56 E x a m pl e s A S U S # s h ow sn m p- s e rv e r c om m u ni t y 1 1 . 4 s h o w s n m p - s e r v er c o m m u n i ty n e t w o r k S y n t ax s h o w s n m p- s er v er c om m un i ty n et w or k P a r a me t e rs s n m p -s e r ve r th e S N MP s er ve r c o m m un i t y S N MP s er ve r c om m un i t y n e t w or k t h e n et w or k bi n d t o t h is co m mu n i ty C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w s n mp - se r v er co m mu n i ty ne t wo r k . E x a m pl e s A S U S # s h ow sn m p- s e rv e r c om m u ni t y n et w o rk 1 1 . 5 s h o w s n m p - s e r v er c o n t a c t S y n t ax s h o w s n m p- s er v er c on t ac t P a r a me t e rs s n m p -s e r ve r th e S N MP s er ve r c o n t ac t s ho w t h e s y st e m c o nt a ct st r i ng C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w s n mp - se r v er co n ta c t . E x a m pl e s A S U S # s h ow sn m p- s e rv e r c on t a ct 1 1 . 6 s h o w s n m p - s e r v er h o s t S y n t ax s h o w s n m p- s er v er h os t P a r a me t e rs s n m p -s e r ve r th e S N MP s er ve r h o s t t h e r ec i pi e n t ( ho s t) o f a S N MP n ot i ca t io n o p e r at i o n C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w s n mp - se r v er ho s t.
GigaX2024B/M L2 Managed Switch CLI Manual 57 E x a m pl e s A S U S # s h ow sn m p- s e rv e r h os t 1 1 . 7 s h o w s n m p - s e r v er l o c a t i o n S y n t ax s h o w s n m p- s er v er l oc a ti o n P a r a me t e rs s n m p -s e r ve r th e S N MP s er ve r l o c a ti o n s ho w th e s y st e m l o ca t io n st r in g C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w s n mp - se r v er lo c at i o n. E x a m pl e s A S U S # s h ow sn m p- s e rv e r l oc a t io n 1 1 . 8 s h o w s n m p - s e r v er t r a p c o mm u n i t y S y n t ax s h o w s n m p- s er v er t ra p c o mm u n it y P a r a me t e rs s n m p -s e r ve r th e S N MP s er ve r c o m m un i t y S N M P s e r v e r c om m un i t y C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w s n mp - se r v er tr a p c o mm u ni t y . E x a m pl e s A S U S # s h ow sn m p- s e rv e r t ra p co m mu n it y 1 1 . 9  s n m p - s e r v e r  c o m m un i t y  t r a p W O R D S y n t ax s n m p -s e r ve r c o mm u n it y t r ap W OR D P a r a me t e rs c o m m un i t y S N M P s e r v e r c om m un i t y t r a p fo r tr a p u s e W O R D a un i qu e S N M P c o mm u n it y s t ri n g ( m ax 30 c h a r ac t e rs ) t h at a ct s l i ke a p a ss wo r d a n d p e r m it s ac c es s t o th e S N M P pr ot oc o l C o m m an d Mo d e C o n  gu r e t e rm i na l mo d e N o / c le a r
GigaX2024B/M L2 Managed Switch CLI Manual 58 S h o w s h o w s n m p- s er v er t ra p c o mm u n it y / sh o w r u nn i ng - c on  g D e f a ul t P u b l ic D e s c ri p t io n T h i s c o m ma n d s et s th e t r ap c om m un i ty s tr i ng fo r SN M P p r o t oc o l . E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r c o m mu n it y t r a p p ub l ic 1 1 . 1 0  s n m p - s e r v e r  c o m m u n i t y  W O R D  ( r o / r w )  n e t w o r k  A . B . C . D / M A S K S y n t ax s n m p -s e r ve r c o mm u n it y W O RD ( ro / rw ) n e t wo r k A . B . C .D / M AS K P a r a me t e rs c o m m un i t y S N M P s e r v e r c om m un i t y W O R D c r ea t e a n e w c o mm u ni t y s t ri n g ( m ax 30 c h a r ac t e rs ) r o a u ni q ue SN M P c o m mu n it y st r in g t h a t a ct s l i k e a p as s wo r d a n d p er m it s ac c es s t o th e S N M P p r o t oc o l r w t h e re l at i o ns h ip be t w ee n t h e S N MP m a n a ge r an d t h e a g en t ,r o -> r e ad - on l y , rw - > r e a d- w r it e n e t w or k t h e ne t w or k t h at a ll o we d t o ac c es s t h i s c o m m un i t y A . B . C. D / MA S K n et wo rk an d m a sk C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r c o m mu n it y W O R D ( ro | rw ) ne t wo r k A . B . C . D/ M A S K S h o w s h o w s n m p- s er v er c om m un i ty / s h ow ru n n in g -c o n g D e f a ul t P u b l ic , an d t h e n e tw o rk is 0 .0 . 0. 0 /0 . 0 .0 . 0 D e s c ri p t io n T h i s c o m ma n d c re a t e a n e w c o mm u ni t y s t ri n g ( ma x 30 c h a r ac t e rs ) . E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r c o m mu n it y p u b li c r o n e t wo r k 1 9 2 . 19 2 . 1. 1 /2 4 1 1 . 1 1  s n m p - s e r v e r  c on t a c t  D W O R D
GigaX2024B/M L2 Managed Switch CLI Manual 59 S y n t ax s n m p -s e r ve r c o nt a c t D WO R D P a r a me t e rs c o n t ac t th e sy s te m co n ta c t s t ri n g D W O R D st r i ng th a t d e sc r ib e s t h e s ys t em c on t ac t i n f o rm a t io n C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r c o n ta c t S h o w s h o w s n m p- s er v er c on t ac t D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n T h i s c o m ma n d s et s th e S N MP C on ta ct in f or m a ti o n E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r c o n ta c t a su s @ as u s. c om . t w 1 1 . 1 2 s n m p - s e r v er h o s t A . B . C . D S y n t ax s n m p -s e r ve r h o st A . B . C .D P a r a me t e rs h o s t t h e r ec i pi e n t ( ho s t) o f a S N MP n ot i ca t io n o p e r at i o n A . B . C. D IP a dd re ss C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r h o s t A . B . C .D S h o w s h o w s n m p- s er v er h os t / sh o w r u nn i ng - c on  g D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n T h i s c o m ma n d s et s th e S N MP C on ta ct in f or m a ti o n E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r h o s t 1 92 . 19 2 . 1. 1 1 1 . 1 3  s n m p - s e r v e r  l o c a ti o n  D W O R D S y n t ax s n m p -s e r ve r l o ca t i on DW O RD P a r a me t e rs l o c a ti o n th e s y s te m l o ca t i on st r in g D W O R D s tr i ng th a t d e sc r ib e s t h e s ys t e m l oc a ti o n i n fo r ma t i on C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r no sn m p- s er v e r l oc a ti o n S h o w s h o w s n m p- s er v er l oc a ti o n
GigaX2024B/M L2 Managed Switch CLI Manual 60 D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n T h i s c o m ma n d s et s th e S N MP l oc at io n s t ri n g . E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r l o c at i on A S U S 1 1 . 1 4  s n m p - s e r v e r  u s e r W O R D  W O R D  v 3 n o a u t h S y n t ax s n m p -s e r ve r u s er W OR D W O RD v 3 n oa u th P a r a me t e rs W O R D N a m e o f t he us e r W O R D Gr ou p t o w h ic h th e u s er b el o ng s v 3 Us e r u s in g t h e v 3 s e cu r it y mo d el n o a u th Sp ec i  es no au t h en t ic a ti o n o f a pa c k et C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r u s e r W OR D W O R D v 3 S h o w s h o w s n m p- s er v er u se r D e f a ul t N o n e D e s c ri p t io n D e  n e a us e r w ho c an ac c es s th e S N MP e ng in e E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r u s e r t es t g 1 v3 no a ut h 1 1 . 1 5  s n m p - s e r v e r  u s e r  W O R D  W O R D  v 3  a u t h  ( m d 5 | s h a )  W O R D S y n t ax s n m p -s e r ve r u s er W OR D W O RD v 3 a ut h ( m d 5| s ha ) W O R D P a r a me t e rs W O R D N a m e o f t he us e r W O R D Gr ou p t o w h ic h th e u s er b el o ng s v 3 Us e r u s in g t h e v 3 s e cu r it y mo d el a u t h S p e c i e s a u th e nt i c at i on of a p a ck e t w i th o ut e n c r yp t i ng it (m d 5 |s h a) m d 5 U s e HM A C M D 5 a lg o r it h m f or a u t h en t i ca t io n s h a Us e HM A C S H A a lg o r it h m fo r au t h en t i c at i o n W O R D Au th e nt i ca t io n pa s wo r d f o r u se r C o m m an d Mo d e C on g ur e te r mi n al m od e
GigaX2024B/M L2 Managed Switch CLI Manual 61 N o / c le a r n o s nm p - se r ve r u s e r W OR D W O R D v 3 S h o w s h o w s n m p- s er v er u se r D e f a ul t N o n e D e s c ri p t io n D e  n e a us e r w ho c an ac c es s th e S N MP e ng in e E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r u s e r t es t g 1 v3 au t h s h a 1 23 4 56 7 8 1 1 . 1 6  s n m p - s e r v e r  u s e r  W O R D  W O R D  v 3  p r i v  ( m d 5 | s h a )  W O R D d e s  W O R D S y n t ax s n m p -s e r ve r u s er W OR D W O RD v 3 p ri v ( m d 5| s ha ) W O R D d es W O R D P a r a me t e rs W O R D N a m e o f t he us e r W O R D Gr ou p t o w h ic h th e u s er b el o ng s v 3 Us e r u s in g t h e v 3 s e cu r it y mo d el p r i v S p e c i e s a u th e nt i c at i on of a p a ck e t w i th e n c r yp t i on (m d 5| s h a) m d 5 U s e HM A C M D 5 a lg o r it h m f or a u t h en t i ca t io n s h a Us e HM A C S H A a lg o r it h m fo r au t h en t i c at i o n W O R D Au th e nt i ca t io n pa s wo r d f o r u se r d e s Us e D ES al g or i t hm fo r e n c ry p ti o n W O R D En cr y pt i on pa s w or d f o r u s er C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r u s e r W OR D W O R D v 3 S h o w s h o w s n m p- s er v er u se r D e f a ul t N o n e D e s c ri p t io n D e  n e a us e r w ho c an ac c es s th e S N MP e ng in e E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r u s e r t es t g 1 v3 pr i v s h a 1 23 4 56 7 8 d e s 12 3 4 56 7 8
GigaX2024B/M L2 Managed Switch CLI Manual 62 1 1 . 1 7  s n m p - s e r v e r  g r o u p W O R D  v 3  W O RD S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 W O RD P a r a me t e rs g r o u p Co n  gu r e a n e w S N MP g ro up , t ha t m a ps S N M P u s e r s t o S N MP u s e r s W O R D Th e n am e o f t h e g r ou p v 3 Us i ng t he SN M Pv 3 fo r s e cu r i ty mo d e W O R D Th e n am e o f t h e u s er wh o ma p pi n g t o t h e g r o u p C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 t es t 1 1 . 1 8  s n m p - s e r v e r  g r o u p W O R D  v 3  n o au t h S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 n o au t h P a r a me t e rs g r o u p Co n  gu r e a n e w S N MP g ro up , t ha t m a ps S N M P u s e r s t o S N MP u s e r s W O R D Th e n am e o f t h e g r ou p v 3 Us in g th e S N M Pv 3 f o r s e cu r it y m o d e n o a u th S p e c i e s no au t he n t ic a ti o n o f a pa c ke t C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s
GigaX2024B/M L2 Managed Switch CLI Manual 63 E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 n oa u th 1 1 . 1 9  sn m p- s er v er  g r ou p  W OR D  v3  n o au t h r e a d  W O R D S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 n o au t h r ea d WO R D P a r a me t e rs g r o u p Co n  gu r e a n e w S N MP g ro up , t ha t m a ps S N M P u s e r s t o S N MP u s e r s W O R D Th e n am e o f t h e g r ou p v 3 Us in g th e S N M Pv 3 f o r s e cu r it y m o d e n o a u th S p e c i e s no au t he n t ic a ti o n o f a pa c ke t r e a d Th e op t io n th a t a ll o w s y ou to s pe c if y a r ea d v i e w ( d e fa u lt sy s V i e w ) W O R D A st ri n g t h at he n am e o f t h e v i ew th a t e n a b le s yo u o n ly t o v ie w t h e c o nt e nt s of th e a g e n t C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 n oa u th re a d r 1 1 1 . 2 0  sn m p- s er v er  g r ou p  W OR D  v3  n o au t h r e a d  W O R D  w r i t e  W O R D S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 n o au t h r ea d WO R D w ri t e W O RD P a r a me t e rs g r o u p Co n  gu r e a n e w S N MP g ro up , t ha t m a ps S N M P u s e r s t o S N MP u s e r s W O R D Th e n am e o f t h e g r ou p v 3 Us in g th e S N M Pv 3 f o r s e cu r it y m o d e n o a u th S p e c i e s no au t he n t ic a ti o n o f a pa c ke t
GigaX2024B/M L2 Managed Switch CLI Manual 64 r e a d Th e op t io n th a t a ll o w s y ou to s pe c if y a r ea d v i e w ( d e fa u lt sy s V i e w ) W O R D A st ri n g t h at he n am e o f t h e v i ew th a t e n a b le s yo u o n ly t o v ie w t h e c o nt e nt s of th e a g e nt w r i t e Th e o pt i on th a t a l lo w s y o u t o s pe c i fy a w ri t e v i e w ( d e fa u lt no n e ) W O R D A st r in g t h a t i s t he n am e o f t h e v i ew th a t e n a b le s yo u t o e n t er an d c o n g u re th e c o n t en t s o f t h e a g en t C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 n oa u th re a d r 1 w r it e w 1 1 1 . 2 1  sn m p- s er v er  g r ou p  W OR D  v3  n o au t h r e a d  W O R D  w r i t e  W O R D n o t i f y  W OR D S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 n o au t h r ea d WO R D w ri t e W O RD n o t i fy W OR D P a r a me t e rs g r o u p Co n  gu r e a n e w S N MP g ro up , t ha t m a ps S N M P u s e r s t o S N MP u s e r s W O R D Th e n am e o f t h e g r ou p v 3 Us in g th e S N M Pv 3 f o r s e cu r it y m o d e n o a u th S p e c i e s no au t he n t ic a ti o n o f a pa c ke t r e a d Th e op t io n th a t a ll o w s y ou to s pe c if y a r ea d v i e w ( d e fa u lt sy s V i e w ) W O R D A st ri n g t h at he n am e o f t h e v i ew th a t e n a b le s yo u o n ly t o v ie w t h e c o nt e nt s of th e a g e n t w r i t e Th e o pt i o n t ha t a l l ow s y o u t o s p ec i fy a w r it e v i e w ( d e fa u lt no n e )
GigaX2024B/M L2 Managed Switch CLI Manual 65 W O R D A st ri n g t h at is t he na m e o f t h e v ie w th a t e n a b le s yo u t o e n t er an d c o n g u re th e c o n t en t s o f t h e a g en t n o t i fy Th e op t i on th a t a l lo w s y ou t o s pe c if y a n o t i fy v ie w ( d ef a u lt no n e) W O R D A st ri n g t h at is t he na m e o f t h e v ie w th a t e n a b le s yo u t o s p e ci f y a n o t if y , i n f or m , o r t r ap C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 n oa u th re a d r 1 w r it e w 1 n ot i f y n 1 1 1 . 2 2  s n m p - s e r v e r  g r o u p W O R D  v 3  a u th S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 a u th P a r a me t e rs g r o u p Co n  gu r e a n e w S N MP g ro up , t ha t m a ps S N M P u s e r s t o S N MP u s e r s W O R D Th e n am e o f t h e g r ou p v 3 Us in g th e S N M Pv 3 f o r s e cu r it y m o d e a u t h Sp ec i e s a ut h e nt i ca t io n of a p ac k e t w it h ou t e n c r yp t i ng it C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 a ut h
GigaX2024B/M L2 Managed Switch CLI Manual 66 1 1 . 2 3  s n m p - s e r v e r  g r o u p  W O R D  v 3  a u t h  r e a d  W O R D S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 n o au t h r ea d WO R D P a r a me t e rs g r o u p C on  gu r e a ne w S N MP g ro up , t ha t m a p s S NM P u s e r s t o S N M P u s e r s W O R D Th e na me of th e gr o up v 3 U si n g t h e S NM P v 3 f or se c u ri t y m od e a u t h S pe c i e s a u th e nt i ca t i on of a p a ck e t w it h o ut en c ry p t in g i t r e a d Th e op t io n th a t a ll o w s y ou to s pe c if y a r ea d v i e w ( d e fa u lt sy s V i e w ) W O R D A st ri n g t h at he n am e o f t h e v i ew th a t e n a b le s yo u o n ly t o v ie w t h e c o nt e nt s of th e a g e nt C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 a ut h r e ad r 1 1 1 . 2 4  s n m p - s e r v e r  g r o u p  W O R D  v 3  a u t h  r e a d  W O R D  w r i t e  W O R D S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 n o au t h r ea d WO R D w ri t e W O RD P a r a me t e rs g r o u p Co n  gu r e a n e w S N MP g ro up , t ha t m a ps S N M P u s e r s t o S N MP u s e r s W O R D Th e n am e o f t h e g r ou p v 3 Us in g th e S N M Pv 3 f o r s e cu r it y m o d e a u t h Sp ec i e s a ut h e nt i ca t io n of a p ac k e t w it h ou t e n c r yp t i ng it r e a d Th e op t io n th a t a ll o w s y ou to s pe c if y a r ea d v i e w ( d e fa u lt sy s V i e w )
GigaX2024B/M L2 Managed Switch CLI Manual 67 W O R D A st ri n g t h at he n am e o f t h e v i ew th a t e n a b le s yo u o n ly t o v ie w t h e c o nt e nt s of th e a g e n t w r i t e Th e o pt i o n t ha t a l l ow s y o u t o s p ec i fy a w r it e v i e w ( d e fa u lt no n e ) W O R D A st ri n g t h at is t he na m e o f t h e v ie w th a t e n a b le s yo u t o e n t er an d c o n g u re th e c o n t en t s o f t h e a g en t C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 a ut h r e ad r 1 w ri t e w 1 1 1 . 2 5  s n m p - s e r v e r  g r o u p  W O R D  v 3  a u t h  r e a d  W O R D  w r i t e  W O R D n o t i f y  W OR D S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 a u th re a d W O RD wr i te W OR D n o t i fy W OR D P a r a me t e rs g r o u p Co n  gu r e a n e w S N MP g ro up , t ha t m a ps S N M P u s e r s t o S N MP u s e r s W O R D Th e n am e o f t h e g r ou p v 3 Us in g th e S N M Pv 3 f o r s e cu r it y m o d e a u t h Sp ec i e s a ut h e nt i ca t io n of a p ac k e t w it h ou t e n c r yp t i ng it r e a d Th e op t io n th a t a ll o w s y ou to s pe c if y a r ea d v i e w ( d e fa u lt sy s V i e w ) W O R D A st ri n g t h at he n am e o f t h e v i ew th a t e n a b le s yo u o n ly t o v ie w t h e c o nt e nt s of th e a g e n t w r i t e Th e o pt i o n t ha t a l l ow s y o u t o s p ec i fy a w r it e v i e w ( d e fa u lt no n e ) W O R D A st ri n g t h at is t he na m e o f t h e v ie w th a t
GigaX2024B/M L2 Managed Switch CLI Manual 68 e n a b le s yo u t o e n t er an d c o n g u re th e c o n t en t s o f t h e a g en t n o t i fy Th e op t i on th a t a l lo w s y ou t o s pe c if y a n o t i fy v ie w ( d ef a u lt no n e) W O R D A st ri n g t h at is t he na m e o f t h e v ie w th a t e n a b le s yo u t o s p e ci f y a n o t if y , i n f or m , o r t r a p C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 a ut h r e ad r 1 w ri t e w 1 n o t i fy n 1 1 1 . 2 6  s n m p - s e r v e r  g r o u p W O R D  v 3  p r iv S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 p r iv P a r a me t e rs g r o u p Co n  gu r e a n e w S N MP g ro up , t ha t m a ps S N M P u s e r s t o S N MP u s e r s W O R D Th e n am e o f t h e g r ou p v 3 Us in g th e S N M Pv 3 f o r s e cu r it y m o d e p r i v S p e c i e s a u th e nt i c at i on of a p a ck e t w i th e n c r yp t i on C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 p ri v
GigaX2024B/M L2 Managed Switch CLI Manual 69 1 1 . 2 7  s n m p - s e r v e r  g r o u p  W O R D  v 3  p r i v  r e a d  W O R D S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 p r iv re a d W O RD P a r a me t e rs g r o u p Co n  gu r e a n e w S N MP g ro up , t ha t m a ps S N M P u s e r s t o S N MP u s e r s W O R D Th e n am e o f t h e g r ou p v 3 Us in g th e S N M Pv 3 f o r s e cu r it y m o d e p r i v S p e c i e s a u th e nt i c at i on of a p a ck e t w i th e n c r yp t i on r e a d Th e op t io n th a t a ll o w s y ou to s pe c if y a r ea d v i e w ( d e fa u lt sy s V i e w ) W O R D A st ri n g t h at he n am e o f t h e v i ew th a t e n a b le s yo u o n ly t o v ie w t h e c o nt e nt s of th e a g e nt C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 p ri v r e ad r 1 1 1 . 2 8  s n m p - s e r v e r  g r o u p  W O R D  v 3  p r i v  r e a d  W O R D  w r i t e  W O R D S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 p r iv re a d W O RD wr i te W OR D P a r a me t e rs g r o u p Co n  gu r e a n e w S N MP g ro up , t ha t m a ps S N M P u s e r s t o S N MP u s e r s W O R D Th e n am e o f t h e g r ou p v 3 Us in g th e S N M Pv 3 f o r s e cu r it y m o d e p r i v S p e c i e s a u th e nt i c at i on of a p a ck e t w i th e n c r yp t i on r e a d Th e op t io n th a t a ll o w s y ou to s pe c if y a r ea d
GigaX2024B/M L2 Managed Switch CLI Manual 70 v i e w ( d e fa u lt sy s V i e w ) W O R D A st ri n g t h at he n am e o f t h e v i ew th a t e n a b le s yo u o n ly t o v ie w t h e c o nt e nt s of th e a g e n t w r i t e Th e o pt i o n t ha t a l l ow s y o u t o s p ec i fy a w r it e v i e w ( d e fa u lt no n e ) W O R D A st ri n g t h at is t he na m e o f t h e v ie w th a t e n a b le s yo u t o e n t er an d c o n g u re th e c o n t en t s o f t h e a g en t C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 p ri v r e ad r 1 w ri t e w 1 1 1 . 2 9  s n m p - s e r v e r  g r o u p  W O R D  v 3  p r i v  r e a d  W O R D  w r i t e  W O R D n o t i f y  W OR D S y n t ax s n m p -s e r ve r g r ou p WO R D v 3 p r iv re a d W O RD wr i te W OR D n o t i fy W OR D P a r a me t e rs g r o u p Co n  gu r e a n e w S N MP g ro up , t ha t m a ps S N M P u s e r s t o S N MP u s e r s W O R D Th e n am e o f t h e g r ou p v 3 Us in g th e S N M Pv 3 f o r s e cu r it y m o d e p r i v S p e c i e s a u th e nt i c at i on of a p a ck e t w i th e n c r yp t i on r e a d Th e op t io n th a t a ll o w s y ou to s pe c if y a r ea d v i e w ( d e fa u lt sy s V i e w ) W O R D A st ri n g t h at he n am e o f t h e v i ew th a t e n a b le s yo u o n ly t o v ie w t h e c o nt e nt s of th e a g e nt w r i t e Th e o pt i o n t ha t a l l ow s y o u t o s p ec i fy a w r it e v i e w ( d e fa u lt no n e )
GigaX2024B/M L2 Managed Switch CLI Manual 71 W O R D A st ri n g t h at is t he na m e o f t h e v ie w th a t e n a b le s yo u t o e n t er an d c o n g u re th e co n te n ts o f t he ag e n t n o t i fy Th e op t i on th a t a l lo w s y ou t o s pe c if y a n o t i fy v ie w ( d ef a u lt no n e) W O R D A st ri n g t h at is t he na m e o f t h e v ie w th a t e n a b le s yo u t o s p e ci f y a n o t if y , i n f or m , o r t r ap C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r g r o up WO R D v 3 ( n oa u th | a ut h |p r iv ) S h o w s h o w s n m p- s er v er g ro u p D e f a ul t N o n e D e s c ri p t io n C o n  gu r e a ne w S N M P g r ou p , t h at ma p s S N MP u se rs t o S N MP u s e r s E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r g r o up g1 v3 p ri v r e ad r 1 w ri t e w 1 n o t i fy n 1 1 1 . 3 0  s n m p - s e r v e r  v i e w  W O R D  W O R D  ( i n c l u d e d | e x c l ud e d ) S y n t ax s n m p -s e r ve r v i ew W OR D W O RD ( in c lu d ed | e xc l ud e d) P a r a me t e rs v i e w Cr ea te a v i ew en t r y W O R D Th e v ie w n a me i s u se d t o re f er e nc e th e r e c o rd W O R D T o i de n ti f y t h e s ub t re e , s p ec i fy a t e xt st r i ng c o n s is t i ng of nu m b er s , s uc h as .1 . 3. 6 . 2. 4 , o r a wo r d ( de f a ul t , . 1) ( i n c lu d e d| e xc l ud e d ) T yp e of vi e w C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r v i e w W OR D S h o w s h o w s n m p- s er v er v ie w D e f a ul t N o n e D e s c ri p t io n C r e a te a v i ew en t r y E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r v i e w v 1 . 1. 3 . 6. 2 .4 in c l ud e
GigaX2024B/M L2 Managed Switch CLI Manual 72 1 1 . 3 1 s h o w s n m p -s e r v e r v i ew S y n t ax s h o w s n m p- s er v er v ie w P a r a me t e rs s n m p -s e r ve r th e S N MP s er ve r v i e w Sh ow t h e v i ew na m e w h ic h i s us e d t o r e f e re n c e t he re c o rd C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n S h o w t h e v i ew na m e w h ic h i s us e d t o r e fe r en c e t h e r ec o rd . E x a m pl e s A S U S # s h ow sn m p- s e rv e r v ie w 1 1 . 3 2 s h o w s n m p -s e r v e r g r ou p S y n t ax s h o w s n m p- s er v er g ro u p P a r a me t e rs s n m p -s e r ve r th e S N MP s er ve r g r o u p Sh o w S N MP v 3 g r ou p s C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n S h o w S N M Pv 3 g r ou p s E x a m pl e s A S U S # s h ow sn m p- s e rv e r g ro u p 1 1 . 3 3 s h o w s n m p -s e r v e r u s er S y n t ax s h o w s n m p- s er v er u se r P a r a me t e rs s n m p -s e r ve r th e S N MP s er ve r u s e r S h o w SN M Pv 3 u s e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n S h o w S N M Pv 3 u s er s E x a m pl e s A S U S # s h ow sn m p- s e rv e r u se r
GigaX2024B/M L2 Managed Switch CLI Manual 73 1 1 . 3 4 s n m p - s e r v e r h o s t A . B . C . D v e r s i o n ( 1 | 2 ) [ C O M M U N I T Y ] S y n t ax s n m p -s e r ve r h o st A . B . C .D ve r si o n ( 1 |2 ) [ C O MM U NI T Y] P a r a me t e rs h o s t t h e r ec i pi e n t ( ho s t) o f a S N MP n ot i ca t io n o p e r at i o n A . B . C. D IP a dd re ss V er si on ( 1| 2 ) s n m p ve r s io n 1 o r v e rs i on 2 C O M M UN I T Y t ra p co m mu n it y na m e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o s nm p - se r ve r h o s t A . B . C .D S h o w s h o w s n m p- s er v er h os t / sh o w r u nn i ng - c on  g D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n T h i s c o m ma n d s et s th e S N MP C on ta ct in f or m a ti o n E x a m pl e s A S U S (c o n g ) # s nm p - se r ve r h o s t 1 92 . 19 2 . 1. 1 1 v e r si o n 1 ab c d 1 1 . 3 5 n o s n m p - s er v e r c o m m un i t y t r a p S y n t ax N o s nm p - se r ve r c o m mu n it y t r a p P a r a me t e rs c o m m un i t y S N M P s e r v e r c om m un i t y t r a p fo r tr a p u s e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w s h o w s n m p- s er v er t ra p c o mm u n it y / sh o w r u nn i ng - c on  g D e f a ul t P u b l ic D e s c ri p t io n T h i s c o m ma n d s et s th e t r ap c om m un i ty s tr i ng fo r SN M P p r o t oc o l . E x a m pl e s A S U S # n o s n mp - se r v er co m mu n i ty tr a p 1 1 . 3 6 s h o w r m o n a l a r m s S y n t ax s h o w r m o n a la r ms
GigaX2024B/M L2 Managed Switch CLI Manual 74 P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n D i s p la y s t h e R MO N al a rm ta b l e E x a m pl e s A S U S # s h ow rm o n a l ar m s 1 1 . 3 7 s h o w r m o n e v e n t s S y n t ax s h o w r m o n a la r ms P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n D i s p la y s t h e R MO N ev e nt ta b l e E x a m pl e s A S U S # s h ow rm o n e v en t s 1 1 . 3 8 s h o w r m o n h i s t o r y S y n t ax s h o w r m o n h is t or y P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n D i s p la y s t h e R MO N hi s to r yt a b le E x a m pl e s A S U S # s h ow rm o n h i st o ry 1 1 . 3 9 r mon alarm <1-65 536> OID <1-4294 9672 95> (a bs o l u t e | d e l ta ) ri si ng - t h r e s h o l d V AL UE <1 -6 55 35 > f a l l i n g - t h r e s h ol d  V A L U E  < 1 - 6 5 5 3 5>  [ O W N E R ] S y n t ax r m o n a l a rm <1 - 65 5 3 6> OI D < 1 - 42 9 49 6 72 9 5 > ( ab s ol u t e| d el t a) r i s i ng - t hr e sh o ld V A L U E <1 - 65 5 35 > fa l li n g- t h re s ho l d V A L U E < 1 - 6 55 3 5 > [ OW N ER ] P a r a me t e rs < 1 - 6 55 3 6 > S p e c if y th e a l ar m nu m be r O I D Th e MI B o b je c t , 1 .3 . 6. 1 . 2. 1 .1 6 .1 . 1 .1 . 5. 1 f o r
GigaX2024B/M L2 Managed Switch CLI Manual 75 e t h e rS t a ts P kt s o f po r t 1 < 1 - 4 29 4 9 67 2 95 > Th e ti m e i nt e r va l o f a l a rm mo n it o r , i n s e c o nd s a b s o lu t e T o te st ea c h M I B v ar i a bl e d i re c t ly d e l t a T o te s t t he c ha n ge be t w ee n s a mp l e s o f a M I B va r i ab l e V AL UE Th e ri si n g t hr e s ho l d v al u e , t he ra n g e i s - 2 1 4 74 8 3 64 8 t o 2 1 4 74 8 36 4 7 < 1 - 6 55 3 5 > S p e c i fy th e RM O N e ve n t t o t r ig g e r w he n r i s i ng t hr e sh o ld e xc e ed s V AL UE Th e fa ll i ng th r e sh o ld va l u e, th e r a n ge is - 2 1 4 74 8 3 64 8 t o 2 1 4 74 8 36 4 7 < 1 - 6 55 3 5 > S p e c if y th e R M ON e ve n t t o t r ig g er wh e n f a l l in g th r es h ol d ex c ee d s [ O W N ER ] Sp ec if y t he o wn e r o f t h is RM O N a l ar m C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o r mo n al a rm <1 - 6 55 3 6> D e f a ul t D e s c ri p t io n T o a d d rm o n a la r m e n tr y E x a m pl e s A S U S (c o n g ) # r mo n al a rm 33 1 .3 . 6. 1 .2 . 1 .1 6 .1 . 1. 1 . 5. 1 1 0 d e l ta r i s i ng - t hr e sh o ld 1 00 0 0 1 0 f a ll i ng - th r e sh o ld 10 0 0 2 0 a s us 1 1 . 4 0 r mon alarm <1-65 536> OID <1-4294 9672 95> (a bs o l u t e | d e l ta ) ri si ng - t h r e s h o l d V AL UE <1 -6 55 35 > f a l l i n g - t h r e s h ol d  V A L U E   [ O W N E R ] S y n t ax r m o n a l a rm <1 - 65 5 3 6> OI D < 1 - 42 9 49 6 72 9 5 > ( ab s ol u t e| d el t a) r i s i ng - t hr e sh o ld V A L U E <1 - 65 5 35 > fa l li n g- t h re s ho l d V A L U E [ O W N ER ] P a r a me t e rs < 1 - 6 55 3 6 > S p e c if y th e a l ar m nu m be r O I D Th e MI B o b je c t , 1 .3 . 6. 1 . 2. 1 .1 6 .1 . 1 .1 . 5. 1 f o r e t h e rS t a ts P kt s o f po r t 1 < 1 - 4 29 4 9 67 2 95 > Th e ti m e i nt e r va l o f a l a rm mo n it o r , i n s e c o nd s
GigaX2024B/M L2 Managed Switch CLI Manual 76 a b s o lu t e T o te st ea c h M I B v ar i a bl e d i re c t ly d e l t a T o te s t t he c ha n ge be t w ee n s a mp l e s o f a M I B va r i ab l e V AL UE Th e ri si n g t hr e s ho l d v al u e , t he ra n g e i s - 2 1 4 74 8 3 64 8 t o 2 1 4 74 8 36 4 7 < 1 - 6 55 3 5 > S p e c i fy th e RM O N e ve n t t o t r ig g e r w he n r i s i ng t hr e sh o ld e xc e ed s V AL UE Th e fa ll i ng th r e sh o ld va l u e, th e r a n ge is - 2 1 4 74 8 3 64 8 t o 2 1 4 74 8 36 4 7 [ O W N ER ] Sp ec if y t he o wn e r o f t h is RM O N a l ar m C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o r mo n al a rm <1 - 6 55 3 6> D e f a ul t D e s c ri p t io n T o a d d rm o n a la r m e n tr y E x a m pl e s A S U S (c o n g ) # r mo n al a rm 33 1 .3 . 6. 1 .2 . 1 .1 6 .1 . 1. 1 . 5. 1 1 0 d e l ta r i s i ng - t hr e sh o ld 1 00 0 0 1 0 f a ll i ng - th r e sh o ld 10 0 0 a s us 1 1 . 4 1 r mon alarm <1-65 536> OID <1-4294 9672 95> ( a b s o l u t e | d e l t a )  r i s i ng - t h r e s h o l d  V A L U E  f a l l i n g - t h r e s h o l d  V A L U E  < 1 - 6 5 5 3 5>  [ O W N E R ] S y n t ax r m o n a l a rm <1 - 65 5 3 6> OI D < 1 - 42 9 49 6 72 9 5 > ( ab s ol u t e| d el t a) r i s i ng - t hr e sh o ld V A L U E f a ll i ng - t hr e sh o ld V A L U E <1 - 65 5 35 > [ O W N ER ] P a r a me t e rs <1 -6 5 53 6 > S p e c i f y t he al a r m n um b er O I D Th e MI B o b je c t , 1 .3 . 6. 1 . 2. 1 .1 6 .1 . 1 .1 . 5. 1 f o r e t h e rS t a ts P kt s o f po r t 1 < 1 - 4 29 4 9 67 2 95 > Th e ti m e i nt e r va l o f a l a rm mo n it o r , i n s e c o nd s a b s o lu t e T o te st ea c h M I B v ar i a bl e d i re c t ly d e l t a T o te s t t he c ha n ge be t w ee n s a mp l e s o f a M I B va r i ab l e V AL UE Th e ri si n g t hr e s ho l d v al u e , t he ra n g e i s - 2 1 4 74 8 3 64 8 t o 2 1 4 74 8 36 4 7
GigaX2024B/M L2 Managed Switch CLI Manual 77 V AL UE Th e fa ll i ng th r e sh o ld va l u e, th e r a n ge is - 2 1 4 74 8 3 64 8 t o 2 1 4 74 8 36 4 7 < 1 - 6 55 3 5 > S p e c if y th e R M ON e ve n t t o t r ig g er wh e n f a l l in g th r es h ol d ex c ee d s [ O W N ER ] Sp ec if y t he o wn e r o f t h is RM O N a l ar m C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o r mo n al a rm <1 - 6 55 3 6> D e f a ul t D e s c ri p t io n T o a d d rm o n a la r m e n tr y E x a m pl e s A S U S (c o n g ) # r mo n al a rm 33 1 .3 . 6. 1 .2 . 1 .1 6 .1 . 1. 1 . 5. 1 1 0 d e l ta r i s i ng - t hr e sh o ld 1 00 0 0 f al l i ng - th r es h o ld 10 0 0 1 0 a s us 1 1 . 4 2 r mon alarm <1-65 536> OID <1-4294 9672 95> ( a b s o l u t e | d e l t a )  r i s i ng - t h r e s h o l d  V A L U E  f a l l i n g - t h r e s h o l d  V A L U E  [ O W N E R ] S y n t ax r m o n a l a rm <1 - 65 5 3 6> OI D < 1 - 42 9 49 6 72 9 5 > ( ab s ol u t e| d el t a) r i s i ng - t hr e sh o ld V A L U E f a ll i ng - t hr e sh o ld V A L U E [O W NE R ] P a r a me t e rs < 1 - 6 55 3 6 > S p e c if y th e a l ar m nu m be r O I D Th e MI B o b je c t , 1 .3 . 6. 1 . 2. 1 .1 6 .1 . 1 .1 . 5. 1 f o r e t h e rS t a ts P kt s o f po r t 1 < 1 - 4 29 4 9 67 2 95 > Th e ti m e i nt e r va l o f a l a rm mo n it o r , i n s e c o nd s a b s o lu t e T o te st ea c h M I B v ar i a bl e d i re c t ly d e l t a T o t e st th e c h a ng e b e tw e e n s am p le s of a M I B va r i ab l e V AL UE Th e ri si n g t hr e s ho l d v al u e , t he ra n g e i s - 2 1 4 74 8 3 64 8 t o 2 1 4 74 8 36 4 7 V AL UE Th e fa ll i ng th r e sh o ld va l u e, th e r a n ge is - 2 1 4 74 8 3 64 8 t o 2 1 4 74 8 36 4 7 [ O W N ER ] Sp ec if y t he o wn e r o f t h is RM O N a l ar m C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o r mo n al a rm <1 - 6 55 3 6>
GigaX2024B/M L2 Managed Switch CLI Manual 78 D e f a ul t D e s c ri p t io n T o a d d rm o n a la r m e n tr y E x a m pl e s A S U S (c o n g ) # r mo n al a rm 33 1 .3 . 6. 1 .2 . 1 .1 6 .1 . 1. 1 . 5. 1 1 0 d e l ta r i s i ng - t hr e sh o ld 1 00 0 0 f al l i ng - th r es h o ld 10 0 0 a s us 1 1 . 4 3 r m o n e v e n t < 1 - 6 5 5 3 6 > d e s c r i p t i o n N A M E [ O W N E R ] S y n t ax r m o n e v e nt <1 - 65 5 3 6> de s cr i p ti o n N AM E [O W NE R ] P a r a me t e rs < 1 - 6 55 3 6 > S p e c if y th e e v en t nu m be r N A M E Th e d es c ri p t io n s t ri n g [ O W N ER ] Sp e ci f y t h e o wn e r o f t h is R MO N e v en t C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o r mo n ev n et <1 - 6 55 3 6> D e f a ul t D e s c ri p t io n T o a d d RM O N e ve n t e n tr y E x a m pl e s A S U S (c o n g ) # r mo n ev e nt 20 d es c ri p ti o n f a ll i ng - t hr e sh o ld a su s 1 1 . 4 4 r m on ev e n t < 1 -6 5 5 3 6 > d es c r i p ti o n N A ME lo g [ O W N E R ] S y n t ax r m o n e v e nt <1 - 65 5 3 6> de s cr i p ti o n N AM E lo g [ O WN E R ] P a r a me t e rs < 1 - 6 55 3 6 > S p e c if y th e e v en t nu m be r N A M E Th e d es c ri p t io n s t ri n g l o g G e ne r at e an RM O N l o g w he n t h e e v en t i s tr i gg e re d [ O W N ER ] S p ec i fy t he ow n er o f t hi s R M O N e ve n t C o m m an d Mo d e C o n  gu r e t e rm i na l mo d e N o / c le a r n o r mo n ev n et <1 - 6 55 3 6> D e f a ul t D e s c ri p t io n T o a d d RM O N e ve n t e n tr y E x a m pl e s A S U S (c o n g ) # r mo n ev e nt 20 d es c ri p ti o n f a ll i ng - t hr e sh o ld l og a s u s
GigaX2024B/M L2 Managed Switch CLI Manual 79 1 1 . 4 5 r m o n e v e n t < 1- 6 5 5 3 6 > d e s c r i p t i o n N A M E tr a p C O M M U N I T Y  [ O W N E R ] S y n t ax r m o n e v e nt <1 - 65 5 3 6> de s cr i p ti o n N AM E tr a p C OM M U NI T Y [ O W N ER ] P a r a me t e rs < 1 - 6 55 3 6 > S p e c if y th e e v en t nu m be r N A M E Th e d es c ri p t io n s t ri n g t r a p Ge n e ra t e a n S N MP t r a p wh e n t he e ve n t i s t r i g ge r e d C O M M UN I T Y Th e SN M P c o m mu n i ty st r in g [ O W N ER ] Sp e ci f y t h e o wn e r o f t h is R MO N e v en t C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o r mo n ev n et <1 - 6 55 3 6> D e f a ul t D e s c ri p t io n T o a d d RM O N e ve n t e n tr y E x a m pl e s A S U S (c o n g ) # r mo n ev e nt 20 d es c ri p ti o n f a ll i ng - t hr e sh o ld t ra p p u b l ic a su s 1 1 . 4 6 r m on ev e n t < 1 -6 5 5 3 6 > d es c r i p ti o n N A ME lo g t r a p  C O M M U N I T Y  [ O W NE R ] S y n t ax r m o n e v e nt <1 - 65 5 3 6> de s cr i p ti o n N AM E tr a p C OM M U NI T Y [ O W N ER ] P a r a me t e rs < 1 - 6 55 3 6 > S p e c if y th e e v en t nu m be r N A M E Th e d es c ri p t io n s t ri n g l o g Ge ne ra t e a n R M ON lo g wh e n t he e ve n t i s t r i g ge r e d t r a p Ge n e ra t e a n S N MP t r a p wh e n t he e ve n t i s t r i g ge r e d C O M M UN I T Y Th e SN M P c o m mu n i ty st r in g [ O W N ER ] Sp e ci f y t h e o wn e r o f t h is R MO N e v en t C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o r mo n ev n et <1 - 6 55 3 6>
GigaX2024B/M L2 Managed Switch CLI Manual 80 D e f a ul t D e s c ri p t io n T o a d d RM O N e ve n t e n tr y E x a m pl e s A S U S (c o n g ) # r mo n ev e nt 20 d es c ri p ti o n f a ll i ng - t hr e sh o ld l og t r a p p u b li c a s us 1 1 . 4 7  r m o n  h i s t o r y  < 1- 6 5 5 3 6 >  I F N A M E [ O W N E R ] S y n t ax r m o n h i s to r y < 1- 6 5 53 6 > I FN A M E [ OW N ER ] P a r a me t e rs < 1 - 6 55 3 6 > S p e c if y th e R M ON g ro u p o f s t at i st i cs I F N A ME In t e rf a ce na m e ( e .g . ; f a st e th e rn e t 1/ 0 /1 ) [ O W N ER ] Sp e ci f y t h e o wn e r o f t h is R MO N h i st o r y g r o u p C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o r mo n hi s to r y < 1 -6 5 53 6 > D e f a ul t D e s c ri p t io n T o a d d RM O N h is t o ry en t ry E x a m pl e s A S U S (c o n g ) # r mo n hi s to r y 2 0 f a 1/ 0 /1 a su s 1 1 . 4 8 r m o n h i s t o r y < 1 - 6 5 5 3 6 > I F N A M E b u c k e t s < 1 - 1 0 0 >  [ O W N E R ] S y n t ax r m o n h i s to r y < 1- 6 5 53 6 > I FN A M E b uc k et s <1 - 10 0 > [ O WN E R] P a r a me t e rs < 1 - 6 55 3 6 > S p e c if y th e R M ON g ro u p o f s t at i st i cs I F N A ME In t e rf a ce na m e ( e .g . ; f a st e th e rn e t 1/ 0 /1 ) b u c k et s Sp ec i fy th e ma x im u m n u mb e r o f b u ck e ts f o r RM O N h i st o ry < 1 - 1 00 > T h e b u c ke t r e qu e s t n um b er , d e f a ul t i s 5 0 [ O W N ER ] S p ec i fy t he ow n er o f t hi s R M O N h is t or y gr o up C o m m an d Mo d e C o n  gu r e t e rm i na l mo d e N o / c le a r n o r mo n hi s to r y < 1 -6 5 53 6 > D e f a ul t D e s c ri p t io n T o a d d RM O N h is t o ry en t ry
GigaX2024B/M L2 Managed Switch CLI Manual 81 E x a m pl e s A S U S (c o n g ) # r mo n hi s to r y 2 0 f a 1/ 0 /1 b uc k et s 3 0 as u s 1 1 . 4 9 r m o n h i s t o r y < 1 - 6 5 5 3 6 > I F N A M E i n t e r v a l < 1 - 4 2 9 4 9 6 7 2 9 5 >  [ O W NE R ] S y n t ax r m o n h i s to r y < 1- 6 5 53 6 > I FN A M E i nt e rv a l < 1 -4 2 94 9 6 72 9 5> [ O W N ER ] P a r a me t e rs < 1 - 6 55 3 6 > S p e c if y th e R M ON g ro u p o f s t at i st i cs I F N A ME In t e rf a ce na m e ( e .g . ; f a st e th e rn e t 1/ 0 /1 ) i n t e rv a l S p e c i f y t he ti m e p e ri o d o f p o ll i ng i nt e rv a l < 1 - 4 29 4 9 67 2 95 > Th e po l li n g i n te r va l , i n s e co n ds [ O W N ER ] Sp e ci f y t h e o wn e r o f t h is R MO N h i st o r y g r o u p C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o r mo n hi s to r y < 1 -6 5 53 6 > D e f a ul t D e s c ri p t io n T o a d d RM O N h is t o ry en t ry E x a m pl e s A S U S (c o n g ) # r mo n hi s to r y 2 0 f a 1/ 0 /1 i nt e rv a l 3 0 a s us 1 1 . 5 0 r m o n h i s t o r y < 1 - 6 5 5 3 6 > I F N A M E b u c k e t s < 1 - 1 0 0 >  i n t e r v a l < 1 - 4 2 9 4 9 6 72 9 5 >  [ O W N E R ] S y n t ax r m o n h i s to r y < 1- 6 5 53 6 > I FN A M E b uc k et s <1 - 10 0 > i n te r va l < 1 - 4 29 4 9 67 2 95 > [ O W NE R ] P a r a me t e rs < 1 - 6 55 3 6 > S p e c if y th e R M ON g ro u p o f s t at i st i cs I F N A ME In t e rf a ce na m e ( e .g . ; f a st e th e rn e t 1/ 0 /1 ) b u c k et s Sp ec i fy th e ma x im u m n u mb e r o f b u ck e ts f o r RM O N h i st o ry < 1 - 1 00 > Th e b uc k et r eq u es t n u m be r , d e fa u lt i s 5 0 i n t e rv a l S p e c i f y t he ti m e p e ri o d o f p o ll i ng i nt e rv a l < 1 - 4 29 4 9 67 2 95 > Th e po l li n g i n te r va l , i n s e co n ds [ O W N ER ] Sp e ci f y t h e o wn e r o f t h is R MO N h i st o r y g r o u p
GigaX2024B/M L2 Managed Switch CLI Manual 82 C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o r mo n hi s to r y < 1 -6 5 53 6 > D e f a ul t D e s c ri p t io n T o a d d RM O N h is t o ry en t ry E x a m pl e s A S U S (c o n g ) # r mo n hi s to r y 2 0 f a 1/ 0 /1 b uc k et s 3 0 in t er v al 3 0 a s u s 12. ACL : MAC Filter 1 2 . 1  m a c  a cc e s s - l i s t  e x t en d e d  W O R D S y n t ax m a c ac c e ss - li s t e x te n de d W O R D P a r a me t e rs A c c e ss - l is t na me d a c ce s s- l i st e x t e nd e d e x t e n de d a c c es s -l i st W O R D a ac c es s -l i st n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o m ac a cc e ss - li s t e x te n de d WO R D S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d d e n e a n e x te n d ed MA C a c c es s l i st u si n g a n a m e , a nd en t er a cc e ss - li s t c o n g ur a t io n m o de . E x a m pl e s A S U S (c o n g ) # m ac a cc e ss - li s t e x te n de d ab c 1 2 . 2 s h o w ma c a c c e s s -g r o u p [ I F N A ME ] S y n t ax s h o w m a c a c ce s s- g r ou p [ I FN A M E] P a r a me t e rs [I FN A ME ] e x : f a1 / 0/ 1 C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac a cc e ss - gr o u p [ IF N AM E ] E X EC co m m an d t o
GigaX2024B/M L2 Managed Switch CLI Manual 83 d i s p la y th e p a ra m e te r s f or a n m ac ac c e ss on th e sw i tc h . E x a m pl e s A S U S # s h ow ma c a c c es s -g r ou p [f a 1/ 0 /1 ] 1 2 . 3 s h o w ma c a c c e s s -l i s t [ A C L N A ME ] S y n t ax s h o w m a c a c ce s s- l i st [A C LN A M E] P a r a me t e rs [ A C L NA M E ] ex : m a c a c ce s s l i st na m e C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w m ac a cc e ss - li s t [ I FN A ME ] EX E C c om m a nd to d i s p la y th e p a ra m e te r s f or a n m ac ac c e ss on th e sw i tc h . E x a m pl e s A S U S # s h ow ma c a c c es s -l i st r d1 0 1 2 . 4 ( p e r mi t | d e n y ) an y a n y [ I F N AM E ] S y n t ax ( p e r mi t | de n y) an y an y [ I FN A M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. a n y an y so u rc e M a c a d dr e ss a n y an y de s ti n at i o n M ac ad d r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o ( pe r m it | de n y) a ny an y [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) # p er m i t a ny an y [f a 1/ 0 /1 ] 1 2 . 5 ( p e r m i t | d e n y ) M A C A D D R M A C A D D R a n y [ I F N A M E ] S y n t ax ( p e r mi t | de n y) MA C A DD R M A CA D D R a ny [I F N AM E ]
GigaX2024B/M L2 Managed Switch CLI Manual 84 P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. M A C A DD R S o u r ce M AC ad d re s s x x xx . xx x x .x x xx M A C A DD R S o u r ce M AC ad d re s s m a sk xx x x .x x xx . xx x x a n y an y de s ti n at i o n M ac ad d r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o ( pe r m it | de n y) M AC A DD R M A C AD D R a ny [ IF N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) # p er m i t 0 00 0 .0 0 0 0. 0 00 1 0 0 0 0. 0 00 0 .0 0 0 0 a ny [ f a 1 /0 / 1 ] 1 2 . 6 ( p e r m it | d e n y ) h os t M A C A D D R an y [ I F N A M E] S y n t ax ( p e r mi t | de n y) ho s t M A CA D DR a ny [I F NA M E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. h o s t A s i n gl e s o ur c e h o st M A C A DD R S o u r ce M AC ad d re s s x x xx . xx x x .x x xx a n y an y de s ti n at i o n M ac ad d r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r ( p e r mi t | de n y) ho s t M A CA D DR a ny [I F NA M E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d .
GigaX2024B/M L2 Managed Switch CLI Manual 85 E x a m pl e s A S U S (c o n g ) # p er m i t h os t 0 0 0 0. 0 00 0 .0 0 0 1 a ny [ f a 1 /0 / 2] 1 2 . 7 ( p e r m i t | d e n y ) h o s t M A C A D D R h o s t M A C A D D R [ I F N A M E ] S y n t ax ( p e r mi t | de n y) ho s t M A CA D DR h os t M A CA D D R [ IF N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. h o s t A s i n gl e s o ur c e h o st M A C A DD R S o u r ce M AC ad d re s s x x xx . xx x x .x x xx h o s t A s i n gl e d e st i n at i on ho s t M A C A DD R D e s t in a t io n M A C a d dr e ss xx x x .x x xx . xx x x [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o ( pe r m it | de n y) h os t M A CA D D R h os t M A C AD D R [ IF N A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) # p er m i t h os t 0 0 0 0. 0 00 0 .0 0 0 1 h os t 0 0 0 0 .0 0 0 0. 0 00 2 [ f a 1/ 0 /2 ] 1 2 . 8 ( p e r m i t | d e n y ) M A C A D D R M A C A D D R M A C A D D R M A C A D D R [ I F N A M E ] S y n t ax ( p e r mi t | de n y) MA C A DD R M A CA D D R M AC A DD R MA C AD D R [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. M A C A DD R S o u r ce M AC ad d re s s x x xx . xx x x .x x xx M A C A DD R S o u r ce M AC ad d re s s m a sk xx x x .x x xx . xx x x M A C A DD R D e s t in a t io n M A C a d dr e ss xx x x .x x xx . xx x x
GigaX2024B/M L2 Managed Switch CLI Manual 86 M A C A DD R D e s t in a t io n M A C a d dr e ss ma s k x x xx . xx x x . x x x x [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o ( pe r m it | de n y) M AC A DD R M A C AD D R M AC A D DR M A C A DD R [I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) # p er m i t 0 00 0 .0 0 0 0. 0 00 1 0 0 0 0. 0 00 0 .0 0 0 0 0 0 0 0 .0 0 0 0. 0 00 2 0 0 0 0. 0 00 0 .0 0 0 0 [ fa 1 /0 / 2 ] 1 2 . 9 ( p e r m i t | d e n y ) h o s t M A C A D D R M A C A D D R M A C A D D R [ I F N A M E] S y n t ax ( p e r mi t | de n y) ho s t M A CA D DR M AC A DD R M A C AD D R [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. h o s t A s i n gl e s o ur c e h o st M A C A DD R S o u r ce M AC ad d re s s x x xx . xx x x .x x xx M A C A DD R D e s t in a t io n M A C a d dr e ss xx x x .x x xx . xx x x M A C A DD R D e s t in a t io n M A C a d dr e ss ma s k x x xx . xx x x . x x x x [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o ( pe r m it | de n y) h os t M A CA D D R M AC A DD R MA C AD D R [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d .
GigaX2024B/M L2 Managed Switch CLI Manual 87 E x a m pl e s A S U S (c o n g ) # p er m i t h os t 0 0 0 0. 0 00 0 .0 0 0 1 0 00 0 .0 0 0 0. 0 00 2 0 0 0 0 .0 0 0 0. 0 00 0 [ f a 1/ 0 /2 ] 1 2 . 1 0 ( p e r m i t | d e n y ) M A C A D D R M A C A D D R h o s t M A C A D D R [ I F N A M E] S y n t ax ( p e r mi t | de n y) MA C A DD R M A CA D D R h os t M A C AD D R [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. M A C A DD R S o u r ce M AC ad d re s s x x xx . xx x x .x x xx M A C A DD R S o u r ce a dd r es s m a s k x xx x .x x x x. x xx x h o s t A s i n gl e d e st i n at i on ho s t M A C A DD R D e s t in a t io n M A C a d dr e ss xx x x .x x xx . xx x x [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o ( pe r m it | de n y) M AC A DD R M A C AD D R h os t MA C AD D R [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) # p er m i t 0 00 0 .0 0 0 0. 0 00 1 0 0 0 0. 0 00 0 .0 0 0 0 h os t 0 0 0 0 .0 0 0 0. 0 00 2 [ f a 1/ 0 /2 ] 1 2 . 1 1 ( p e r m i t | d e n y) a n y h o s t MA C A D D R [ I F N AM E ] S y n t ax ( p e r mi t | de n y) an y ho s t M AC A D DR [I F NA M E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. . a n y an y so u rc e Ma c a d dr e s s . h o s t A s i n gl e d e st i n at i on ho s t . M A C A DD R D e s t in a t io n M A C a d dr e ss xx x x .x x xx . xx x x
GigaX2024B/M L2 Managed Switch CLI Manual 88 [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o ( pe r m it | de n y) a ny ho s t M A CA D DR [I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) # p er m i t a ny ho s t 0 0 00 . 00 0 0 .0 0 02 [f a 1 /0 / 1] 1 2 . 1 2 ( p e r m i t | d e n y ) a n y M A C A D D R M A C A D D R [ I F N A M E ] S y n t ax ( p e r mi t | de n y) an y MA C AD D R M A CA D DR [I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. a n y an y so u rc e M A C a d dr e ss M A C A DD R D e s t in a t io n M A C a d dr e ss xx x x .x x xx . xx x x M A C A DD R D e s t in a t io n M A C a d dr e ss ma s k x x xx . xx x x . x x x x [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o ( pe r m it | de n y) a ny MA C AD D R M A CA D DR [ IF N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) # p er m i t a ny 00 0 0 .0 0 00 . 00 0 1 0 0 00 . 00 0 0 .0 0 00 [ f a 1 /0 / 2 ] 1 2 . 1 3  ma c  a c c e s s - g ro u p  W O R D  in S y n t ax m a c ac c e ss - gr o up W OR D i n
GigaX2024B/M L2 Managed Switch CLI Manual 89 P a r a me t e rs A c c e ss - l is t na me d a c ce s s- l i st e x t e nd e d e x t e n de d a c c es s -l i st W O R D ac ce s s- l is t n a m e C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o m ac a cc e ss - gr o u p W OR D S h o w s h o w m a c a c ce s s- g r ou p [ I NT E R F A C E] D e f a ul t D e s c ri p t io n T h i s c o m ma n d d e n e a n e x te n d ed MA C a c c es s l i st u si n g a n a m e , a nd en t er a cc e ss - li s t c o n g ur a t io n m o de . E x a m pl e s A S U S (c o n g - if ) # m a c a cc e ss - g ro u p a bc i n 13. ACL: IP Filter 1 3 . 1  i p  a cc e ss - li s t e x te n de d  ( < 1 0 0 - 19 9 >| < 20 0 0- 2 6 9 9 > | W O R D ) S y n t ax i p a cc e s s- l is t e x t en d ed (< 1 0 0- 1 99 > |< 2 0 00 - 26 9 9> | W OR D ) P a r a me t e rs I p Gl ob al I P c o n g u r at i on su b c om m an d s A c c e ss - l is t na me d a c ce s s- l i st e x t e nd e d e x t e n de d a c c es s -l i st < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) W O R D a ac c es s -l i st n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o i p a c ce s s- l is t ex t en d ed ( <1 0 0- 1 99 > | <2 0 00 - 26 9 9 >| W OR D ) S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d d e n e a n e x te n d ed IP a cc es s l is t u s in g a n am e o r n um b e r , an d e n te r ac c es s -l i s t c on  gu r a ti o n m od e .
GigaX2024B/M L2 Managed Switch CLI Manual 90 E x a m pl e s A S U S (c o n g ) # i p a c ce s s- l is t ex t en d ed 1 00 1 3 . 2 ip a cc es s- l i s t st an d a r d (< 1- 9 9 > | < 1 3 00 -1 9 9 9 > | W O R D ) S y n t ax i p a cc e s s- l is t s t a nd a rd (< 1 - 99 > |< 1 30 0 - 19 9 9> | WO R D ) P a r a me t e rs I p Gl ob al I P c o n g u r at i on su b c om m an d s A c c e ss - l is t na me d a c ce s s- l i st st an da rd st an da r d a cc e ss - l is t < 1 - 9 9> - > st an d ar d I P a c c e ss - li s t n u mb e r < 1 3 0 0- 1 9 99 > - > s ta nd ar d I P a c c e ss - li s t n u mb e r ( e xp a nd e d r a n g e) W O R D - > a a c c e ss - li s t n a me C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o i p a c ce s s- l is t st a nd a rd ( <1 - 99 > |< 1 3 00 - 19 9 9> | W OR D ) S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d d e n e a n s t an d a rd IP a cc es s l is t u s in g a n am e o r n um b e r , an d e n te r ac c es s -l i s t c on  gu r a ti o n m od e . E x a m pl e s AS US (c o n g )# ip a cc e ss - li s t s t an d ar d 99 1 3 . 3 s h o w ip a c c e s s - gr o u p [ I F N A M E] S y n t ax s h o w i p ac c es s -g r o up [I F NA M E ] P a r a me t e rs I F N A ME : in t er f ac e na m e C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n S h o w i p ac c es s r u l e t o a tt a c h w it h t h e s p ec i c i nt e rf a ce E x a m pl e s A S U S # s h ow ip ac c e ss - gr o up f a1 / 0/ 1 1 3 . 4 s h o w ip a c c e s s li s t S y n t ax s h o w i p ac c es s l i s t
GigaX2024B/M L2 Managed Switch CLI Manual 91 P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w i p a c ce s s l is t EX E C c om m a nd to di s p la y t h e p a r a me t e rs fo r a l l i p a c ce s s o n t h e s w it c h. E x a m pl e s A S U S # s h ow ip ac c e ss li s t 1 3 . 5  s h o w  ip  a c c e s s  l i st  W O R D S y n t ax s h o w i p ac c es s l i s t W OR D P a r a me t e rs W O R D i p a c ce s s n a me . C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w i p a c ce s s l is t s W O RD EX E C c o mm a nd t o d is p la y t h e pa r a me t er s f o r a n i p a c c es s o n t h e s w it c h. E x a m pl e s A S U S # s h ow ip ac c e ss li s t a b c 1 3 . 6 s h o w i p a c c e s s l i s t ( < 1 - 99 > |< 1 00 - 19 9 >| < 13 0 0- 1 9 9 9 > | < 2 0 0 0 - 2 6 99 > | W O R D ) S y n t ax s h o w i p ac c es s l i s t ( <1 - 99 > | <1 0 0- 1 99 > | <1 3 00 - 19 9 9 >| < 20 0 0- 2 6 9 9 > | W OR D ) P a r a me t e rs S t a n da r d o r e x te n d ed ID C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sh o w i p a c ce s s l is t EX E C c om m a nd to di s p la y t h e p a r a me t e rs fo r a n ip ac c es s on th e s w i tc h . E x a m pl e s A S U S # s h ow ip ac c e ss li s t 1 0 0 1 3 . 7 ( p e r m it | d e n y ) a ny [ I F N A M E ] S y n t ax ( p e r mi t | de n y) an y [I F NA M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd
GigaX2024B/M L2 Managed Switch CLI Manual 92 d e n y -> S p e c if y pa c ke t s t o r e je c t. a n y An y so u rc e h o s t [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P st a n da r d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) a ny [I F NA M E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - st d -n a c l) # pe r mi t an y [ f a1 / 0 /1 ] 1 3 . 8 ( p e r m it | d e n y ) h os t I P A D D R [ I F N A M E ] S y n t ax ( p e r mi t | de n y) ho s t I P A D D R [I F NA M E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. h o s t A s i n gl e h o st a dd r es s I P AD DR Ho st a dd r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P st a n da r d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) h os t I P A D D R [I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - st d -n a c l) # pe r mi t ho s t 1 0. 0 . 0. 1 [ f a1 / 0 /1 ] 1 3 . 9  ( p e r m it | d e n y )  I P A D D R M A S K  [ I F NA M E ] S y n t ax ( p e r mi t | de n y) IP AD DR M AS K [ I F NA M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t.
GigaX2024B/M L2 Managed Switch CLI Manual 93 h o s t A s i n gl e h o st a dd r es s I P AD DR Ho st a dd r es s M A S K Wi ld c ar d bi t s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P st a n da r d a cc e s s- l is t t e r mi n al mo d e N o / c le a r n o ( pe r m it | de n y) h os t I P A D D R A . B . C. D [I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - st d -n a c l) # pe r mi t 10 . 0. 0 .1 0 .0 . 0. 0 [ f a 1/ 0 /1 ] 1 3 . 1 0 ( p e r m i t | d e n y ) ( i p | t c p | u d p | i c m p ) a n y a n y [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (i p | tc p |u d p| i c mp ) a n y a n y [ IF N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol a n y an y so u rc e a d d re s s a n y an y de s ti n at i o n a dd r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( ip | tc p |u d p |i c mp ) a n y a n y [ IF N A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or
GigaX2024B/M L2 Managed Switch CLI Manual 94 p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i p a ny an y [f a 1/ 0 /1 ] 1 3 . 1 1 ( p er m it |d eny ) (tc p| u dp ) any [e q] [< 0- 6 55 35 >] a n y [ e q ] [ < 0 - 6 55 3 5 > ] [ I F NA M E ] S y n t ax ( p er m i t| de n y ) ( t c p| u d p) a n y [ e q ] [ < 0 -6 55 3 5 >] a n y [ e q] [ < 0- 6 5 53 5> ] [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l a n y an y so u rc e a d d re s s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er a n y an y de s ti n at i o n a dd r es s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) a ny [e q ] [ < 0- 6 55 3 5> ] an y [ e q] [ < 0 - 65 5 3 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp an y e q 10 0 a n y e q 1 0 0 [ fa 1 / 0/ 1 ] 1 3 . 1 2 ( permit|d eny) icmp any any [<1-2 55>] code [ < 1 - 2 5 5 > ] [ I F N AM E ] S y n t ax ( p e r mi t | de n y) ic m p a n y a ny [ <1 - 25 5 >] c od e [ < 1- 2 5 5> ] [ I FN A M E]
GigaX2024B/M L2 Managed Switch CLI Manual 95 P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. Ic mp -> In t e rn e t C on t r ol Me s sa g e P r ot o co l a n y an y so u rc e a d d re s s a n y an y de s ti n at i o n a dd r es s < 1 - 2 55 > IC MP m es sa ge t y p e < 1 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p a n y a n y [ <1 - 25 5 > ] c od e [ < 1 -2 5 5> ] [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i cm p a n y a n y 1 2 c od e 12 [f a 1/ 0 / 1] 1 3 . 1 3  ( p e r m i t | d e n y )  ( i p | t c p | u d p | i c m p )  I P A D D R  M A S K  a n y [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (i p | tc p |u d p| i c mp ) I P A D D R MA S K a n y [ IF N A ME ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s a n y an y de s ti n at i o n a dd r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e
GigaX2024B/M L2 Managed Switch CLI Manual 96 C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( ip | tc p |u d p |i c mp ) I P A D D R M AS K a n y [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i p 1 0. 0 .0 . 1 0 . 0. 0 .0 a ny [f a 1/ 0 / 1] 1 3 . 1 4  ( perm it|de ny) (t cp|u dp) IP A DDR MA SK [eq] [ < 0 - 6 5 5 3 5 > ] a n y [ e q ] [ < 0 -6 5 5 3 5 > ] [ I F NA M E ] S y n t ax ( p e r mi t |d en y ) ( tc p| u dp ) I P A D D R MA SK [e q] [< 0 -6 5 53 5 >] an y [ eq ] [ < 0 - 65 5 3 5> ] [ I FN A M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er a n y an y de s ti n at i o n a dd r es s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) I P AD DR M AS K [e q ] [ <0 - 6 55 3 5> ] a n y [ e q ] [ < 0 -6 5 53 5 >] [ IF N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d .
GigaX2024B/M L2 Managed Switch CLI Manual 97 E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp 10 . 0. 0 . 1 0 .0 . 0. 0 eq 12 an y eq 1 2 [ fa 1 / 0/ 1 ] 1 3 . 1 5  ( p e r m i t | d e n y )  i c m p  I PA D D R  M A S K  a n y < 1 - 2 5 5 > c o d e < 1- 2 5 5 > [ I F NA M E ] S y n t ax ( p er mi t | d en y) i c mp I P A D DR M A S K a n y [< 1- 2 5 5 >] c o de [ < 1 - 25 5> ] [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s a n y an y de s ti n at i o n a dd r es s < 1 - 2 55 > IC MP m es sa ge t y p e < 1 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p I P A D D R MA S K a n y [ <1 - 2 55 > ] c od e [ < 1 - 25 5 > ] [ IF N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i cm p 1 0 .0 . 0 .1 0. 0 .0 . 0 a n y 1 2 c o de 1 2 [ fa 1 / 0/ 1 ] 1 3 . 1 6 (p e r m i t | d e n y) ( i p | t c p | u d p| i c m p ) ho s t IP AD D R a n y [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (i p | tc p |u d p| i c mp ) h o st I P AD DR a ny [ IF N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t.
GigaX2024B/M L2 Managed Switch CLI Manual 98 I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss . a n y an y de s ti n at i o n a dd r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r N o ( pe r m it | de n y) ( ip | tc p |u d p |i c mp ) h o s t I P AD DR a n y [ IF N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i p h os t 1 0 . 0. 0 .1 an y [f a 1/ 0 /1 ] 1 3 . 1 7 ( p e r m i t | d e n y ) ( t c p | u d p ) h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ] a n y [ e q ] [ < 0 -6 5 5 3 5 > ] [ I F NA M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) ho s t I P A D D R [e q ] [ < 0- 6 55 3 5> ] an y [ e q] [ < 0 - 65 5 3 5> ] [ I FN A M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss . e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er a n y an y de s ti n at i o n a dd r es s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e
GigaX2024B/M L2 Managed Switch CLI Manual 99 < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( p e rm it | d en y ) (t c p |u d p ) h o s t I P A D DR [ e q] [ <0 - 6 55 35 > ] a n y [ e q ] [ < 0 - 65 5 3 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp ho s t 1 0 .0 . 0. 1 e q 6 a ny eq 6 5 [ f a 1 /0 / 1 ] 1 3 . 1 8 ( p e r m i t | d e n y ) i c m p h o s t I P A D D R a n y [ < 1 - 2 5 5 > ] c o d e [ < 1 - 2 5 5 > ] [ I F N A M E ] S y n t ax ( p e r mi t | de n y) ic m p h o st IP AD DR a ny [< 1 - 25 5 >] co d e [ <1 - 25 5 > ] [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss . a n y an y de s ti n at i o n a dd r es s < 1 - 2 55 > IC MP m es sa ge t y p e < 1 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r N o ( pe r m it | de n y) i cm p h o st I P AD DR a ny [< 1 -2 5 5> ] co d e [ < 1 - 25 5 > ] [ IF N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or
GigaX2024B/M L2 Managed Switch CLI Manual 100 p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t ic m p h os t 10 . 0. 0 .1 a ny 12 co d e 1 2 [ fa 1 / 0/ 1 ] 1 3 . 1 9 (p e r m i t | d e n y) ( i p | t c p | u d p| i c m p ) ho s t IP AD D R h o s t I P A D D R [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (i p | tc p |u d p| i c mp ) h o st I P AD DR h os t IP AD DR [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( ip | tc p |u d p |i c mp ) h o s t I P AD DR h o st IP AD DR [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i cm p h o st 1 0. 0 .0 . 1 h o st 10 . 0. 0 . 25 [ f a 1 /0 / 1 ]
GigaX2024B/M L2 Managed Switch CLI Manual 101 1 3 . 2 0 ( p e r m i t | d e n y ) ( t c p | u d p ) h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ] h o st I P A D D R [ e q ] [ < 0 - 65 5 3 5 > ] [ I F N AM E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) ho s t I P A D D R [e q ] [ < 0- 6 55 3 5> ] ho s t I P AD DR [ e q] [< 0 -6 5 5 35 > ] [ IF N A ME ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) h os t I P A D D R [e q ] [ < 0- 6 55 3 5 >] ho s t I P AD DR [ e q] [< 0 -6 5 5 35 > ] [ IF N A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p h o st 1 0. 0 .0 . 1 e q 6 5 5 h os t 1 0 . 0 .0 . 2 e q 6 5 [ f a 1/ 0 /2 ] 1 3 . 2 1 (p e r m i t | d e ny ) i c m p h os t I P A D D R h o s t I P A D D R [ < 1 - 2 5 5 > ] c o d e [ < 1 - 2 5 5 > ] [ I F N A M E ] S y n t ax ( p e r mi t | de n y) ic m p h o st IP AD DR h os t I P A D D R [ <1 - 25 5 >] c od e
GigaX2024B/M L2 Managed Switch CLI Manual 102 [ < 1 - 25 5 > ] [ IF N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s < 1 - 2 55 > IC MP m es sa ge t y p e < 1 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p h o st I P AD DR h os t IP AD DR [ <1 - 25 5 >] c o d e [ < 1 -2 5 5> ] [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i cm p h o st 1 0. 0 .0 . 1 h o st 10 . 0. 0 . 2 2 c o d e 2 [ fa 1 /0 / 1] 1 3 . 2 2  ( p e r m i t | d e n y )  ( i p | t c p | u d p | i c m p )  I P A D D R  M A S K  I P A D D R  M A S K  [ I F N AM E ] S y n t ax ( p e r mi t | de n y) (i p | tc p |u d p| i c mp ) I P A D D R MA S K I P A D D R MA S K [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol
GigaX2024B/M L2 Managed Switch CLI Manual 103 I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( ip | tc p |u d p |i c mp ) I P A D D R M AS K I P A D D R M A S K [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i p 1 0. 0 .0 . 1 0 . 0. 0 .0 1 0. 0 .0 . 2 0 . 0. 0 .0 [ f a 1 /0 / 1 ] 1 3 . 2 3  ( p e r m i t | d e n y )  ( t c p | u d p )  I PA D D R  M A S K  [e q]  [ <0 - 65 5 35 >]  I P A DD R  MA S K [ e q]  [ <0 - 65 53 5 >]  [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p| ) I P A D D R M AS K [ e q] [ <0 - 65 5 35 > ] I P AD DR M A SK [e q ] [ < 0- 6 55 3 5> ] [I F NA M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T ra ns mi ss i on C on t ro l P r o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk
GigaX2024B/M L2 Managed Switch CLI Manual 104 e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p| ) IP AD DR M AS K [ e q] [< 0 - 65 5 35 > ] I P AD DR M A SK [e q ] [ < 0- 6 55 3 5> ] [I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p 1 0 .0 . 0 .1 0. 0 .0 . 0 e q 2 10 . 0 .0 . 2 0 . 0 . 0. 0 eq 3 [ fa 1 / 0/ 1 ] 1 3 . 2 4  ( perm it| deny ) ic mp IP A DDR  MASK  IP ADD R  M A S K  < 1 - 2 5 5 >  c o d e < 1 - 2 5 5 >  [ I FN A M E ] S y n t ax ( p e r mi t | de n y) ic m p I P A D D R MA S K I P A D D R MA S K < 1- 2 5 5> c o d e < 1 - 25 5 > [ IF N A ME ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk < 1 - 2 55 > IC MP m es sa ge t y p e < 1 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p I P A D D R MA S K I P A D D R MA S K < 1 -2 5 5> c o d e < 1 - 25 5 > [ IF N A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e]
GigaX2024B/M L2 Managed Switch CLI Manual 105 D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i cm p 1 0 .0 . 0 .1 0. 0 .0 . 0 1 0 .0 . 0. 2 0 . 0 . 0. 0 2 c od e 2 [ fa 1 /0 / 2] 1 3 . 2 5 (p e r m i t | d e n y) ( i p | t c p | u d p| i c m p ) ho s t IP AD D R I P A D D R  M A S K  [ I F N AM E ] S y n t ax ( p e r mi t | de n y) (i p | tc p |u d p| i c mp ) h o st I P AD DR I P AD DR M A SK [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. h o s t A s i n gl e s o ur c e h o st I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( ip | tc p |u d p |i c mp ) h o s t I P AD DR I P A D D R MA S K [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp ho s t 1 0 .0 . 0. 1 1 0 . 0. 0 .2 0. 0 . 0. 0 [ f a 1 /0 / 2 ]
GigaX2024B/M L2 Managed Switch CLI Manual 106 1 3 . 2 6 ( p e r m i t | d e n y ) ( t c p | u d p ) h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ]  I PA D D R  M A S K  [ e q ]  [ < 0 - 6 5 5 3 5 > ]  [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) ho s t I P A D D R [e q ] [ < 0- 6 55 3 5> ] IP AD DR M A S K [ e q ] [ <0 - 65 5 3 5> ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) h os t I P A D D R [e q ] [ < 0- 6 55 3 5 >] I P AD DR M A SK [e q ] [ < 0- 6 55 3 5> ] [I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p h o st 1 0. 0 .0 . 1 e q 2 10 . 0. 0 . 2 0 . 0 . 0. 0 eq 2 [ fa 1 / 0/ 2 ]
GigaX2024B/M L2 Managed Switch CLI Manual 107 1 3 . 2 7 ( p e r m i t | d e n y ) i c m p h o s t I P A D D R I P A D D R M A S K  < 1 - 2 5 5 >  c o d e < 1 - 2 5 5 >  [ I FN A M E ] S y n t ax ( p e r mi t | de n y) ic m p h o st IP AD DR I P AD DR M A SK <1 - 25 5 > c o de < 1 - 2 55 > [I F NA M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk < 1 - 2 55 > IC MP m es sa ge t y p e < 1 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p h o st I P AD DR I P AD DR M A SK <1 - 2 55 > c o d e < 1 - 25 5 > [ IF N A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t ic m p h os t 10 . 0. 0 .1 1 0. 0 .0 . 2 0 . 0. 0 .0 2 c o de 2 [ f a1 / 0/ 2 ] 1 3 . 2 8  ( p e r m i t | d e n y )  ( i p | t c p | u d p | i c m p )  I P A D D R  M A S K  h o s t I P A D D R [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (i p | tc p |u d p| i c mp ) I P A D D R MA S K h o st IP AD DR [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t.
GigaX2024B/M L2 Managed Switch CLI Manual 108 I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( ip | tc p |u d p |i c mp ) I P A D D R M AS K h o st I P AD DR [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp 10 . 0. 0 . 1 0 .0 . 0. 0 ho s t 1 0. 0 . 0. 2 [ f a 1 /0 / 2 ] 1 3 . 2 9  ( perm it|de ny) (t cp|u dp) IP A DDR MA SK [eq] [ < 0 - 6 5 5 3 5 > ] h o st I P A D D R [ e q ] [ < 0 - 65 5 3 5 > ] [ I F N AM E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) IP AD DR M AS K [ e q ] [ <0 - 65 5 3 5> ] h o st I P AD DR [ e q] [< 0 -6 5 5 35 > ] [ IF N A ME ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er
GigaX2024B/M L2 Managed Switch CLI Manual 109 h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) I P AD DR M AS K [e q ] [ <0 - 6 55 3 5> ] h o s t I P AD DR [ e q] [< 0 -6 5 5 35 > ] [ IF N A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p 1 0 .0 . 0 .1 0. 0 .0 . 0 e q 6 5 h o s t 1 0 . 0 .0 . 2 e q 6 4 [ f a 1/ 0 /2 ] 1 3 . 3 0  ( p e r m i t | d e n y )  i c m p  I P A D D R  M A S K  h o s t  I P A D D R < 1 - 2 5 5 > c od e < 1 - 2 5 5 > [I F N A M E ] S y n t ax ( p e r mi t | de n y) ic m p I P A D D R MA S K h o st IP AD DR < 1- 2 55 > c o d e < 1 - 2 55 > [I F NA M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s < 1 - 2 55 > IC MP m es sa ge t y p e < 1 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p I P A D D R MA S K h o st IP AD DR < 1- 2 55 >
GigaX2024B/M L2 Managed Switch CLI Manual 1 10 c o d e < 1 - 25 5 > [ IF N A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t ic m p 1 0. 0 . 0. 1 0 . 0. 0 . 0 h os t 1 0 . 0. 0 .2 1 c o de 1 [ f a1 / 0/ 2 ] 1 3 . 3 1 ( p e r m i t | d e n y ) ( i p | t c p | u d p | i c m p ) a n y h o s t I P A D D R [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (i p | tc p |u d p| i c mp ) a n y h o st A . B . C. D [ I F NA M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol a n y an y so u rc e a d d re s s h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( ip | tc p |u d p |i c mp ) a n y h o st IP AD DR [ IF N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp an y h o s t 1 0. 0 .0 . 1 [ f a1 / 0/ 2 ]
GigaX2024B/M L2 Managed Switch CLI Manual 1 1 1 1 3 . 3 2 (pe rm i t| de ny) (tc p |u dp ) any [eq ] [<0 -6 5 53 5> ] h o s t I P A D D R [ e q ] [ < 0 - 6 5 53 5 > ] [ I F N AM E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) an y [e q ] [ <0 - 6 55 3 5> ] h o s t I P AD DR [ e q] [ < 0 - 65 5 3 5> ] [ I FN A M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol . a n y an y so u rc e ad d re s s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er . h o s t A s in g le de s ti n a ti o n h os t I P AD DR De st in at i on ad d r es s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( p e rm it | d en y ) (t c p |u d p ) a n y [ e q ] [ < 0- 6 5 53 5> ] ho s t I P AD D R [e q ] [ < 0 - 65 5 3 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p a n y e q 1 2 h o st 1 0. 0 .0 . 1 e q 1 2 [ f a 1 /0 / 2 ]
GigaX2024B/M L2 Managed Switch CLI Manual 1 12 1 3 . 3 3 (p e r m i t | d e ny ) i cm p a ny h o s t IP A D DR < 1 - 2 5 5 > c o d e < 1 - 2 5 5 > [ IF N A M E ] S y n t ax ( p e r mi t | de n y) ic m p a n y h os t IP AD DR < 1- 2 55 > c o de < 1- 2 55 > [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol a n y an y so u rc e a d d re s s h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s < 1 - 2 55 > IC MP m es sa ge t y p e < 1 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p a n y h o st IP AD DR < 1- 2 55 > c o d e < 1- 2 55 > [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t ic m p a ny h os t 1 0 .0 . 0 .1 2 c od e 2 [ f a 1 /0 / 2 ] 1 3 . 3 4 (perm it| de ny) (ip| tcp |u dp| ic mp) any IP ADDR M A S K  [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (i p | tc p |u d p| i c mp ) a n y I P A D D R MA S K [ IF N A ME ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd
GigaX2024B/M L2 Managed Switch CLI Manual 1 13 d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol a n y an y so u rc e a d d re s s I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( ip | tc p |u d p |i c mp ) a n y I P A D D R MA S K [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp an y 1 0 . 0. 0 .1 0. 0 . 0. 0 [ f a1 / 0 /2 ] 1 3 . 3 5 (pe rm i t| de ny) (tc p |u dp ) any [eq ] [<0 -6 5 53 5> ] I P A D D R  M A S K  [ e q ] [ < 0 - 6 5 5 3 5 > ]  [ IF N A M E ] S y n t ax ( p e r mi t |d en y ) ( tc p| u dp ) a n y [ eq ] [ <0 - 65 5 35 > ] I P AD DR M AS K [ eq ] [ < 0 - 65 5 3 5> ] [ I FN A M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l a n y an y so u rc e a d d re s s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk
GigaX2024B/M L2 Managed Switch CLI Manual 1 14 e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) a ny [e q ] [ < 0- 6 55 3 5> ] IP AD DR M AS K [ e q ] [ < 0 -6 5 53 5 >] [ IF N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p a n y e q 6 5 1 0 .0 . 0 .1 0. 0 .0 . 0 e q 4 3 [ fa 1 / 0/ 2 ] 1 3 . 3 6  ( p e r m i t | d e n y )  i c m p  a n y  I PA D D R  M A S K  < 1 - 2 5 5 > c o d e < 1- 2 5 5 > [ I F NA M E ] S y n t ax ( p e r mi t | de n y) ic m p a n y I P AD DR M A SK <1 - 2 55 > c o de < 1- 2 55 > [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol a n y an y so u rc e a d d re s s I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p a n y I P A D D R MA S K < 1- 2 5 5> co d e < 1 - 2 55 > [I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d .
GigaX2024B/M L2 Managed Switch CLI Manual 1 15 E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t ic m p a ny 1 0. 0 .0 . 1 0 . 0. 0 .0 2 c o de 3 [ f a 1 /0 / 2 ] 1 3 . 3 7  ( p e r m i t | d e n y )  ( t c p | u d p )  I PA D D R  M A S K  I P A D D R  M A S K  [ e q ] [ < 0 - 6 5 5 3 5 > ]  [ IF N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p| ) I P A D D R M AS K I P A D D R MA S K [ e q] [ < 0 - 65 5 3 5> ] [ I FN A M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p| ) IP AD DR M AS K I P A D D R MA S K [ e q] [ < 0 - 65 5 3 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S( c on g - ex t- a cl )# p er mi t t cp 10 .0 . 0. 1 0 .0 .0 . 0 10 . 0. 0. 2 0 .0 . 0. 0 e q 2 3 [ f a1 / 0/ 1 ] 1 3 . 3 8  ( perm it|de ny) (t cp|u dp) IP A DDR MA SK [eq] [ < 0 - 6 5 5 3 5 > ]  I P A D D R  M A S K  [ IF N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p| ) I P A D D R M AS K [ e q] [ <0 - 65 5 35 > ]
GigaX2024B/M L2 Managed Switch CLI Manual 1 16 I P AD DR M A SK [I F NA M E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p| ) IP AD DR M AS K [ e q] [< 0 - 65 5 35 > ] I P AD DR M A SK [I F NA M E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p 1 0 .0 . 0 .1 0. 0 .0 . 0 e q 2 3 1 0 . 0. 0 .2 0 . 0 . 0. 0 [f a 1/ 0 /1 ] 1 3 . 3 9 (p e r m i t | d e n y ) (t c p | u d p ) I P AD DR A . B . C . D [ e q ] [ < 0 - 6 5 5 3 5 > ] a n y [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) IP AD DR M AS K [ e q ] [ <0 - 65 5 3 5> ] a n y [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss
GigaX2024B/M L2 Managed Switch CLI Manual 1 17 M A S K So ur c e w i ld c ar d b i t s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er a n y an y de s ti n at i o n a dd r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) I P AD DR M AS K [e q ] [ <0 - 6 55 3 5> ] a n y [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp 10 . 0. 0 . 1 0 .0 . 0. 0 eq 22 an y [ f a 1 /0 / 1 ] 1 3 . 4 0  ( pe rm it| de ny ) ( tcp |u dp)  IP AD DR  MAS K a ny  [ e q ] [ < 0 - 6 5 5 3 5 >] [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) IP AD DR M AS K a n y [ e q] [< 0 - 65 5 35 > ] [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s a n y an y de s ti n at i o n a dd r es s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) I P AD DR M AS K an y [ e q] [ <0 - 65 5 35 > ]
GigaX2024B/M L2 Managed Switch CLI Manual 1 18 [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p 1 0 .0 . 0 .1 0. 0 .0 . 0 a n y e q 2 2 [ f a 1 /0 / 1 ] 1 3 . 4 1  ( perm it|de ny) (t cp|u dp) IP A DDR MA SK [eq] [ < 0 - 6 5 5 3 5 > ] h o st I P A D D R [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) IP AD DR M AS K [ e q ] [ <0 - 65 5 3 5> ] h o st I P AD DR [ I FN A ME ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) I P AD DR M AS K [e q ] [ <0 - 6 55 3 5> ] h o s t I P AD DR [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp 10 . 0. 0 . 1 0 .0 . 0. 0 eq 2 h os t
GigaX2024B/M L2 Managed Switch CLI Manual 1 19 1 0 . 0 .0 . 2 [ f a1 / 0/ 1 ] 1 3 . 4 2  (permit |den y) (tcp|u dp) IP ADDR MASK host  I P A D D R [ e q ] [ < 0 - 65 5 3 5 > ] [ I F N AM E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) IP AD DR M AS K h o s t I P AD DR [ e q] [ < 0 - 65 5 3 5> ] [ I FN A M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) I P AD DR M AS K ho s t I P AD DR [ e q] [ < 0 - 65 5 3 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p 1 0 .0 . 0 .1 0. 0 .0 . 0 h o st 10 . 0 .0 . 2 e q 2 [ f a 1/ 0 /1 ] 1 3 . 4 3 (pe rm i t| de ny) (tc p |u dp ) any [eq ] [<0 -6 5 53 5> ] I P A D D R  M A S K  [ I F N AM E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) an y [e q ] [ <0 - 6 55 3 5> ] I P A D D R M AS K [ I F N AM E ]
GigaX2024B/M L2 Managed Switch CLI Manual 120 P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l a n y an y so u rc e a d d re s s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) a ny [e q ] [ < 0- 6 55 3 5> ] IP AD DR M AS K [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp an y e q 2 1 0. 0 .0 . 1 0 . 0. 0 .0 [ f a 1 /0 / 1 ] 1 3 . 4 4  ( pe rm it| de ny ) ( tcp |u dp)  an y I P AD DR  MA SK  [ e q ] [ < 0 - 6 5 5 3 5 >] [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) an y IP AD DR M AS K [ e q] [< 0 - 65 5 35 > ] [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l a n y an y so u rc e a d d re s s I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk
GigaX2024B/M L2 Managed Switch CLI Manual 121 e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) a ny IP AD DR M AS K [ e q] [ <0 - 65 5 35 > ] [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p a n y 1 0 .0 . 0. 1 0 . 0 .0 . 0 e q 2 [ f a 1 /0 / 1 ] 1 3 . 4 5 ( p e r m i t | d e n y ) ( t c p | u d p ) a n y a n y [ e q ] [ < 0 - 6 5 5 3 5 > ] [ I FN A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) an y an y [ e q] [ <0 - 65 5 35 > ] [ I FN A ME ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l a n y an y so u rc e a d d re s s a n y an y de s ti n at i o n a dd r es s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) a ny an y [ e q ] [ <0 - 65 5 3 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d .
GigaX2024B/M L2 Managed Switch CLI Manual 122 E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp an y a n y e q 2 [f a 1 /0 / 1] 1 3 . 4 6 (pe rm i t| de ny) (tc p |u dp ) any [eq ] [<0 -6 5 53 5> ] a n y [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) an y [e q ] [ <0 - 6 55 3 5> ] a n y [ I FN A ME ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l a n y an y so u rc e a d d re s s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er a n y an y de s ti n at i o n a dd r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) a ny [e q ] [ < 0- 6 55 3 5> ] an y [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p a n y e q 2 a ny [f a 1 /0 / 1] 1 3 . 4 7 (pe rm i t| de ny) (tc p |u dp ) any [eq ] [<0 -6 5 53 5> ] h o s t I P A D D R [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) an y [e q ] [ <0 - 6 55 3 5> ] h o s t I P AD DR [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol
GigaX2024B/M L2 Managed Switch CLI Manual 123 U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol . a n y an y so u rc e ad d re s s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er . h o s t A s in g le de s ti n a ti o n h os t I P AD DR De st in at i on ad d r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) a ny [e q ] [ < 0- 6 55 3 5> ] ho s t I P AD DR [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp an y e q 2 h os t 1 0 . 0. 0 .2 [f a 1 /0 / 1] 1 3 . 4 8 (p e r m i t | d e ny ) ( tc p | u d p ) a ny h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ] [ I FN A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) an y ho s t I P AD DR [ e q] [< 0 - 65 5 35 > ] [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol a n y an y so u rc e a d d re s s h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s
GigaX2024B/M L2 Managed Switch CLI Manual 124 e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) a ny ho s t I P A D D R [e q ] [ <0 - 6 55 3 5> ] [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p a n y h o st 10 . 0. 0 . 2 e q 2 [ f a 1/ 0 /1 ] 1 3 . 4 9 ( p e r m i t | d e n y ) ( t c p | u d p ) h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ] h o st I P A D D R [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) ho s t I P A D D R [e q ] [ < 0- 6 55 3 5> ] ho s t I P AD DR [ I FN A ME ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) h os t I P A D D R [e q ] [ < 0- 6 55 3 5 >] ho s t I P AD DR [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e]
GigaX2024B/M L2 Managed Switch CLI Manual 125 D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp ho s t 1 0 .0 . 0. 1 e q 2 h os t 1 0 . 0. 0 .2 [ f a 1 /0 / 1 ] 1 3 . 5 0 ( p e r m i t | d e n y ) ( t cp |u d p ) h o s t I P A D D R h o s t I P A D D R [ e q ] [ < 0 - 65 5 3 5 > ] [ I F N AM E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) ho s t I P A D D R ho s t I P A D D R [e q ] [ < 0 - 65 5 3 5> ] [ I FN A M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) h os t I P A D D R ho s t I P A D D R [e q ] [ < 0 - 65 5 3 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p h o st 1 0. 0 .0 . 1 h o st 10 . 0. 0 . 2 e q 2 [ f a1 / 0 /1 ]
GigaX2024B/M L2 Managed Switch CLI Manual 126 1 3 . 5 1 ( p e r m i t | d e n y ) ( t c p | u d p ) h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ]  I P A D D R  M A S K  [ IF N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) ho s t I P A D D R [e q ] [ < 0- 6 55 3 5> ] IP AD DR M A S K [ I F NA M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) h os t I P A D D R [e q ] [ < 0- 6 55 3 5 >] I P AD DR M A SK [I F NA M E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp ho s t 1 0 .0 . 0. 1 e q 2 1 0. 0 .0 . 2 0 . 0 . 0. 0 [f a 1/ 0 /1 ] 1 3 . 5 2 (p e rm i t| d e n y) ( t c p |u d p ) h o s t I P A D D R I P A D D R M A S K  [ e q ]  [ < 0 - 65 5 3 5 > ]  [ I F N AM E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) ho s t I P A D D R IP AD DR M AS K [ e q] [ < 0 - 65 5 3 5> ] [ I FN A M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd
GigaX2024B/M L2 Managed Switch CLI Manual 127 d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) h os t I P A D D R IP AD DR M AS K [ e q ] [ < 0 - 65 5 3 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p h o st 1 0. 0 .0 . 1 1 0 .0 . 0. 2 0 . 0 .0 . 0 e q 2 [ f a 1/ 0 /1 ] 1 3 . 5 3 ( p e r m i t | d e n y ) ( t c p | u d p ) h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ] a n y [ I F N A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) ho s t I P A D D R [e q ] [ < 0- 6 55 3 5> ] an y [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss . e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e
GigaX2024B/M L2 Managed Switch CLI Manual 128 < 0 - 6 55 3 5 > Po rt n um b er a n y an y de s ti n at i o n a dd r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) h os t I P A D D R [e q ] [ < 0- 6 55 3 5 >] an y [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it t cp ho s t 1 0 .0 . 0. 1 e q 2 a ny [f a 1 /0 / 1] 1 3 . 5 4 (p e r m i t | d e ny ) ( tc p | u d p ) h os t I P A DD R a ny [ e q ] [ < 0 - 6 5 5 3 5 > ] [ I FN A M E ] S y n t ax ( p e r mi t | de n y) (t c p |u d p) ho s t I P A D D R an y [ e q ] [ <0 - 65 5 3 5> ] [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss . a n y an y de s ti n at i o n a dd r es s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) ( tc p |u d p) h os t I P A D D R an y [e q ] [ <0 - 6 55 3 5> ] [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t
GigaX2024B/M L2 Managed Switch CLI Manual 129 D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t tc p h o st 1 0. 0 .0 . 1 a n y e q 2 [ f a 1/ 0 /1 ] 1 3 . 5 5  ( perm it| deny ) ic mp IP A DDR  MASK  IP ADD R  M A S K  < 1 - 2 5 5 >  [ I F NA M E ] S y n t ax ( p e r mi t | de n y) ic m p I P A D D R MA S K I P A D D R MA S K < 1- 2 5 5> [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk < 1 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p I P A D D R MA S K I P A D D R MA S K < 1 -2 5 5> [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i cm p 1 0 .0 . 0 .1 0. 0 .0 . 0 1 0 .0 . 0. 2 0 . 0 . 0. 0 2 [ fa 1 /0 / 1 ] 1 3 . 5 6 ( p e r m i t | d e n y ) i c m p h o s t I P A D D R I P A D D R M A S K  < 1 - 2 5 5 >  [ I F NA M E ] S y n t ax ( p e r mi t | de n y) ic m p h o st IP AD DR I P AD DR M A SK <1 - 25 5 > [ I F N AM E ]
GigaX2024B/M L2 Managed Switch CLI Manual 130 P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk < 0 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p h o st I P AD DR I P AD DR M A SK <1 - 2 55 > [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t ic m p h os t 10 . 0. 0 .1 1 0. 0 .0 . 2 0 . 0. 0 .0 2 [ f a1 / 0 /1 ] 1 3 . 5 7  ( p e r m i t | d e n y )  i c m p  I P A D D R  M A S K  h o s t  I P A D D R < 1 - 2 5 5 > [ IF N A M E ] S y n t ax ( p e r mi t | de n y) ic m p I P A D D R MA S K h o st IP AD DR < 1- 2 55 > [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k h o s t A s i n gl e d e st i n at i on ho s t I P AD DR De st in at i on ad d r es s < 1 - 2 55 > IC MP m es sa ge t y p e
GigaX2024B/M L2 Managed Switch CLI Manual 131 [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p I P A D D R MA S K h o st IP AD DR < 1- 2 55 > [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t ic m p 1 0. 0 . 0. 1 0 . 0. 0 . 0 h os t 1 0 . 0. 0 .2 2 [ f a1 / 0 /1 ] 1 3 . 5 8 (p e r m i t | d e ny ) i cm p a ny h o s t IP A D DR < 1 - 2 5 5 > [ I F N A M E ] S y n t ax ( p e r mi t | de n y) ic m p a n y h os t IP AD DR < 1- 2 55 > [ I FN A M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol . a n y an y so u rc e ad d re s s . h o s t A s in g le de s ti n a ti o n h os t I P AD DR De st in at i on ad d r es s < 1 - 25 5 > IC MP m e s sa g e t y pe [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p a n y h o st IP AD DR < 1- 2 55 > [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d .
GigaX2024B/M L2 Managed Switch CLI Manual 132 E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i cm p a n y h o st 10 . 0. 0 . 1 2 [ f a1 / 0 /1 ] 1 3 . 5 9  ( p e r m i t | d e n y )  i c m p  a n y  I PA D D R  M A S K  < 1 - 2 5 5 > [ I F N A M E] S y n t ax ( p e r mi t | de n y) ic m p a n y I P AD DR M A SK <1 - 2 55 > [ I FN A M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol a n y an y so u rc e a d d re s s I P AD DR De st in at i on ad d r es s M A S K De st i na t i on ad d re s s m a sk < 1 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p a n y I P A D D R MA S K < 1- 2 5 5> [I F NA M E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# pe r mi t ic m p a ny 1 0. 0 .0 . 1 0 . 0. 0 .0 2 [ f a 1 /0 / 1 ] 1 3 . 6 0 ( p e r m i t | d e n y ) i c m p a n y a n y [ < 1 - 2 5 5 > ] [ I F N A M E ] S y n t ax ( p e r mi t | de n y) ic m p a n y a ny [ <1 - 25 5 >] [ IF N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol a n y an y so u rc e a d d re s s a n y an y de s ti n at i o n a dd r es s
GigaX2024B/M L2 Managed Switch CLI Manual 133 < 1 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) I CM P a n y an y [ < 1- 2 5 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i cm p a n y a n y 2 [ f a1 / 0 /1 ] 1 3 . 6 1  ( p e r m i t | d e n y )  i c m p  I PA D D R  M A S K  a n y [ < 1 - 2 5 5 > ] [ I F N AM E ] S y n t ax ( p e r mi t | de n y) ic m p I P A D D R MA S K a n y [ <1 - 25 5 > ] [ IF N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s a n y an y de s ti n at i o n a dd r es s < 1 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p I P A D D R MA S K a n y [ <1 - 2 55 > ] [ IF N A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S US (c on  g - ex t- ac l ) # pe rm i t ic mp 1 0 . 0 .0 .1 0 . 0 . 0. 0 an y 2 [ fa 1 / 0 /1 ]
GigaX2024B/M L2 Managed Switch CLI Manual 134 1 3 . 6 2 ( p e r m i t | d e n y ) i c m p h o s t I P A D D R a n y [ < 1 - 2 5 5 > ] [ I F N A M E ] S y n t ax ( p e r mi t | de n y) ic m p h o st IP AD DR a ny [< 1 - 25 5 >] [I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss . a n y an y de s ti n at i o n a dd r es s < 1 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r N o ( pe r m it | de n y) i cm p h o st I P AD DR a ny [< 1 -2 5 5> ] [I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i cm p h o st 1 0. 0 .0 . 1 a n y 2 [ f a1 / 0 /1 ] 1 3 . 6 3 (p e r m i t | d e ny ) i c m p h os t I P A D D R h o s t I P A D D R [ < 1 - 2 5 5 > ] [ I F N AM E ] S y n t ax ( p e r mi t | de n y) ic m p h o st A . B . C. D ho s t A . B . C .D [ <1 - 25 5 >] [ I F N AM E ] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol h o s t A s i n gl e s o ur c e h o st I P AD DR So ur ce a d dr e ss h o s t A s i n gl e d e st i n at i on ho s t
GigaX2024B/M L2 Managed Switch CLI Manual 135 I P AD DR De st in at i on ad d r es s < 1 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P ex t e nd e d a cc e s s- l is t m o d e N o / c le a r n o ( pe r m it | de n y) i cm p h o st I P AD DR h os t IP AD DR [ <1 - 25 5 >] [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - ex t -a c l )# p er m it i cm p h o st 1 0. 0 .0 . 1 h o st 10 . 0. 0 . 2 2 [ f a 1 /0 / 1 ] 1 3 . 6 4 (p e r m i t | d e ny ) I P A D D R [ I F N A M E ] S y n t ax ( p e r mi t | de n y) A . B . C. D [I F NA M E] P a r a me t e rs p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I P AD DR Ho st a dd r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e I P st a n da r d a cc e s s- l is t t e r mi n al mo d e N o / c le a r n o ( pe r m it | de n y) h os t I P A D D R [I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g - st d -n a c l) # pe r mi t 10 . 0. 0 .1 [ fa 1 /0 / 1] 1 3 . 6 5 re m a r k . L I NE S y n t ax r e m a rk . LI N E P a r a me t e rs . L I N E d es c ri p ti o n s t ri n g C o m m an d Mo d e I P st a n da r d a cc e s s- l is t t e r mi n al mo d e
GigaX2024B/M L2 Managed Switch CLI Manual 136 N o / c le a r n o r em a r k S h o w S h o w r u n ni n g- c on  g D e f a ul t D e s c ri p t io n T h i s c o m ma n d a dd a d e sc r ip t i on to a s p ec i fy A C L gr ou p . E x a m pl e s A S U S (c o n g - st d -n a c l) # r e ma r k a b c 1 3 . 6 6 ac c es s -l i st ( < 1- 9 9> | <1 0 0- 1 99 > | < 1 3 0 0- 1 99 9 >| < 2 0 0 0 - 2 6 9 9 > ) r e m ar k . L I N E S y n t ax a c c e ss - l is t ( < 1- 9 9 >| < 10 0 -1 9 9 >| < 13 0 0- 1 9 99 > |< 2 00 0 - 26 9 9> ) r e m a rk . LI N E P a r a me t e rs . L I N E s t ri n g C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 -9 9 >| < 10 0 - 19 9 >| < 13 0 0 -1 9 99 > |< 2 0 00 - 26 9 9> ) r e m a rk . LI N E n o a cc e s s- l is t ( < 1- 9 9> | <1 0 0 -1 9 9> | <1 3 0 0- 1 99 9 >| < 2 00 0 -2 6 99 > ) r e m a rk S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d i s t o a d d a d e s cr i pt i on w it h a sp e c if y a c ce s s -l i st n u m b er . E x a m pl e s A S U S (c o n g ) # a cc e s s- l is t 2 2 re m ar k a s u s 1 3 . 6 7 a c c e s s - l i s t ( < 1 - 9 9 > | < 1 3 0 0 - 1 9 9 9 > ) ( d e n y | p e r m i t )  IP A D D R  M A S K  [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 1- 9 9 >| < 13 0 0- 1 9 99 > ) ( de n y |p e rm i t) I P AD DR A . B . C. D [I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 - 9 9> - > st an d ar d I P a c c e ss - li s t n u mb e r < 1 3 0 0- 1 9 99 > - > s ta nd ar d I P a c c e ss - li s t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd
GigaX2024B/M L2 Managed Switch CLI Manual 137 d e n y -> S p e c if y pa c ke t s t o r e je c t. I P AD DR So ur ce a d dr e ss M A S K So ur c e a d dr e ss ma s k [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 -9 9 >| < 13 0 0 -1 9 99 > ) ( d en y |p e rm i t ) I P AD DR M A S K [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) # a cc e s s- l is t 9 9 pe r mi t 1 . 1 .1 . 1 0 .2 5 5 .2 5 5. 0 1 3 . 6 8 a c c e s s - l i s t ( < 1 - 9 9 > | < 1 3 0 0 - 1 9 9 9 > ) ( d e n y | p e r m i t ) ho s t I P A D D R [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 1- 9 9 >| < 13 0 0- 1 9 99 > ) ( de n y |p e rm i t) h os t I P A D D R [ I F N AM E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 - 9 9> - > st an d ar d I P a c c e ss - li s t n u mb e r < 1 3 0 0- 1 9 99 > - > s ta nd ar d I P a c c e ss - li s t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. H o s t A s in gl e h o st a dd r es s I P AD DR So ur ce a d dr e ss [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o ac ce s s- li st (< 1- 99 >| <1 3 00 -1 99 9 >) ( de n y| pe r mi t) h os t I P A D D R [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t
GigaX2024B/M L2 Managed Switch CLI Manual 138 D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) # a cc e s s- l is t 9 9 pe r mi t h o s t 1 .1 . 1. 1 1 3 . 6 9 a c c e s s - l i s t ( < 1 - 9 9 > | < 1 3 0 0 - 1 9 9 9 > ) ( d e n y | p e r m i t ) an y [ I F N A M E] S y n t ax a c c e ss - l is t ( < 1- 9 9 >| < 13 0 0- 1 9 99 > ) ( de n y |p e rm i t) a ny [I F NA M E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 - 9 9> - > st an d ar d I P a c c e ss - li s t n u mb e r < 1 3 0 0- 1 9 99 > - > s ta nd ar d I P a c c e ss - li s t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. A n y A n y s o ur c e h os t [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 -9 9 >| < 13 0 0 -1 9 99 > ) ( d en y |p e rm i t ) a ny [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) # a cc e s s- l is t 9 9 pe r mi t a n y 1 3 . 7 0 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t )  ( i p | t c p | u d p | i c m p )  I P A D D R  M A S K  I P A D D R  M A S K  [ I F N AM E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( i p | tc p | ud p |i c mp ) IP AD DR M AS K I P A D D R MA S K [ I FN A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r
GigaX2024B/M L2 Managed Switch CLI Manual 139 < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s I P AD DR De st in at i on ad d r es s M A S K De st i na t i on wi l dc a r d b it s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( i p | tc p | ud p |i c mp ) IP AD DR M AS K I P A D D R MA S K [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) # a cc e s s- l is t 1 0 0 p e rm i t i p 1 . 1. 1 .1 0 .0 . 0. 0 1 . 1 .1 . 3 0 . 0 . 0. 0 1 3 . 7 1 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t )  ( t c p | u d p )  I P A D D R  M A S K  [ e q ] [ < 0 - 6 5 5 3 5 > ]  I PA D D R  M A S K  [ e q ]  [ < 0 - 6 5 5 3 5 > ]  [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) I P AD DR M A SK [e q ] [ < 0- 6 55 3 5> ] IP AD DR M AS K [ e q] [ < 0 - 65 5 3 5> ] [ I FN A M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y
GigaX2024B/M L2 Managed Switch CLI Manual 140 < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er I P AD DR De st in at i on ad d r es s M A S K De st i na t i on wi l dc a r d b it s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( t c p |u d p ) I P AD DR M A SK [e q ] [ < 0- 6 55 3 5> ] IP AD DR M AS K [ e q] [ < 0 - 65 5 3 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) # a cc e s s- l is t 1 0 0 p e rm i t t c p 1 .1 . 1. 1 0. 0 .0 . 0 e q 2 1 1 . 1 . 1. 3 0. 0 .0 . 0 e q 2 2 1 3 . 7 2 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) (d en y| pe rm it ) icmp  IP ADD R MA SK  IP ADDR  MAS K  < 0 - 2 5 5 > c o d e < 0- 2 5 5 > [ I F NA M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p
GigaX2024B/M L2 Managed Switch CLI Manual 141 I P AD DR M A SK IP AD DR M AS K < 0 -2 5 5 > c od e < 0 - 25 5 > [ I F N AM E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s I P AD DR De st in at i on ad d r es s M A S K De st i na t i on wi l dc a r d b it s < 0 - 2 55 > IC MP m es sa ge t y p e < 0 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p I P AD DR M A SK IP AD DR M AS K < 0 -2 5 5 > c od e < 0 - 25 5 > [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c on  g) # ac ce s s- l is t 1 00 pe rm i t ic m p 1 .1 . 1. 1 0 .0 . 0. 0 1 .1 . 1. 3 0 . 0 . 0. 0 22 co d e 3 1 3 . 7 3 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r mi t )  ( i p | t c p | u dp | i c m p )  IP AD D R  MA S K  an y  [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( i p | tc p | ud p |i c mp ) IP AD DR M AS K a n y [ IF N A ME ]
GigaX2024B/M L2 Managed Switch CLI Manual 142 P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s A n y A n y d e st i na t io n ho s t [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( i p | tc p | ud p |i c mp ) IP AD DR M AS K a n y [ IF N A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p 1 .1 . 1. 1 0. 0 .0 . 0 a n y 1 3 . 7 4 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t )  ( t c p | u d p )  I P A D D R  M A S K  [ e q ] [ < 0 - 6 5 5 3 5 > ] a n y [ e q ] [ < 0 -6 5 5 3 5 > ] [ I F NA M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) I P AD DR M AS K [e q ] [ <0 -6 5 53 5 >] a n y [ eq ] [ <0 - 65 53 5 >] [I FN A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r
GigaX2024B/M L2 Managed Switch CLI Manual 143 < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s A n y A n y d e st i na t io n ho s t [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) I P AD DR M AS K [e q ] [ <0 -6 5 53 5 >] a n y [ eq ] [ <0 - 65 53 5 >] [I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p 1 . 1. 1 .1 0 .0 . 0. 0 e q 23 a n y eq 2 2 1 3 . 7 5 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t )  i c m p  I P A D D R  M A S K  a n y < 0 -2 5 5 > c o de  < 0 - 2 5 5 > [ I F N A M E] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p I P AD DR M A SK an y < 0 - 25 5 > c od e <0 - 25 5 > [ I FN A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd
GigaX2024B/M L2 Managed Switch CLI Manual 144 d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s A n y A n y d e st i na t io n ho s t < 0 - 2 55 > IC MP m es sa ge t y p e < 0 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p I P AD DR M A SK an y < 0 - 25 5 > c od e <0 - 25 5 > [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p 1 .1 . 1. 1 0. 0 .0 . 0 a n y 2 c o d e 3 1 3 . 7 6 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r mi t )  ( i p | t c p | u dp | i c m p )  an y  IP AD D R  MA S K  [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( i p | tc p | ud p |i c mp ) an y I P A D D R MA S K [ I FN A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol
GigaX2024B/M L2 Managed Switch CLI Manual 145 U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol A n y A n y S o ur c e h os t I P AD DR de st in at i on ad d r es s M A S K de st i na t i on wi l dc a r d b it s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( i p | tc p | ud p |i c mp ) an y I P A D D R MA S K [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p a ny 1. 1 . 1. 1 0 . 0. 0 . 0 1 3 . 7 7 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t ) ( t c p | u d p ) an y [ e q ] [ < 0 - 6 5 53 5 > ] I P A D D R M A S K  [ e q ]  [ < 0 - 65 5 3 5 > ]  [ I F N AM E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) a n y [e q] [< 0- 6 55 3 5> ] I P AD DR M AS K [ eq ] [ <0 - 65 5 35 > ] [I F NA ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l A n y A n y S o ur c e h os t e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e
GigaX2024B/M L2 Managed Switch CLI Manual 146 < 0 - 6 55 3 5 > Po rt n um b er I P AD DR de st in at i on ad d r es s M A S K de st i na t i on wi l dc a r d b it s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) a n y [e q] [< 0- 6 55 3 5> ] I P AD DR M AS K [ eq ] [ <0 - 65 5 35 > ] [I F NA ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p a n y e q 2 1 1 . 1. 1 .1 0 . 0 . 0. 0 eq 22 1 3 . 7 8 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t )  i c m p  a n y  IP A D D R  M A S K  < 0 -2 5 5 > c o de  < 0 - 2 5 5 > [ I F N A M E] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p a n y I P AD DR M A SK <0 - 25 5 > c o de <0 - 2 55 > [ I FN A M E] P a r a me t e rs A c c e ss - l is t A d d an a cc e ss li s t e n tr y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol
GigaX2024B/M L2 Managed Switch CLI Manual 147 A n y A n y S o ur c e h os t I P AD DR de st in at i on ad d r es s M A S K de st i na t i on wi l dc a r d b it s < 0 - 2 55 > IC MP m es sa ge t y p e < 0 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p an y I P AD DR M A SK <0 - 25 5 > c o de <0 - 2 55 > [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p a ny 1. 1 . 1. 1 0 . 0. 0 . 0 2 c o d e 3 1 3 . 7 9 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t ) (i p | t c p | u d p| i c m p ) a n y an y [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( i p | tc p | ud p |i c mp ) an y a n y [ I FN A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol A n y A n y S o ur c e h os t
GigaX2024B/M L2 Managed Switch CLI Manual 148 A n y A n y d e st i na t io n ho s t [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( i p | tc p | ud p |i c mp ) an y a n y [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p a ny an y 1 3 . 8 0 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t ) ( t c p | u dp ) a n y [ e q ] [ < 0 - 6 5 5 3 5 > ] a n y [ e q ] [ < 0 - 6 5 5 3 5 > ] [ I FN A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) a n y [e q ] [ < 0- 6 55 3 5 >] an y [ e q ] [ <0 - 65 5 3 5> ] [ I FN A M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l A n y A n y S o ur c e h os t e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er A n y A n y d e st i na t io n ho s t e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er
GigaX2024B/M L2 Managed Switch CLI Manual 149 [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on  gu r e t e rm i na l mo d e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) a n y [e q ] [ < 0- 6 55 3 5 >] an y [ e q ] [ <0 - 65 5 3 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p a n y e q 2 1 a n y e q 2 2 1 3 . 8 1 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) (d eny | p er mit ) ic m p an y an y <0- 255 > co de < 0- 255 > [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p a n y a n y <0 - 2 55 > c o de < 0- 2 55 > [ I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol A n y A n y S o ur c e h os t A n y A n y d e st i na t io n ho s t < 0 - 2 55 > IC MP m es sa ge t y p e < 0 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p an y a n y <0 - 2 55 > c o de < 0- 2 55 > [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e]
GigaX2024B/M L2 Managed Switch CLI Manual 150 D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p a ny an y 2 c od e 3 1 3 . 8 2 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( de n y| p er m it )  ( i p | tc p |u d p| i cm p ) I P A D D R  M A SK  h o st  I P A D D R [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( i p | tc p | ud p |i c mp ) IP AD DR M AS K h o st IP AD DR [ IF N AM E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR so ur ce ad d re s s M A S K so u rc e wi l dc a rd b it s . h o s t A s in gl e d e s ti n at i on h os t I P AD DR De st in a ti o n a d dr e ss [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( i p | tc p | ud p |i c mp ) IP AD DR M AS K h o st IP AD DR [I F NA M E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t
GigaX2024B/M L2 Managed Switch CLI Manual 151 D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p 1 .1 . 1. 1 0. 0 .0 . 0 h o st 1 . 1 . 1. 4 1 3 . 8 3 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t )  ( t c p | u d p )  I P A D D R  M A S K  [ e q ] [ < 0 - 6 5 5 3 5 > ] h o st I P A D D R [ e q ] [ < 0 - 65 5 3 5 > ] [ I F N AM E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) I P AD DR M A SK [e q ] [ < 0- 6 55 3 5> ] ho s t I P AD DR [ e q] [< 0 - 65 5 35 > ] [ I F N AM E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR so ur ce ad d re s s M A S K so u rc e wi l dc a rd b it s e q M a t c h o n l y p ac k et s on a g iv e n p o rt nu m b e < 0 - 6 55 3 5 > Po rt n um b er . h o s t A s in gl e d e st i na t i on ho s t I P AD DR De st in a ti o n a d dr e ss e q M a t c h o n l y p ac k et s on a g iv e n p o rt nu m b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) I P AD DR M A SK [e q ] [ < 0- 6 55 3 5> ] ho s t I P AD DR [ e q] [< 0 - 65 5 35 > ] [ I F N AM E ]
GigaX2024B/M L2 Managed Switch CLI Manual 152 S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t u d p 1 . 1. 1 .1 0 .0 . 0. 0 e q 21 h o s t 1 . 1 .1 . 4 e q 2 2 1 3 . 8 4 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) (d e n y | p e r m it )  i c m p  I P A D D R  M A S K  h o s t IP A D D R  < 0 - 2 5 5 > c o d e < 0- 2 5 5 > [ I F NA M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p I P AD DR M A SK ho s t I P A D D R <0 - 25 5 > c o de <0 - 25 5 > [ I FN A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR so ur ce a d dr e ss M A S K so u rc e wi l dc a rd b it s . h o s t A s in gl e d e s ti n at i on h os t I P AD DR De st in a ti o n a d dr e ss < 0 - 2 55 > IC MP m es sa ge t y p e < 0 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E g re s s i n te r fa c e n a me C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p I P AD DR M A SK ho s t I P A D D R <0 - 25 5 > c o de <0 - 25 5 > [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t
GigaX2024B/M L2 Managed Switch CLI Manual 153 D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p 1 .1 . 1. 1 0. 0 .0 . 0 h o st 1 . 1 . 1. 4 2 c od e 3 1 3 . 8 5 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t ) ( i p | t c p | u d p | i c m p ) h o s t I P A D D R I P A D D R  M A S K  [ I F N AM E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( i p | tc p | ud p |i c mp ) ho s t I P AD DR I P A D D R MA S K [ IF N AM E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. Ip - > An y In t er n et P ro t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s I P AD DR de st in at i on ad d r es s M A S K de st i na t i on wi l dc a r d b it s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( i p | tc p | ud p |i c mp ) ho s t I P AD DR I P A D D R MA S K [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or
GigaX2024B/M L2 Managed Switch CLI Manual 154 p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p h os t 1 . 1 .1 . 1 1 .1 . 1 .4 0 . 0 . 0. 0 1 3 . 8 6 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t ) ( t c p | u d p ) h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ] I P A D D R  M A S K  [ e q ] [ < 0 - 6 5 5 3 5 > ]  [ IF N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) h o s t I P A D D R [ eq ] [ < 0- 6 5 53 5 >] IP AD DR M AS K [ e q ] [ <0 - 65 5 3 5> ] [ I F N AM E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l . h o s t A s in gl e S o u rc e h o st I P AD DR So ur ce ad d re s s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er I P AD DR de st in at i on ad d r es s M A S K de st i na t i on wi l dc a r d b it s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) h o s t I P A D D R [ eq ] [ < 0- 6 5 53 5 >] IP AD DR M AS K [ e q ] [ <0 - 65 5 3 5> ] [ I F N AM E ]
GigaX2024B/M L2 Managed Switch CLI Manual 155 S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p h o st 1. 1 . 1. 1 e q 2 1 1 . 1 . 1. 4 0. 0 .0 . 0 e q 2 2 1 3 . 8 7 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) (d e n y | p e r m it )  i c m p  h o s t  I P A D D R  I P A D D R  M A S K  < 0 - 2 5 5 > c o d e < 0- 2 5 5 > [ I F NA M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p h o s t I P AD DR I P A D D R MA S K < 0- 2 5 5> co d e < 0 -2 5 5> [I F N AM E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol . h o s t A s in gl e S o u rc e h o st I P AD DR So ur ce ad d re s s I P AD DR de st in at i on ad d r es s M A S K de st i na t i on wi l dc a r d b it s < 0 - 2 55 > IC MP m es sa ge t y p e < 0 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p h o s t I P A D D R I P AD DR M AS K <0 - 25 5 > c o de <0 - 25 5 > [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t
GigaX2024B/M L2 Managed Switch CLI Manual 156 D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p h os t 1 . 1 .1 . 1 1 .1 . 1 .4 0 . 0 . 0. 0 2 c od e 3 1 3 . 8 8 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) (de ny| per mit ) (ip| tcp |u dp| icm p) hos t IP ADDR host I P A D D R [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( i p | tc p | ud p |i c mp ) ho s t I P AD DR h o st IP AD DR [ IF N AM E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s . h o s t A s in g l e d es t in a t io n h o st I P AD DR De st in a ti o n a d dr e ss [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( i p | tc p | ud p |i c mp ) ho s t I P AD DR h o st IP AD DR [ IF N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or
GigaX2024B/M L2 Managed Switch CLI Manual 157 p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p h os t 1 . 1 .1 . 1 h os t 1 . 1 . 1. 4 1 3 . 8 9 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t ) ( t c p | u d p ) h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ] h o s t I P A D D R [ e q ] [ < 0 - 6 5 53 5 > ] [ I F N AM E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) h o s t I P A D D R [ eq ] [ < 0- 6 5 53 5 >] ho s t I P A D D R [e q ] [ < 0- 6 55 3 5> ] [ I F N AM E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er . h o s t A s in g l e d es t in a t io n h o st I P AD DR De st in a ti o n a d dr e ss e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) h o s t I P A D D R [ eq ] [ < 0- 6 5 53 5 >] ho s t I P A D D R [e q ] [ < 0- 6 55 3 5> ] [ I F N AM E ]
GigaX2024B/M L2 Managed Switch CLI Manual 158 S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p h os t 1 . 1 .1 . 1 e q 2 1 h o s t 1 . 1 .1 . 4 e q 2 1 1 3 . 9 0 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t ) i c m p h o s t I P A D D R h o s t I P A D D R < 0 - 2 5 5 > c o d e < 0- 2 5 5 > [ I F NA M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p h o s t I P AD DR h o st IP AD DR < 0- 2 55 > c o d e < 0- 2 55 > [I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol . h o s t A s in gl e S o u rc e h o st I P AD DR So ur ce ad d re s s h o s t A s in gl e d e s ti n at i on h os t I P AD DR De st in a ti o n a d dr e ss < 0 - 2 55 > IC MP m es sa ge t y p e < 0 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p h o s t I P A D D R h os t I P A D D R <0 - 2 55 > c o de < 0- 2 55 > [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t
GigaX2024B/M L2 Managed Switch CLI Manual 159 D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p h os t 1 . 1 .1 . 1 h os t 1 . 1 . 1. 4 3 c od e 3 1 3 . 9 1 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) (deny |per mit) (i p|tcp |udp| icmp) any host IP ADDR [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( i p | tc p | ud p |i c mp ) an y h o st I P AD DR [ IF N A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol A n y A n y S o ur c e h os t . h o s t A s in g l e d es t in a t io n h o st I P AD DR De st in a ti o n a d dr e ss [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( i p | tc p | ud p |i c mp ) an y h o st I P AD DR [ IF N A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d .
GigaX2024B/M L2 Managed Switch CLI Manual 160 E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p a ny ho s t 1 . 1. 1 .1 1 3 . 9 2 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) (deny|permit) (tcp|udp) any [eq] [<0-65535>] host I P A D D R [ e q ] [ < 0 - 65 5 3 5 > ] [ I F N AM E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) a n y [e q ] [ < 0- 6 55 3 5 >] ho s t I P A D D R [e q ] [ <0 - 6 55 3 5> ] [ I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l A n y A n y S o ur c e h os t e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er . h o s t A s in g l e d es t in a t io n h o st I P AD DR De st in a ti o n a d dr e ss e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) a n y [e q ] [ < 0- 6 55 3 5 >] ho s t I P A D D R [e q ] [ <0 - 6 55 3 5> ] [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d .
GigaX2024B/M L2 Managed Switch CLI Manual 161 E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p a n y e q 2 1 h o st 1. 1 . 1. 1 e q 2 2 1 3 . 9 3 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d en y | pe rm i t ) i c mp a n y h o st I P A D D R <0 - 2 5 5> c o de < 0 - 2 5 5 > [ I F N A M E] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p a n y h o s t I P A D D R < 0- 2 55 > c o d e < 0- 2 55 > [I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol A n y A n y S o ur c e h os t . h o s t A s in g l e d es t in a t io n h o st I P AD DR De st in a ti o n a d dr e ss < 0 - 2 55 > IC MP m es sa ge t y p e < 0 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p an y h o s t I P A D D R < 0- 2 55 > c o d e < 0- 2 55 > [I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p a ny ho s t 1 . 1. 1 .1 2 c o d e 3
GigaX2024B/M L2 Managed Switch CLI Manual 162 1 3 . 9 4 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) (deny |per mit) (i p|tcp |udp| icmp) host IP AD DR any [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( i p | tc p | ud p |i c mp ) ho s t I P AD DR a n y [ IF N A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I p - > An y I n t er n et Pr o t oc o l T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s A n y A n y d e st i na t io n ho s t [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( i p | tc p | ud p |i c mp ) ho s t I P AD DR a n y [ IF N A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p h os t 1 . 1 .1 . 1 a ny
GigaX2024B/M L2 Managed Switch CLI Manual 163 1 3 . 9 5 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t ) ( t c p | u d p ) h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ] a n y [ e q ] [ < 0 - 6 55 3 5 > ] [ I F NA M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) h o s t I P A D D R [ eq ] [ < 0- 6 5 53 5 >] an y [e q ] [ <0 - 6 55 3 5> ] [ I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er A n y A n y d e st i na t io n ho s t e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) h o s t I P A D D R [ eq ] [ < 0- 6 5 53 5 >] an y [e q ] [ <0 - 6 55 3 5> ] [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p h o st 1. 1 . 1. 1 e q 2 1 an y e q 2 1
GigaX2024B/M L2 Managed Switch CLI Manual 164 1 3 . 9 6 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d en y | pe rm i t ) i c mp h o st I P A D D R an y <0 - 2 5 5> c o de < 0 - 2 5 5 > [ I F N A M E] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p h o s t I P AD DR a n y < 0- 2 55 > co d e < 0- 2 5 5> [I F NA M E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s A n y A n y d e st i na t io n ho s t < 0 - 2 55 > IC MP m es sa ge t y p e < 0 - 2 55 > IC MP m es sa ge c o d e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p h o s t I P A D D R a ny <0 - 25 5 > c o de <0 - 2 55 > [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p h os t 1 . 1 .1 . 1 a ny 2 c o d e 2
GigaX2024B/M L2 Managed Switch CLI Manual 165 1 3 . 9 7 a c c e s s - l i s t ( < 1 - 9 9 > | < 1 3 0 0 - 1 9 9 9 > ) ( d e n y | p e r m i t ) IP A D D R [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 1- 9 9 >| < 13 0 0- 1 9 99 > ) ( de n y |p e rm i t) I P AD DR [ I F N AM E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 - 9 9> S t a n da r d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > St an d a rd IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I P AD DR So ur ce ad d re s s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 -9 9 >| < 13 0 0 -1 9 99 > ) ( d en y |p e rm i t ) I P AD DR [ I F N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 88 p er m it 10 . 0 .0 . 1 1 3 . 9 8 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t )  ( t c p | u d p )  I P A D D R  M A S K  I P A D D R  M A S K  e q  < 0 - 6 5 5 35 >  [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) I P AD DR A .B . C .D IP AD DR A .B . C. D e q < 0 - 65 5 35 > [ I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e)
GigaX2024B/M L2 Managed Switch CLI Manual 166 p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s I P AD DR De st in at i on ad d r es s M A S K De st i na t i on wi l dc a r d b it s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) I P AD DR M A SK IP AD DR M AS K e q < 0 - 65 5 35 > [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p 1 . 1. 1 .1 0 .0 . 0. 0 1 . 1 .1 . 4 0 . 0 . 0. 0 eq 21 1 3 . 9 9 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t )  ( t c p | u d p )  I P A D D R  M A S K  [ e q ] [ < 0 - 6 5 5 3 5 > ]  I P A D D R  M A S K  [ IF N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) I P AD DR M A SK [e q ] [ < 0- 6 55 3 5> ] IP AD DR M AS K [ I FN A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd
GigaX2024B/M L2 Managed Switch CLI Manual 167 d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er I P AD DR De st in at i on ad d r es s M A S K De st i na t i on wi l dc a r d b it s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) I P AD DR M A SK [e q ] [ < 0- 6 55 3 5> ] IP AD DR M AS K [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p 1 . 1. 1 .1 0 .0 . 0. 0 e q 21 1 . 1 . 1. 4 0. 0 .0 . 0 1 3 . 1 0 0 ac c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t )  ( t c p | u d p )  I P A D D R  M A S K  a n y  [ e q ] [ < 0 - 6 5 5 3 5 > ] [ I FN A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) I P AD DR M A SK an y [ e q ] [ <0 - 65 5 3 5> ] [ I FN A M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t.
GigaX2024B/M L2 Managed Switch CLI Manual 168 T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s A n y A n y d e st i na t io n ho s t e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) I P AD DR M A SK an y [ e q ] [ <0 - 65 5 3 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p 1 . 1. 1 .1 0 .0 . 0. 0 a n y e q 2 1 1 3 . 1 0 1 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) ( d e n y | p e r m i t )  ( t c p | u d p )  I P A D D R  M A S K  [ e q ] [ < 0 - 6 5 5 3 5 > ] a n y [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) I P AD DR A .B . C .D [e q ] [ < 0- 6 55 3 5> ] an y [ I FN A M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l
GigaX2024B/M L2 Managed Switch CLI Manual 169 I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er A n y A n y d e st i na t io n ho s t [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) I P AD DR M A SK [e q ] [ < 0- 6 55 3 5> ] an y [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p 1 . 1. 1 .1 0 .0 . 0. 0 e q 21 a n y 1 3 . 1 0 2 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) ( d e n y | p e r m i t )  ( t c p | u d p )  I P A D D R  M A S K  [ e q ] [ < 0 - 6 5 5 3 5 > ] h o st I P A D D R [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) I P AD DR M A SK [e q ] [ < 0- 6 55 3 5> ] ho s t I P AD DR [ I FN A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR so ur ce ad d re s s M A S K so u rc e wi l dc a rd b it s
GigaX2024B/M L2 Managed Switch CLI Manual 170 e q M a t c h o n l y p ac k et s on a g iv e n p o rt nu m b e < 0 - 6 55 3 5 > Po rt n um b er . h o s t A s in gl e d e st i na t i on ho s t I P AD DR De st in a ti o n a d dr e ss [ I F NA M E ] E gr es s i n t er f ac e n a m e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) I P AD DR M A SK [e q ] [ < 0- 6 55 3 5> ] ho s t I P AD DR [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p 1 . 1. 1 .1 0 .0 . 0. 0 e q 21 h o s t 1 . 1 .1 . 4 1 3 . 1 0 3 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) ( d e n y | p e r m i t )  ( tc p | u d p )  IP A D D R  M A S K  h o s t  I P A D D R  [ e q ] [ < 0 - 6 5 5 3 5 >] [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) I P AD DR M A SK ho s t I P A D D R [e q ] [ <0 - 6 55 3 5> ] [ I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l I P AD DR so ur ce ad d re s s M A S K so u rc e wi l dc a rd b it s . h o s t A s in gl e d e s ti n at i on h os t
GigaX2024B/M L2 Managed Switch CLI Manual 171 I P AD DR De st in a ti o n a d dr e ss e q M a t c h o n l y p ac k et s on a g iv e n p o rt nu m b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) I P AD DR M A SK ho s t I P A D D R [e q ] [ <0 - 6 55 3 5> ] [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p 1 . 1. 1 .1 0 .0 . 0. 0 h o s t 1 . 1 . 1. 4 eq 21 1 3 . 1 0 4 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) ( d e n y | p e r m i t )  ( t c p | u d p )  a n y  I P AD D R  M A S K  [ e q ]  [ < 0 - 6 5 5 3 5 > ] [ I FN A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) a n y IP AD DR M AS K [ e q ] [ <0 - 65 5 3 5> ] [ I FN A M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l A n y A n y S o ur c e h os t I P AD DR de st in at i on ad d r es s M A S K de st i na t i on wi l dc a r d b it s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e
GigaX2024B/M L2 Managed Switch CLI Manual 172 < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) a n y IP AD DR M AS K [ e q ] [ <0 - 65 5 3 5> ] [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p a n y 1 .1 . 1 .1 0. 0 .0 . 0 e q 2 1 1 3 . 1 0 5 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) (d en y| pe r mi t) (t cp |u d p) an y a ny [ eq ] [ <0 -6 55 3 5> ] [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) a n y an y [e q ] [ <0 - 6 55 3 5> ] [ I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l A n y A n y S o ur c e h os t A n y A n y d e st i na t io n ho s t e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e
GigaX2024B/M L2 Managed Switch CLI Manual 173 N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) a n y an y [e q ] [ <0 - 6 55 3 5> ] [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p a n y a ny e q 2 1 1 3 . 1 0 6 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) (d en y| pe r mi t) (t cp |u d p) an y [ eq ] [< 0- 65 53 5 >] an y [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) a n y [e q ] [ < 0- 6 55 3 5 >] an y [ I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l A n y A n y S o ur c e h os t e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er A n y A n y d e st i na t io n ho s t [ I F NA M E ] E gr es s i n t er f ac e n a m e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) a n y [e q ] [ < 0- 6 55 3 5 >] an y [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t
GigaX2024B/M L2 Managed Switch CLI Manual 174 D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p a n y e q 2 1 a n y 1 3 . 1 0 7 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) ( d e n y | p e r m i t ) ( t c p | u d p ) an y [ e q ] [ < 0 - 6 5 53 5 > ] I P A D D R M A S K  [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) a n y [e q ] [ < 0- 6 55 3 5 >] IP AD DR A .B . C. D [ I FN A M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l A n y A n y S o ur c e h os t e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er I P AD DR de st in at i on ad d r es s M A S K de st i na t i on wi l dc a r d b it s [ I F NA M E ] E gr es s i n t er f ac e n a m e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) a n y [e q ] [ < 0- 6 55 3 5 >] IP AD DR M AS K [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d .
GigaX2024B/M L2 Managed Switch CLI Manual 175 E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p a n y e q 2 1 1 0 .0 . 0. 1 0 . 0 . 0. 0 1 3 . 1 0 8 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) (deny|permit) (tcp|udp) any [eq] [<0-65535>] host I P A D D R [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) a n y [e q ] [ < 0- 6 55 3 5 >] ho s t I P A D D R [I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l A n y A n y S o ur c e h os t e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er h o s t A s in gl e d e s ti n at i on h os t I P AD DR De st in at i on ad d r es s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) a n y [e q ] [ < 0- 6 55 3 5 >] ho s t I P A D D R [I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p a n y e q 2 1 h o st 10 . 0 .0 . 1
GigaX2024B/M L2 Managed Switch CLI Manual 176 1 3 . 1 0 9 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) ( d e n y | p e r m i t ) ( t c p | u d p ) a n y h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ] [ I FN A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) a n y ho s t I P A D D R [e q ] [ < 0- 6 55 3 5> ] [I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l A n y A n y S o ur c e h os t . h o s t A s in g l e d es t in a t io n h o st I P AD DR De st in a ti o n a d dr e ss e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) a n y ho s t I P A D D R [e q ] [ < 0- 6 55 3 5> ] [I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p a n y h os t 10 . 0. 0 .1 e q 2 1
GigaX2024B/M L2 Managed Switch CLI Manual 177 1 3 . 1 1 0 ac c es s- l is t (<1 0 0- 1 99 >| < 20 0 0- 26 9 9> ) ( d e n y | p e r m i t )  ( tc p | u d p )  ho s t I P A DD R  I P A D D R MA S K  [ e q ] [ < 0 - 6 5 5 3 5 >] [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) h o s t I P A D D R I P AD DR M AS K [e q ] [ <0 - 6 55 3 5> ] [ I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s I P AD DR de st in at i on ad d r es s M A S K de st i na t i on wi l dc a r d b it s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) h o s t I P A D D R I P AD DR M AS K [e q ] [ <0 - 6 55 3 5> ] [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p h o st 10 . 0 .0 . 1 1 0. 0 . 0. 4 0 . 0 . 0. 0 eq 21
GigaX2024B/M L2 Managed Switch CLI Manual 178 1 3 . 1 1 1 a c c e s s - l i s t ( < 1 0 0 - 1 9 9 > | < 2 0 0 0 - 2 6 9 9 > ) ( d e n y | p e r m i t ) ( t c p | u d p ) h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ] I P A D D R  M A S K  [ I F N AM E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) h o s t I P A D D R [ eq ] [ < 0- 6 5 53 5 >] IP AD DR M AS K [ I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l . h o s t A s in gl e S o u rc e h o st I P AD DR So ur ce ad d re s s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er I P AD DR de st in at i on ad d r es s M A S K de st i na t i on wi l dc a r d b it s [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) h o s t I P A D D R [ eq ] [ < 0- 6 5 53 5 >] IP AD DR M AS K [ I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p h o st 10 . 0 .0 . 1 e q 2 1 1 0 . 0 .0 . 4 0 . 0. 0 .0
GigaX2024B/M L2 Managed Switch CLI Manual 179 1 3 . 1 1 2 ac c es s- l is t (<1 0 0- 1 99 >| < 20 0 0- 26 9 9> ) ( d e n y | p e r m i t ) ( t c p | u d p ) h o s t I P A D D R a n y [ e q ] [ < 0 - 6 5 5 3 5 > ] [ I FN A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) h o s t I P A D D R a ny [e q ] [ < 0- 6 55 3 5> ] [I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s A n y A n y d e st i na t io n ho s t e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) h o s t I P A D D R a ny [e q ] [ < 0- 6 55 3 5> ] [I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p h o st 10 . 0 .0 . 1 a ny e q 2 1
GigaX2024B/M L2 Managed Switch CLI Manual 180 1 3 . 1 1 3 ac c es s- l is t (<1 0 0- 1 99 >| < 20 0 0- 26 9 9> ) ( d e n y | p e r m i t ) ( t c p | u d p ) h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ] a n y [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) h o s t I P A D D R [ eq ] [ < 0- 6 5 53 5 >] an y [I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er A n y A n y d e st i na t io n ho s t [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) h o s t I P A D D R [ eq ] [ < 0- 6 5 53 5 >] an y [I F NA M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t P a s s D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p h o st 10 . 0 .0 . 1 e q 2 1 a n y
GigaX2024B/M L2 Managed Switch CLI Manual 181 1 3 . 1 1 4 ac c es s- l is t (<1 0 0- 1 99 >| < 20 0 0- 26 9 9> ) ( d e n y | p e r m i t ) ( t c p | u d p ) h o s t I P A D D R [ e q ] [ < 0 - 6 5 5 3 5 > ] h o s t I P A D D R [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) h o s t I P A D D R [ eq ] [ < 0- 6 5 53 5 >] ho s t I P A D D R [I F NA M E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er . h o s t A s in g l e d es t in a t io n h o st I P AD DR De st in a ti o n a d dr e ss [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) h o s t I P A D D R [ eq ] [ < 0- 6 5 53 5 >] ho s t I P A D D R [I F NA M E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p h o st 10 . 0 .0 . 1 e q 2 1 h o s t 1 0 . 0. 0 .4
GigaX2024B/M L2 Managed Switch CLI Manual 182 1 3 . 1 1 5 ac c es s- l is t (<1 0 0- 1 99 >| < 20 0 0- 26 9 9> ) (d en y |p er m it ) (t cp | u dp ) ho st IP AD D R ho st IP AD D R [ e q ] [ < 0 - 6 5 5 3 5 >] [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) ( tc p |u d p ) h o s t I P A D D R h os t I P A D D R [e q ] [ < 0- 6 55 3 5 >] [I F NA M E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. T c p - > T r a n sm i ss i o n C on t ro l Pr o to c ol U d p - > Us er D a t ag r am Pr o t oc o l . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s . h o s t A s in g l e d es t in a t io n h o st I P AD DR De st in a ti o n a d dr e ss e q Ma t ch on l y p a ck e ts o n a g i ve n po r t n um b e < 0 - 6 55 3 5 > Po rt n um b er [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) ( tc p | ud p ) h o s t I P A D D R h os t I P A D D R [e q ] [ < 0- 6 55 3 5 >] [I F NA M E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t t c p h o st 10 . 0 .0 . 1 h os t 1 0 . 0 .0 . 4 e q 2 1
GigaX2024B/M L2 Managed Switch CLI Manual 183 1 3 . 1 1 6 ac c es s- l is t (<1 0 0- 1 99 >| < 20 0 0- 26 9 9> ) (d en y| pe rm it ) icmp  IP ADD R MA SK  IP ADDR  MAS K  < 0 - 2 5 5 > [ I F N A M E] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p I P AD DR M A SK IP AD DR M AS K < 0 -2 5 5 > [ IF N AM E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s I P AD DR De st in at i on ad d r es s M A S K De st i na t i on wi l dc a r d b it s < 0 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p I P AD DR M A SK IP AD DR M AS K < 0 -2 5 5 > [ IF N AM E ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p 1 0. 0 .0 . 1 0 . 0. 0 .0 1 0 . 0 .0 . 4 0 . 0. 0 .0 1
GigaX2024B/M L2 Managed Switch CLI Manual 184 1 3 . 1 1 7 ac c es s- l is t (<1 0 0- 1 99 >| < 20 0 0- 26 9 9> ) ( d e n y | p e r m i t )  i c m p  I P A D D R  M A S K  a n y  < 0 - 2 5 5 >  [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p I P AD DR M A SK an y < 0 - 25 5 > [ IF N A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR So ur ce a d dr e ss M A S K So ur c e w i ld c ar d b i t s A n y A n y d e st i na t io n ho s t < 0 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p I P AD DR M A SK an y < 0 - 25 5 > [ IF N A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p 1 0. 0 .0 . 1 0 . 0. 0 .0 a ny 1 1 3 . 1 1 8 ac c es s- l is t (<1 0 0- 1 99 >| < 20 0 0- 26 9 9> ) ( d e n y | p e r m i t ) ic m p a n y a ny < 0 - 2 5 5 > [ IF N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p a n y a n y <0 - 2 55 > [ I FN A M E]
GigaX2024B/M L2 Managed Switch CLI Manual 185 P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol A n y A n y S o ur c e h os t A n y A n y d e st i na t io n ho s t < 0 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p an y a n y <0 - 2 55 > [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p a ny an y 1 1 3 . 1 1 9 ac c es s- l is t (<1 0 0- 1 99 >| < 20 0 0- 26 9 9> ) (d e n y | p e r m it )  i c m p  I P A D D R  M A S K  h o s t IP A D D R  < 0 - 2 5 5 > [ I F N A M E] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p I P AD DR M A SK ho s t I P A D D R <0 - 25 5 > [ I FN A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t.
GigaX2024B/M L2 Managed Switch CLI Manual 186 I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol I P AD DR so ur ce ad d re s s M A S K so u rc e wi l dc a rd b it s . h o s t A s in g l e d es t in a t io n h o st I P AD DR De st in a ti o n a d dr e ss < 0 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p I P AD DR M A SK ho s t I P A D D R <0 - 25 5 > [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p 1 0. 0 .0 . 1 0 . 0. 0 .0 h os t 1 0 . 0 .0 . 4 1 1 3 . 1 2 0 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) (d e n y | p e r m it )  i c m p  h o s t  I P A D D R  I P A D D R  M A S K  < 0 - 2 5 5 > [ I F N A M E] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p h o s t I P AD DR I P A D D R MA S K < 0- 2 5 5> [I F NA M E ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s
GigaX2024B/M L2 Managed Switch CLI Manual 187 I P AD DR de st in at i on ad d r es s M A S K de st i na t i on wi l dc a r d b it s < 0 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p h o s t I P A D D R I P AD DR M AS K <0 - 25 5 > [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p h os t 1 0 . 0. 0 .1 10 . 0 .0 . 4 0 . 0 . 0. 0 1 1 3 . 1 2 1 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) ( d e n y | p e r m i t ) i c m p h o s t I P A D D R h o s t I P A D D R < 0 - 2 5 5 > [ I F N A M E] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p h o s t I P AD DR h o st IP AD DR < 0- 2 55 > [ I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s . h o s t A s in g l e d es t in a t io n h o st I P AD DR De st in a ti o n a d dr e ss < 0 - 2 55 > IC MP m es sa ge t y p e
GigaX2024B/M L2 Managed Switch CLI Manual 188 [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p h o s t I P A D D R h os t I P A D D R <0 - 2 55 > [ I FN A M E] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p h os t 1 0 . 0. 0 .1 h os t 1 0 . 0 .0 . 4 1 1 3 . 1 2 2 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) ( d e n y | p e r m i t ) i c m p a n y h o s t I P A D D R < 0 - 2 5 5 > [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p a n y h o s t I P A D D R < 0- 2 55 > [ I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol A n y A n y S o ur c e h os t . h o s t A s in g l e d es t in a t io n h o st I P AD DR De st in a ti o n a d dr e ss < 0 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p an y h o s t I P A D D R < 0- 2 55 > [ I F NA M E]
GigaX2024B/M L2 Managed Switch CLI Manual 189 S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p a ny ho s t 1 0 .0 . 0. 1 1 1 3 . 1 2 3 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) ( d e n y | p e r m i t ) i c m p h o s t I P A D D R a n y < 0 - 2 5 5 > [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p h o s t I P AD DR a n y < 0- 2 55 > [I F NA M E] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol . h o s t A s in g l e S ou r ce h os t I P AD DR So ur ce ad d re s s A n y A n y d e st i na t io n ho s t < 0 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p h o s t I P A D D R a ny <0 - 25 5 > [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p h os t 1 0 . 0. 0 .1 an y 1
GigaX2024B/M L2 Managed Switch CLI Manual 190 1 3 . 1 2 4 acc e ss -l i st ( <1 0 0- 19 9 >| <2 0 00 - 26 99 > ) ( d e n y | p e r m i t )  i c m p  a n y  I P A D D R  M A S K  < 0 - 2 5 5 >  [ I F N A M E ] S y n t ax a c c e ss - l is t ( < 10 0 - 19 9 >| < 20 0 0 -2 6 99 > ) ( d en y |p e rm i t ) i cm p a n y I P AD DR M A SK <0 - 25 5 > [ I FN A ME ] P a r a me t e rs A c c e ss - l is t Ad d an ac c es s li s t e nt r y < 1 0 0 -1 9 9 > E x t e nd e d I P a c c e ss - li s t n u mb e r < 2 0 0 0- 2 6 99 > Ex te n d ed IP a cc es s- l is t n u mb e r ( e xp a nd e d r a n g e) p e r m it - > S p e c if y pa c ke t s t o f o rw a rd d e n y -> S p e c if y pa c ke t s t o r e je c t. I c m p -> In te r ne t C o nt r o l M es s ag e Pr o to c ol A n y A n y S o ur c e h os t I P AD DR de st in at i on ad d r es s M A S K de st i na t i on wi l dc a r d b it s < 0 - 2 55 > IC MP m es sa ge t y p e [ I F N AM E ] E gr es s i nt e rf a c e n am e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o a cc e s s- l is t ( < 1 00 - 19 9 >| < 2 00 0 -2 6 99 > ) ( d en y |p e r mi t ) i cm p an y I P AD DR M A SK <0 - 25 5 > [ I FN A ME ] S h o w S h o w a c c es - li s ts [ nu m be r |n a m e] D e f a ul t D e s c ri p t io n T h i s c o m ma n d s pe c i fy on e o r mo r e c on d i ti o ns de n i ed or p e r m it t e d t o d ec i d e i f t he p ac k et is f or w ar d ed o r d ro p pe d . E x a m pl e s A S U S (c o n g ) #a c ce s s -l i st 10 0 pe r mi t i c m p a ny 10 . 0 .0 . 1 0 .0 . 0 .0 1 14. Port Security
GigaX2024B/M L2 Managed Switch CLI Manual 191 1 4 . 1 s h o w po r t - s e c u r it y S y n t ax s h o w p o r t- s ec u ri t y P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w p o rt - se c u ri t y s ta t u s. E x a m pl e s A S U S # s h ow po r t- s e cu r it y 1 4 . 2 s h o w po r t - s e c u r it y a d d r e s s [I F N A M E ] S y n t ax s h o w p o r t- s ec u ri t y a d dr e ss [ IF N AM E ] P a r a me t e rs [ I F N AM E ] In te rf ac e ’s na m e , e x: fa s t et h er n et 1 / 0/ 1 o r g i g a bi t e th e rn e t1 / 0 /2 6 C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w s e cu r e a d dr e ss e s o f t h e p or t . E x a m pl e s A S U S # s h ow po r t- s e cu r it y a d d re s s f a1 / 0 /1 1 4 . 3  s h o w  po r t - s e c u r it y  i n t e r f a c e [ I F N A M E ] S y n t ax s h o w p o r t- s ec u ri t y i n te r fa c e [ I FN A ME ] P a r a me t e rs [ I F N AM E ] In te rf ac e ’s na m e , e x: fa s t et h er n et 1 / 0/ 1 o r g i g a bi t e th e rn e t1 / 0 /2 6 C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w p o rt - se c u ri t y s ta t u s o f t he p or t . E x a m pl e s A S U S # s h ow po r t- s e cu r it y i n t er f ac e f a 1 /0 / 1 1 4 . 4 s w i t c h p o r t - s e c ur i t y S y n t ax s w i t ch p or t -s e cu r i ty P a r a me t e rs
GigaX2024B/M L2 Managed Switch CLI Manual 192 C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o s wi t c h p or t -s e c ur i ty D e f a ul t D i s a bl e po r t s ec u r it y D e s c ri p t io n T o e n a b le po r t- s e cu r it y o f th e p o rt . E x a m pl e s A S U S (c o n g - if ) # s w it c h p or t - se c ur i ty 1 4 . 5 s w i t c h p o r t - s e c ur i t y a g i n g - ti m e < 0 - 1 4 40 > S y n t ax s w i t ch p or t -s e cu r i ty ag i ng - t im e < 0 -1 4 4 0> P a r a me t e rs < 0 - 1 44 0 > ag in g t im e , 0 me a ns n o a ge . C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o s wi t c h p or t -s e c ur i ty ag i n g- t im e D e f a ul t A g i n g t i me is 0. D e s c ri p t io n T o e n a b le po r t- s e cu r it y a g i ng of th e po r t. E x a m pl e s A S U S (c o n g - if ) # s w it c h p or t - se c ur i ty a gi n g- t im e 5 1 4 . 6 s w i t c h p o r t - s e c u r i t y a g i n g - t y p e ( a b s o l u t e | i n a c ti v i t y ) S y n t ax s w i t ch p or t -s e cu r i ty ag i ng - t yp e ( a bs o l ut e |i n ac t i vi t y) P a r a me t e rs A b s o lu t e Ab s ol u te ag i n g ( de f au l t ) I n a c ti v i ty Ag in g ba s ed on i na c ti v it y ti m e p er i o d C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o s wi t c h p or t -s e c ur i ty ag i n g t yp e D e f a ul t A b s o lu t e a g in g D e s c ri p t io n T o s e l e ct po r t- s e cu r it y a g i ng ty p e o f t h e p or t . E x a m pl e s A S U S (c o n g - if ) # s w it c h p or t - se c ur i ty a gi n g- t yp e in a ct i vi t y 1 4 . 7 s w i t c h p o r t - s e c ur i t y m a c - a d dr e s s M A C A DD R S y n t ax s w i t ch p or t -s e cu r i ty ma c -a d d re s s M AC A D DR P a r a me t e rs M A C A DD R M A C ad d r es s x x xx . x xx x .x x xx
GigaX2024B/M L2 Managed Switch CLI Manual 193 C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o s wi t c h p or t -s e c ur i ty ma c - ad d re s s M A CA D DR D e f a ul t D e s c ri p t io n T o c o n  gu r e s ec u r e m ac of t he po r t. E x a m pl e s A S U S (c o n g - if ) # s w it c h p or t - se c ur i ty m ac - ad d re s s 0 0 1 1. 22 22 .3 3 44 1 4 . 8  s w i t c h p o r t - s e c ur i t y  m a x i m u n < 1 - 1 3 2 > S y n t ax s w i t ch p or t -s e cu r i ty ma x im u n < 1 -1 3 2> P a r a me t e rs < 1 - 1 32 > Nu mb er of ad d re s s es (d e fa u l t i s 1 ). C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o s wi t c h p or t -s e c ur i ty sw i t ch po r t- s e cu r it y m a x im u n D e f a ul t D e f a ul t is 1 D e s c ri p t io n T o c o n  gu r e m ax i m un se c ur e ma c a d dr e s se s o f t h e p o rt . E x a m pl e s A S U S (c o n g - if ) # s w it c h p or t - se c ur i ty m ax i mu m 5 1 4 . 9 s w i t c h p o r t - s e c ur i t y r e u p S y n t ax s w i t ch p or t -s e cu r i ty re u p P a r a me t e rs C o m m an d Mo d e I nt er fa c e m o de N o / c le a r D e f a ul t D e s c ri p t io n T o r e u p t h e p or t wh e n i t w a s s hu t do w n b y p o rt s ec u ri t y E x a m pl e s A S U S (c o n g - if ) # s w it c h p or t - se c ur i ty r eu p 1 4 . 1 0 sw i t c h p o r t- s e c u r i t y s h u t d o w n < 1 0- 1 4 4 0 > S y n t ax s w i t ch p or t -s e cu r i ty sh u td o w n < 10 - 14 4 0 > P a r a me t e rs < 1 0 - 14 4 0 > I n t e rf a c e m ax i mu m sh u td o wn t im e C o m m an d Mo d e I nt er fa c e m o de
GigaX2024B/M L2 Managed Switch CLI Manual 194 N o / c le a r N o s wi t c h p or t -s e c ur i ty sh u t do w n D e f a ul t D e s c ri p t io n T o c o n  gu r e m ax i m um sh u td o w n t im e E x a m pl e s A S U S (c o n g - if ) # s w it c h p or t - se c ur i ty s hu t do w n 3 0 1 4 . 1 1 s w i t c h p o r t - s e c u ri t y vi o l a t i o n ( p r ot e c t | r e s t r i ct | s h u t d o w n ) S y n t ax s w i t ch p or t -s e cu r i ty vi o la t i on (p r ot e c t| r es t ri c t |s h ut d ow n ) P a r a me t e rs p r o t ec t P r o t e ct mo d e , d ro p p a c ke t s w he n se c ur i ty v i o l at i o n o cc u rs r e s t ri c t Re st ri c t m o de , n o t if y u s er w he n s e cu r i ty v i o l at i o n o cc u rs s h u t do w n Sh ut d o wn mo d e, s hu t do w n t h is po r t w h en s e c u ri t y v i ol a ti o n o c cu r s ( d ef a ul t ) C o m m an d Mo d e I nt er fa c e m o de N o / c le a r N o s wi t c h p or t -s e c ur i ty vi o l at i on D e f a ul t S h u t do w n m o de D e s c ri p t io n T o c o n  gu r e p or t se c ur i ty v io l at i on m od e E x a m pl e s A S U S (c o n g - if ) # s w it c h p or t - se c ur i ty v io l at i on r es t ri c t 15. Interfaceconguration: 1 5 . 1  i n g r e ss   l t e r  ( en a b l e | d i s a b le ) S y n t ax i n g r es s l t er (e n a bl e |d i sa b l e) P a r a me t e rs  l t e ri n g  l t e r i ng ru l es d i s a bl e -> di sa b le s 80 2 .1 Q i n g re s s  lt e r in g f e at u r e e n a b le - > en a b le s 8 0 2. 1 Q i n gr e ss  lt e ri n g f e at u re C o m m an d Mo d e I nt er fa c e m o de
GigaX2024B/M L2 Managed Switch CLI Manual 195 N o / c le a r S h o w s h o w i n g re s s  lt e r in g I F NA M E D e f a ul t T h e de f a ul t i s d i s ab l e D e s c ri p t io n T h i s c o m ma n d s et s th e 8 0 2. 1 Q i n gr e ss  lt e ri n g f e at u re s E x a m pl e s A S U S (c o n g - if ) #i n g re s s  lt e r e n ab l e 1 5 . 2  s h o w  in g r e s s   l te r  I F N A M E S y n t ax s h o w i n g re s s  lt e r I F NA M E P a r a me t e rs [ I F N AM E ] In te rf ac e ’s na m e , e x: fa s t et h er n et 1 / 0/ 1 o r g i g a bi t e th e rn e t1 / 0 /2 6 C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w i n gr e ss  lt e ri n g I F NA M E s ta t u s. E x a m pl e s A S U S # s h ow in g re s s  l te r f a 1 /0 / 1 1 5 . 3 i p a c c e s s - g r o u p ( < 1 - 1 9 9 > | < 1 3 0 0 - 2 6 9 9 > | W OR D )  i n S y n t ax i p a cc e s s- g ro u p ( < 1- 1 99 > | < 1 30 0 -2 6 99 > | WO R D) in P a r a me t e rs < 1 - 1 99 > < 13 0 0- 2 69 9 > |w or d l t er id o r n am e C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o i p a c ce s s- g ro u p S h o w s h o w i n g re s s  lt e r in g I F NA M E D e f a ul t T h e de f a ul t i s d i s ab l e D e s c ri p t io n T h i s c o m ma n d s et s th e 8 0 2. 1 Q i n gr e ss  lt e ri n g f e at u re s E x a m pl e s A S U S (c o n g - if ) #i p ac c es s -g r o up 10 0 i n 1 5 . 4  i n t e r fa c e  I F N A M E S y n t ax i n t e rf a c e I FN A ME P a r a me t e rs I F N A ME : i n t e rf a c e’ s n a me
GigaX2024B/M L2 Managed Switch CLI Manual 196 C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o i nt e r fa c e I FN A M E S h o w s h o w i n t er f ac e I F N AM E D e f a ul t D e s c ri p t io n T h i s c o m ma n d c ha n g es th e o p e ra t io n t o in t er f ac e co m ma n d m o d e . E x a m pl e s A S U S (c o n g ) #i n te r f ac e f a 1/ 0 / 1 1 5 . 5  s h o w  in t e r f a c e  IF N A M E S y n t ax S h o w i n t er f ac e I F N AM E P a r a me t e rs I F N A ME : i n t e rf a c e’ s n a me C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T h i s c o m ma n d s ho w s t h e i nt e r fa c e d et a i l s ta t us . E x a m pl e s A S U S #s h o w i nt e rf a c e f a1 / 0/ 1 1 5 . 6  s h o w  in t e r f a c e  st a t u s S y n t ax S h o w i n t er f ac e s t a tu s P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T h i s c o m ma n d s ho w s t h e i nt e r fa c e s ta t u s. E x a m pl e s A S U S #s h o w i nt e rf a c e s ta t us 1 5 . 7  s h o w  in t e r f a c e  st a c k  < 1 - 8 > S y n t ax s h o w i n t er f ac e s t a ck <1 - 8> P a r a me t e rs < 1 - 8 >: st ac k ID C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t
GigaX2024B/M L2 Managed Switch CLI Manual 197 D e s c ri p t io n T h i s c o m ma n d s ho w s t h e i nt e r fa c e d et a i l s ta t us w it h s p ec i  c s t a c k . E x a m pl e s A S U S #s h o w i nt e rf a c e s ta c k 1 1 5 . 8  i n t e r fa c e  v l a n V L A N- I D S y n t ax i n t e rf a c e v la n VL A N -I D P a r a me t e rs v l a n Se le ct a v l an to c on  gu r e V L A N -I D Vl a n’ s i d C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w s h o w v l a n[ V LA N ID ] D e f a ul t D e s c ri p t io n T h is c om ma nd c ha n g e s th e sy st em v l a n t o sp ec i c vl a n in te rf ac e c o m m an d mo d e. E x a m pl e s A S U S (c o n g ) #i n te r f ac e v l an 1 1 5 . 9 i p a d dr e s s A . B . C . D / M S y n t ax i p a dd r e ss A . B . C. D /M P a r a me t e rs a d d r es s Se t th e IP a d d r e ss of an i nt e rf a ce A . B . C. D / M IP a dd re ss (e . g. 10 . 0 .0 . 1/ 8 ) C o m m an d Mo d e L 3 In te r f ac e m o de N o / c le a r n o i p a d dr e ss A . B . C. D / M S h o w s h o w r u n ni n g- c on  g D e f a ul t D e s c ri p t io n T h i s c o m ma n d s et s th e i p a d d re s s f or i nd i ca t ed i nt e rf a ce . E x a m pl e s A S U S (c o n g - if ) # i p a d dr e ss 1 92 . 19 2 .1 . 1 1 / 2 4 1 5 . 1 0  ac c e p t a b l e  f ra m e - t y p e S y n t ax a c c e pt a b le fr a me - t yp e ( a ll | di s ca r da l l | v la n -t a g ge d -o n ly ) P a r a me t e rs a l l -> an y k in d of fr a me t yp e i s a c c ep t ed
GigaX2024B/M L2 Managed Switch CLI Manual 198 d i s c ar d a ll -> di sc ar d a l l f r am e i s a c c ep t ed v l a n -t a g ge d -o n ly - > on ly v l an - ta g f r a me is ac c e pt e d C o m m an d Mo d e I nt er fa c e m o de N o / c le a r s h o w s h o w i n t er f ac e I F N AM E D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e ac c ep t ab l e f r am e t y p e c on  gu r a ti o n c om m a nd on t h e sw i t ch st a ck o r s ta n da l o ne sw i tc h to se t t h e t y pe of t he a c c e pt a b le f r a m e, f or an y k i n d o f f ra m e t y pe is a cc e pt e d o r o n ly vl a n -t a g f r a m e i s a c ce p te d . E x a m pl e s A S U S (c o n g - if ) #a c c ep t ab l e f r am e -t y pe a ll 1 5 . 1 1  d up l e x  ( f u l l| h a l f ) S y n t ax d u p l ex ( fu l l| h al f ) P a r a me t e rs f u l l - > Po rt i s i n h a lf - du p l ex mo d e h a l f - > Po r t i s i n f u ll - d up l ex mo d e C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o d up l e x S h o w s h o w i n t er f ac e I F N AM E D e f a ul t T h e de f a ul t i s F u l l D e s c ri p t io n U s e th e du p le x i n t er f ac e c o n g u ra t io n co m ma n d o n t h e s wi t c h s t a c k o r o n a st a n da l on e s w i tc h t o s p e ci f y t he d up l ex mo d e o f o p e r at i o n f or Fa s t E t he r ne t an d G i ga b i t E th e rn e t p o rt s . U s e t he n o f or m of th i s c o mm a nd to r et u rn th e po r t t o i t s d ef a ul t va l ue . E x a m pl e s A S U S (c o n g - if ) # d u pl e x f ul l 1 5 . 1 2  o w c o n t r o l  ( r x | t x | b o t h )  ( on | o f f ) S y n t ax  o w c on t r ol (r e ce i v e| s en d |b o t h) (o n |o f f ) P a r a me t e rs r x - > se ts w h et h e r t he in t e rf a ce ca n re c ei v e  o w- c o n t ro l p a ck e ts f ro m a re m o te de v ic e
GigaX2024B/M L2 Managed Switch CLI Manual 199 t x - > se ts w h et h er t he in t er f a ce ca n s e n d  ow - c o n t ro l pa c ke t s t o a re m ot e de v ic e b o t h - > se ts w he t h er th e i n t er f ac e c a n r e ce i ve a nd s e n d  o w -c o nt r ol p ac k et s f r o m a r e mo t e d e vi c e o f f -> di s a bl e a n i n t er f ac e t o op e ra t e w i th an a t t a ch e d d e vi c e t h at is re q u ir e d t o s e nd or re c e iv e  o w- c o nt r ol p a c k et s o n - > al l o ws an in t e rf a ce to o pe r at e w i t h a n a t t a ch e d d e vi c e t h at is re q u ir e d t o s e nd or re c e iv e  o w- c o nt r ol p a c k et s C o m m an d Mo d e I nt er fa c e m o de N o / c le a r N o  ow c o nt r ol S h o w s h o w i n t er f ac e I F N AM E D e f a ul t r e c e iv e on , s e nd o n D e s c ri p t io n T h i s c o m ma n d s et s th e i n te r f ac e  o wc o n tr o l m et h o d. E x a m pl e s A S U S (c o n g - if ) #  o wc o nt r ol b ot h o n 1 5 . 1 3 au t o - n e g o t ia t i o n S y n t ax a u t o -n e g ot i at i on P a r a me t e rs C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o a ut o - ne g ot i at i o n S h o w s h o w l 2 _ in t er f ac e IF N AM E D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e au t o- n eg o t ia t io n c o n g u ra t io n co m ma n d o n t h e s wi t c h s t a c k o r s t an d al o n e s wi t ch t o s et au t o -n e go t ia t i on st a tu s of th e p o r t . E x a m pl e s A S U S (c o n g - if ) # a u to - ne g ot i a ti o n 1 5 . 1 4 sp e e d ( 1 0 | 10 0 | 1 0 0 0 ) S y n t ax s p e e d ( 1 0| 1 00 | 10 0 0 ) P a r a me t e rs
GigaX2024B/M L2 Managed Switch CLI Manual 200 C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o s pe e d S h o w s h o w l 2 _ in t er f ac e IF N AM E D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e sp e ed co n  gu r at i on c om m an d o n th e s w it c h s t ac k o r s t a n da l o ne sw i tc h to se t s p e ed st a tu s of th e p o r t. E x a m pl e s A S U S (c o n g - if ) #s p e ed 10 0 1 5 . 1 5 sh u t d o w n S y n t ax s h u t do w n P a r a me t e rs C o m m an d Mo d e I nt er fa c e c o n g ur a t io n N o / c le a r n o s hu t d ow n S h o w s h o w r u n ni n g- c on  g D e f a ul t D e s c ri p t io n T h e sh u t do w n c om m a nd fo r a p or t c a us e s i t t o s t o p f or w ar d i ng . Y o u c a n e n ab l e t h e p or t w i t h t he no s hu t do w n c o mm a nd . T h e no s hu t do w n c o mm a nd ha s no ef fe ct i f t he po r t i s a s t a t ic - a cc e ss po r t a s si g ne d to a V LA N th a t h as b ee n d e le t e d, s u s p en d e d, or sh u t d o wn . T h e po r t m u st r s t b e a me m be r of an a c t i ve V LA N b e fo r e i t c a n b e r e -e n ab l e d. O n l y o n e m a na g em e n t V LA N i n t er f ac e c a n b e a c ti v e a t a ti m e . T h e re m a in i ng VL A N s a re sh u t d o wn . I n t he s ho w r u nn i n g- c on  g c o mm a nd , t h e a c ti v e m a na g em e nt V L A N i n t er f ac e i s th e o n e w i th o ut th e sh u td o wn c om m an d d i s p la y e d. E x a m pl e s A S U S (c o n g - if ) # s h ut d ow n 1 5 . 1 6  de f a u l t - p r io r i t y  < 0 - 7> S y n t ax d e f a ul t - pr i or i ty < 0- 7 > P a r a me t e rs < 0 - 7 > Co s pr io r it y C o m m an d Mo d e I nt er fa c e m o de
GigaX2024B/M L2 Managed Switch CLI Manual 201 N o / c le a r n o d ef a u lt - pr i or i t y S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e de f au l t_ p r io r it y c o n g u ra t io n co m ma n d o n t h e s wi t c h s t a c k o r s t an d al o n e s wi t ch t o s et co s pr i or i ty o f t he po r t . E x a m pl e s A S U S (c o n g - if ) # d e fa u lt - pr i o ri t y 3 1 5 . 1 7  md i x S y n t ax m d i x P a r a me t e rs C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o m di x S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e m di x c o mm a nd on th e s wi t ch st a ck o r s t an d al o ne sw i tc h t o s et m di x o f t h e p o rt . E x a m pl e s A S U S (c o n g - if ) #m d i x 1 5 . 1 8 de s c r i p t i o n . L I N E S y n t ax d e s c ri p t io n . L IN E P a r a me t e rs S t r i ng C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o d es c r ip t io n S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e de s cr i pt i o n c om m an d on th e s w i tc h s t ac k or st a nd a l on e s w i t ch t o s et de s c ri p ti o n o f t h e p or t . E x a m pl e s A S U S (c o n g - if ) #d e s cr i pt i on r d1 0
GigaX2024B/M L2 Managed Switch CLI Manual 202 1 5 . 1 9 li n e l o o p b ac k S y n t ax L i n e l o o pb a ck P a r a me t e rs C o m m an d Mo d e I nt er fa c e m o de N o / c le a r n o l in e lo o pb a ck S h o w D e f a ul t E n a b le o r d ep e nd s on OD M c u s to m er D e s c ri p t io n U s e th e li n e l oo p b ac k c o mm a n d o n t he s wi t ch st a c k o r s t a n da l o ne sw i tc h to de t ec t lo o pb a ck o f t he po r t . E x a m pl e s A S U S (c o n g - if ) #n o li n e l oo p b ac k 16. DHCP Client: 1 6 . 1 i p d h cp c l i e n t S y n t ax i p d hc p cl i en t P a r a me t e rs C o m m an d Mo d e I nt er fa c e m o de D e f a ul t D e s c ri p t io n S t a r t d h cp cl i en t E x a m pl e s A S U S (c o n g - if ) #i p dh c p c li e n t 1 6 . 2 n o i p d h c p c l i e nt S y n t ax n o i p d h cp cl i en t P a r a me t e rs C o m m an d Mo d e I nt er fa c e m o de D e f a ul t D e s c ri p t io n S t o p d h c p c li e nt E x a m pl e s A S U S (c o n g - if ) # n o i p d h cp c li e nt
GigaX2024B/M L2 Managed Switch CLI Manual 203 1 6 . 3 i p d h cp c l i e n t re n e w S y n t ax i p d hc p cl i en t r e n ew P a r a me t e rs C o m m an d Mo d e I nt er fa c e m o de D e f a ul t D e s c ri p t io n T o g e t th e d h cp i p a ga i n E x a m pl e s A S U S (c o n g - if ) # i p d h cp cl i e nt re n ew 17. DHCP Snooping: 1 7 . 1 i p d h cp s n o o p i n g S y n t ax i p d hc p sn o op i ng P a r a me t e rs C o m m an d Mo d e C on g ur e T e r m i n a l M od e N o / c le a r n o i p d h cp sn o op i n g s h o w s h o w i p dh c p s no o p in g D e f a ul t D e s c ri p t io n E n a b le d hc p s n oo p i ng gl o ba l l y . E x a m pl e s A S U S (c o n g ) # i p d h cp sn o op i n g 1 7 . 2 i p d h cp s n o o p i n g v l a n V L A N S y n t ax i p d hc p sn o op i ng v la n V L AN P a r a me t e rs V L A N R a n ge C o m m an d Mo d e C on g ur e T e r m i n a l M od e N o / c le a r n o i p d h cp sn o op i n g v la n V L A N s h o w s h o w i p dh c p s no o p in g D e f a ul t
GigaX2024B/M L2 Managed Switch CLI Manual 204 D e s c ri p t io n E n a b le D HC P s n o o pi n g o n a VL A N o r r a ng e o f V L A Ns . T h e r a n g e i s 1 to 30 0 0 . Y o u c an en t er a s i ng l e V L AN ID id e n ti  ed by V L A N I D nu m be r , a se r i es of VL A N I D s s ep a r at e d b y c o mm a s, a r a ng e of VL A N I D s s ep a ra t e d b y h yp h e ns , o r a r an g e o f V L AN I D s se p a ra t ed by e nt e ri n g t h e s ta r ti n g a n d e nd i n g V LA N I D s s e p a ra t e d b y a s p a ce . E x a m pl e s A S U S (c o n g ) # i p d h cp sn o op i n g v la n 1 - 1 00 1 7 . 3 i p d h cp s n o o p i n g t r u s t S y n t ax i p d hc p sn o op i ng t ru s t P a r a me t e rs C o m m an d Mo d e I nt er fa c e M o de N o / c le a r n o i p d h cp sn o op i n g t ru s t s h o w s h o w i p dh c p s no o p in g D e f a ul t D e s c ri p t io n ( O p t io n a l) Co n g u r e t he in t e rf a ce as t ru s te d o r un t ru s te d . Y ou c a n us e th e n o k e y wo r d t o c o n g ur e a n in t er f ac e to re c ei v e m e s s ag e s f r om an u nt r us t ed c li e nt . T h e de f au l t i s u n tr u s te d . E x a m pl e s A S U S (c o n g - if ) # i p d h cp sn o o pi n g t ru s t 1 7 . 4 s h o w ip d h c p s n oo p i n g S y n t ax s h o w i p dh c p s no o p in g P a r a me t e rs C o m m an d Mo d e E na bl e M o de N o / c le a r s h o w D e f a ul t D e s c ri p t io n D H C P s n o o pi n g c o n g ur a ti o n i s d i sp l a ye d E x a m pl e s A S U S #s h o w i p d hc p sn o op i ng
GigaX2024B/M L2 Managed Switch CLI Manual 205 1 7 . 5 s h o w ip d h c p s n oo p i n g b i n d i ng S y n t ax s h o w i p dh c p s no o p in g b i nd i n g P a r a me t e rs C o m m an d Mo d e E na bl e M o de N o / c le a r s h o w D e f a ul t D e s c ri p t io n T o d i s p la y l o gg e d i n fo r ma t i on , I f “ b i nd i ng ” i s gi v en , s n o op e d D H C P b i n d in g s a r e d is p la y e d. E x a m pl e s A S U S #s h o w i p d hc p sn o op i ng b in d in g 18. IP Route: 1 8 . 1  i p  f o rw a r d i n g S y n t ax i p f or w a rd i ng P a r a me t e rs f o r w ar d i ng T u r n o n IP f o r w a rd i ng C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o i p f o rw a rd i ng S h o w s h o w i p fo r wa r di n g D e f a ul t I P f or wa rd i ng is de f a ul t o n D e s c ri p t io n T h i s c o m ma n d w il l tu r n o n I P f o r wa r d in g f u nc t i on E x a m pl e s A S U S (c o n g ) #i p f o r wa r di n g 1 8 . 2 i p r o u t e A . B . C . D A . B . C . D ( A . B . C . D | I N T E R F A C E ) S y n t ax i p r ou t e A . B. C .D A . B . C. D (A . B. C .D | I NT E RF A C E ) P a r a me t e rs r o u t e Es t ab l i sh st a ti c ro u te s A . B . C. D IP d e s t in a ti o n p r e x
GigaX2024B/M L2 Managed Switch CLI Manual 206 A . B . C. D IP d es ti na t io n p r e x ma s k A . B . C. D IP g a t e wa y a d dr e s s I N T E RF A C E I P ga t ew a y i n te r fa c e n a me C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o i p r o ut e A . B. C .D A . B . C .D (A . B. C . D| I NT E RF A C E ) S h o w s h o w i p ro u te s h o w i p ro u te A . B . C. D s h o w r u n ni n g- c on  g D e f a ul t D e s c ri p t io n T h i s c o m ma n d s et s th e i p r o u te in th i s s y st e m E x a m pl e s A S U S (c o n g ) #i p r o u te 19 2 .1 9 2 .1 . 25 4 2 5 5 .2 5 5. 2 55 . 0 1 8 . 3 i p r o u t e A . B . C . D A . B . C . D ( A . B . C . D | I N T E R F A C E ) < 1 - 2 5 5 > S y n t ax i p r ou t e A . B. C .D A . B . C. D (A . B. C .D | I NT E RF A C E ) <1 - 2 55 > P a r a me t e rs r o u t e Es t ab l i sh st a ti c ro u te s A . B . C. D IP d e s t in a ti o n p r e x A . B . C. D IP d es ti na t io n p r e x ma s k A . B . C. D IP g a t e wa y a d dr e s s I N T E RF A C E I P ga t ew a y i n te r fa c e n a me < 1 - 2 55 > Di st a nc e v a l ue fo r t h i s r ou t e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o i p r o ut e A . B. C .D A . B . C .D (A . B. C . D| I NT E RF A C E ) < 1- 2 55 > S h o w s h o w i p ro u te s h o w r u n ni n g- c on  g D e f a ul t D e s c ri p t io n T h i s c o m ma n d s et s th e i p r o u te in th i s s y st e m w i th di s ta n c e v a l u e f o r t hi s r o u te . E x a m pl e s A S U S (c o n g ) #i p r o u te 19 2 .1 9 2 .1 . 25 4 2 5 5 .2 5 5. 2 55 1 0
GigaX2024B/M L2 Managed Switch CLI Manual 207 1 8 . 4 i p r o ut e A .B . C . D / M ( A. B . C . D | I N TE R F A C E ) S y n t ax i p r ou t e A . B. C .D / M ( A .B . C. D |I N T ER F A C E ) P a r a me t e rs r o u t e Es t ab l i sh st a ti c ro u te s A . B . C. D / M IP d es ti na t io n p r e x (e . g. 10 . 0 .0 . 0/ 8 ) A . B . C. D IP g a t e wa y a d dr e s s I N T E RF A C E I P ga t ew a y i n te r fa c e n a me C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o i p r o ut e A . B. C .D / M ( A .B . C. D | IN T ER F A C E ) S h o w s h o w i p ro u te s h o w i p ro u te A . B . C. D / M s h o w r u n ni n g- c on  g D e f a ul t D e s c ri p t io n T h i s c o m ma n d s et s th e i p r o u te in th i s s y st e m E x a m pl e s A S U S (c o n g ) #i p r o u te 19 2 .1 9 2 .1 . 25 4 /2 4 1 8 . 5 i p r o u t e A . B . C . D / M ( A . B . C . D | I N T E R F A C E ) < 1 - 2 5 5 > S y n t ax i p r ou t e A . B. C .D / M ( A .B . C. D |I N T ER F A C E ) < 1 -2 5 5 > P a r a me t e rs r o u t e Es t a bl i sh st a t ic ro u te s A . B . C. D / M IP d es ti na t io n p r e x (e . g. 10 . 0 .0 . 0/ 8 ) A . B . C. D IP g a t e wa y a d dr e s s I N T E RF A C E I P ga t ew a y i n te r fa c e n a me < 1 - 2 55 > Di st a nc e v a l ue fo r t h i s r ou t e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r n o i p r o ut e A . B. C .D / M ( A .B . C. D | IN T ER F A C E ) < 1 - 25 5 > S h o w s h o w i p ro u te s h o w r u n ni n g- c on  g D e f a ul t D e s c ri p t io n T h i s c o m ma n d s et s th e i p r o u te in th i s s y st e m w i th di s ta n c e
GigaX2024B/M L2 Managed Switch CLI Manual 208 v a l u e f o r t hi s r o u te E x a m pl e s A S U S (c o n g ) #i p r o u te 19 2 .1 9 2 .1 . 25 4 /2 4 10 1 8 . 6 s h o w ip r o u t e s up e r n e t s - o n l y S y n t ax s h o w i p ro u te su p e rn e ts - on l y P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r D e f a ul t D e s c ri p t io n E x a m pl e s A S U S # s h ow ip ro u t e s up e rn e t s- o nl y 19. System Management: 1 9 . 1 s h o w sw i t c h G X 2 0 24 M st a ck i ng o nl y S y n t ax s h o w s w i tc h P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n S h o w s t a ck i ng in f o rm a ti o n E x a m pl e s A S U S # s h ow sw i tc h 1 9 . 2 s h o w sw i t c h s t a tu s G X 2 0 24 M st a ck i ng o nl y S y n t ax s h o w s w i tc h s t at u s
GigaX2024B/M L2 Managed Switch CLI Manual 209 P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n S h o w s t a ck i ng in f o rm a ti o n E x a m pl e s A S U S # s h ow sw i tc h st a tu s 1 9 . 3 s w i t c h < 1 - 8 > G X 2 0 24 M st a ck i ng o nl y S y n t ax s w i t ch < 1- 8 > P a r a me t e rs < 1 - 8 > st ac k i d C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r D e f a ul t D e s c ri p t io n T o c o n  gu r e t he s ta c k i d t h e s wi t ch b el o ng to . E x a m pl e s A S U S (c o n g ) # s wi t c h 3 1 9 . 4 s w i t c h p r i o r i t y < 1 - 8 > G X 2 0 24 M st a ck i ng o nl y S y n t ax S w i t ch p ri o ri t y < 1 -8 > P a r a me t e rs < 1 - 8 > pr io ri t y v a lu e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r D e f a ul t D e s c ri p t io n T o c o n  gu r e t he p ri o ri t y t h e s wi t ch b el o ng to . hi g he s t p r io r it y w i l l b e e le c t ed as ma s t er E x a m pl e s A S U S (c o n g ) # s wi t c h p ri o ri t y 3
GigaX2024B/M L2 Managed Switch CLI Manual 210 1 9 . 5  a r c h i ve  d o w n l o a d - sw  / o v e r w r it e  t f t p :  IM A G E S y n t ax a r c h iv e do w nl o ad - s w / ov e rw r i te tf t p: I MA G E P a r a me t e rs I M A G E I ma g e  le C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e ar c hi v e d o wn l oa d -s w /o v er w ri t e c o n g ur a t io n c o mm a n d o n t he s wi t ch st a c k o r s ta n d al o ne sw i t ch to do w n lo a d a n e w c o p y o f so f tw a re f ro m a se r v er an d o v e rw r it e a n ex i st i ng i ma g e. E x a m pl e s A S U S # a r ch i ve do w n lo a d- s w / o ve r wr i te t ft p :1 9 2. 1 9 2. 1 .1 3 1/ i m a g e. i m g 1 9 . 6  c o n  g ur e  t e r m i n al S y n t ax c o n  gu r e t e rm i na l P a r a me t e rs t e r m in a l Co n g ur a ti o n t e rm i na l C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e wr i te co n  gu r at i on c om m an d o n th e s w it c h s t ac k o r s t a n da l o ne sw i tc h to co n g u r at i on fr o m v t y i nt e r fa c e. E x a m pl e s A S U S # c o n g ur e t e r mi n al 1 9 . 7  c o p y  ru n n i n g - c o n g  s t a r t u p- c o n  g S y n t ax c o p y r u n ni n g- c on  g s t ar t up - c on  g P a r a me t e rs r u n n in g - co n g Co py f r om cu r re n t s y st e m c o n g ur a ti o n s t a r tu p - co n g Co py f ro m s t ar t up c on  gu r at i o n C o m m an d Mo d e P ri vi le g e d E XE C m o d e
GigaX2024B/M L2 Managed Switch CLI Manual 21 1 N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th e co p y c on  g ur a ti o n c o mm a nd on t he sw i tc h st a ck or s t a n da l o ne sw i tc h to co p y r u nn i ng co n  gu r at i on s ta r tu p -c o n g . E x a m pl e s A S U S # c o py ru n ni n g -c o n g s t a rt u p- c on  g 1 9 . 8  c o p y  st a r t u p - c o n g  t f t p :  U R L S y n t ax c o p y s t a rt u p- c on  g t f tp : U R L P a r a me t e rs s t a r tu p - co n g Co py f ro m s t ar t u p c on  gu r a ti o n f t p : Co p y t o t f tp : l e s y st e m U R L A U RL be gi n n in g w i th t hi s p r e x C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n C o p y t h e  l e i n F l as h m e mo r y t o t h e r o ot di r ec t o ry of th e T F T P s e r v er . E x a m pl e s A S U S # c o py st a rt u p -c o n g t f t p: 19 2 .1 9 2 .1 . 13 1 1 9 . 9  c o p y  tf t p :  U R L  s t a r t u p - co n  g S y n t ax c o p y t f t p: UR L s t ar t up - c on  g P a r a me t e rs f t p : Co p y t o t f tp : l e s y st e m U R L A U RL be gi n n in g w i th t hi s p r e x s t a r tu p - co n g Co py f ro m s t ar t u p c on  gu r a ti o n C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n C o p y t h e  l e i n t h e T F T P s er ve r t o t he F la s h m em o r y .
GigaX2024B/M L2 Managed Switch CLI Manual 212 E x a m pl e s A S U S # c o py tf t p: 1 92 . 19 2 .1 . 3 1 s ta r tu p - co n g 1 9 . 1 0 di s a b l e S y n t ax d i s a bl e P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t D e s c ri p t io n T h i s c o m ma n d t ur n of f p r i v il e ge d m o d e a nd ba c k t o u s er m od e E x a m pl e s A S U S #d i s ab l e 1 9 . 1 1 e n a b l e S y n t ax e n a b le P a r a me t e rs C o m m an d Mo d e U se r mo d e N o / c le a r S h o w D e f a ul t D e s c ri p t io n T h i s c o m ma n d l et u se r e n te r en a bl e m o d e a nd tu r n o n p r iv i l eg e d m o d e c o m ma n d. E x a m pl e s A S U S >e n a bl e 1 9 . 1 2 en d S y n t ax e n d P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e , C o n g u re te r mi n a l m od e , I n te r fa c e m o d e N o / c le a r S h o w
GigaX2024B/M L2 Managed Switch CLI Manual 213 D e f a ul t D e s c ri p t io n T h i s c o m ma n d l et u se r e n d c u rr e nt mo d e a n d d ow n to en a bl e m o d e . E x a m pl e s A S U S (c o n g ) #e n d 1 9 . 1 3  ex i t S y n t ax e x i t P a r a me t e rs C o m m an d Mo d e U se r mo d e , P ri v il e g ed EX E C m o de , C on  g ur e t e rm i n al mo d e, I n t e rf a c e m od e N o / c le a r S h o w D e f a ul t D e s c ri p t io n T h i s c o m ma n d l et u se r e x it c ur r en t m o d e a nd do w n t o p r ev i o us m o d e . E x a m pl e s A S U S (c o n g ) #e x it 1 9 . 1 4  ho s t n a m e  W OR D S y n t ax h o s t na m e W O RD P a r a me t e rs W O R D : Th is sy s te m ’s n et w or k n a m e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r N o h os t n am e [ H OS T N AM E ] S h o w s h o w r u n ni n g- c on  g D e f a ul t T h e de f a ul t s y st e m ’s ne t wo r k n a me is S wi t ch D e s c ri p t io n T h i s c o m ma n d s et s th e s y st e m ’s ne t wo r k n a me E x a m pl e s A S U S (c o n g ) #h o st n a me A S U S 1 9 . 1 5 li s t S y n t ax l i s t P a r a me t e rs
GigaX2024B/M L2 Managed Switch CLI Manual 214 C o m m an d Mo d e U se r mo d e , P ri v il e g ed EX E C m o de , C o n g u re te r mi n a l m od e , I n t e rf a c e m od e N o / c le a r S h o w D e f a ul t D e s c ri p t io n T h i s c o m ma n d l is t s a l l o f t h e c om m an d of th e o p e ra t io n m o d e. E x a m pl e s A S U S #l i s t 1 9 . 1 6 t r a c e l o g a d d ( d h c p - s n o o p i n g | d o t 1 x |g v r p | i g m p -s n o o p i n g | l a cp | s t p ) S y n t ax t r a c el o g a d d ( dh c p -s n oo p in g | do t 1x | gv r p |i g mp - sn o o pi n g| l ac p | st p ) P a r a me t e rs C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r t r a c el o g d e le t e ( d hc p -s n oo p i ng | do t 1x | g vr p |i g mp - s n o o pi n g |l a cp | st p ) S h o w D e f a ul t D i s a bl e tr a ce l og D e s c ri p t io n T h i s c o m ma n d s ta r t s t he sy s t em lo g gi n g t h e f un c t io n . E x a m pl e s A S U S (c o n g ) #t r ac e l og ad d d o t 1x 1 9 . 1 7 tr a c e l o g l ev e l ( c r i t ic a l | h i g h | l o w ) S y n t ax t r a c el o g l e ve l ( c r it i ca l | h ig h | lo w ) P a r a me t e rs C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r S h o w D e f a ul t T h e de f a ul t i s c r i ti c al D e s c ri p t io n T h i s c o m ma n d i s t o d e ci d e h o w m uc h m e s sa g e w il l be pr i nt . E x a m pl e s A S U S (c o n g ) #t r ac e l og le v el l ow
GigaX2024B/M L2 Managed Switch CLI Manual 215 1 9 . 1 8  pi n g  i p  WO R D S y n t ax p i n g i p WO R D P a r a me t e rs W O R D Pi ng de s ti n at i o n a dd r es s or ho s tn a m e C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t E n a b le D e s c ri p t io n T h i s c o m ma n d u se d to se n d e c ho me s sa g e s t o p in g de s ti n at i o n a d d r es s or ho s tn a m e E x a m pl e s A S U S #p i n g i p 1 92 . 1 92 . 1. 1 1 9 . 1 9  pi n g  W O R D S y n t ax p i n g W O R D P a r a me t e rs W O R D P i ng de s ti n a ti o n a dd r e ss or ho s t na m e C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t E n a b le D e s c ri p t io n T h i s c o m ma n d u se d to se n d e c ho me s sa g e s t o p in g de s ti n at i o n a d d r es s or ho s tn a m e E x a m pl e s A S U S #p i n g 1 92 . 19 2 . 1. 1 1 9 . 2 0 qu i t S y n t ax q u i t P a r a me t e rs C o m m an d Mo d e U se r mo d e , P ri v il e g ed EX E C m o de N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r
GigaX2024B/M L2 Managed Switch CLI Manual 216 D e s c ri p t io n U s e th e co m ma n d t o e x it cu r r en t m o de a nd do w n t o p r ev i ou s m o d e . E x a m pl e s A S U S #q u i t 1 9 . 2 1 re b o o t S y n t ax r e b o ot P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th i s c o mm a nd t o r eb o ot t he sy s te m . E x a m pl e s A S U S #r e b oo t 1 9 . 2 2  re l o a d  d e f au l t - c o n  g  l e S y n t ax r e l o ad d ef a ul t -c o n g l e P a r a me t e rs d e f a ul t - co n g th e d e fa u lt - co n  g  le  l e t h e ru n n in g -c o n g l e C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n U s e th i s c o mm a nd t o c op y a d ef a ul t -c o n g l e t o re p la c e t h e c u r r en t on e E x a m pl e s A S U S # r e lo a d d ef a u lt - co n g  le 1 9 . 2 3  sh o w  r u n n i ng - c o n  g S y n t ax s h o w r u n ni n g- c on  g P a r a me t e rs r u n n in g - co n g C u r r e nt op e ra t i ng co n g u r at i on C o m m an d Mo d e P ri vi le g e d E XE C m o d e
GigaX2024B/M L2 Managed Switch CLI Manual 217 D e f a ul t D e s c ri p t io n T o s h o w r u nn i ng - c on  g f ul e . E x a m pl e s A S U S # s h ow ru n ni n g -c o n g 1 9 . 2 4  sh o w  s t a r t up - c o n  g  S y n t ax s h o w s t a rt u p- c on  g P a r a me t e rs s t a r tu p - co n g C on te n t es of st a r tu p c o n g u ra t io n C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w s t ar t up - c on  g. E x a m pl e s A S U S # s h ow st a rt u p -c o n g 1 9 . 2 5 sh o w v e r s i on S y n t ax s h o w v e r si o n P a r a me t e rs v e r s io n D i s p l ay s I S S v e rs i on C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w  r mw a re v er s io n . E x a m pl e s A S U S # s h ow ve r si o n 1 9 . 2 6  sh o w  c a b l e -d i a g n o s t i c i n t e r f a c e  [I F N A M E ] S y n t ax s h o w c a b le - di a gn o s ti c i n te r f ac e [ I FN A M E] P a r a me t e rs I F N A ME i n t e rf a c e n am e ( e . q. : f a st e t he r ne t 1/ 0 / 1) C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r D e f a ul t D e s c ri p t io n T o s h o w c a bl e -d i a gn o st i c i n fo r ma t io n E x a m pl e s A S U S # s h ow ca b le - d ia g no s ti c in t er f ac e
GigaX2024B/M L2 Managed Switch CLI Manual 218 1 9 . 2 7 sh o w p r i v a te h e a l t h S y n t ax s h o w p r i va t e h ea l t h P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r D e f a ul t D e s c ri p t io n T o s h o w s y st e m m o ni t or in f o rm a ti o n E x a m pl e s A S U S # s h ow pr i va t e h e al t h 1 9 . 2 8 sh o w p r i v a te l e d S y n t ax s h o w p r i va t e l ed P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r D e f a ul t D e s c ri p t io n T o s h o w s y st e m l e d i nf o rm a t io n E x a m pl e s A S U S # s h ow pr i va t e l e d 1 9 . 2 9 sh o w p r i v a te m o d e l S y n t ax s h o w p r i va t e m od e l P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r D e f a ul t D e s c ri p t io n T o s h o w m o de l n a m e E x a m pl e s A S U S # s h ow pr i va t e m o de l
GigaX2024B/M L2 Managed Switch CLI Manual 219 1 9 . 3 0 sh o w u p t i m e S y n t ax s h o w u p t im e P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r D e f a ul t D e s c ri p t io n T o d i s p la y s y st e m u p ti m e E x a m pl e s A S U S # s h ow up t im e 1 9 . 3 1 sh o w c l o c k S y n t ax s h o w c l o ck P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r D e f a ul t D e s c ri p t io n T o s h o w c l oc k E x a m pl e s A S U S # s h ow cl o ck 1 9 . 3 2  cl o c k  s e t  TI M E  M O N T H D A Y  Y E A R S y n t ax c l o c k s e t T I M E M ON T H D A Y Y E A R P a r a me t e rs T I M E hh :m m :s s C u rr e nt T i m e M O N T H <1 - 12 > M on t h o f t h e y e ar D A Y < 1 - 3 1> Da y o f t h e m o nt h Y E A R <1 97 0- 20 3 7> Y e a r C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r D e f a ul t D e s c ri p t io n T o s e t ti m e E x a m pl e s A S U S # c l oc k s e t 1 5 :2 6 :0 2 4 6 2 0 06
GigaX2024B/M L2 Managed Switch CLI Manual 220 1 9 . 3 3 sh o w s y s l o g S y n t ax s h o w s y s lo g P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r D e f a ul t D e s c ri p t io n T o s h o w s y st e m l o g m es s ag e s E x a m pl e s A S U S # s h ow sy s lo g 1 9 . 3 4  sh o w  s y s l o g c o n  g u r a ti o n S y n t ax s h o w s y s lo g c o n g u ra t io n P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r D e f a ul t D e s c ri p t io n T o s h o w s y st e m l o g c on  gu r a ti o n E x a m pl e s A S U S # s h ow sy s lo g co n g u ra t i on 1 9 . 3 5 sy s l o g ( e n ab l e | d i s a b le ) S y n t ax s y s l og ( en a bl e |d i s ab l e) P a r a me t e rs d i s a bl e Di sa bl e sy s lo g p r o to c ol e n a b le En a bl e sy s lo g p r o to c ol C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r D e f a ul t D e s c ri p t io n T o e n a b le / di s ab l e s y st e m l o g p ro t oc o l E x a m pl e s A S U S (c o n g ) # s ys l o g e na b le
GigaX2024B/M L2 Managed Switch CLI Manual 221 1 9 . 3 6  sy s l o g  f a c il i t y  < 0 - 2 3> S y n t ax s y s l og f ac i li t y < 0 -2 3 > P a r a me t e rs f a c i li t y As si gn me s sa g e f a ci l it y < 0 - 2 3> F a c i li t y c o de C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r D e f a ul t D e s c ri p t io n T o c o n  gu r e s ys t e m l og Fa c i li t y c od e E x a m pl e s A S U S (c o n g ) # s ys l o g f ac i li t y 3 1 9 . 3 7 sy s l o g h o s tn a m e S y n t ax s y s l og h os t na m e P a r a me t e rs C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r D e f a ul t D e s c ri p t io n T u r n o n m es s a ge ho s tn a m e E x a m pl e s A S U S (c o n g ) # s ys l o g h os t na m e 1 9 . 3 8 sy s l o g s e r ve r - i p A . B .C . D S y n t ax s y s l og s er v er - ip A . B . C .D P a r a me t e rs A . B . C. D IP a dd re ss C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r D e f a ul t D e s c ri p t io n T o c o n  gu r e S ys l o g s er v er I P a d dr e s s E x a m pl e s A S U S (c o n g ) # s ys l o g s er v er - i p 1 92 . 16 8 . 1. 1
GigaX2024B/M L2 Managed Switch CLI Manual 222 1 9 . 3 9 sy s l o g s e v er i t y < 0 - 7 > S y n t ax s y s l og s ev e ri t y < 0 -7 > P a r a me t e rs < 0 - 7 > Se ve ri ty co d e C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r D e f a ul t D e s c ri p t io n A s s i gn m es s ag e p r i or i ty E x a m pl e s A S U S (c o n g ) # s ys l o g s ev e ri t y 2 1 9 . 4 0 sy s l o g t i m es t a m p S y n t ax s y s l og t im e st a mp P a r a me t e rs C o m m an d Mo d e C on g ur e te r mi n al m od e N o / c le a r D e f a ul t D e s c ri p t io n T u r n o n m es s a ge ti m es t a mp E x a m pl e s A S U S (c o n g ) # s ys l o g t im e st a m p 1 9 . 4 1  te l n e t  W O R D S y n t ax t e l n et W OR D P a r a me t e rs W O R D IP a d dr e ss o r h o st na m e o f a r em o te sy st e m C o m m an d Mo d e U se r mo d e , P ri v il e g ed EX E C m o de N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n t o t el n e t a i p a d d re s s E x a m pl e s A S U S # t e ln e t 1 92 . 1 92 . 1. 1 1
GigaX2024B/M L2 Managed Switch CLI Manual 223 1 9 . 4 2  te l n e t  W O R D P O R T S y n t ax t e l n et W OR D P O R T P a r a me t e rs W O R D IP a d dr e ss o r h o st na m e o f a r em o te sy st e m P O R T TC P P o rt n um b er C o m m an d Mo d e U se r mo d e , P ri v il e g ed EX E C m o de N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n t o t el n e t a i p a d d re s s E x a m pl e s A S U S # t e ln e t 1 92 . 1 92 . 1. 1 1 2 1 1 9 . 4 3  tr a c e r o u t e  W OR D S y n t ax t r a c er o u te WO R D P a r a me t e rs W O R D T ra ce r ou t e t o d es t i na t io n a d d re s s o r ho st na me C o m m an d Mo d e U se r mo d e , P ri v il e g ed EX E C m o de N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r D e s c ri p t io n E x a m pl e s A S U S # t r ac e ro u te 1 92 . 19 2 .1 . 1 1 1 9 . 4 4 wr i t e S y n t ax w r i t e P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e N o / c le a r S h o w D e f a ul t N o n e o r de p en d s o n O D M c us t o me r
GigaX2024B/M L2 Managed Switch CLI Manual 224 D e s c ri p t io n U s e th e wr i te co n  gu r at i on c om m an d o n th e s w it c h s t ac k o r s t a n da l o ne sw i tc h to wr i te r un n in g c o n g u ra t io n to me m or y , n e t w or k , o r t e rm i n al E x a m pl e s A S U S #w r i te 1 9 . 4 5 sh o w a r p S y n t ax s h o w a r p P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w a r p t ab l e . E x a m pl e s A S U S #s h o w a rp 1 9 . 4 6 no a r p A .B . C . D S y n t ax n o a rp A . B . C .D P a r a me t e rs C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o d e l e te ar p t a b le . E x a m pl e s A S U S #n o ar p 1 0 .0 . 0 .1 1 9 . 4 7  us e r  a d d  A CC O U N T  P A S S W O R D S y n t ax u s e r a d d A C CO U NT P A S SW O RD P a r a me t e rs A C C O UN T us er n am e P AS SW OR D pa ss w or d C o m m an d Mo d e C on g ur e te r mi n al m od e D e f a ul t D e s c ri p t io n T o a d d a n ew us e r a c co u nt E x a m pl e s A S U S # u s er ad d t e s t t es t
GigaX2024B/M L2 Managed Switch CLI Manual 225 1 9 . 4 8 us e r d e l e t e U S E R N A M E S y n t ax u s e r d e l et e U S ER N A ME P a r a me t e rs A C C O UN T us er n am e C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o d e l e te a u se r ac c ou n t E x a m pl e s A S U S # u s er de l et e te s t 1 9 . 4 9 sh o w u s e r S y n t ax s h o w u s e r P a r a me t e rs A C C O UN T us er n am e C o m m an d Mo d e P ri vi le g e d E XE C m o d e D e f a ul t D e s c ri p t io n T o s h o w a us e r a c co u nt E x a m pl e s A S U S # s h ow us e r