Asus TS300-E3 PS4 User Manual

Intel Intel Intel Intel Intel ® ® ® ® ® Pentium Pentium Pentium Pentium Pentium ® ® ® ® ® 4/Pentium 4/Pentium 4/Pentium 4/Pentium 4/Pentium ® ® ® ® ® D LGA775 D LGA775 D LGA775 D LGA775 D LGA775 Pedestal/5U Rackmount Pedestal/5U Rackmount Pedestal/5U Rackmount Pedestal/5U Rackmount Pedestal/5U Rackmount Server Server Server Server Server 1066/800 MHz Front Side Bus TS300-E3
ii ii ii ii ii Copyright © 2005 ASUSTeK COMPUTER INC. All Rights Reserved. Copyright © 2005 ASUSTeK COMPUTER INC. All Rights Reserved. Copyright © 2005 ASUSTeK COMPUTER INC. All Rights Reserved. Copyright © 2005 ASUSTeK COMPUTER INC. All Rights Reserved. Copyright © 2005 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”). ASUS provides this manual “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose. In no event shall ASUS, its directors, officers, employees, or agents be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of use or data, interruption of business and the like), even if ASUS has been advised of the possibility of such damages arising from any defect or error in this manual or product. Specifications and information contained in this manual ae furnished for informational use only, and are subject to change at any time without notice, and should not be construed as a commitment by ASUS. ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual, including the products and software described in it. Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing. Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners’ benefit, without intent to infringe. E2198 E2198 E2198 E2198 E2198 First Edition V1 First Edition V1 First Edition V1 First Edition V1 First Edition V1 August 2005 August 2005 August 2005 August 2005 August 2005
iii iii iii iii iii Contents Notices ............................................................................................... vii Safety information ............................................................................ viii About this guide ................................................................................. ix Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction 1.1 System package contents .................................................... 1-2 1.2 System specifications .......................................................... 1-4 1.3 Front panel features ............................................................. 1-5 1.4 Rear panel features .............................................................. 1-6 1.5 Internal features ................................................................... 1-7 1.6 LED information .................................................................... 1-9 Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2.1 Chassis cover ....................................................................... 2-2 2.1.1 Removing the side cover ........................................ 2-2 2.1.2 Reinstalling the side cover ...................................... 2-3 2.2 Motherboard overview .......................................................... 2-4 2.3 Central Processing Unit (CPU) .............................................. 2-5 2.3.1 Installing the CPU .................................................... 2-5 2.3.2 Installing the CPU heatsink and airduct assembly .. 2-8 2.4 System memory ................................................................. 2-10 2.4.1 Overview ............................................................... 2-10 2.4.2 Memory configurations ......................................... 2-10 2.4.3 Installing a DIMM ................................................... 2-11 2.4.4 Removing a DIMM ................................................. 2-11 2.5 Front panel assembly ......................................................... 2-12 2.5.1 Removing the front panel assembly ..................... 2-12 2.5.2 Reinstalling the front panel assembly ................... 2-14 2.6 5.25-inch drives ................................................................. 2-15 2.7 Hard disk drives .................................................................. 2-18 2.7.1 Installing a hot-swap SATA/SCSI HDD .................. 2-18 2.7.2 Installing an HDD dummy cover ............................ 2-20 2.8 Expansion cards .................................................................. 2-21 2.8.1 Installing an expansion card .................................. 2-21 2.8.2 Removing an expansion card ................................ 2-22
iv iv iv iv iv Contents 2.9 Cable connections .............................................................. 2-23 2.9.1 Motherboard connections ..................................... 2-23 2.9.2 SATA backplane connections ............................... 2-24 2.9.3 SCSI backplane connections ................................. 2-27 2.10 Removable components ..................................................... 2-30 2.10.1 Chassis fan ........................................................... 2-30 2.10.2 HDD blower ........................................................... 2-32 2.10.3 SATA/SCSI backplane ........................................... 2-35 2.10.4 Floppy disk drive ................................................... 2-37 2.10.5 Front I/O board .................................................... 2-39 2.10.6 Chassis footpads and roller wheels ...................... 2-41 2.10.7 Power supply unit ................................................. 2-43 Chapter 3: Chapter 3: Chapter 3: Chapter 3: Chapter 3: Installation option Installation option Installation option Installation option Installation option Preparing the system for rack mounting ......................................... 3-2 Chapter 4: Chapter 4: Chapter 4: Chapter 4: Chapter 4: Motherboard info Motherboard info Motherboard info Motherboard info Motherboard info 4.1 Motherboard layouts ............................................................ 4-2 4.2 Jumpers ................................................................................ 4-5 4.3 Internal connectors ............................................................ 4-10 Chapter 5: Chapter 5: Chapter 5: Chapter 5: Chapter 5: BIOS information BIOS information BIOS information BIOS information BIOS information 5.1 Managing and updating your BIOS ........................................ 5-2 5.1.1 Creating a bootable floppy disk .............................. 5-2 5.1.2 AFUDOS utility ........................................................ 5-3 5.1.3 ASUS CrashFree BIOS 2 utility ................................ 5-6 5.1.4 ASUS Update utility ................................................ 5-8 5.2 BIOS setup program ........................................................... 5-11 5.2.1 BIOS menu screen ................................................. 5-12 5.2.2 Menu bar ............................................................... 5-12 5.2.3 Navigation keys .................................................... 5-12 5.2.4 Menu items ........................................................... 5-13 5.2.5 Sub-menu items ................................................... 5-13 5.2.6 Configuration fields .............................................. 5-13 5.2.7 Pop-up window ..................................................... 5-13 5.2.8 Scroll bar .............................................................. 5-13 5.2.9 General help .......................................................... 5-13
v v v v v Contents 5.3 Main menu .......................................................................... 5-14 5.3.1 System Time ......................................................... 5-14 5.3.2 System Date ......................................................... 5-14 5.3.3 Legacy Diskette A ................................................ 5-14 5.3.4 IDE Configuration .................................................. 5-15 5.3.5 Primary/Secondary/Third IDE Master/Slave ......... 5-16 5.3.6 System Information .............................................. 5-18 5.4 Advanced menu .................................................................. 5-19 5.4.1 MPS Configuration ................................................ 5-19 5.4.2 Remote Access Configuration .............................. 5-20 5.4.3 CPU Configuration ................................................. 5-21 5.4.4 Chipset Configuration ........................................... 5-23 5.4.5 Onboard Devices Configuration ............................ 5-27 5.4.6 PCI/PnP Configuration .......................................... 5-28 5.5 Power menu ........................................................................ 5-29 5.5.1 APM Configuration ................................................ 5-29 5.5.2 Hardware Monitor ................................................. 5-32 5.6 Boot menu .......................................................................... 5-34 5.6.1 Boot Device Priority .............................................. 5-34 5.6.2 Boot Settings Configuration ................................. 5-35 5.6.3 Security ................................................................ 5-36 5.7 Exit menu ........................................................................... 5-39 Chapter 6: Chapter 6: Chapter 6: Chapter 6: Chapter 6: RAID Configuration RAID Configuration RAID Configuration RAID Configuration RAID Configuration 6.1 Setting up RAID .................................................................... 6-2 6.1.1 RAID definitions ...................................................... 6-2 6.1.2 Installing hard disk drives ....................................... 6-3 6.1.3 Setting the RAID item in BIOS ................................ 6-3 6.1.4 RAID configuration utilities ..................................... 6-4 6.2 LSI Logic Embedded SATA RAID Setup Utility ...................... 6-5 6.2.1 Creating a RAID 0 or RAID 1 set ............................. 6-6 6.2.2 Creating a RAID 10 set ......................................... 6-11 6.2.3 Adding or viewing a RAID configuration ............... 6-15 6.2.4 Initializing the logical drives .................................. 6-18 6.2.5 Rebuilding failed drives ......................................... 6-23 6.2.6 Checking the drives for data consistency ............ 6-25
vi vi vi vi vi Contents 6.2.7 Deleting a RAID configuration ............................... 6-28 6.2.8 Selecting the boot drive from a RAID set ............. 6-29 6.2.9 Enabling the WriteCache ...................................... 6-30 6.3 Global Array Manager ......................................................... 6-30 6.4 LSI Logic Configuration Utility (for PS4 model only) ......... 6-31 6.4.1 Boot Adapter List ................................................. 6-32 6.4.2 Global Properties .................................................. 6-33 6.4.3 Adapter Properties ............................................... 6-35 6.4.4 Creating a RAID 1 (Mirror) set .............................. 6-42 6.4.5 Creating a RAID 0 (Stripe) set .............................. 6-44 6.4.6 Running the Diagnostic Mode ............................... 6-44 6.4.7 Managing arrays ................................................... 6-46 Chapter 7: Chapter 7: Chapter 7: Chapter 7: Chapter 7: Driver installation Driver installation Driver installation Driver installation Driver installation 7.1 RAID driver installation ......................................................... 7-2 7.1.1 Creating a RAID driver disk ..................................... 7-2 7.1.2 Installing the RAID controller driver ........................ 7-3 7.2 LAN driver installation ........................................................ 7-12 7.2.1 Windows ® 2000/2003 Server .............................. 7-12 7.2.2 Red Hat ® Enterprise ver. 3.0 ................................ 7-13 7.3 VGA driver installation ........................................................ 7-14 7.3.1 Windows ® 2000 Server ........................................ 7-14 7.3.2 Windows ® 2003 Server ........................................ 7-15 7.3.3 Red Hat ® Enterprise ver. 3.0 ................................ 7-15 7.4 Management applications and utilities installation ............. 7-16 7.4.1 Running the support CD ....................................... 7-16 7.4.2 Drivers menu ........................................................ 7-16 7.4.3 Management Software menu ................................ 7-17 7.4.4 Utilities menu ........................................................ 7-17 7.4.5 Contact information ............................................. 7-17 Appendix: Appendix: Appendix: Appendix: Appendix: Reference information Reference information Reference information Reference information Reference information A.1 450 W single power supply .................................................. A-2 A.1.1 General description ................................................. A-2 A.1.2 Specifications ......................................................... A-3 A.2 Simple fixes .......................................................................... A-4
vii vii vii vii vii Notices Federal Communications Commission Statement Federal Communications Commission Statement Federal Communications Commission Statement Federal Communications Commission Statement Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any interference received including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with manufacturer’s instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. WARNING! WARNING! WARNING! WARNING! WARNING! The use of shielded cables for connection of the monitor to the graphics card is required to assure compliance with FCC regulations. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. Canadian Department of Communications Statement Canadian Department of Communications Statement Canadian Department of Communications Statement Canadian Department of Communications Statement Canadian Department of Communications Statement This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. This class B digital apparatus complies with Canadian ICES-003. This class B digital apparatus complies with Canadian ICES-003. This class B digital apparatus complies with Canadian ICES-003. This class B digital apparatus complies with Canadian ICES-003. This class B digital apparatus complies with Canadian ICES-003.
viii viii viii viii viii Safety information Electrical Safety Electrical Safety Electrical Safety Electrical Safety Electrical Safety • Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged. • To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. • When adding or removing any additional devices to or from the system, ensure that the power cables for the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you add a device. • If the power supply is broken, do not try to fix it by yourself. Contact a qualified service technician or your dealer. Operation Safety Operation Safety Operation Safety Operation Safety Operation Safety • Any mechanical operation on this server must be conducted by certified or experienced engineers. • Before operating the server, carefully read all the manuals included with the server package. • Before using the server, make sure all cables are correctly connected and the power cables are not damaged. If any damage is detected, contact your dealer as soon as possible. • To avoid short circuits, keep paper clips, screws, and staples away from connectors, slots, sockets and circuitry. • Avoid dust, humidity, and temperature extremes. Place the server on a stable surface. This product is equipped with a three-wire power cable and plug for the user’s safety. Use the power cable with a properly grounded electrical outlet to avoid electrical shock. Lithium-Ion Battery Warning Lithium-Ion Battery Warning Lithium-Ion Battery Warning Lithium-Ion Battery Warning Lithium-Ion Battery Warning CAUTION! CAUTION! CAUTION! CAUTION! CAUTION! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. CD-ROM Drive Safety Warning CD-ROM Drive Safety Warning CD-ROM Drive Safety Warning CD-ROM Drive Safety Warning CD-ROM Drive Safety Warning CLASS 1 LASER PRODUCT CLASS 1 LASER PRODUCT CLASS 1 LASER PRODUCT CLASS 1 LASER PRODUCT CLASS 1 LASER PRODUCT Heavy System Heavy System Heavy System Heavy System Heavy System CAUTION! CAUTION! CAUTION! CAUTION! CAUTION! This server system is heavy. Ask for assistance when moving or carrying the system.
ix ix ix ix ix About this guide Audience Audience Audience Audience Audience This user guide is intended for system integrators and experienced users with at least basic knowledge of configuring a server. Contents Contents Contents Contents Contents This guide contains the following parts: 1. 1. 1. 1. 1. Chapter 1: Product Introduction Chapter 1: Product Introduction Chapter 1: Product Introduction Chapter 1: Product Introduction Chapter 1: Product Introduction This chapter describes the general features of the server, including sections on front panel and rear panel specifications. 2. 2. 2. 2. 2. Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup This chapter lists the hardware setup procedures that you have to perform when installing or removing system components. 3. 3. 3. 3. 3. Chapter 3: Installation options Chapter 3: Installation options Chapter 3: Installation options Chapter 3: Installation options Chapter 3: Installation options This chapter describes how to install optional components into the barebone server. 4. 4. 4. 4. 4. Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information This chapter gives information about the motherboard that comes with the server. This chapter includes the motherboard layout, jumper settings, and connector locations. 5. 5. 5. 5. 5. Chapter 5: BIOS information Chapter 5: BIOS information Chapter 5: BIOS information Chapter 5: BIOS information Chapter 5: BIOS information This chapter tells how to change system settings through the BIOS Setup menus and describes the BIOS parameters. 6. 6. 6. 6. 6. Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration This chapter provides information on how toconfigure your hard disk drives as RAID sets. 7. 7. 7. 7. 7. Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation This chapter provides information on how to create a RAID set and how to install the drivers for system components. This chapter also describes the software applications that the barebone server supports. 8. 8. 8. 8. 8. Appendix: Reference information Appendix: Reference information Appendix: Reference information Appendix: Reference information Appendix: Reference information This section provides information about the power supply unit and a troubleshooting guide for solving common problems when using the barebone server.
x x x x x Reference Reference Reference Reference Reference Visit the ASUS websites worldwide that provide updated information for all ASUS hardware and software products. Refer to the ASUS contact information for details. WARNING: WARNING: WARNING: WARNING: WARNING: Information to prevent injury to yourself when trying to complete a task. CAUTION: CAUTION: CAUTION: CAUTION: CAUTION: Information to prevent damage to the components when trying to complete a task. IMPORTANT: IMPORTANT: IMPORTANT: IMPORTANT: IMPORTANT: Instructions that you MUST follow to complete a task. NOTE: NOTE: NOTE: NOTE: NOTE: Tips and information to aid in completing a task. Conventions Conventions Conventions Conventions Conventions To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual.
1-1 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 This chapter describes the general features of the barebone server, including sections on the front panel and rear panel specifications. Chapter 1 Product introduction
Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction 1-2 1-2 1-2 1-2 1-2 1.1 System package contents Check your ASUS TS300-E3 package with the items on the following table. The package contents vary for the following configurations: • PA4 PA4 PA4 PA4 P A 4 (four hot-swap Serial ATA hard disk drives) • PS4 PS4 PS4 PS4 P S 4 (four hot-swap SCSI hard disk drives) *ASUS System Web-based Management Configurations Configurations Configurations Configurations Configurations Item Description Item Description Item Description Item Description Item Description PA4 PA4 PA4 PA4 PA4 PS4 PS4 PS4 PS4 PS4 ASUS TS300-E3 5U rackmount chassis with: • ASUS P5MT motherboard • ASUS P5MT/SCSI motherboard • 450 W single power supply • SATA backplane board • SCSI backplane board • Floppy disk drive • 9 cm Blower • 12 cm Chassis fan • Hot-swap HDD trays (including HDD screws) 4 4 • Chassis roller wheels 4 4 • Front I/O board • Dummy covers Cables • AC power cable • SATA signal cables • SCSI signal cables • SMBus cable System screws and cables System keys ( 2 pcs.) Bundled CDs • TS300-E3 support CD with ASWM* • Computer Associates ® eTrust ™ anti-virus CD Documentation • ASUS TS300-E3 user guide • ASUS ASWM 2.0 user guide Optional items • 52x IDE CD-ROM or 16X DVD-ROM drive • ASUS TS300-E3 rackmount rail kit
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 1-3 1-3 1-3 1-3 1-3 1.2 System specifications The ASUS TS300-E3 is a barebone server system featuring the ASUS P5MT Series motherboard. The server supports an Intel ® Pentium ® 4/Pentium ® D processor in the 775-land package, and includes the latest technologies through the chipsets embedded on the motherboard. Chassis Chassis Chassis Chassis Chassis Motherboard Motherboard Motherboard Motherboard Motherboard Chipset Chipset Chipset Chipset Chipset Processor Processor Processor Processor Processor Front Side Bus Front Side Bus Front Side Bus Front Side Bus Front Side Bus Memory Memory Memory Memory Memory LAN LAN LAN LAN LAN Storage Storage Storage Storage Storage Pedestal or rackmount 5U with removable front door bezel and chassis foot stand or roller-wheels. ASUS P5MT (PA4 model) ASUS P5MT/SCSI (PS4 model) ATX compatible form factor: 12 in x 9.6 in Northbridge: Intel ® E7230 Memory Controller Hub (MCH) Southbridge: Intel ® ICH7R I/O Bridge: Intel ® 6702 PXH Intel ® Pentium ® 4/Intel ® Pentium ® D processor in the 775-land package with Extended Memory 64-bit Technology (EM64T) Supports Dual Core technology 1066/800/533 MHz Dual-channel memory architecture 4 x 240-pin DIMM sockets support ECC/non-ECC unbuffered 667/533 MHz DDR2 memory modules Supports 256 MB up to 8 GB of system memory Dual Broadcom ® BCM5721 Gigabit LAN controllers - PCI Express 1.0a specifications compliant For PA4 model only Intel ® ICH7R Southbridge supports: - 4 x Serial ATA 3 Gb/s hard disk drives - RAID 0, RAID 1, RAID 0 1, and RAID 5 (with limited OS support) configuration - Intel ® Matrix Storage Technology - LSI Logic Embedded SATA RAID controller (RAID 0, RAID 1, RAID 10) For PS4 model only LSI1020A PCI-X SCSI controller supports: - 1 x Ultra 320 SCSI channel with RAID 0, RAID 1, and RAID1E configuration - Zero-Channel RAID (optional) (continued on the next page)
Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction 1-4 1-4 1-4 1-4 1-4 1.2 System specifications * Only PS4 model supports Zero Channel RAID (ZCR). ** If you install a PCI Express VGA card, the link speed downgrades to x1 due to chipset limitation. This limitation applies only to VGA cards. Expansion Expansion Expansion Expansion Expansion slots slots slots slots slots Drive bays Drive bays Drive bays Drive bays Drive bays Front panel Front panel Front panel Front panel Front panel Rear panel Rear panel Rear panel Rear panel Rear panel Management Management Management Management Management Hardware Hardware Hardware Hardware Hardware monitors monitors monitors monitors monitors Power supply Power supply Power supply Power supply Power supply 1 x PCI 33 MHz/32-bit/5V (PCI 2.3) 1 x PCI-X 100 MHz/64-bit slot (PCI-X 1.0) 1 x PCI-X 100 MHz/64-bit slot (supports ZCR, PCI-X 1.0)* (colored green on PS4 model) 1 x PCI Express™ x16 slot (x8 Link)** 1 x Mini-PCI socket for the ASUS Server Management Board 1 x 3.25-inch FDD bay 3 x 5.25-inch drive bays 2 x USB 2.0 ports 1 x Serial port 1 x Parallel port 1 x PS/2 keyboard port 1 x PS/2 mouse port 2 x LAN (RJ-45) ports 2 x USB 2.0 ports 1 x VGA port ASUS Server Web-based Management (ASWM) 2.0 ASUS Server Monitoring Agent (ASMA) Voltage, temperature, CPU and memory utilization, storage capacity, and fan speed monitoring Automatic Server Restart (ASR) feature 450 W single power supply (with 24-pin and 4-pin power plugs)
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 1-5 1-5 1-5 1-5 1-5 1.3 Front panel features The TS300-E3 chassis displays a stylish front bezel with lock. The bezel covers the system components on the front panel and serves as security. Open the bezel to access the front panel components. The drive bays, power and reset buttons, LED indicators, CD-ROM drive, floppy drive, and USB 2.0 ports are located on the front panel. For future installation of 5.25-inch devices, two drive bays are available. C C C C C D-ROM drive D-ROM drive D-ROM drive D-ROM drive D-ROM drive Empty 5.25-inch bays Empty 5.25-inch bays Empty 5.25-inch bays Empty 5.25-inch bays Empty 5.25-inch bays Power button Power button Power button Power button Power button Reset button Reset button Reset button Reset button Reset button Message LED Message LED Message LED Message LED Message LED HDD access LED HDD access LED HDD access LED HDD access LED HDD access LED Power LED Power LED Power LED Power LED Power LED Floppy disk drive Floppy disk drive Floppy disk drive Floppy disk drive Floppy disk drive Security lock Security lock Security lock Security lock Security lock Drive bays Drive bays Drive bays Drive bays Drive bays USB 2.0 ports USB 2.0 ports USB 2.0 ports USB 2.0 ports USB 2.0 ports
Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction 1-6 1-6 1-6 1-6 1-6 1.4 Rear panel features The rear panel includes a slot for the motherboard rear I/O ports, expansion slots, a chassis lock and intrusion switch, a vent for the system fan, and power supply module. 12 cm system fan 12 cm system fan 12 cm system fan 12 cm system fan 12 cm system fan Chassis intrusion Chassis intrusion Chassis intrusion Chassis intrusion Chassis intrusion switch switch switch switch switch Expansion slots Expansion slots Expansion slots Expansion slots Expansion slots Gigabit LAN ports Gigabit LAN ports Gigabit LAN ports Gigabit LAN ports Gigabit LAN ports Power supply module Power supply module Power supply module Power supply module Power supply module PS/2 mouse port PS/2 mouse port PS/2 mouse port PS/2 mouse port PS/2 mouse port PS/2 keyboard port PS/2 keyboard port PS/2 keyboard port PS/2 keyboard port PS/2 keyboard port USB 2.0 ports USB 2.0 ports USB 2.0 ports USB 2.0 ports USB 2.0 ports Serial port Serial port Serial port Serial port Serial port VGA port VGA port VGA port VGA port VGA port Parallel port Parallel port Parallel port Parallel port Parallel port Power Power Power Power Power connector connector connector connector connector
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 1-7 1-7 1-7 1-7 1-7 1.5 Internal features The barebone server system includes the basic components as shown. The photo below shows the TS300-E3 with the hard disk drive blower installed. The HDD blower circulates cool air within the system. 1 1 1 1 1 1. Power supply unit 2. Chassis fan 3. ASUS P5MT motherboard 4. Chassis intrusion switch 5. Expansion card locks 6. Optical drive 7. 2 x 5.25-inch drive bays 8. HDD blower (HDD drive cage inside) 9. Front I/0 board 10. SATA backplane PA4 (4 hot-swap SATA configuration) PA4 (4 hot-swap SATA configuration) PA4 (4 hot-swap SATA configuration) PA4 (4 hot-swap SATA configuration) PA4 (4 hot-swap SATA configuration) 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8 9 9 9 9 9 10 10 10 10 10 • • • • • • • • •
Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction 1-8 1-8 1-8 1-8 1-8 1 1 1 1 1 1. Power supply unit 2. Chassis fan 3. ASUS P5MT/SCSI motherboard 4. Chassis intrusion switch 5. Expansion card locks 6. Optical drive 7. 2 x 5.25-inch drive bays 8. HDD blower (HDD drive cage inside) 9. Front I/0 board 10. SCSI backplane PS4 (4 hot-swap SCSI configuration) PS4 (4 hot-swap SCSI configuration) PS4 (4 hot-swap SCSI configuration) PS4 (4 hot-swap SCSI configuration) PS4 (4 hot-swap SCSI configuration) 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6 6 6 6 6 7 7 7 7 7 8 8 8 8 8 9 9 9 9 9 10 10 10 10 10 • • • • • • • • •
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 1-9 1-9 1-9 1-9 1-9 1.6 LED information The barebone system comes with five LED indicators. Refer to the following table for the LED status description. System and HDD LED System and HDD LED System and HDD LED System and HDD LED System and HDD LED *SCSI Access Fault-Tolerant Enclosure (on PS4 model only) ! Power LED (blue) Power LED (blue) Power LED (blue) Power LED (blue) Power LED (blue) HDD Access LED (green) HDD Access LED (green) HDD Access LED (green) HDD Access LED (green) HDD Access LED (green) Message LED (red) Message LED (red) Message LED (red) Message LED (red) Message LED (red) Drive Status LED (green/red) Drive Status LED (green/red) Drive Status LED (green/red) Drive Status LED (green/red) Drive Status LED (green/red) Drive Activity LED (green) Drive Activity LED (green) Drive Activity LED (green) Drive Activity LED (green) Drive Activity LED (green) LED LED LED LED LED Icon Icon Icon Icon Icon Display status Display status Display status Display status Display status Description Description Description Description Description System System System System System Power LED ON System power ON Blinking System is in suspend mode HDD Access LED OFF No activity Blinking Read/write data into the HDD Message LED OFF System is normal; no incoming event Blinking ASMS indicates a HW monitor event Hard disk drives Hard disk drives Hard disk drives Hard disk drives Hard disk drives Drive Status LED Green Bridge board connected to backplane Installed HDD is in good condition Red HDD failure Green/Red - Blinking HDD rebuilding using the RAID card SAF-TE* function Drive Activity LED Blinking Read/write data into the HDD ! The Power, HDD Access, and Message LEDs are visible even if the system front bezel is closed.
Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction Chapter 1: Product introduction 1-10 1-10 1-10 1-10 1-10
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2-1 This chapter lists the hardware setup procedures that you have to perform when installing or removing system components. Chapter 2 Hardware setup
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-2 2-2 2-2 2-2 2-2 2.1 Chassis cover The chassis features a “screwless design” that allows convenient assembly and disassembly. You can simply push or slide mechanical bolts and locks to remove the cover. 2.1.1 2.1.1 2.1.1 2.1.1 2.1.1 Removing the side cover Removing the side cover Removing the side cover Removing the side cover Removing the side cover 1. Remove the two screws that secure the cover to the chassis. 2. Slide the side cover for about half an inch toward the rear until it is disengaged from the chassis. 3. Carefully lift the cover and set it aside. Viewing the internal structure Viewing the internal structure Viewing the internal structure Viewing the internal structure Viewing the internal structure Without the side cover, the internal structure and installed components of the barebone server vary depending on the model you purchased. Refer to section “1.5 Internal features” for the different model configurations. Perform the procedures in the succeeding sections to install the CPU, system memory, disk drives, and expansion cards; replace fans and power supply; and connect the system cables. 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2
2-3 2-3 2-3 2-3 2-3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2.1.2 2.1.2 2.1.2 2.1.2 2.1.2 Reinstalling the side cover Reinstalling the side cover Reinstalling the side cover Reinstalling the side cover Reinstalling the side cover To reinstall the side cover: 1. Match and insert the upper hooks and lower sliding edge of the cover to the corresponding chassis holes and edge. 2. Slide the cover toward the front until it snaps in place. You may need to remove some of the installed components to access the DIMM sockets and internal connectors. Refer to section “2.10 Removable components” for instructions. 3. Drive in the two screws you removed earlier to secure the side cover. 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-4 2-4 2-4 2-4 2-4 2.2 Motherboard overview The barebone server comes with the P5MT (PA4 model) or P5MT/SCSI (PS4 model) motherboard already installed. The motherboard is secured to the chassis by nine (9) screws as indicated by the circles in the illustration below. Make sure to unplug the power cord before installing or removing any motherboard component or connection. Failure to do so can cause you physical injury and damage motherboard components. LAN2 ® Place this side towards Place this side towards Place this side towards Place this side towards Place this side towards the rear of the chassis the rear of the chassis the rear of the chassis the rear of the chassis the rear of the chassis Refer to “Chapter 4 Motherboard information” for detailed information on the motherboard.
2-5 2-5 2-5 2-5 2-5 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2.3.1 2.3.1 2.3.1 2.3.1 2.3.1 Installing the CPU Installing the CPU Installing the CPU Installing the CPU Installing the CPU To install a CPU: 1. Locate the CPU socket on the motherboard. 2.3 Central Processing Unit (CPU) The motherboard comes with a surface mount LGA775 socket designed for the Intel ® Pentium ® 4 processor in the 775-land package Before installing the CPU, make sure that the cam box is facing towards you and the load lever is on your left. LAN2 ® P5MT Series CPU Socket 775 2. Press the load lever with your thumb (A), then move it to the left (B) until it is released from the retention tab. Retention tab Retention tab Retention tab Retention tab Retention tab Load lever Load lever Load lever Load lever Load lever This side of the This side of the This side of the This side of the This side of the socket box should socket box should socket box should socket box should socket box should face you. face you. face you. face you. face you. PnP cap PnP cap PnP cap PnP cap PnP cap A B To prevent damage to the socket pins, do not remove the PnP cap unless you are installing a CPU.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-6 2-6 2-6 2-6 2-6 3. Lift the load lever in the direction of the arrow to a 135º angle. 4. Lift the load plate with your thumb and forefinger to a 100º angle (A), then push the PnP cap from the load plate window to remove (B). 5. Position the CPU over the socket, making sure that the gold triangle is on the bottom-left corner of the socket. The socket alignment key should fit into the CPU notch. Alignment key Alignment key Alignment key Alignment key Alignment key Gold triangle mark Gold triangle mark Gold triangle mark Gold triangle mark Gold triangle mark Load plate Load plate Load plate Load plate Load plate A B
2-7 2-7 2-7 2-7 2-7 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 The CPU fits in only one correct orientation. DO NOT force the CPU into the socket to prevent bending the connectors on the socket and damaging the CPU! 6. Close the load plate (A), then push the load lever (B) until it snaps into the retention tab. A B The motherboard supports Intel ® Pentium ® 4 LGA775 processors with the Intel ® Enhanced Memory 64 Technology (EM64T), Enhanced Intel SpeedStep ® Technology (EIST), and Hyper-Threading Technology. Refer to the Appendix for more information on these CPU features.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-8 2-8 2-8 2-8 2-8 2.3.2 2.3.2 2.3.2 2.3.2 2.3.2 Installing the CPU heatsink and airduct Installing the CPU heatsink and airduct Installing the CPU heatsink and airduct Installing the CPU heatsink and airduct Installing the CPU heatsink and airduct assembly assembly assembly assembly assembly The TS300-E3 comes with a proprietary CPU heatsink and airduct, which come in separate boxes when you receive the package. You have to assemble the CPU heatsink and airduct before installing to the motherboard. To assemble the CPU heatsink and airduct: 1. Align the airduct pegs to the fan and heatsink holes. 2. Push down the airduct into the holes to secure the assembly. To install the CPU heatsink and airduct assembly: 1. Locate the four screw holes on the motherboard.
2-9 2-9 2-9 2-9 2-9 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2. Position the CPU heatsink and airduct assembly on top of the installed CPU, making sure that the heatsink screws match the screw holes on the motherboard. 3. Drive the four screws into the holes in a diagonal sequence to secure the heatsink and airduct assembly to the motherboard. A A B B 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4. Connect the CPU fan cable to the connector on the motherboard labeled CPU_FAN1. Do not forget to connect the CPU fan connector! Hardware monitoring errors can occur if you fail to plug the connector. LAN2 ¤ P5MT Series CPU fan connector CPU_F AN 1 GND F ANPWR2 F ANOUT4 CPU_F AN1
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-10 2-10 2-10 2-10 2-10 2.4 System memory 2.4.1 2.4.1 2.4.1 2.4.1 2.4.1 Overview Overview Overview Overview Overview The motherboard comes with four Double Data Rate II (DDR2) Dual Inline Memory Modules (DIMM) sockets to support 240-pin DDR modules. The figure illustrates the location of the DDR DIMM sockets: 2.4.2 2.4.2 2.4.2 2.4.2 2.4.2 Memory configurations Memory configurations Memory configurations Memory configurations Memory configurations You may install 256 MB, 512 MB, 1 GB, and 2 GB unbuffered ECC or non-ECC DDR2-533/667 DIMMs into the DIMM sockets. • Always install DIMMs with the same CAS latency. For optimum compatibility, it is recommended that you obtain memory modules from the same vendor. Refer to the DDR2 Qualified Vendors List at the ASUS web site. • When installing one or two DIMMs, install the DIMM(s) to the blue slots (DIMM_A2/DIMM_B2). • Three DDR DIMMs intalled into any three memory sockets will function in single-channel mode. LAN2 ® P5MT Series 240-pin DDR2 DIMM sockets DIMM_A1 DIMM_B2 DIMM_B1 DIMM_A2 1 12 Pins 128 Pins
2-11 2-11 2-11 2-11 2-11 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2.4.3 2.4.3 2.4.3 2.4.3 2.4.3 Installing a DIMM Installing a DIMM Installing a DIMM Installing a DIMM Installing a DIMM Unplug the power supply before adding or removing DIMMs or other system components. Failure to do so can cause severe damage to both the motherboard and the components. To install a DIMM: 1. Unlock a DIMM socket by pressing the retaining clips outward. 2. Align a DIMM on the socket such that the notch on the DIMM matches the break on the socket. 3. Firmly insert the DIMM into the socket until the retaining clips snap back in place and the DIMM is properly seated. 2.4.4 2.4.4 2.4.4 2.4.4 2.4.4 Removing a DIMM Removing a DIMM Removing a DIMM Removing a DIMM Removing a DIMM To remove a DIMM: 1. Simultaneously press the retaining clips outward to unlock the DIMM. 2. Remove the DIMM from the socket. • A DDR2 DIMM is keyed with a notch so that it fits in only one direction. Do not force a DIMM into a socket to avoid damaging the DIMM. • The DDR2 DIMM sockets do not support DDR DIMMs. DO not install DDR DIMMs to the DDR2 DIMM sockets. Unlocked retaining clip Unlocked retaining clip Unlocked retaining clip Unlocked retaining clip Unlocked retaining clip DDR2 DIMM notch DDR2 DIMM notch DDR2 DIMM notch DDR2 DIMM notch DDR2 DIMM notch Support the DIMM lightly with your fingers when pressing the retaining clips. The DIMM might get damaged when it flips out with extra force. DDR2 DIMM notch DDR2 DIMM notch DDR2 DIMM notch DDR2 DIMM notch DDR2 DIMM notch 1 2 3 1 2 1
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-12 2-12 2-12 2-12 2-12 Before you can install a 5.25-inch drive, you should first remove the front panel assembly (front bezel and front panel cover). The front panel assembly is attached to the chassis through three hooked tabs hooked tabs hooked tabs hooked tabs hooked tabs o n t h e left side and four hinge-like tabs hinge-like tabs hinge-like tabs hinge-like tabs hinge-like tabs o n the right side. To remove the front panel assembly: 1. Locate the four hooked tabs on the chassis side rail. 2. Press each lock tab to release the front panel from the chassis. 2.5 Front panel assembly 2.5.1 2.5.1 2.5.1 2.5.1 2.5.1 Removing the front panel assembly Removing the front panel assembly Removing the front panel assembly Removing the front panel assembly Removing the front panel assembly 3. Pull and swing the left edge of the front panel outward.
2-13 2-13 2-13 2-13 2-13 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 Do not use too much force when removing the front panel assembly. 4. Unhook the hinge-like tabs from the holes on the right side of the front panel to completely detach the front panel assembly from the chassis. Hinge-like tab Hinge-like tab Hinge-like tab Hinge-like tab Hinge-like tab
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-14 2-14 2-14 2-14 2-14 2.5.2 2.5.2 2.5.2 2.5.2 2.5.2 Reinstalling the front panel assembly Reinstalling the front panel assembly Reinstalling the front panel assembly Reinstalling the front panel assembly Reinstalling the front panel assembly To reinstall the front panel assembly (front bezel and front panel cover): 1. Insert the four hinge-like tabs to the holes on the right edge of the chassis. 2. Swing the front panel to the left and fit the four (4) hooked tabs to the left side of the chassis until the tabs snap back in place. Hinge-like tab Hinge-like tab Hinge-like tab Hinge-like tab Hinge-like tab 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2
2-15 2-15 2-15 2-15 2-15 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2.6 5.25-inch drives Three 5.25-inch drive bays are located on the upper front part of the chassis. A CD-ROM drive that comes standard with the system package occupies the uppermost bay (labeled 1) . The two lower bays (labeled 2 and 3) are available for additional 5.25-inch devices. If you have previously used and powered up the system, and that it may be connected to an AC power source, make sure to unplug the power cable before installing or removing any system components. Failure to do so may cause damage to the motherboard and other system components! To install a 5.25-inch drive: 1. Use a Phillips (cross) screwdriver to remove the screws that secure the metal cover of the bay where you want to install the drive. 2. Insert the optical drive into the 5.25-inch drive bay. 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-16 2-16 2-16 2-16 2-16 5. Connect the IDE cable to the IDE connector on the back of the drive. 6. Connect a 4-pin plug from the power supply to the power connector on the back of the drive. IDE cable IDE cable IDE cable IDE cable IDE cable Power plug Power plug Power plug Power plug Power plug 3. Make sure that the drive and bay hole align as shown. When in place, the drive protrudes about an inch from the front panel. 4. Secure the drive with a screw.
2-17 2-17 2-17 2-17 2-17 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 7. On the front panel assembly, detach the plastic bay cover opposite the 5.25-inch drive that you installed by pressing the two hooked tabs on each side of the bay cover. 8. Reinstall the front panel assembly when done. Refer to section “2.5.2 Reinstalling the front panel assembly” for instructions.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-18 2-18 2-18 2-18 2-18 2.7 Hard disk drives 2.7.1 2.7.1 2.7.1 2.7.1 2.7.1 Installing a hot-swap SATA/SCSI HDD Installing a hot-swap SATA/SCSI HDD Installing a hot-swap SATA/SCSI HDD Installing a hot-swap SATA/SCSI HDD Installing a hot-swap SATA/SCSI HDD Follow the instructions in this section to install a hot-swap SATA (PA4 model) or SCSI (PS4 model) hard disk drive (HDD). 1. Open the front bezel to access the hot-swap drive trays. 2. Release a drive tray by pushing the spring lock to the right, then pulling the tray lever outward. The drive tray ejects slightly after you pull out the lever. 3. Firmly hold the tray lever and pull the drive tray out of the bay. 4. An empty drive tray requires a metal bracket for support. Use a Phillips (cross) screwdriver to remove the bracket when you are ready to install a hard disk in the drive tray. Metal bracket Metal bracket Metal bracket Metal bracket Metal bracket Tray lever Tray lever Tray lever Tray lever Tray lever Spring lock Spring lock Spring lock Spring lock Spring lock
2-19 2-19 2-19 2-19 2-19 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5. Place a SA T A or an SCA SCSI hard disk to the drive tray , and secure it with four screws. 6. Carefully insert drive tray and push it all the way to the depth of the bay until just a small fraction of the tray edge protrudes. 7. Push the tray lever until it clicks, and secures the drive tray in place. The drive tray is correctly placed when its front edge aligns with the bay edge.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-20 2-20 2-20 2-20 2-20 2. Press the dummy cover into the slot opening until the hook tab clicks in place. 3. When installed, the dummy cover appears as shown. 2.7.2 2.7.2 2.7.2 2.7.2 2.7.2 Installing an HDD dummy cover Installing an HDD dummy cover Installing an HDD dummy cover Installing an HDD dummy cover Installing an HDD dummy cover The HDD dummy covers come pre-installed on the front panel bezel. In case you removed the covers, follow these steps to re-install them. To install an HDD dummy cover: 1. From the inside of the front panel assembly, insert the flat end of a dummy cover into the slot as shown. The end with the hook tab should be close to the front panel LEDs. Flat end Hook tab
2-21 2-21 2-21 2-21 2-21 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2.8 Expansion cards Refer to this section when installing expansion cards. Make sure to unplug the power cord before installing or removing expansion cards. Failure to do so may cause physical injury, and damage to the card and motheboard components! 2.8.1 2.8.1 2.8.1 2.8.1 2.8.1 Installing an expansion card Installing an expansion card Installing an expansion card Installing an expansion card Installing an expansion card To install an expansion card: 1. Lay the chassis on its side. 2. Locate the metal bracket opposite the slot you want to use. Remove the screw that secures the metal bracket to the chassis. Set aside the metal bracket for future use. 3. Align the card golden fingers to the slot and its metal bracket to the slot opening on the chassis. 4. Press the card firmly until it is properly seated on the slot. 5. Secure the card to the chassis with the bracket screw you removed earlier.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-22 2-22 2-22 2-22 2-22 2.8.2 2.8.2 2.8.2 2.8.2 2.8.2 Removing an expansion card Removing an expansion card Removing an expansion card Removing an expansion card Removing an expansion card To remove an expansion card: 1. Remove the screw that secures the card to the chassis. 2. Carefully remove the card from the slot. 3. Reinstall the metal bracket and secure it to the chassis with the screw that you removed earlier.
2-23 2-23 2-23 2-23 2-23 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2.9 Cable connections • The bundled system cables are pre-connected before shipment. You do not need to disconnect these cables unless you will remove pre-installed components to install additional devices. • Refer to Chapter 4 for detailed information on the connectors. Standard cables connected to the motherboard Standard cables connected to the motherboard Standard cables connected to the motherboard Standard cables connected to the motherboard Standard cables connected to the motherboard 7. Serial port (COM2) 8. Auxiliary panel cable 9. Front USB cable 10. Front panel cable 11. Floppy disk drive 12. Primary IDE cable 13. SCSI connector (for PS4 Model only) 1. 24-pin ATX power 2. 4-pin 12V power 3. CPU fan 1/2 4. Rear fan 1/2 5. Front fan 1/2 6. Serial ATA connectors P5MT/SCSI 8Mbit Flash BIOS Super I/O PRI_IDE1 25cm (9.8in) 30.5cm (12in) DDR2 DIMM_A1 (64 bit,240-pin module) DDR2 DIMM_B1 (64 bit,240-pin module) DDR2 DIMM_A2 (64 bit,240-pin module) DDR2 DIMM_B2 (64 bit,240-pin module) S ATA 1 AT I RAGE XL VGA Controller AUX_P ANEL1 KBPWR1 PSUSMB1 CR2032 3V Lithium Cell CMOS Po wer PS/2KBMS T : Mouse B: Keyboard LAN1 LAN2 ® USB12 COM1 P ARALLEL PORT VGA1 USBPW12 REAR_FAN1 A TX12V1 FM_CPU2 CPU_FAN2 FM_CPU1 CPU_FAN1 PCIE1 PCIX3 PCIX2 FRNT_FAN1 FRNT_FAN2 SCSIA1 S ATA 2 S ATA 3 S ATA 4 P ANEL1 RECOVERY1 USB34 USBPW34 HDLED1 BUZZ1 FLOPPY1 BMCCONN1 TRPWR1 CLRTC1 BPSMB1 VGA_EN1 SB_PWR1 COM2 LAN_EN2 LAN_EN1 Broadcom BCM5721 Broadcom BCM5721 LSI 1020A Intel E7230 Intel 6702 PXH Inte l ICH7R BMCSOCKET1 LAN2 LGA775 PCI4 SCSI_EN1 A TXPWR1 REAR_FAN2 RAID_SEL1 1 1 1 1 1 12 12 12 12 12 11 11 11 11 11 6 6 6 6 6 10 10 10 10 10 9 9 9 9 9 5 5 5 5 5 3 3 3 3 3 8 8 8 8 8 7 7 7 7 7 5 5 5 5 5 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 13 13 13 13 13 2.9.1 2.9.1 2.9.1 2.9.1 2.9.1 Motherboard connections Motherboard connections Motherboard connections Motherboard connections Motherboard connections
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-24 2-24 2-24 2-24 2-24 2.9.2 2.9.2 2.9.2 2.9.2 2.9.2 SATA backplane connections SATA backplane connections SATA backplane connections SATA backplane connections SATA backplane connections (in PA4 model only) (in PA4 model only) (in PA4 model only) (in PA4 model only) (in PA4 model only) A SATA backplane comes pre-installed in the TS300-E3 PA4 model. The SATA backplane has four 15-pin SATA connectors to support Serial ATA hard disk drives. The backplane design incorporates a hot swap feature to allow easy connection or removal of SATA hard disks. The LED on the backplane connect to the front panel LED to indicate HDD status. See section “1.6 LED information” for details. Front side Front side Front side Front side Front side The front side of the SATA backplane faces the front panel when installed. This side includes four SATA connectors for the hot swap drive trays. Drive status LEDs Drive status LEDs Drive status LEDs Drive status LEDs Drive status LEDs CON1 CON1 CON1 CON1 CON1 CON3 CON3 CON3 CON3 CON3 CON5 CON5 CON5 CON5 CON5 CON7 CON7 CON7 CON7 CON7 Each SATA connector is labeled (CON1, CON3, CON5, CON7) so you can easily determine their counterpart connectors at the back side of the backplane. Refer to the table for reference. HDD HDD HDD HDD HDD Front side Front side Front side Front side Front side Back side Back side Back side Back side Back side Device Device Device Device Device connector connector connector connector connector connector connector connector connector connector HDD 1 CON1 CON2 HDD 2 CON3 CON4 HDD 3 CON5 CON6 HDD 4 CON7 CON8
2-25 2-25 2-25 2-25 2-25 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 Back side Back side Back side Back side Back side The back side of SATA backplane faces the rear panel when installed. This side includes the power connectors, SATA interfaces for the motherboard Serial ATA connectors or the SATA/RAID card, an HDD fan connector, and SMBus connectors. Fan connector Fan connector Fan connector Fan connector Fan connector (for HDD fan) (for HDD fan) (for HDD fan) (for HDD fan) (for HDD fan) Power connectors Power connectors Power connectors Power connectors Power connectors (connect power (connect power (connect power (connect power (connect power plugs from the plugs from the plugs from the plugs from the plugs from the power supply) power supply) power supply) power supply) power supply) The back side SATA connectors are attached to the motherboard SATA connectors via the supplied SATA cables. Refer to the illustration below for the location of the SATA connectors. Refer to the table on the right for the default SATA cable connections. CON2 CON2 CON2 CON2 CON2 CON4 CON4 CON4 CON4 CON4 CON6 CON6 CON6 CON6 CON6 CON8 CON8 CON8 CON8 CON8 Backplane Backplane Backplane Backplane Backplane Connected to Connected to Connected to Connected to Connected to Controlled Controlled Controlled Controlled Controlled ID ID ID ID ID (on (on (on (on (on motherboard) motherboard) motherboard) motherboard) motherboard) by by by by by CON2 SATA1 Intel ® ICH7R CON4 SATA2 Intel ® ICH7R CON6 SATA3 Intel ® ICH7R CON8 SATA4 Intel ® ICH7R Upper 6-1 pins: SMBus connector Upper 6-1 pins: SMBus connector Upper 6-1 pins: SMBus connector Upper 6-1 pins: SMBus connector Upper 6-1 pins: SMBus connector (connects the SMB cable from the BPSMB1 (connects the SMB cable from the BPSMB1 (connects the SMB cable from the BPSMB1 (connects the SMB cable from the BPSMB1 (connects the SMB cable from the BPSMB1 connector on the motherboard) connector on the motherboard) connector on the motherboard) connector on the motherboard) connector on the motherboard) SATA2 SATA2 SATA2 SATA2 SATA2 SATA RAID controller SATA RAID controller SATA RAID controller SATA RAID controller SATA RAID controller P5MT 8Mbit Flash BIOS Super I/O PRI_IDE1 25cm (9.8in) 30.5cm (12in) DDR2 DIMM_A1 (64 bit,240-pin module) DDR2 DIMM_B1 (64 bit,240-pin module) DDR2 DIMM_A2 (64 bit,240-pin module) DDR2 DIMM_B2 (64 bit,240-pin module) SATA 1 ATI RAGE XL VGA Controller AUX_PANEL1 KBPWR1 PS/2KBMS T: Mouse B: Keyboard LAN1 LAN2 ® USB12 COM1 PARALLEL PORT VGA1 PCIE1 PCIX3 PCIX2 FRNT_FAN1 FRNT_FAN2 SATA 2 SATA 3 SATA 4 PANEL1 RECOVERY1 USB34 USBPW34 HDLED1 BUZZ1 FLOPPY1 BMCCONN1 TRPWR1 BPSMB1 VGA_EN1 SB_PWR1 COM2 LAN_EN2 LAN_EN1 Broadcom BCM5721 Broadcom BCM5721 Intel E7230 Intel 6702 PXH Intel ICH7R BMCSOCKET1 LAN2 LGA775 PCI4 PSUSMB1 CR2032 3V Lithium Cell CMOS Power USBPW12 REAR_FAN1 ATX12V1 FM_CPU2 CPU_FAN2 FM_CPU1 CPU_FAN1 CLRTC1 A TXPWR1 REAR_FAN2 RAID_SEL1 SATA4 SATA4 SATA4 SATA4 SATA4 SATA1 SATA1 SATA1 SATA1 SATA1 SATA3 SATA3 SATA3 SATA3 SATA3
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-26 2-26 2-26 2-26 2-26 SATA backplane jumper settings and HDD ID assignments SATA backplane jumper settings and HDD ID assignments SATA backplane jumper settings and HDD ID assignments SATA backplane jumper settings and HDD ID assignments SATA backplane jumper settings and HDD ID assignments The 6-pin jumper J3 J3 J3 J3 J 3 allows you to define your desired SATA configuration. The picture below shows the location of jumper J3 with pins 1-3 and 2-4 shorted. Refer to the table for the jumper settings and the appropriate ID# for each SATA HDD bay. J3 setting J3 setting J3 setting J3 setting J3 setting (1-3 shorted, 2-4 shorted) Device Device Device Device Device SATA ID # SATA ID # SATA ID # SATA ID # SATA ID # Drive Bay 1 ID0 Drive Bay 2 ID1 Drive Bay 3 ID2 Drive Bay 4 ID3
2-27 2-27 2-27 2-27 2-27 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2.9.3 2.9.3 2.9.3 2.9.3 2.9.3 SCSI backplane connections SCSI backplane connections SCSI backplane connections SCSI backplane connections SCSI backplane connections (in PS4 model only) (in PS4 model only) (in PS4 model only) (in PS4 model only) (in PS4 model only) A SCSI backplane comes pre-installed in the TS300-E3 PS4 model. The SCSI backplane has four 68-pin SCSI connectors to support SCA SCSI hard disks. The backplane design incorporates a hot swap feature to allow easy connection or removal of SCSI hard disks. The LEDs on the backplane connect to the front panel LEDs to indicate HDD access, HDD failure, thermal failure, or fan failure. See section “1.6 LED information.” Front side Front side Front side Front side Front side The front side of the SCSI backplane faces the front panel when installed. This side includes four SCSI connectors for the hot swap drive trays. HDD status LEDs HDD status LEDs HDD status LEDs HDD status LEDs HDD status LEDs HDD activity LEDs HDD activity LEDs HDD activity LEDs HDD activity LEDs HDD activity LEDs Disk drive 1 Disk drive 1 Disk drive 1 Disk drive 1 Disk drive 1 Disk drive 2 Disk drive 2 Disk drive 2 Disk drive 2 Disk drive 2 Disk drive 3 Disk drive 3 Disk drive 3 Disk drive 3 Disk drive 3 Disk drive 4 Disk drive 4 Disk drive 4 Disk drive 4 Disk drive 4
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-28 2-28 2-28 2-28 2-28 Back side Back side Back side Back side Back side The back side of SCSI backplane faces the rear panel when installed. This side includes the power connectors, SCSI interfaces for the motherboard SCSI connector or the SCSI/RAID card and terminator, an HDD fan connector, and SMBus connectors. • the upper SCSI interface of the backplane connects to the motherboard SCSI connector or the SCSI/RAID card • a SCSI multi-mode terminator (LVD/SE) is connected to the lower SCSI interface of the backplane 68-pin SCSI connector 68-pin SCSI connector 68-pin SCSI connector 68-pin SCSI connector 68-pin SCSI connector (connects the SCSI cable from (connects the SCSI cable from (connects the SCSI cable from (connects the SCSI cable from (connects the SCSI cable from the the the the the motherboard SCSI connector or motherboard SCSI connector or motherboard SCSI connector or motherboard SCSI connector or motherboard SCSI connector or the SCSI/RAID card) the SCSI/RAID card) the SCSI/RAID card) the SCSI/RAID card) the SCSI/RAID card) SMBus connector SMBus connector SMBus connector SMBus connector SMBus connector [SMB_IN1] (connects the SMB cable [SMB_IN1] (connects the SMB cable [SMB_IN1] (connects the SMB cable [SMB_IN1] (connects the SMB cable [SMB_IN1] (connects the SMB cable from the motherboard) from the motherboard) from the motherboard) from the motherboard) from the motherboard) Fan connector Fan connector Fan connector Fan connector Fan connector (for HDD fan) (for HDD fan) (for HDD fan) (for HDD fan) (for HDD fan) Power connectors Power connectors Power connectors Power connectors Power connectors (connect power (connect power (connect power (connect power (connect power plugs from the power supply) plugs from the power supply) plugs from the power supply) plugs from the power supply) plugs from the power supply) 68-pin SCSI connector 68-pin SCSI connector 68-pin SCSI connector 68-pin SCSI connector 68-pin SCSI connector (with SCSI multi-mode terminator) (with SCSI multi-mode terminator) (with SCSI multi-mode terminator) (with SCSI multi-mode terminator) (with SCSI multi-mode terminator)
2-29 2-29 2-29 2-29 2-29 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 Refer to the following tables for the jumper settings and the appropriate ID# for each SCSI HDD bay. SCSI backplane jumper settings and HDD ID assignments SCSI backplane jumper settings and HDD ID assignments SCSI backplane jumper settings and HDD ID assignments SCSI backplane jumper settings and HDD ID assignments SCSI backplane jumper settings and HDD ID assignments The 6-pin jumper J1 J1 J1 J1 J 1 on each of the SCSI backplanes allows you to define your desired SCSI configuration. The picture below shows the location of jumper J1 with pins 1-3 and 2-4 shorted. J1 setting J1 setting J1 setting J1 setting J1 setting (1-3 shorted, 2-4 shorted) Device Device Device Device Device SCSI ID# SCSI ID# SCSI ID# SCSI ID# SCSI ID# Drive Bay 1 ID0 Drive Bay 2 ID1 Drive Bay 3 ID2 Drive Bay 4 ID3 GEM SAF-TE ID15 (SCSI channel-0)
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-30 2-30 2-30 2-30 2-30 2.10.1 2.10.1 2.10.1 2.10.1 2.10.1 Chassis fan Chassis fan Chassis fan Chassis fan Chassis fan To remove the chassis fan: 1. Unplug the chassis fan cable fron the REAR_FAN1 connector on the motherboard. 2.10 Removable components You may need to remove previously installed system components when installing or removing system devices, or when you need to replace defective components. This section tells how to remove the following components: 1. Chassis fan 2. HDD blowers 3. SATA/SCSI backplanes 4. Floppy disk drive module 5. Front I/O board 6. Chassis footpads and roller wheels 7. Power supply unit 2. Locate the four screws that secure the fan to the chassis. 3. Remove the four screws while carefully supporting the chassis fan with your free hand to prevent it from falling off. Set the screws aside. 4. Carefully remove the chassis fan.
2-31 2-31 2-31 2-31 2-31 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 1. Align the chassis fan holes to the screw holes on the chassis. 2. Drive in the four screws you removed earlier to secure the fan to the chassis. 5. Remove the four screws that secure the metal shroud to the fan. Set the screws aside. To reinstall the chassis fan: 1. Drive in the four screws you removed earlier into the fan screw holes to secure the metal shroud to the fan.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-32 2-32 2-32 2-32 2-32 2.10.2 2.10.2 2.10.2 2.10.2 2.10.2 HDD blower HDD blower HDD blower HDD blower HDD blower To remove the HDD blower: 1. Remove the side cover. Refer to section “2.1.1 Removing the side cover” for instructions. 2. Disconnect the 3-pin fan cable from the fan connector on the backplane. 3 3 3 3 3 4. Firmly grip the blower case as shown, then slide it out of the chassis in the direction of the arrow until the tabs are released from the holes of the HDD cage. 3. Loosen the thumb screw that secures the HDD blower case to the chassis. 3. Plug the chassis fan cable to the connector on the motherboard.
2-33 2-33 2-33 2-33 2-33 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6. Remove the blower from the case. To reinstall the HDD blower: 1. Replace the blower into the case. 2. Secure the blower to the case with the two screws you removed earlier. 5. Remove the two screws on the blower case using a Phillips screwdriver. Set the screws aside.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-34 2-34 2-34 2-34 2-34 4. Drive in the thumb screw to secure the HDD blower case. 5. Connect the 3-pin fan cable to the fan connector on the backplane. 3. Slide in the blower case as shown, making sure the tabs fit into the holes on the HDD cage.
2-35 2-35 2-35 2-35 2-35 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2.10.3 2.10.3 2.10.3 2.10.3 2.10.3 SATA/SCSI backplane SATA/SCSI backplane SATA/SCSI backplane SATA/SCSI backplane SATA/SCSI backplane To remove the SATA/SCSI backplane: 1. Remove the HDD blower case. Refer to section “2.10.2 HDD blowers” for instructions. 2. Disconnect all cables from the SATA/SCSI backplane. When disconnecting a cable, hold and firmly pull the cable plug. DO NOT pull the cable itself. Doing so may damage the cable! 3. From the inner edge, push the backplane outward so that the outer edge protrudes slightly from the slot. 4. From the outer edge, firmly hold the backplane and carefully slide it out.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-36 2-36 2-36 2-36 2-36 T o reinstall a SA T A/SCSI backplane: 1. Position the backplane into its slot with the component side facing the rear panel, and the power connectors on top. 2. Align the backplane with the rail-like dents on the slot to ensure that it fits securely. 3. Slide the backplane into the slot until it fits. If correctly installed, the outer edge of the backplane aligns with the corner of the drive cage. 4. Connect the appropriate cables to the backplane. Refer to sections “2.9.2 SATA backplane connections” and “2.9.3 SCSI backplane connections” for details. Rail-like dents Rail-like dents Rail-like dents Rail-like dents Rail-like dents
2-37 2-37 2-37 2-37 2-37 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2.10.4 2.10.4 2.10.4 2.10.4 2.10.4 Floppy disk drive Floppy disk drive Floppy disk drive Floppy disk drive Floppy disk drive 2. Carefully pull out the drive from the chassis until you see the cables connected to the drive. To remove the floppy disk drive: 1. Remove the screw that secures the drive to the chassis. You need to remove the front panel assembly before you can remove the floppy disk drive. Refer to section “2.5.1 Removing the front panel assembly” for instructions. 3. Disconnect the floppy disk cable and power cable from the drive to completely release the drive.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-38 2-38 2-38 2-38 2-38 To install a floppy disk drive: 1. Position the floppy drive vertically with the eject button on the left side (close to the HDDs). 2. Connect the drive signal cable and power cable. 4. Secure the drive cage with a screw. 3. Carefully push the drive into the bay until the drive cage fits the front edge of the bay. Floppy drive power cable Floppy drive power cable Floppy drive power cable Floppy drive power cable Floppy drive power cable Floppy drive signal cable Floppy drive signal cable Floppy drive signal cable Floppy drive signal cable Floppy drive signal cable Red stripe to match Pin 1 on Red stripe to match Pin 1 on Red stripe to match Pin 1 on Red stripe to match Pin 1 on Red stripe to match Pin 1 on the connector the connector the connector the connector the connector
2-39 2-39 2-39 2-39 2-39 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2.10.5 2.10.5 2.10.5 2.10.5 2.10.5 Front I/O board Front I/O board Front I/O board Front I/O board Front I/O board You need to remove the front panel assembly before you can remove the front I/O board. Refer to section “2.5.1 Removing the front panel assembly” for instructions. To remove the front I/O board: 1. Remove the screw that secures the front I/O board bracket to the front panel. 4. Remove the screw that secures the I/O board to the bracket. 2. Carefully pull out the bracket until you see the cables connected to the I/O board. 3. Disconnect all the cables from the I/O board.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-40 2-40 2-40 2-40 2-40 To install the front I/O board: 1. Place the I/O board in the bracket, component side up. Secure the front I/O board to the bracket with a screw. 2. Position the I/O board into the bay with the component side to the left (close to the HDDs). Connect the I/O cables to the connectors on the back of the I/O board. 3. Insert the I/O board into the bay until the bracket fits the front edge of the bay. 4. Secure the I/O board bracket with a screw. USB 2.0 connector USB 2.0 connector USB 2.0 connector USB 2.0 connector USB 2.0 connector
2-41 2-41 2-41 2-41 2-41 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2.10.6 2.10.6 2.10.6 2.10.6 2.10.6 Chassis footpads and roller wheels Chassis footpads and roller wheels Chassis footpads and roller wheels Chassis footpads and roller wheels Chassis footpads and roller wheels The barebone server system is shipped with four footpads attached to the bottom of the chassis for stability. You need to remove these footpads if: • if you want to replace the footpads with the bundled roller wheels • you wish to install the system to a rack (Refer to “Chapter 3 Installation options” of this user guide, and to the “Rackmount Kit” user guide for instructions) To remove the footpads: 1. Lay the system chassis on its side. 2. Use a flat screwdriver to flip out the top layer of a footpad. 4. Repeat steps 2 and 3 to remove the other three footpads. 3. Remove the footpad by rotating it counterclockwise.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-42 2-42 2-42 2-42 2-42 To remove the chassis wheels: 1. Lay the system chassis on its side. 2. Use a Phillips screwdriver to remove the screws that secure the wheels to the bottom of the chassis. 3. Repeat step 2 to remove the other three roller wheels. Remove the chassis roller wheels if you wish to mount the system to a rack. For convenient transport, install the roller wheels the came with the system package. Each wheel has a brake lock to stabilize the chassis in place. To install the chassis wheels: 1. Lay the chassis in its side. 2. Locate the designated screw holes for each of the four wheel sets. Take note of the numbers alongside each hole when placing screws. 3. Secure each wheel to the bottom of the chassis using four screws. 4. Repeat steps 2 and 3 to install the other three wheels. 3 3 3 3 3 1 1 1 1 1 2 2 2 2 2 4 4 4 4 4
2-43 2-43 2-43 2-43 2-43 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 2.10.7 2.10.7 2.10.7 2.10.7 2.10.7 Power supply unit Power supply unit Power supply unit Power supply unit Power supply unit Refer to this section when removing or installing a power supply unit to the barebone system. You MUST disconnect all power cable plugs from the motherboard and other installed devices before removing the power supply unit. The picture below shows the motherboard and device connectors where the power plugs are connected. Refer to the Appendix at the end of this document for the power supply specifications. 2 2 2 2 2 1 1 1 1 1 4 4 4 4 4 3 3 3 3 3 2 2 2 2 2 1 1 1 1 1 3 3 3 3 3 Model PA4 Model PA4 Model PA4 Model PA4 Model PA4 1. 24-pin ATX (motherboard power connector) 2. 4-pin 12V (motherboard power connector, hidden behind the cables) 3. 4-pin plug (optical drive) 4. 2 x 4-pin plugs (SATA backplane) 5. 4-pinplug (floppy disk drive, hidden behind the backplane) Model PS4 Model PS4 Model PS4 Model PS4 Model PS4 1. 24-pin ATX (motherboard power connector) 2. 4-pin 12V (motherboard power connector, hidden behind the cables) 3. 4-pin plug (optical drive) 4. 2 x 4-pin plugs (SCSI backplane) 5. 4-pinplug (floppy disk drive, hidden behind the backplane) 4 4 4 4 4 5 5 5 5 5 5 5 5 5 5 Make sure to unplug ALL ALL ALL ALL ALL power cables from the system devices before removing the power supply unit.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-44 2-44 2-44 2-44 2-44 To remove the power supply unit (PSU): 1. Remove the chassis cover. Refer to section “2.1.1 Removing the side cover.” 2. Remove the front panel assembly. Refer to section “2.5.1 Removing the front panel assembly. 3. Lay the chassis on a flat, stable surface. 4. Locate the four screws on the rear panel. Remove the screws and set them aside. 5. Locate and remove the screws that secure the PSU bracket to the chassis. 6. Slide the bracket in the direction of the arrow and remove it from the chassis.
2-45 2-45 2-45 2-45 2-45 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 7. Carefully slide the PSU in the direction of the arrow until it disengages from the chassis. To reinstall the power supply unit: 1. Carefully slide the PSU in the direction of the arrow. 2. Secure the PSU to the chassis with the four screws you removed earlier.
Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup Chapter 2: Hardware setup 2-46 2-46 2-46 2-46 2-46 3. Slide in the PSU bracket. 4. Align the screw holes. 5. Secure the bracket with screws you removed earlier.
3-1 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 This chapter describes how to install optional components into the barebone server. Chapter 3 Installation option
Chapter 3: Installation option Chapter 3: Installation option Chapter 3: Installation option Chapter 3: Installation option Chapter 3: Installation option 3-2 3-2 3-2 3-2 3-2 The items required for the optional configurations described in this chapter are not included in the standard barebone system package. These items are purchased separately. Preparing the system for rack mounting Removing the footpads or roller wheels Removing the footpads or roller wheels Removing the footpads or roller wheels Removing the footpads or roller wheels Removing the footpads or roller wheels Refer to section “2.10.6 Chassis footpads and roller wheels” for instructions on removing the footpads or roller wheels. Removing the top cover Removing the top cover Removing the top cover Removing the top cover Removing the top cover To remove the top cover: 1. Remove the chassis cover. Refer to section “2.1.1 Removing the side cover.” 2. Remove the front panel assembly. Refer to section “2.5.1 Removing the front panel assembly. 3. Carefully slide out protruding portion of the top cover as shown. Attaching the rack rails Attaching the rack rails Attaching the rack rails Attaching the rack rails Attaching the rack rails Refer to the installation guide that came with the Rackmount Rail Kit for instructions on how to attach the rails and on the barebone server system and the corresponding rails on the industrial rack. 4. Locate two round mylars on top cover. 5. Carefully remove each mylar using a sharp, flat object such as the edge of a cutter.
3-1 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 This chapter gives information about the motherboard that comes with the server. This chapter includes the motherboard layout, jumper settings, and connector locations. Chapter 4 Motherboard info
Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information 4-2 4-2 4-2 4-2 4-2 4.1 Motherboard layouts P5MT model P5MT model P5MT model P5MT model P5MT model P5MT 8Mbit Flash BIOS Super I/O PRI_IDE1 25cm (9.8in) 30.5cm (12in) DDR2 DIMM_A1 (64 bit,240-pin module) DDR2 DIMM_B1 (64 bit,240-pin module) DDR2 DIMM_A2 (64 bit,240-pin module) DDR2 DIMM_B2 (64 bit,240-pin module) S ATA 1 AT I RAGE XL VGA Controller AUX_P ANEL1 KBPWR1 PS/2KBMS T : Mouse B: Keyboard LAN1 LAN2 ® USB12 COM1 P ARALLEL POR T VGA1 PCIE1 PCIX3 PCIX2 FRNT_FAN1 FRNT_FAN2 S ATA 2 S ATA 3 S ATA 4 P ANEL1 RECOVERY1 USB34 USBPW34 HDLED1 BUZZ1 FLOPPY1 BMCCONN1 TRPWR1 BPSMB1 VGA_EN1 SB_PWR1 COM2 LAN_EN2 LAN_EN1 Broadcom BCM5721 Broadcom BCM5721 Intel E7230 Intel 6702 PXH Intel ICH7R BMCSOCKET1 LAN2 LGA775 PCI4 PSUSMB1 CR2032 3V Lithium Cell CMOS Power USBPW12 REAR_FAN1 A TX12V1 FM_CPU2 CPU_FAN2 FM_CPU1 CPU_FAN1 CLRTC1 A TXPWR1 REAR_FAN2 RAID_SEL1
4-3 4-3 4-3 4-3 4-3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 P5MT/SCSI model P5MT/SCSI model P5MT/SCSI model P5MT/SCSI model P5MT/SCSI model P5MT/SCSI 8Mbit Flash BIOS Super I/O PRI_IDE1 25cm (9.8in) 30.5cm (12in) DDR2 DIMM_A1 (64 bit,240-pin module) DDR2 DIMM_B1 (64 bit,240-pin module) DDR2 DIMM_A2 (64 bit,240-pin module) DDR2 DIMM_B2 (64 bit,240-pin module) S ATA 1 AT I RAGE XL VGA Controller AUX_P ANEL1 KBPWR1 PSUSMB1 CR2032 3V Lithium Cell CMOS Power PS/2KBMS T : Mouse B: Keyboard LAN1 LAN2 ® USB12 COM1 P ARALLEL POR T VGA1 USBPW12 REAR_FAN1 A TX12V1 FM_CPU2 CPU_FAN2 FM_CPU1 CPU_FAN1 PCIE1 PCIX3 PCIX2 FRNT_FAN1 FRNT_FAN2 SCSIA1 S ATA 2 S ATA 3 S ATA 4 P ANEL1 RECOVERY1 USB34 USBPW34 HDLED1 BUZZ1 FLOPPY1 BMCCONN1 TRPWR1 CLRTC1 BPSMB1 VGA_EN1 SB_PWR1 COM2 LAN_EN2 LAN_EN1 Broadcom BCM5721 Broadcom BCM5721 LSI 1020A Intel E7230 Intel 6702 PXH Intel ICH7R BMCSOCKET1 LAN2 LGA775 PCI4 SCSI_EN1 A TXPWR1 REAR_FAN2 RAID_SEL1
Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information 4-4 4-4 4-4 4-4 4-4 Layout contents Layout contents Layout contents Layout contents Layout contents Jumpers Jumpers Jumpers Jumpers Jumpers Page Page Page Page Page 1. Clear RTC RAM (CLRTC1) 4-5 2. CPU fan pin selection (3-pin FM_CPU1, FM_CPU2) 4-6 3. USB device wake-up (3-pin USBPW1, USBPW2) 4-6 4. Keyboard power (3-pin KBPWR1) 4-7 5. VGA controller setting (3-pin VGA_EN1) 4-7 6. Gigabit LAN controller setting (3-pin LAN_EN1; LAN_EN2) 4-8 7. RAID controller selection (3-pin RAID_SEL1) 4-8 8. SCSI controller setting (3-pin SCSI_EN1) 4-9 (P5MT/SCSI model only) 9. Force BIOS recovery setting (3-pin RECOVERY1) 4-9 Internal connectors Internal connectors Internal connectors Internal connectors Internal connectors Page Page Page Page Page 1. Floppy disk drive connector (34-1 pin FLOPPY1) 4-10 2. Primary IDE connectors (40-1 pin PRI_IDE1) 4-10 3. Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4) 4-11 4. Hard disk activity LED connector (4-pin HDLED1) 4-12 5. USB connector (10-1 pin USB34) 4-12 6. Ultra320 SCSI connectors (one 68-pin SCSIA1) 4-13 (present in P5MT/SCSI model only) 7. Serial port connector (10-1 pin COM2) 4-14 8. BMC connector (16-pin BMCCONN1) 4-14 9. Ambient thermal sensor (2-pin TRPWR1) 4-14 10. CPU and system fan connectors (3-pin CPU_FAN1/2, 4-15 REAR_FAN1/2, FRNT_FAN1/2) 11. Backplane SMBus connector (6-1 pin BPSMB1) 4-15 12. Power supply SMBus connector (5-pin PSUSMB1) 4-16 13. ATX power connectors (24-pin ATXPWR1, 4-pin ATX12V1) 4-16 14. System panel connector (20-pin PANEL1) 4-17 15. Auxiliary panel connector (20-pin AUX_PANEL1) 4-18
4-5 4-5 4-5 4-5 4-5 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 Except when clearing the RTC RAM, never remove the cap on CLRTC jumper default position. Removing the cap will cause system boot failure! 4.2 Jumpers The grayed out components in the illustrations may not be present in certain models. 1. 1. 1. 1. 1. Clear RTC RAM (CLRTC1) Clear RTC RAM (CLRTC1) Clear RTC RAM (CLRTC1) Clear RTC RAM (CLRTC1) Clear RTC RAM (CLRTC1) This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords. To erase the RTC RAM: 1. Turn OFF the computer and unplug the power cord. 2. Remove the onboard battery. 3. Move the jumper cap from pins 1-2 (default) to pins 2-3. Keep the cap on pins 2-3 for about 5~10 seconds, then move the cap back to pins 1-2. 4. Re-install the battery. 5. Plug the power cord and turn ON the computer. 6. Hold down the <Del> key during the boot process and enter BIOS setup to re-enter data. LAN2 ® P5MT Series Clear RTC RAM CLRTC1 Normal (Default) Clear CMO S 12 23
Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information 4-6 4-6 4-6 4-6 4-6 3. 3. 3. 3. 3. USB device wake-up (3-pin USBPW12, USBPW34) USB device wake-up (3-pin USBPW12, USBPW34) USB device wake-up (3-pin USBPW12, USBPW34) USB device wake-up (3-pin USBPW12, USBPW34) USB device wake-up (3-pin USBPW12, USBPW34) Set these jumpers to 5V to wake up the computer from S1 sleep mode (CPU stopped, DRAM refreshed, system running in low power mode) using the connected USB devices. Set to 5VSB to wake up from S4 sleep mode (no power to CPU, DRAM in slow refresh, power supply in reduced power mode). • The USB device wake-up feature requires a power supply that can provide 500mA on the 5VSB lead for each USB port; otherwise, the system would not power up. • If you are using Windows 2000, you need to install Service Pack 4 to wake up the system from S4 sleep mode. • The total current consumed must NOT exceed the power supply capability ( 5VSB) whether under normal condition or in sleep mode. 2. 2. 2. 2. 2. CPU fan pin selection (3-pin FM_CPU1, FM_CPU2) CPU fan pin selection (3-pin FM_CPU1, FM_CPU2) CPU fan pin selection (3-pin FM_CPU1, FM_CPU2) CPU fan pin selection (3-pin FM_CPU1, FM_CPU2) CPU fan pin selection (3-pin FM_CPU1, FM_CPU2) These jumpers allow you to connect either a 3-pin or a 4-pin fan cable plug to the CPU fan connectors (CPU_FAN1, CPU_FAN2). Set these jumpers to pins 1-2 if you are using a 3-pin fan cable plug, or to pins 2-3 if you are using a 4-pin plug. LAN2 ® P5MT Series FM CPU Setting FM_CPU2 FM_CPU1 12 23 3-pin fan 4-pin fan (Default) 2 3 2 1 3-pin fan 4-pin fan (Default) LAN2 ® P5MT Series USB device wake-up USBPW12 (Default) 5V 5VS B 23 12 USBPW34 (Default) 5V 5VS B 23 12
4-7 4-7 4-7 4-7 4-7 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 4. 4. 4. 4. 4. Keyboard power (3-pin KBPWR1) Keyboard power (3-pin KBPWR1) Keyboard power (3-pin KBPWR1) Keyboard power (3-pin KBPWR1) Keyboard power (3-pin KBPWR1) This jumper allows you to enable or disable the keyboard wake-up feature. Set this jumper to pins 2-3 ( 5VSB) to wake up the computer when you press a key on the keyboard (the default is the Space Bar). This feature requires an ATX power supply that can supply at least 1A on the 5VSB lead, and a corresponding setting in the BIOS. 5. 5. 5. 5. 5. VGA controller setting (3-pin VGA_EN1) VGA controller setting (3-pin VGA_EN1) VGA controller setting (3-pin VGA_EN1) VGA controller setting (3-pin VGA_EN1) VGA controller setting (3-pin VGA_EN1) These jumpers allow you to enable or disable the onboard ATI ® RAGE-XL PCI VGA controller. Set to pins 1-2 to activate the VGA feature. LAN2 ® P5MT Series Keyboard power setting KBPWR1 (Default) 5V 5VSB 23 12 LAN2 ® P5MT Series VGA setting VGA_EN1 Enable (Default) Disabl e 2 1 2 3
Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information 4-8 4-8 4-8 4-8 4-8 6. 6. 6. 6. 6. Gigabit LAN controller setting (3-pin LAN_EN1, Gigabit LAN controller setting (3-pin LAN_EN1, Gigabit LAN controller setting (3-pin LAN_EN1, Gigabit LAN controller setting (3-pin LAN_EN1, Gigabit LAN controller setting (3-pin LAN_EN1, LAN_EN2) LAN_EN2) LAN_EN2) LAN_EN2) LAN_EN2) These jumpers allow you to enable or disable the onboard Broadcom ® BCM5721 Gigabit LAN1 or LAN2 controller. Set to pins 1-2 to activate the Gigabit LAN controller. LAN2 ® P5MT Series LAN_EN1 setting Enable (Default) Disabl e LAN_EN1 2 1 2 3 LAN2 ® P5MT Series LAN_EN2 setting Enable (Default) Disabl e LAN_EN2 2 1 2 3 7. 7. 7. 7. 7. RAID controller selection (3-pin RAID_SEL1) RAID controller selection (3-pin RAID_SEL1) RAID controller selection (3-pin RAID_SEL1) RAID controller selection (3-pin RAID_SEL1) RAID controller selection (3-pin RAID_SEL1) This jumper allows you to select the RAID configuration utility to use when you create disk arrays. Place the jumper caps over pins 1-2 if you want to use the LSI Logic Embedded SATA RAID Setup Utility (default); otherwise, place the jumper caps to pins 2-3 to use the Intel ® Matrix Storage Manager. LAN2 ® RAID_SEL1 LSI RAID ROM (Default) INTEL RAID ROM 2 1 2 3 P5MT Series RAID_SEL1 setting
4-9 4-9 4-9 4-9 4-9 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 9. 9. 9. 9. 9. Force BIOS recovery setting (3-pin RECOVERY1) Force BIOS recovery setting (3-pin RECOVERY1) Force BIOS recovery setting (3-pin RECOVERY1) Force BIOS recovery setting (3-pin RECOVERY1) Force BIOS recovery setting (3-pin RECOVERY1) This jumper allows you to quickly update or recover the BIOS settings when it becomes corrupted. To update the BIOS: 1. Prepare a floppy disk that contains the latest BIOS for the motherboard (xxxx-xxx.ROM) and the AFUDOS.EXE utility. 2. Set the jumper to pins 2-3. 3. Insert the floppy disk then turn on the system to update the BIOS. 4. Shut down the system. 5. Set the jumper back to pins 1-2. 6. Turn on the system. 8. 8. 8. 8. 8. SCSI controller setting (3-pin SCSI_EN1) SCSI controller setting (3-pin SCSI_EN1) SCSI controller setting (3-pin SCSI_EN1) SCSI controller setting (3-pin SCSI_EN1) SCSI controller setting (3-pin SCSI_EN1) (P5MT/SCSI model only) (P5MT/SCSI model only) (P5MT/SCSI model only) (P5MT/SCSI model only) (P5MT/SCSI model only) This jumper allows you to enable or disable the onboard LSI 53C1020A PCI-X SCSI controller. Set to pins 1-2 to activate the SCSI feature, and support RAID configurations. LAN2 ® 23 12 P5MT Series SCSI_EN1 setting SCSI_EN1 Enable (Default) Disabl e LAN2 ® P5MT Series BIOS recovery setting RECOVERY1 (Default) Normal BIOS recover y 2 3 2 1
Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information 4-10 4-10 4-10 4-10 4-10 2. 2. 2. 2. 2. Primary IDE connector (40-1 pin PRI_IDE1) Primary IDE connector (40-1 pin PRI_IDE1) Primary IDE connector (40-1 pin PRI_IDE1) Primary IDE connector (40-1 pin PRI_IDE1) Primary IDE connector (40-1 pin PRI_IDE1) This connector is for an Ultra ATA100/66/33 signal cable. The Ultra ATA 100/66/33 signal cable has three connectors: a blue connector for the primary IDE connector on the motherboard, a black connector for an Ultra ATA 100/66/33 IDE slave device (optical drive/hard disk drive), and a gray connector for an Ultra ATA 100/66/33 IDE master device (hard disk drive). If you install two hard disk drives, you must configure the second drive as a slave device by setting its jumper accordingly. Refer to the hard disk documentation for the jumper settings. 4.3 Internal connectors 1. 1. 1. 1. 1. Floppy disk drive connector (34-1 pin FLOPPY1) Floppy disk drive connector (34-1 pin FLOPPY1) Floppy disk drive connector (34-1 pin FLOPPY1) Floppy disk drive connector (34-1 pin FLOPPY1) Floppy disk drive connector (34-1 pin FLOPPY1) This connector is for the provided floppy disk drive (FDD) signal cable. Insert one end of the cable to this connector, then connect the other end to the signal connector at the back of the floppy disk drive. Pin 5 on the connector is removed to prevent incorrect cable connection when using a FDD cable with a covered Pin 5. • Pin 20 on the IDE connector is removed to match the covered hole on the Ultra ATA cable connector. This prevents incorrect insertion when you connect the IDE cable. • Use the 80-conductor IDE cable for Ultra ATA 100/66/33 IDE devices. LAN2 ® NOTE: Orient the red markings o n the floppy ribbon cable to PIN 1. P5MT Series Floppy disk drive connector FLOPPY1 PIN 1 LAN2 ® P5MT Series IDE connector NOTE: Orient the red markings (usually zigzag) on the IDE ribbon cable to PIN 1. PRI_IDE1 PIN 1
4-11 4-11 4-11 4-11 4-11 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 3. 3. 3. 3. 3. Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4) Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4) Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4) Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4) Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4) These connectors are for the Serial ATA signal cables for Serial ATA hard disk drives. If you installed Serial ATA hard disk drives, you can create a RAID 0, RAID 1, RAID 0 1, and software RAID 5 configuration using the Intel ® Matrix Storage Technology or RAID 0, RAID 1 and RAID 0 1 configuration using the LSI MegaRAID ® utility embedded on the Intel ® ICH7R Southbridge. Serial ATA hard disk drive connection Serial ATA hard disk drive connection Serial ATA hard disk drive connection Serial ATA hard disk drive connection Serial ATA hard disk drive connection Connector Connector Connector Connector Connector Setting Setting Setting Setting Setting Use Use Use Use Use SATA1/SATA2 SATA1/SATA2 SATA1/SATA2 SATA1/SATA2 SATA1/SATA2 Master Master Master Master Master Boot disk Boot disk Boot disk Boot disk Boot disk SATA3/SATA4 SATA3/SATA4 SATA3/SATA4 SATA3/SATA4 SATA3/SATA4 Slave Slave Slave Slave Slave Data disk Data disk Data disk Data disk Data disk These connectors are set IDE IDE IDE IDE IDE mode by default. In IDE IDE IDE IDE IDE mode, you can connect Serial ATA boot/data hard disk drives to these connectors. If you intend to create a Serial ATA RAID set using these connectors, set the Configure SATA as Configure SATA as Configure SATA as Configure SATA as Configure SATA as item in the BIOS to [RAID]. See section “4.3.4 IDE Configuration” for details. Important notes on Serial ATA Important notes on Serial ATA Important notes on Serial ATA Important notes on Serial ATA Important notes on Serial ATA • You must install Windows ® 2000 Service Pack 4 or Windows ® 2003 before using Serial ATA hard disk drives. The Serial ATA RAID feature (RAID 0/RAID 1) is available only if you are using Windows ® 2000/2003. • Use only two Serial ATA RAID connectors for each RAID 0 or RAID 1 set. • When using the connectors in IDE IDE IDE IDE IDE mode, connect the primary (boot) hard disk drive to the SATA1 or SATA2 connector. Refer to the table below for the recommended SATA hard disk drive connections. LAN2 ® P5MT Series SA T A connectors S ATA 2 GND RSA T A_TXP2 RSA T A_TXN2 GND RSA T A_RXP2 RSA T A_RXN2 GND S ATA 1 GND RSA T A_TXP1 RSA T A_TXN1 GND RSA T A_RXP1 RSA T A_RXN1 GND S ATA 4 GND RSA T A_TXP4 RSA T A_TXN4 GND RSA T A_RXP4 RSA T A_RXN4 GND S ATA 3 GND RSA T A_TXP3 RSA T A_TXN3 GND RSA T A_RXP3 RSA T A_RXN3 GND
Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information 4-12 4-12 4-12 4-12 4-12 4. 4. 4. 4. 4. Hard disk activity LED connector (4-pin HDLED1) Hard disk activity LED connector (4-pin HDLED1) Hard disk activity LED connector (4-pin HDLED1) Hard disk activity LED connector (4-pin HDLED1) Hard disk activity LED connector (4-pin HDLED1) This connector supplies power to the hard disk activity LED. The read or write activities of any device connected to the SCSI connectors or the SATA connectors cause this LED to light up. 5. 5. 5. 5. 5. USB connector (10-1 pin USB34) USB connector (10-1 pin USB34) USB connector (10-1 pin USB34) USB connector (10-1 pin USB34) USB connector (10-1 pin USB34) This connector is for USB 2.0 ports. Connect the USB module cable to this connector, then install the module to a slot opening at the back of the system chassis. This USB connector complies with USB 2.0 specification that supports up to 480 Mbps connection speed. LAN2 ® P5MT Series SCSI/SA T A card activity LED connecto r HDLED1 1 ADD_IN_CARD_ACT# NC ADD_IN_CARD_ACT# NC LAN2 ® USB 5V USB_P3- USB_P3 GND NC P5MT Series USB 2.0 connector USB34 USB 5V USB_P2- USB_P2 GND The USB port module is purchased separately.
4-13 4-13 4-13 4-13 4-13 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6. 6. 6. 6. 6. Ultra320 SCSI connectors (one 68-pin SCSIA1) Ultra320 SCSI connectors (one 68-pin SCSIA1) Ultra320 SCSI connectors (one 68-pin SCSIA1) Ultra320 SCSI connectors (one 68-pin SCSIA1) Ultra320 SCSI connectors (one 68-pin SCSIA1) (P5MT/SCSI model only) (P5MT/SCSI model only) (P5MT/SCSI model only) (P5MT/SCSI model only) (P5MT/SCSI model only) This motherboard comes with the LSI53C1020A PCI-X SCSI U320 controller that supports one 68-Pin Ultra320 SCSI connector. The SCSI channel can support a maximum of 15 SCSI devices as specified by Ultra320 standards. SCSI Connection Notes SCSI Connection Notes SCSI Connection Notes SCSI Connection Notes SCSI Connection Notes This motherboard has a 68-Pin Ultra320 SCSI connector. The onboard SCSI chipset incorporates an advanced multimode I/O cell that supports both single-ended (SE), Ultra2, Ultra160, and Ultra320 devices. With Ultra320 devices, the SCSI bus platform performs at full Ultra320 speeds (up to 320MB/s) and extended cabling 12m (or 25m in a point-to-point configuration). When an SE device is attached, the bus defaults to an SE speed and 1.5m cable length. Connect SCSI devices as specified. A SCSI channel should have only one type of SCSI standard (e.g. Ultra320, Ultra160, Ultra2, Ultra-Wide). Mixing SCSI devices on a single channel decreases performance of the slower device. LAN2 ® P5MT Series Onboard SCSI connectors 35 68 34 1 SCSIA1 68-Pin Ultra320/ Ultra2-Wide SCSI Connector
Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information 4-14 4-14 4-14 4-14 4-14 7. 7. 7. 7. 7. Serial port connector (10-1 pin COM2) Serial port connector (10-1 pin COM2) Serial port connector (10-1 pin COM2) Serial port connector (10-1 pin COM2) Serial port connector (10-1 pin COM2) This connector is for a serial (COM) port. Connect the serial port module cable to this connector, then install the module to a slot opening at the back of the system chassis. The serial port module is purchased separately. 8. 8. 8. 8. 8. BMC connector (16-pin BMCCONN1) BMC connector (16-pin BMCCONN1) BMC connector (16-pin BMCCONN1) BMC connector (16-pin BMCCONN1) BMC connector (16-pin BMCCONN1) This connector is for the ASUS server management card, if available. LAN2 ® P5MT Series Serial port2 (COM2) connector PIN 1 COM2 LAN2 ® P5MT Series BMC connector BMCCONN1 5VSB 5VSB BMC SMBCLK 12CCLK1 PSON# BMC_RST# PWROK PSONEN# 5VSB 5VSB BMC SMBDA T A 12CDA T A1 FP_PWRBTN# BMC_PRESENT# BMC_SMI# GND 9. 9. 9. 9. 9. Ambient thermal sensor (2-pin TRPWR1) Ambient thermal sensor (2-pin TRPWR1) Ambient thermal sensor (2-pin TRPWR1) Ambient thermal sensor (2-pin TRPWR1) Ambient thermal sensor (2-pin TRPWR1) If you want additional thermal monitoring, connect the thermal sensor cable with thermistor (of 1ºK or at 25ºC, B=3435) to this connector. LAN2 ® P5MT Series TRPWR connector TRPWR1 SYS-THEAMAL 2 GND
4-15 4-15 4-15 4-15 4-15 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 10. 10. 10. 10. 10. CPU and system fan connectors (3-pin CPU_FAN1/2, CPU and system fan connectors (3-pin CPU_FAN1/2, CPU and system fan connectors (3-pin CPU_FAN1/2, CPU and system fan connectors (3-pin CPU_FAN1/2, CPU and system fan connectors (3-pin CPU_FAN1/2, REAR_FAN1/2, FRNT_FAN1/2) REAR_FAN1/2, FRNT_FAN1/2) REAR_FAN1/2, FRNT_FAN1/2) REAR_FAN1/2, FRNT_FAN1/2) REAR_FAN1/2, FRNT_FAN1/2) The fan connectors support cooling fans of 350 mA ~ 740 mA (8.88 W max.) or a total of 2.1 A ~ 4.44 A (5 3.28 W max.) at 12V. Connect the fan cables to the fan connectors on the motherboard, making sure that the black wire of each cable matches the ground pin of the connector. Do not forget to connect the fan cables to the fan connectors. Insufficient air flow inside the system may damage the motherboard components. These are not jumpers! Do not place jumper caps on the fan connectors! 11. 11. 11. 11. 11. Backplane SMBus connector (6-1 pin BPSMB1) Backplane SMBus connector (6-1 pin BPSMB1) Backplane SMBus connector (6-1 pin BPSMB1) Backplane SMBus connector (6-1 pin BPSMB1) Backplane SMBus connector (6-1 pin BPSMB1) This connector allows you to connect SMBus (System Management Bus) devices. Devices communicate with an SMBus host and/or other SMBus devices using the SMBus interface. LAN2 ® P5MT Series Fan connectors REAR_F AN 2 REAR_F AN1 FRNT_F AN1 FRNT_F AN 2 GND F ANPWR2 F ANOUT4 CPU_F AN2 CPU_F AN1 GND F ANPWR2 F ANOUT4 GND Rotation 12V CPU_F AN2 REAR_F AN2 REAR_F AN1 FRNT_F AN1 FRNT_F AN2 CPU_F AN1 GND Rotation 12V GND Rotation 12V GND Rotation 12V LAN2 ® P5MT Series SMBus connector BPSMB1 1 I2C_CLK GND I2C_DA T A 5V F ANOUT
Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information 4-16 4-16 4-16 4-16 4-16 12. 12. 12. 12. 12. Power supply SMBus connector (5-pin PSUSMB1) Power supply SMBus connector (5-pin PSUSMB1) Power supply SMBus connector (5-pin PSUSMB1) Power supply SMBus connector (5-pin PSUSMB1) Power supply SMBus connector (5-pin PSUSMB1) This connector is for the power supply SMB cable, if your power supply supports the SMBus function. 13. 13. 13. 13. 13. SSI SSI SSI SSI SSI power connectors (24-pin ATXPWR1, power connectors (24-pin ATXPWR1, power connectors (24-pin ATXPWR1, power connectors (24-pin ATXPWR1, power connectors (24-pin ATXPWR1, 8 8 8 8 8 -pin -pin -pin -pin -pin ATX12V2 ATX12V2 ATX12V2 ATX12V2 ATX12V2 ) ) ) ) ) These connectors are for SSI power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit. • Use of an SSI 12 V Specification 2.0-compliant power supply unit (PSU) that provides a minimum power of 450 W is recommended for a fully-configured system. • By default, four ATX12V2 connector pins are covered to prevent incorrent insertion of a 4-pin ATX 12V power plug. Remove this cover when using a PSU with an 8-pin ATX 12V power plug. • Do not forget to connect the 4-pin or 8-pin ATX 12 V power plug; otherwise, the system will not boot up. • Use of a PSU with a higher power output is recommended when configuring a system with more power consuming devices. The system may become unstable or may not boot up if the power is inadequate. • You must install a PSU with a higher power rating if you intend to install additional devices. LAN2 ® P5MT Series Power supply SMBus connecto r PSUSMB1 3.3V Remote Sense GND NC PSU_I2CDA T A PSU_I2CCLK LAN2 ® P5MT Series A TX power connectors 24-pin Power Connector A TX12V2 A TXPWR1 3 V olts 3 V olts Ground 5 V olts 5 V olts Ground Ground Power OK 5V Standby 12 V olts -5 V olts 5 V olts 3 V olts -12 V olts Ground Ground Ground PSON# Ground 5 V olts 12 V olts 3 V olts 5 V olts 1 Ground GND 12V DC GND 12V DC GND 12V DC GND 12V DC
4-17 4-17 4-17 4-17 4-17 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 14. 14. 14. 14. 14. System panel connector (20-pin PANEL1) System panel connector (20-pin PANEL1) System panel connector (20-pin PANEL1) System panel connector (20-pin PANEL1) System panel connector (20-pin PANEL1) This connector supports several chassis-mounted functions. • System power LED (Green 3-pin PLED) System power LED (Green 3-pin PLED) System power LED (Green 3-pin PLED) System power LED (Green 3-pin PLED) System power LED (Green 3-pin PLED) This 3-pin connector is for the system power LED. Connect the chassis power LED cable to this connector. The system power LED lights up when you turn on the system power, and blinks when the system is in sleep mode. • Hard disk drive activity LED (Red 2-pin IDE_LED) Hard disk drive activity LED (Red 2-pin IDE_LED) Hard disk drive activity LED (Red 2-pin IDE_LED) Hard disk drive activity LED (Red 2-pin IDE_LED) Hard disk drive activity LED (Red 2-pin IDE_LED) This 2-pin connector is for the HDD Activity LED. Connect the HDD Activity LED cable to this connector. The IDE LED lights up or flashes when data is read from or written to the HDD. • System warning speaker (Orange 4-pin SPEAKER) System warning speaker (Orange 4-pin SPEAKER) System warning speaker (Orange 4-pin SPEAKER) System warning speaker (Orange 4-pin SPEAKER) System warning speaker (Orange 4-pin SPEAKER) This 4-pin connector is for the chassis-mounted system warning speaker. The speaker allows you to hear system beeps and warnings. • ATX power button/soft-off button ATX power button/soft-off button ATX power button/soft-off button ATX power button/soft-off button ATX power button/soft-off button (Light Green 2-pin PWRSW) (Light Green 2-pin PWRSW) (Light Green 2-pin PWRSW) (Light Green 2-pin PWRSW) (Light Green 2-pin PWRSW) This connector is for the system power button. Pressing the power button turns the system on or puts the system in sleep or soft-off mode depending on the BIOS settings. Pressing the power switch for more than four seconds while the system is ON turns the system OFF. • Reset button (Blue 2-pin RESET) Reset button (Blue 2-pin RESET) Reset button (Blue 2-pin RESET) Reset button (Blue 2-pin RESET) Reset button (Blue 2-pin RESET) This 2-pin connector is for the chassis-mounted reset button for system reboot without turning off the system power. The system panel connector is color-coded for easy connection. LAN2 ® P5MT Series System panel connector P ANEL1 MLED- GND NC POWERBTN# 5V GND GND NC POWERLED HDLED GND HDLED- POWERLED- MLED NMIBTN# GND RESETBTN# SPKROUT GND
Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information Chapter 4: Motherboard information 4-18 4-18 4-18 4-18 4-18 15. 15. 15. 15. 15. Auxiliary panel connector (20-pin AUX_PANEL1) Auxiliary panel connector (20-pin AUX_PANEL1) Auxiliary panel connector (20-pin AUX_PANEL1) Auxiliary panel connector (20-pin AUX_PANEL1) Auxiliary panel connector (20-pin AUX_PANEL1) This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs. • Front panel SMB (6-1 pin FPSMB) Front panel SMB (6-1 pin FPSMB) Front panel SMB (6-1 pin FPSMB) Front panel SMB (6-1 pin FPSMB) Front panel SMB (6-1 pin FPSMB) These leads connect the front panel SMBus cable. • LAN activity LED (2-pin LAN1_LED, LAN2_LED) LAN activity LED (2-pin LAN1_LED, LAN2_LED) LAN activity LED (2-pin LAN1_LED, LAN2_LED) LAN activity LED (2-pin LAN1_LED, LAN2_LED) LAN activity LED (2-pin LAN1_LED, LAN2_LED) These leads are for Gigabit LAN activity LEDs on the front panel. • Chassis intrusion (2-pin CHASSIS) Chassis intrusion (2-pin CHASSIS) Chassis intrusion (2-pin CHASSIS) Chassis intrusion (2-pin CHASSIS) Chassis intrusion (2-pin CHASSIS) These leads are for the intrusion detection feature for chassis with intrusion sensor or microswitch. When you remove any chassis component, the sensor triggers and sends a high-level signal to these leads to record a chassis intrusion event. • Locator LED (6-pin LOCATOR) Locator LED (6-pin LOCATOR) Locator LED (6-pin LOCATOR) Locator LED (6-pin LOCATOR) Locator LED (6-pin LOCATOR) These leads are for the locator switch and LED on the front panel. LAN2 ® P5MT Series Auxiliary panel connector AUX_P ANEL1 I2C_4_DA TA# LOCAT ORLED1 5VSB LOCA TORLED1- LAN1_LINKACTLED LOCA TORBTN# LAN1_LINKACTLED- GND 5VSB I2C_4_CLK# GND GND LAN2_LINKACTLED- LOCA TORLED2- LAN2_LINKACTLED LOCA TORLED2 CASEOPEN PIN1 NC Front panel SMB Front panel SMB Front panel SMB Front panel SMB Front panel SMB LAN activity LED LAN activity LED LAN activity LED LAN activity LED LAN activity LED Chassis Chassis Chassis Chassis Chassis intrusion intrusion intrusion intrusion intrusion Locator LED Locator LED Locator LED Locator LED Locator LED and switch and switch and switch and switch and switch
3-1 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 This chapter tells how to change system settings through the BIOS Setup menus and describes the BIOS parameters. Chapter 5 BIOS information
Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information 5-2 5-2 5-2 5-2 5-2 5.1 Managing and updating your BIOS The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup. 1. ASUS AFUDOS ASUS AFUDOS ASUS AFUDOS ASUS AFUDOS ASUS AFUDOS (Updates the BIOS in DOS mode using a bootable floppy disk.) 2. ASUS CrashFree BIOS 2 ASUS CrashFree BIOS 2 ASUS CrashFree BIOS 2 ASUS CrashFree BIOS 2 ASUS CrashFree BIOS 2 (Updates the BIOS using a bootable floppy disk or the motherboard support CD when the BIOS file fails or gets corrupted.) 3. ASUS Update ASUS Update ASUS Update ASUS Update ASUS Update (Updates the BIOS in Windows ® environment.) Refer to the corresponding sections for details on these utilities. 5.1.1 5.1.1 5.1.1 5.1.1 5.1.1 Creating a bootable floppy disk Creating a bootable floppy disk Creating a bootable floppy disk Creating a bootable floppy disk Creating a bootable floppy disk 1. Do either one of the following to create a bootable floppy disk. DOS environment a. Insert a 1.44MB floppy disk into the drive. b. At the DOS prompt, type format A:/S then press <Enter>. Windows ® XP environment a. Insert a 1.44 MB floppy disk to the floppy disk drive. b. Click Start Start Start Start Start from the Windows ® desktop, then select My My My My My Computer Computer Computer Computer Computer . c. Select the 3 1/2 Floppy Drive icon. d. Click File File File File File from the menu, then select Format Format Format Format Format . A Format 3 1/2 Format 3 1/2 Format 3 1/2 Format 3 1/2 Format 3 1/2 Floppy Disk Floppy Disk Floppy Disk Floppy Disk Floppy Disk window appears. e. Windows Windows Windows Windows Windows ® ® ® ® ® XP users: XP users: XP users: XP users: XP users: Select Create an MS-DOS startup Create an MS-DOS startup Create an MS-DOS startup Create an MS-DOS startup Create an MS-DOS startup disk disk disk disk disk from the format options field, then click Start Start Start Start Start . 2. Copy the original or the latest motherboard BIOS file to the bootable floppy disk. Save a copy of the original motherboard BIOS file to a bootable floppy disk in case you need to restore the BIOS in the future. Copy the original motherboard BIOS using the ASUS Update or AFUDOS utilities.
5-3 5-3 5-3 5-3 5-3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5.1.2 5.1.2 5.1.2 5.1.2 5.1.2 AFUDOS utility AFUDOS utility AFUDOS utility AFUDOS utility AFUDOS utility The AFUDOS utility allows you to update the BIOS file in DOS environment using a bootable floppy disk with the updated BIOS file. This utility also allows you to copy the current BIOS file that you can use as backup when the BIOS fails or gets corrupted during the updating process. Copying the current BIOS Copying the current BIOS Copying the current BIOS Copying the current BIOS Copying the current BIOS To copy the current BIOS file using the AFUDOS utility: The utility returns to the DOS prompt after copying the current BIOS file. 3. Press <Enter>. The utility copies the current BIOS file to the floppy disk. A:\>afudos /oOLDBIOS1.rom AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB)) Copyright (C) 2002 American Megatrends, Inc. All rights reserved. Reading flash ..... done Write to file...... ok A:\> Main filename Main filename Main filename Main filename Main filename Extension name Extension name Extension name Extension name Extension name 1. Copy the AFUDOS utility (afudos.exe) from the motherboard support CD to the bootable floppy disk you created earlier. 2. Boot the system in DOS mode, then at the prompt type: afudos /o[filename] where the [filename] is any user-assigned filename not more than eight alphanumeric characters for the main filename and three alphanumeric characters for the extension name. A:\>afudos /oOLDBIOS1.rom • Make sure that the floppy disk is not write-protected and has at least 1024 KB free space to save the file. • The succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be the same as shown.
Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information 5-4 5-4 5-4 5-4 5-4 2. Copy the AFUDOS utility (afudos.exe) from the motherboard support CD to the bootable floppy disk you created earlier. 3. Boot the system in DOS mode, then at the prompt type: afudos /i[filename] where [filename] is the latest or the original BIOS file on the bootable floppy disk. Updating the BIOS file Updating the BIOS file Updating the BIOS file Updating the BIOS file Updating the BIOS file To update the BIOS file using the AFUDOS utility: 1. Visit the ASUS website (www.asus.com) and download the latest BIOS file for the motherboard. Save the BIOS file to a bootable floppy disk. A:\>afudos /iP5MT.rom Write the BIOS filename on a piece of paper. You need to type the exact BIOS filename at the DOS prompt. Use the appropriate BIOS file depending on your motherboard model (e.g. P5MT.ROM or P5MTSCSI.ROM) A:\>afudos /iP5MT.ROM AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB)) Copyright (C) 2002 American Megatrends, Inc. All rights reserved. WARNING!! Do not turn off power during flash BIOS Reading file ....... done Reading flash ...... done Advance Check ...... Erasing flash ...... done Writing flash ...... 0x0008CC00 (9%) 4. The utility verifies the file and starts updating the BIOS. Do not shut down or reset the system while updating the BIOS to prevent system boot failure!
5-5 5-5 5-5 5-5 5-5 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5. The utility returns to the DOS prompt after the BIOS update process is completed. Reboot the system from the hard disk drive. A:\>afudos /iP5MT.ROM AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB)) Copyright (C) 2002 American Megatrends, Inc. All rights reserved. WARNING!! Do not turn off power during flash BIOS Reading file ....... done Reading flash ...... done Advance Check ...... Erasing flash ...... done Writing flash ...... done Verifying flash .... done Please restart your computer A:\>
Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information 5-6 5-6 5-6 5-6 5-6 5.1.3 5.1.3 5.1.3 5.1.3 5.1.3 ASUS CrashFree BIOS 2 utility ASUS CrashFree BIOS 2 utility ASUS CrashFree BIOS 2 utility ASUS CrashFree BIOS 2 utility ASUS CrashFree BIOS 2 utility The ASUS CrashFree BIOS 2 is an auto recovery tool that allows you to restore the BIOS file when it fails or gets corrupted during the updating process. You can update a corrupted BIOS file using the motherboard support CD or the floppy disk that contains the updated BIOS file. Recovering the BIOS from a floppy disk Recovering the BIOS from a floppy disk Recovering the BIOS from a floppy disk Recovering the BIOS from a floppy disk Recovering the BIOS from a floppy disk To recover the BIOS from a floppy disk: 1. Turn on the system. 2. Insert the floppy disk with the original or updated BIOS file to the floppy disk drive. 3. The utility displays the following message and automatically checks the floppy disk for the original or updated BIOS file. Bad BIOS checksum. Starting BIOS recovery... Checking for floppy... 4. Restart the system after the utility completes the updating process. Bad BIOS checksum. Starting BIOS recovery... Checking for floppy... Floppy found! Reading file “P5MT.ROM”. Completed. Start flashing... When found, the utility reads the BIOS file and starts flashing the corrupted BIOS file. DO NOT shut down or reset the system while updating the BIOS! Doing so can cause system boot failure! • Prepare the motherboard support CD or the floppy disk containing the updated motherboard BIOS before using this utility. • Make sure that you rename the original or updated BIOS file in the floppy disk according the exact name of your motherboard, e.g. P5MT.ROM P5MT.ROM P5MT.ROM P5MT.ROM P5MT.ROM o r P5MTSCSI.ROM P5MTSCSI.ROM P5MTSCSI.ROM P5MTSCSI.ROM P5MTSCSI.ROM .
5-7 5-7 5-7 5-7 5-7 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 Recovering the BIOS from the support CD Recovering the BIOS from the support CD Recovering the BIOS from the support CD Recovering the BIOS from the support CD Recovering the BIOS from the support CD To recover the BIOS from the support CD: 1. Remove any floppy disk from the floppy disk drive, then turn on the system. 2. Insert the support CD to the optical drive. 3. The utility displays the following message and automatically checks the floppy disk for the original or updated BIOS file. 4. Restart the system after the utility completes the updating process. Bad BIOS checksum. Starting BIOS recovery... Checking for floppy... Floppy not found! Checking for CD-ROM... CD-ROM found! Reading file “P5MT.ROM”. Completed. Start flashing... When no floppy disk is found, the utility automatically checks the optical drive for the original or updated BIOS file. The utility then updates the corrupted BIOS file. Bad BIOS checksum. Starting BIOS recovery... Checking for floppy... DO NOT shut down or reset the system while updating the BIOS! Doing so can cause system boot failure! The recovered BIOS may not be the latest BIOS version for this motherboard. Visit the ASUS website (www.asus.com) to download the latest BIOS file.
Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information 5-8 5-8 5-8 5-8 5-8 Installing ASUS Update Installing ASUS Update Installing ASUS Update Installing ASUS Update Installing ASUS Update To install ASUS Update: 1. Place the support CD in the optical drive. The Drivers Drivers Drivers Drivers Drivers menu appears. 2. Click the Utilities Utilities Utilities Utilities Utilities tab, then click Install ASUS Update Install ASUS Update Install ASUS Update Install ASUS Update Install ASUS Update VX.XX.XX VX.XX.XX VX.XX.XX VX.XX.XX VX.XX.XX . 3. The ASUS Update utility is copied to your system. 5.1.4 5.1.4 5.1.4 5.1.4 5.1.4 ASUS Update utility ASUS Update utility ASUS Update utility ASUS Update utility ASUS Update utility The ASUS Update is a utility that allows you to manage, save, and update the motherboard BIOS in Windows ® environment. The ASUS Update utility allows you to: • Save the current BIOS file • Download the latest BIOS file from the Internet • Update the BIOS from an updated BIOS file • Update the BIOS directly from the Internet, and • View the BIOS version information. This utility is available in the support CD that comes with the motherboard package. ASUS Update requires an Internet connection either through a network or an Internet Service Provider (ISP). Quit all Microsoft ® Windows ® applications before you update the BIOS using this utility.
5-9 5-9 5-9 5-9 5-9 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 3. Select the ASUS FTP site nearest you to avoid network traffic, or click Auto Select Auto Select Auto Select Auto Select Auto Select . Click Next Next Next Next Next . Updating the BIOS through the Internet Updating the BIOS through the Internet Updating the BIOS through the Internet Updating the BIOS through the Internet Updating the BIOS through the Internet To update the BIOS through the Internet: 1. Launch the ASUS Update utility from the Windows ® desktop by clicking Start Start Start Start Start > Programs Programs Programs Programs Programs > ASUS ASUS ASUS ASUS ASUS > ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate > ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate . T h e ASUS Update main window appears. 2. Select Update BIOS from Update BIOS from Update BIOS from Update BIOS from Update BIOS from the Internet the Internet the Internet the Internet the Internet option from the drop-down menu, then click Next Next Next Next Next .
Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information Chapter 5: Motherboard information 5-10 5-10 5-10 5-10 5-10 Updating the BIOS through a BIOS file Updating the BIOS through a BIOS file Updating the BIOS through a BIOS file Updating the BIOS through a BIOS file Updating the BIOS through a BIOS file To update the BIOS through a BIOS file: 1. Launch the ASUS Update utility from the Windows ® desktop by clicking Start Start Start Start Start > Programs Programs Programs Programs Programs > ASUS ASUS ASUS ASUS ASUS > ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate > ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate ASUSUpdate . The ASUS Update main window appears. 2. Select Update BIOS from a Update BIOS from a Update BIOS from a Update BIOS from a Update BIOS from a file file file file file option from the drop-down menu, then click Next Next Next Next Next . 4. From the FTP site, select the BIOS version that you wish to download. Click Next. 5. Follow the screen instructions to complete the update process. The ASUS Update utility is capable of updating itself through the Internet. Always update the utility to avail all its features. 3. Locate the BIOS file from the Open Open Open Open Open window, then click Save Save Save Save Save . 4. Follow the screen instructions to complete the update process.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-11 5-11 5-11 5-11 5-11 5.2 BIOS setup program This motherboard supports a programmable firmware chip that you can update using the provided utility described in section “ 5.1 Managing and updating your BIOS.” Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to “Run Setup”. This section explains how to configure your system using this utility. Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future. For example, you can enable the security password feature or change the power management settings. This requires you to reconfigure your system using the BIOS Setup program so that the computer can recognize these changes and record them in the CMOS RAM of the firmware hub. The firmware hub on the motherboard stores the Setup utility. When you start up the computer, the system provides you with the opportunity to run this program. Press <Del> during the Power-On-Self-Test (POST) to enter the Setup utility; otherwise, POST continues with its test routines. If you wish to enter Setup after POST, restart the system by pressing <Ctrl Alt Delete>, or by pressing the reset button on the system chassis. You can also restart by turning the system off and then back on. Do this last option only if the first two failed. The Setup program is designed to make it as easy to use as possible. Being a menu-driven program, it lets you scroll through the various sub-menus and make your selections from the available options using the navigation keys. • The default BIOS settings for this motherboard apply for most conditions to ensure optimum performance. If the system becomes unstable after changing any BIOS settings, load the default settings to ensure system compatibility and stability. Select the Load Load Load Load Load Setup Defaults Setup Defaults Setup Defaults Setup Defaults Setup Defaults item under the Exit Menu. See section “5.7 Exit Menu.” • The BIOS setup screens shown in this section are for reference purposes only, and may not exactly match what you see on your screen. • Visit the ASUS website (www.asus.com) to download the latest BIOS file for this motherboard.
5-12 5-12 5-12 5-12 5-12 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup 5.2.2 5.2.2 5.2.2 5.2.2 5.2.2 Menu bar Menu bar Menu bar Menu bar Menu bar The menu bar on top of the screen has the following main items: Main Main Main Main Main For changing the basic system configuration Advanced Advanced Advanced Advanced Advanced For changing the advanced system settings Power Power Power Power Power For changing the advanced power management (APM) configuration Boot Boot Boot Boot Boot For changing the system boot configuration Exit Exit Exit Exit Exit For selecting the exit options and loading default settings To select an item on the menu bar, press the right or left arrow key on the keyboard until the desired item is highlighted. 5.2.3 5.2.3 5.2.3 5.2.3 5.2.3 Navigation keys Navigation keys Navigation keys Navigation keys Navigation keys At the bottom right corner of a menu screen are the navigation keys for that particular menu. Use the navigation keys to select items in the menu and change the settings. 5.2.1 5.2.1 5.2.1 5.2.1 5.2.1 BIOS menu screen BIOS menu screen BIOS menu screen BIOS menu screen BIOS menu screen Some of the navigation keys differ from one screen to another. System Time [11:10:19] System Date [Thu 06/17/2005] Legacy Diskette A [1.44M, 3.5 in] IDE Configuration System Information Navigation keys Navigation keys Navigation keys Navigation keys Navigation keys General help General help General help General help General help Menu bar Menu bar Menu bar Menu bar Menu bar Sub-menu items Sub-menu items Sub-menu items Sub-menu items Sub-menu items Configuration fields Configuration fields Configuration fields Configuration fields Configuration fields Menu items Menu items Menu items Menu items Menu items Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.57 (C)Copyright 1985-2004, American Megatrends, Inc. Use [ENTER]. [TAB], or [SHIFT-TAB] to select a field. Use [ ] or [-] to configure system time. BIOS SETUP UTILITY Main Advanced Power Boot Exit
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-13 5-13 5-13 5-13 5-13 5.2.4 5.2.4 5.2.4 5.2.4 5.2.4 Menu items Menu items Menu items Menu items Menu items The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main Main Main Main Main shows the Main menu items. The other items (Advanced, Power, Boot, and Exit) on the menu bar have their respective menu items. 5.2.5 5.2.5 5.2.5 5.2.5 5.2.5 Sub-menu items Sub-menu items Sub-menu items Sub-menu items Sub-menu items A solid triangle before each item on any menu screen means that the iteam has a sub-menu. To display the sub-menu, select the item and press <Enter>. 5.2.6 5.2.6 5.2.6 5.2.6 5.2.6 Configuration fields Configuration fields Configuration fields Configuration fields Configuration fields These fields show the values for the menu items. If an item is user- configurable, you can change the value of the field opposite the item. You cannot select an item that is not user-configurable. A configurable field is enclosed in brackets, and is highlighted when selected. To change the value of a field, select it then press <Enter> to display a list of options. Refer to “5.2.7 Pop-up window.” 5.2.7 5.2.7 5.2.7 5.2.7 5.2.7 Pop-up window Pop-up window Pop-up window Pop-up window Pop-up window Select a menu item then press <Enter> to display a pop-up window with the configuration options for that item. 5.2.8 5.2.8 5.2.8 5.2.8 5.2.8 Scroll bar Scroll bar Scroll bar Scroll bar Scroll bar A scroll bar appears on the right side of a menu screen when there are items that do not fit on the screen. Press the Up/Down arrow keys or <Page Up> /<Page Down> keys to display the other items on the screen. 5.2.9 5.2.9 5.2.9 5.2.9 5.2.9 General help General help General help General help General help At the top right corner of the menu screen is a brief description of the selected item. Main menu items Main menu items Main menu items Main menu items Main menu items System Time [11:10:19] System Date [Thu 06/17/2005] Legacy Diskette A[1.44M, 3.5 in] IDE Configuration System Information BIOS SETUP UTILITY Main Advanced Server Security Boot Exit Use [ENTER], [TAB], or [SHIFT-TAB] to select a field. Use [ ] or [-] to configure system time. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit APM Configuration Power Management/APM [Enabled] Video Power Down Mode [Suspend] Hard Disk Power Down Mode [Suspend] Suspend Time Out(Minute) [Disabled] Throttle Slow Clock Ratio [50%] Power Button Function [On/Off] Restore on AC Power Loss [Power Off] Power On by PS/2 Keyboard [Disabled] Power On by PS/2 Mouse [Disabled] Power On Ring [Disabled] Power On PME# [Disabled] Power On RTC Alarm [Disabled] Use [ENTER], [TAB], or [SHIFT-TAB] to select a field. Use [ ] or [-] to configure system time. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit BIOS SETUP UTILITY Advanced Scroll bar Scroll bar Scroll bar Scroll bar Scroll bar Pop-up window Pop-up window Pop-up window Pop-up window Pop-up window
5-14 5-14 5-14 5-14 5-14 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup 5.3 Main menu When you enter the BIOS Setup program, the Main Main Main Main Main menu screen appears, giving you an overview of the basic system information. 5.3.1 5.3.1 5.3.1 5.3.1 5.3.1 System Time [xx:xx:xx] System Time [xx:xx:xx] System Time [xx:xx:xx] System Time [xx:xx:xx] System Time [xx:xx:xx] Allows you to set the system time. 5.3.2 5.3.2 5.3.2 5.3.2 5.3.2 System Date [Day xx/xx/xxxx] System Date [Day xx/xx/xxxx] System Date [Day xx/xx/xxxx] System Date [Day xx/xx/xxxx] System Date [Day xx/xx/xxxx] Allows you to set the system date. 5.3.3 5.3.3 5.3.3 5.3.3 5.3.3 Legacy Diskette A [1.44M, 3.5 in.] Legacy Diskette A [1.44M, 3.5 in.] Legacy Diskette A [1.44M, 3.5 in.] Legacy Diskette A [1.44M, 3.5 in.] Legacy Diskette A [1.44M, 3.5 in.] Sets the type of floppy drive installed. Configuration options: [Disabled] [360K, 5.25 in.] [1.2M , 5.25 in.] [720K , 3.5 in.] [1.44M, 3.5 in.] [2.88M, 3.5 in.] Refer to section “5.2.1 BIOS menu screen” for information on the menu screen items and how to navigate through them. System Time [11:10:19] System Date [Thu 06/17/2005] Legacy Diskette A [1.44M, 3.5 in] IDE Configuration System Information Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. Use [ENTER]. [TAB], or [SHIFT-TAB] to select a field. Use [ ] or [-] to configure system time. BIOS SETUP UTILITY Main Advanced Power Boot Exit
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-15 5-15 5-15 5-15 5-15 ATA/IDE Configuration [Compatible Mode] ATA/IDE Configuration [Compatible Mode] ATA/IDE Configuration [Compatible Mode] ATA/IDE Configuration [Compatible Mode] ATA/IDE Configuration [Compatible Mode] Allows selection of the IDE operation mode depending on the installed operating system (OS). Set to [Enhanced Mode] if you are using native OS, e.g. Windows ® 2000/XP. Set to [Compatible Mode] if you are using legacy OS, e.g. Windows ME/98/NT, MS-DOS. Configuration options: [Disabled] [Compatible Mode] [Enhanced Mode] 5.3.4 5.3.4 5.3.4 5.3.4 5.3.4 IDE Configuration IDE Configuration IDE Configuration IDE Configuration IDE Configuration The items in this menu allow you to set or change the configurations for the IDE devices installed in the system. Select an item then press <Enter> if you want to configure the item. The Configure SATA as Configure SATA as Configure SATA as Configure SATA as Configure SATA as and Third IDE Master/Slave Third IDE Master/Slave Third IDE Master/Slave Third IDE Master/Slave Third IDE Master/Slave options appear only when you set the ATA/IDE Configuration to [Enhanced Mode]. Configure SATA As [IDE] Sets the configuration for the Serial ATA connectors supported by the Southbridge chip. If you want to use the Serial ATA hard disk drives as Parallel ATA physical storage devices, set this item to [IDE]. Set this item to [RAID] if you want to create a RAID 0, RAID 1, RAID 0 1, or software RAID 5 configuration using the Intel ® Matrix Storage Manager or if you want to create a RAID 0, RAID 1, RAID 0 1 configuration using the LSI Logic Embedded SATA RAID Setup Utility. The AHCI allows the onboard storage driver to enable advanced Serial ATA features that increases storage performance on random workloads by allowing the drive to internally optimize the order of commands. IDE Configuration ATA/IDE Configuration [Compatible] Legacy IDE Channels [SATA Pri, PATA Sec] Primary IDE Master : [Not Detected] Primary IDE Slave : [Not Detected] Secondary IDE Master : [Not Detected] Secondary IDE Slave : [Not Detected] IDE Detect Time Out (Sec) [35] Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit BIOS SETUP UTILITY Main v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. Options Disabled Compatible Enhanced
5-16 5-16 5-16 5-16 5-16 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup If you want the Serial ATA hard disk drives to use the Advanced Host Controller Interface (AHCI), set this item to [AHCI]. For details on AHCI, go to: www.intel.com/support/chipsets/imst/sb/CS-012304.htm www.intel.com/support/chipsets/imst/sb/CS-012305.htm The SATA controller is set to Native mode when this item is set to [RAID] or [AHCI]. Legacy IDE Channels [SATA Pri, PATA Sec] Allows you to set Serial ATA, Parallel ATA, or both, to native mode. Configuration options: [SATA Only] [PATA Pri, SATA Sec] [SATA Pri, PATA Sec] [ PATA Only] IDE Detect Time Out (Sec) [35] IDE Detect Time Out (Sec) [35] IDE Detect Time Out (Sec) [35] IDE Detect Time Out (Sec) [35] IDE Detect Time Out (Sec) [35] Selects the time our value (in seconds) for detecting ATA/ATAPI devices. Configuration options: [0] [5] [10] [15] [20] [25] [30] [35] 5.3.5 5.3.5 5.3.5 5.3.5 5.3.5 Primary/Secondary/Third IDE Master/Slave Primary/Secondary/Third IDE Master/Slave Primary/Secondary/Third IDE Master/Slave Primary/Secondary/Third IDE Master/Slave Primary/Secondary/Third IDE Master/Slave The BIOS automatically detects the connected IDE devices. There is a separate sub-menu for each IDE device. Select a device item, then press <Enter> to display the IDE device information. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit BIOS SETUP UTILITY Main v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. Primary IDE Master Device : Hard Disk Vendor : ST320413A Size : 20.0GB LBA Mode : Supported Block Mode : 16 Sectors PIO Mode : Supported Async DMA : MultiWord DMA-2 Ultra DMA : Ultra DMA-5 SMART Monitoring: Supported Type [Auto] LBA/Large Mode [Auto] Block(Multi-sector Transfer) [Auto] PIO Mode [Auto] DMA Mode [Auto] SMART Monitoring [Auto] 32Bit Data Transfer [Enabled] Select the type of device connected to the system. The BIOS automatically detects the values opposite the dimmed items (Device, Vendor, Size, LBA Mode, Block Mode, PIO Mode, Async DMA, Ultra DMA, and SMART monitoring). These values are not user-configurable. These items show N/A if no IDE device is installed in the system.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-17 5-17 5-17 5-17 5-17 Type [Auto] Type [Auto] Type [Auto] Type [Auto] Type [Auto] Selects the type of IDE drive. Setting to [Auto] allows automatic selection of the appropriate IDE device type. Select [CDROM] if you are specifically configuring a CD-ROM drive. Select [ARMD] (ATAPI Removable Media Device) if your device is either a ZIP, LS-120, or MO drive. Configuration options: [Not Installed] [Auto] [CDROM] [ARMD] LBA/Large Mode [Auto] LBA/Large Mode [Auto] LBA/Large Mode [Auto] LBA/Large Mode [Auto] LBA/Large Mode [Auto] Enables or disables the LBA mode. Setting to [Auto] enables the LBA mode if the device supports this mode, and if the device was not previously formatted with LBA mode disabled. Configuration options: [Disabled] [Auto] Block (Multi-sector Transfer) [Auto] Block (Multi-sector Transfer) [Auto] Block (Multi-sector Transfer) [Auto] Block (Multi-sector Transfer) [Auto] Block (Multi-sector Transfer) [Auto] Enables or disables data multi-sectors transfers. When set to [Auto], the data transfer from and to the device occurs multiple sectors at a time if the device supports multi-sector transfer feature. When set to [Disabled], the data transfer from and to the device occurs one sector at a time. Configuration options: [Disabled] [Auto] PIO Mode [Auto] PIO Mode [Auto] PIO Mode [Auto] PIO Mode [Auto] PIO Mode [Auto] Selects the PIO mode. Configuration options: [Auto] [0] [1] [2] [3] [4] DMA Mode [Auto] DMA Mode [Auto] DMA Mode [Auto] DMA Mode [Auto] DMA Mode [Auto] Selects the DMA mode. Configuration options: [Auto] [SWDMA0] [SWDMA1] [SWDMA2] [MWDMA0] [MWDMA1] [MWDMA2] [UDMA0] [UDMA1] [UDMA2] SMART Monitoring [Auto] SMART Monitoring [Auto] SMART Monitoring [Auto] SMART Monitoring [Auto] SMART Monitoring [Auto] Sets the Smart Monitoring, Analysis, and Reporting Technology. Configuration options: [Auto] [Disabled] [Enabled] 32Bit Data Transfer [Enabled] 32Bit Data Transfer [Enabled] 32Bit Data Transfer [Enabled] 32Bit Data Transfer [Enabled] 32Bit Data Transfer [Enabled] Enables or disables 32-bit data transfer. Configuration options: [Disabled] [Enabled]
5-18 5-18 5-18 5-18 5-18 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup 5.3.6 5.3.6 5.3.6 5.3.6 5.3.6 System Information System Information System Information System Information System Information This menu gives you an overview of the general system specifications. The BIOS automatically detects the items in this menu. AMIBIOS Version : 08.00.11 Build Date : 06/14/05 Processor Type : Genuine Intel(R) CPU 3.20GHz Speed : 3200 MHz Count : 1 System Memory Total : 1024MB Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Main AMI BIOS AMI BIOS AMI BIOS AMI BIOS AMI BIOS Displays the auto-detected BIOS information. Processor Processor Processor Processor Processor Displays the auto-detected CPU specification. System Memory System Memory System Memory System Memory System Memory Displays the auto-detected total system memory.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-19 5-19 5-19 5-19 5-19 5.4 Advanced menu The Advanced menu items allow you to change the settings for the CPU and other system devices. Take caution when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction. 5.4.1 5.4.1 5.4.1 5.4.1 5.4.1 MPS Configuration MPS Configuration MPS Configuration MPS Configuration MPS Configuration Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Advanced Select MPS Revision. MPS Configuration MPS Revision [1.1] Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Advanced Configure the Multi- Processor Table. MPS Configuration Remote Access Configuration CPU Configuration Chipset Onboard Devices Configuration PCI/PnP MPS Revision [1.4] MPS Revision [1.4] MPS Revision [1.4] MPS Revision [1.4] MPS Revision [1.4] Allows you to select the multi-processor system version. Configuration options: [1.1] [1.4]
5-20 5-20 5-20 5-20 5-20 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup 5.4.2 5.4.2 5.4.2 5.4.2 5.4.2 Remote Access Configuration Remote Access Configuration Remote Access Configuration Remote Access Configuration Remote Access Configuration Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Advanced Select Remote Access type. Configure Remote Access type and parameters Remote Access [Enabled] Serial port number [COM1] Base Address, IRQ [3F8h, 4] Serial Port Mode [115200 8,n,1] Flow Control [None] Redirection After BIOS POST [Always] Terminal Type [ANSI] VT-UTFB Combo Key Support [Disabled] Sredir Memory Display Delay [No Delay] Remote Access [Enabled] Remote Access [Enabled] Remote Access [Enabled] Remote Access [Enabled] Remote Access [Enabled] Allows you to enable or disable remote access. Configuration options: [Disabled] [Enabled] When the Remote Access Remote Access Remote Access Remote Access Remote Access item is set to [Disabled], all other items do not appear. Serial port number [COM1] Serial port number [COM1] Serial port number [COM1] Serial port number [COM1] Serial port number [COM1] Enables or disables the remote access feature. Configuration options: [Disabled] [Enabled] Serial Port Mode [115200 8,n,1] Serial Port Mode [115200 8,n,1] Serial Port Mode [115200 8,n,1] Serial Port Mode [115200 8,n,1] Serial Port Mode [115200 8,n,1] Sets the Serial port mode. Configuration options: [115200 8,n,1] [57600 8,n,1] [38400 8,n,1] [19200 8,n,1] [09600 8,n,1] Flow Control [None] Flow Control [None] Flow Control [None] Flow Control [None] Flow Control [None] Allows you to select the flow control for console redirection. Configuration options: [None] [Hardware] [Software] Redirection After BIOS POST [Always] Redirection After BIOS POST [Always] Redirection After BIOS POST [Always] Redirection After BIOS POST [Always] Redirection After BIOS POST [Always] Sets the redirection mode after the BIOS Power-On Self-Test (POST). Some operating systems may not work when this item is set to Always. Configuration options: [Disabled] [Boot Loader] [Always] Terminal Type [ANSI] Terminal Type [ANSI] Terminal Type [ANSI] Terminal Type [ANSI] Terminal Type [ANSI] Allows you to select the target terminal type. Configuration options: [ANSI] [VT100] [VT-UTF8]
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-21 5-21 5-21 5-21 5-21 Max CPUID Value Limit [Disabled] Max CPUID Value Limit [Disabled] Max CPUID Value Limit [Disabled] Max CPUID Value Limit [Disabled] Max CPUID Value Limit [Disabled] Setting this item to [Enabled] allows legacy operating systems to boot even without support for CPUs with extended CPUID functions. Configuration options: [Disabled] [Enabled] 5.4.3 5.4.3 5.4.3 5.4.3 5.4.3 CPU Configuration CPU Configuration CPU Configuration CPU Configuration CPU Configuration The items in this menu show the CPU-related information that the BIOS automatically detects. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Advanced Sets the ratio between CPU Core Clock and the FSB Frequency. NOTE: If an invalid ratio is set in CMOS then actual and setpoint values may differ. Configure advanced CPU settings Module Version: 3C.0B Manufacturer: Intel Brand String: Genuine Intel(R) CPU 3.20GHz Frequency : 3.40 GHz FSB Speed : 800 MHz Cache L1 : 16 KB Cache L2 : 1024 KB Ratio Status: Unlocked (Max:17, Min:14) Ratio Actual Value : 17 Ratio CMOS Setting: [ 16] Max CPUID Value Limit: [Disabled] Hyper Threading Technology [Enabled] Ratio CMOS Setting [16] Ratio CMOS Setting [16] Ratio CMOS Setting [16] Ratio CMOS Setting [16] Ratio CMOS Setting [16] Sets the ratio between the CPU core clock and the Front Side Bus frequency. The BIOS auto-detects the default value of this item. Use the < > < > < > < > < > or <-> <-> <-> <-> < - > keys to adjust the values. Configuration options: [ 8]...[28] You can only adjust the Ratio CMOS Ratio CMOS Ratio CMOS Ratio CMOS Ratio CMOS setting if you installed an unlocked CPU. Refer to the CPU documentation for details. VT-UTF8 Combo Key Support [Disabled] VT-UTF8 Combo Key Support [Disabled] VT-UTF8 Combo Key Support [Disabled] VT-UTF8 Combo Key Support [Disabled] VT-UTF8 Combo Key Support [Disabled] Enables or disables the VT-UTF8 combo key support for ANSI or VT100 terminals. Configuration options: [Disabled] [Enabled] Sredir Memory Display Delay [No Delay] Sredir Memory Display Delay [No Delay] Sredir Memory Display Delay [No Delay] Sredir Memory Display Delay [No Delay] Sredir Memory Display Delay [No Delay] Allows you to set the delay to display the memory information. Configuration options: [No Delay] [Delay 1 Sec] [Delay 2 Sec] [Delay 4 Sec]
5-22 5-22 5-22 5-22 5-22 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup The Hyper-Threading Technology item appears only when you installed an Intel ® Pentium ® 4 CPU that supports the Hyper-Threading Technology. Hyper-Threading is not supported when you installed a dual-core CPU. Hyper-Threading Technology [Enabled] Hyper-Threading Technology [Enabled] Hyper-Threading Technology [Enabled] Hyper-Threading Technology [Enabled] Hyper-Threading Technology [Enabled] Allows you to enable or disable the processor Hyper-Threading Technology. Refer to the Appendix for more information on the Hyper-Threading Technology. Configuration options: [Disabled] [Enabled] The following items appear only when you installed an Intel ® Pentium ® 4 dual-core CPU. Execute Disable Bit [Enabled] Execute Disable Bit [Enabled] Execute Disable Bit [Enabled] Execute Disable Bit [Enabled] Execute Disable Bit [Enabled] When this item is set to [Disabled], the BIOS forces the XD feature flag to always return to (0). Configuration options: [Enabled] [Disabled] C1E Support [Disabled] C1E Support [Disabled] C1E Support [Disabled] C1E Support [Disabled] C1E Support [Disabled] When set to [Enabled], the BIOS will automatically check the CPU’s capability to enable the C1E support. In C1E mode, the CPU power consumption is lower when idle. Configuration options: [Disabled] [Enabled] Single Logical Processor Mode [Disabled] Single Logical Processor Mode [Disabled] Single Logical Processor Mode [Disabled] Single Logical Processor Mode [Disabled] Single Logical Processor Mode [Disabled] Allows you to enable or disable the single logical processor mode for dual-core CPUs. Configuration options: [Disabled] [Enabled] Intel(R) SpeedStep Technology [Automatic] Intel(R) SpeedStep Technology [Automatic] Intel(R) SpeedStep Technology [Automatic] Intel(R) SpeedStep Technology [Automatic] Intel(R) SpeedStep Technology [Automatic] Allows you to use the Enhanced Intel SpeedStep ® Technology. When set to [Automatic], you can adjust the system power settings in the operating system to use the EIST feature. Set this item to [Disabled] i f you do not want to use the EIST. Configuration options: [Automatic] [Disabled] • Refer to the Appendix for details on how to use the EIST feature. • The motherboard comes with a BIOS file that supports EIST.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-23 5-23 5-23 5-23 5-23 Onboard LAN Boot ROM [Enabled] Onboard LAN Boot ROM [Enabled] Onboard LAN Boot ROM [Enabled] Onboard LAN Boot ROM [Enabled] Onboard LAN Boot ROM [Enabled] Allows you to enable or disable the option ROM in the onboard LAN controller. Configuration options: [Disabled] [Enabled] 5.4.4 5.4.4 5.4.4 5.4.4 5.4.4 Chipset Configuration Chipset Configuration Chipset Configuration Chipset Configuration Chipset Configuration The Chipset Configuration menu allows you to change the advanced chipset settings. Select an item then press <Enter> to display the sub-menu. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Advanced Configure North Bridge features. Advanced Chipset Settings WARNING: Setting wrong values in below sections may cause system to malfunction. North Bridge Configuration South Bridge Configuration Intel PCI-X Hub Configuration Onboard LAN Boot ROM [Enabled]
5-24 5-24 5-24 5-24 5-24 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Memory Remap Feature [Enabled] Memory Remap Feature [Enabled] Memory Remap Feature [Enabled] Memory Remap Feature [Enabled] Memory Remap Feature [Enabled] Allows you to remap the overlap PCI memory over the total physical memory. Configuration options: [Disabled] [Enabled] DRAM Frequency [Auto] DRAM Frequency [Auto] DRAM Frequency [Auto] DRAM Frequency [Auto] DRAM Frequency [Auto] Allows you to set the DDR operating frequency. Configuration options: [Auto] [533 MHz] [667 Mhz] Configure DRAM Timing by SPD [Enabled] Configure DRAM Timing by SPD [Enabled] Configure DRAM Timing by SPD [Enabled] Configure DRAM Timing by SPD [Enabled] Configure DRAM Timing by SPD [Enabled] When this item is enabled, the DRAM timing parameters are set according to the DRAM SPD (Serial Presence Detect). When disabled, you can manually set the DRAM timing parameters through the DRAM sub-items. The following sub-items appear when this item is Disabled. Configuration options: [Disabled] [Enabled] DRAM CAS# Latency [5 Clocks] Controls the latency between the SDRAM read command and the time the data actually becomes available. Configuration options: [5] [4] [3] DRAM RAS# to CAS# Delay [6 DRAM Clocks] Controls the latency between the DDR SDRAM active command and the read/write command. Configuration options: [2 DRAM Clocks] [3 DRAM Clocks] [4 DRAM Clocks] [5 DRAM Clocks] [6 DRAM Clocks] NorthBridge Configuration NorthBridge Configuration NorthBridge Configuration NorthBridge Configuration NorthBridge Configuration The NorthBridge Configuration menu allows you to change the Northbridge related settings. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Advanced ENABLE: Allow remapping of overlapped PCI memory above the total physical memory. DISABLE: Do not allow remapping of memory. North Bridge Chipset Configuration Memory Remap Feature [Enabled] DRAM Frequency [Auto] Configure DRAM Timing by SPD [Enabled] Boots Graphic Adapter Priority [PEG/PCI] PEG Port Configuration PEG Port [Auto]
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-25 5-25 5-25 5-25 5-25 DRAM RAS# Precharge [6 DRAM Clocks] Controls the idle clocks after issuing a precharge command to the DDR SDRAM. Configuration options: [2 DRAM Clocks] [3 DRAM Clocks] [4 DRAM Clocks] [5 DRAM Clocks] [6 DRAM Clocks] DRAM RAS# Activate to Precharge [15 DRAM Clocks] Configuration options: [4 DRAM Clocks] [5 DRAM Clocks] ~ [15 DRAM Clocks] Boots Graphic Adapter Priority [PEG/PCI] Boots Graphic Adapter Priority [PEG/PCI] Boots Graphic Adapter Priority [PEG/PCI] Boots Graphic Adapter Priority [PEG/PCI] Boots Graphic Adapter Priority [PEG/PCI] Allows selection of the graphics controller to use as primary boot device. Configuration options: [PCI/PEG] [PEG/PCI] PEG Port Configuration PEG Port Configuration PEG Port Configuration PEG Port Configuration PEG Port Configuration PEG Port [Auto] Allows you to set or disable the PCI Express Graphic port. Configuration options: [Auto] [Disabled] SouthBridge Configuration SouthBridge Configuration SouthBridge Configuration SouthBridge Configuration SouthBridge Configuration The SouthBridge Configuration menu allows you to change the Southbridge related settings. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Advanced South Bridge Chipset Configuration USB Functions [4 USB Ports] USB 2.0 Controller [Enabled] PCIE Ports Configuration PCI Express Port 0 [Auto] PCI Express Port 4 [Auto] PCI Express Port 5 [Auto] USB Function [4 USB Ports] USB Function [4 USB Ports] USB Function [4 USB Ports] USB Function [4 USB Ports] USB Function [4 USB Ports] Allows you to enable a specific number of USB ports, or disable the USB function. Configuration options: [Disabled] [2 USB Ports] [4 USB Ports] USB 2.0 Controller [Enabled] USB 2.0 Controller [Enabled] USB 2.0 Controller [Enabled] USB 2.0 Controller [Enabled] USB 2.0 Controller [Enabled] Allows you to enable or disable the USB 2.0 controller. Configuration options: [Enabled] [Disabled] Options Disabled 2 USB Ports 4 USB Ports
5-26 5-26 5-26 5-26 5-26 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup PCIE Port Configuration PCIE Port Configuration PCIE Port Configuration PCIE Port Configuration PCIE Port Configuration PCI Express Port 0 [Auto] Allows you to set or disable the PCI Express Port 0. Configuration options: [Auto] [Disabled] PCI Express Port 4 [Auto] Allows you to set or disable the PCI Express Port 4. Configuration options: [Auto] [Disabled] PCI Express Port 5 [Auto] Allows you to set or disable the PCI Express Port 5. Configuration options: [Auto] [Disabled] Intel PCI-X Hub Configuration Intel PCI-X Hub Configuration Intel PCI-X Hub Configuration Intel PCI-X Hub Configuration Intel PCI-X Hub Configuration The Intel PCI-X Hub Configuration menu allows you to change the Intel PCI Express controller related settings. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Advanced Configure advanced settings for PCI-X Hub I/O Port Decode [4K Decode] VGA 16-Bit Decode [Enabled] Select the decode range for IO. I/O Port Decode [4K Decode] I/O Port Decode [4K Decode] I/O Port Decode [4K Decode] I/O Port Decode [4K Decode] I/O Port Decode [4K Decode] Allows you to set the decode range for the I/O controller. Configuration options: [4K Decode] [1K Decode] VGA 16-Bit Decode [Enabled] VGA 16-Bit Decode [Enabled] VGA 16-Bit Decode [Enabled] VGA 16-Bit Decode [Enabled] VGA 16-Bit Decode [Enabled] Allows you to enable or disable the decode for the VGA controller. Configuration options: [Disabled] [Enabled]
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-27 5-27 5-27 5-27 5-27 5.4.5 5.4.5 5.4.5 5.4.5 5.4.5 Onboard Devices Configuration Onboard Devices Configuration Onboard Devices Configuration Onboard Devices Configuration Onboard Devices Configuration Onboard Floppy Controller [Enabled] Onboard Floppy Controller [Enabled] Onboard Floppy Controller [Enabled] Onboard Floppy Controller [Enabled] Onboard Floppy Controller [Enabled] Allows you to enable the onboard floppy disk drive controller. Configuration options: [Disabled] [Enabled] Serial Port1 Address [3F8/IRQ4] Serial Port1 Address [3F8/IRQ4] Serial Port1 Address [3F8/IRQ4] Serial Port1 Address [3F8/IRQ4] Serial Port1 Address [3F8/IRQ4] Allows you to select the Serial Port1 base address. Configuration options: [Disabled] [3F8/IRQ4] [3E8/IRQ4] [2E8/IRQ3] Serial Port2 Address [2F8/IRQ3] Serial Port2 Address [2F8/IRQ3] Serial Port2 Address [2F8/IRQ3] Serial Port2 Address [2F8/IRQ3] Serial Port2 Address [2F8/IRQ3] Allows you to select the Serial Port2 base address. Configuration options: [Disabled] [2F8/IRQ3] [3E8/IRQ4] [2E8/IRQ3] Serial Port2 Mode [Normal] Allows you to select the Serial Port2 mode. Configuration options: [Normal] [IrDA] [ASK IR] Parallel Port Address [378] Parallel Port Address [378] Parallel Port Address [378] Parallel Port Address [378] Parallel Port Address [378] Allows you to select the Parallel Port base addresses. Configuration options: [Disabled] [378] [278] [3BC] Parallel Port Mode [Normal] Parallel Port Mode [Normal] Parallel Port Mode [Normal] Parallel Port Mode [Normal] Parallel Port Mode [Normal] Allows you to select the Parallel Port mode. Configuration options: [Normal] [Bi-directional] [EPP] [ECP] Parallel Port IRQ [IRQ7] Allows you to specify the Parallel Port IRQ. Configuration options: [IRQ5] [IRQ7] Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Advanced Allows BIOS to Enable or Disable Floppy Controller Configure W83627EHF-A Super IO Chipset Onboard Floppy Controller [Enabled] Serial Port1 Address [3F8/IRQ4] Serial Port2 Address [2F8/IRQ3] Serial Port2 Mode [Normal] Parallel Port Address [378] Parallel Port Mode [Normal] Parallel Port IRQ [IRQ7]
5-28 5-28 5-28 5-28 5-28 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup 5.4.6 5.4.6 5.4.6 5.4.6 5.4.6 PCI/PnP Configuration PCI/PnP Configuration PCI/PnP Configuration PCI/PnP Configuration PCI/PnP Configuration The PCI/PnP Configuration menu items allow you to change the advanced settings for PCI/PnP devices. The menu includes setting the IRQ and DMA channel resources for either PCI/PnP or legacy ISA devices, and setting the memory size block for legacy ISA devices. Plug And Play O/S [No] Plug And Play O/S [No] Plug And Play O/S [No] Plug And Play O/S [No] Plug And Play O/S [No] When set to [No], BIOS configures all the devices in the system. When set to [Yes] and if you install a Plug and Play operating system, the operating system configures the Plug and Play devices not required for boot. Configuration options: [No] [Yes] PCI Latency Timer [64] PCI Latency Timer [64] PCI Latency Timer [64] PCI Latency Timer [64] PCI Latency Timer [64] Allows you to select the value in units of PCI clocks for the PCI device latency timer register. Configuration options: [32] [64] [96] [128] [160] [192] [224] [248] Allocate IRQ to PCI VGA [Yes] Allocate IRQ to PCI VGA [Yes] Allocate IRQ to PCI VGA [Yes] Allocate IRQ to PCI VGA [Yes] Allocate IRQ to PCI VGA [Yes] When set to [Yes], BIOS assigns an IRQ to PCI VGA card if the card requests for an IRQ. When set to [No], BIOS does not assign an IRQ to the PCI VGA card even if requested. Configuration options: [Yes] [No] Palette Snooping [Disabled] Palette Snooping [Disabled] Palette Snooping [Disabled] Palette Snooping [Disabled] Palette Snooping [Disabled] When set to [Enabled], the pallete snooping feature informs the PCI devices that an ISA graphics device is installed in the system so that the latter can function correctly. Configuration options: [Disabled] [Enabled] IRQXX assigned to [PCI Device] IRQXX assigned to [PCI Device] IRQXX assigned to [PCI Device] IRQXX assigned to [PCI Device] IRQXX assigned to [PCI Device] When set to [PCI Device], the specific IRQ is free for use of PCI/PnP devices. When set to [Reserved], the IRQ is reserved for legacy devices. Configuration options: [PCI Device] [Reserved] Take caution when changing the settings of the PCI PnP menu items. Incorrect field values can cause the system to malfunction! Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Advanced NO: Lets the BIOS configure all the devices int he system. YES: Lets the operating system configure Plug and Play (PnP) devices not required for boot if your system has a Plug ans Play operating system. Advanced PCI/PnP Settings Plug and Play OS [No] PCI Latency Timer [64] Allocate IRQ to PCI VGA [Yes] Pallete Snooping [Disabled] IRQ3 assigned to [PCI Device] IRQ4 assigned to [PCI Device] IRQ5 assigned to [PCI Device] IRQ7 assigned to [PCI Device] IRQ9 assigned to [PCI Device] IRQ10 assigned to [PCI Device] IRQ11 assigned to [PCI Device] IRQ14 assigned to [PCI Device] IRQ15 assigned to [PCI Device]
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-29 5-29 5-29 5-29 5-29 5.5.1 5.5.1 5.5.1 5.5.1 5.5.1 APM Configuration APM Configuration APM Configuration APM Configuration APM Configuration Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. Enable or disable APM. APM Configuration Power Management/APM [Enabled] Video Power Down Mode [Suspend] Hard Disk Power Down Mode [Suspend] Standby Time Out [Disabled] Suspend Time Out [Disabled] Throttle Slow Clock Ratio [50%] System Thermal [Disabled] Power Button Mode [On/Off] Restore on AC Power Loss [Last State] Resume On Ring [Disabled] Resume On LAN [Disabled] Resume On PME# [Disabled] Resume On RTC Alarm [Disabled] Power On By PS/2 Keyboard [Disabled] Power On By PS/2 Mouse [Disabled] 5.5 Power menu The Power menu items allow you to change the settings for the ACPI and Advanced Power Management (APM) features. Select an item then press <Enter> to display the configuration options. ACPI APIC Support [Enabled] ACPI APIC Support [Enabled] ACPI APIC Support [Enabled] ACPI APIC Support [Enabled] ACPI APIC Support [Enabled] Allows you to enable or disable the Advanced Configuration and Power Interface (ACPI) support in the Application-Specific Integrated Circuit (ASIC). When set to Enabled, the ACPI APIC table pointer is included in the RSDT pointer list. Configuration options: [Disabled] [Enabled] Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Main Advanced Power Boot Exit Include ACPI APIC table pointer to RSDT pointer list. ACPI APIC Support [Enabled] APM Configuration Hardware Monitor BIOS SETUP UTILITY Power Power Management [Enabled] Power Management [Enabled] Power Management [Enabled] Power Management [Enabled] Power Management [Enabled] Allows you to enable or disable the motherboard Advance Power Management (APM) feature. Configuration options: [Enabled] [Disabled]
5-30 5-30 5-30 5-30 5-30 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Video Power Down Mode [Suspend] Video Power Down Mode [Suspend] Video Power Down Mode [Suspend] Video Power Down Mode [Suspend] Video Power Down Mode [Suspend] Allows you to select the video power down mode Configuration options: [Disabled] [Standby] [Suspend] Hard Disk Power Down Mode [Suspend] Hard Disk Power Down Mode [Suspend] Hard Disk Power Down Mode [Suspend] Hard Disk Power Down Mode [Suspend] Hard Disk Power Down Mode [Suspend] Allows you to select the hard disk power down mode Configuration options: [Disabled] [Standby] [Suspend] Suspend Time Out (Minute) [Disabled] Suspend Time Out (Minute) [Disabled] Suspend Time Out (Minute) [Disabled] Suspend Time Out (Minute) [Disabled] Suspend Time Out (Minute) [Disabled] Allows you to select the specified time at which the system goes on suspend mode. Configuration options: [Disabled] [1 Min] [2 Min] [4 Min] [8 Min] [10 Min] [20 Min] [30 Min] [40 Min] [50 Min] [60 Min] Throttle Slow Clock Ratio [50%] Throttle Slow Clock Ratio [50%] Throttle Slow Clock Ratio [50%] Throttle Slow Clock Ratio [50%] Throttle Slow Clock Ratio [50%] Allows you to select duty cycle in throttle mode. Configuration options: [87.5%] [75.0%] [62.5%] [50.0%] [37.5%] [25.0%] [12.5%] System Thermal [Disabled] System Thermal [Disabled] System Thermal [Disabled] System Thermal [Disabled] System Thermal [Disabled] Allows you to enable or disable the system thermal control feature. Configuration options: [Disabled] [Enabled] The Thermal Active Temperature Thermal Active Temperature Thermal Active Temperature Thermal Active Temperature Thermal Active Temperature and Thermal Slow Clock Thermal Slow Clock Thermal Slow Clock Thermal Slow Clock Thermal Slow Clock Ratio Ratio Ratio Ratio Ratio items appear only when the System Thermal System Thermal System Thermal System Thermal System Thermal item is set to Enabled. Thermal Active Temperature [60ºC/140ºF] Thermal Active Temperature [60ºC/140ºF] Thermal Active Temperature [60ºC/140ºF] Thermal Active Temperature [60ºC/140ºF] Thermal Active Temperature [60ºC/140ºF] Allows you to specify the system thermal control activating temperature. Configuration options: [40ºC/104ºF] [45ºC/1113ºF] [50ºC/122ºF] [55ºC/131ºF] [60ºC/140ºF] [65ºC/149ºF] [70ºC/158ºF] [75ºC/167ºF] Thermal Slow Clock Ratio [50%] Thermal Slow Clock Ratio [50%] Thermal Slow Clock Ratio [50%] Thermal Slow Clock Ratio [50%] Thermal Slow Clock Ratio [50%] Allows you to select the duty cycle in throttle when a thermal override condition occurs. Configuration options: [87.5%] [75.0%] [62.5%] [50%] [37.5%] [25%] [12.5%] Power Button Mode [On/Off] Power Button Mode [On/Off] Power Button Mode [On/Off] Power Button Mode [On/Off] Power Button Mode [On/Off] Allows the system to go into On/Off mode or suspend mode when the power button is pressed. Configuration options: [On/Off] [Suspend]
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-31 5-31 5-31 5-31 5-31 Restore on AC Power Loss [Last State] Restore on AC Power Loss [Last State] Restore on AC Power Loss [Last State] Restore on AC Power Loss [Last State] Restore on AC Power Loss [Last State] When set to Power Off, the system goes into off state after an AC power loss. When set to Power On, the system goes on after an AC power loss. When set to Last State, the system goes into either off or on state, whatever the system state was before the AC power loss. Configuration options: [Power Off] [Power On] [Last State] Resume On Ring [Disabled] Resume On Ring [Disabled] Resume On Ring [Disabled] Resume On Ring [Disabled] Resume On Ring [Disabled] When set to [Enabled], the system enables the RI to generate a wake event while the computer is in Soft-off mode. Configuration options: [Disabled] [Enabled] Resume On LAN [Disabled] Resume On LAN [Disabled] Resume On LAN [Disabled] Resume On LAN [Disabled] Resume On LAN [Disabled] When set to [Enabled], the system enables the LAN to generate a wake event while the computer is in Soft-off mode. Configuration options: [Disabled] [Enabled] Resume On PME# [Disabled] Resume On PME# [Disabled] Resume On PME# [Disabled] Resume On PME# [Disabled] Resume On PME# [Disabled] When set to [Enabled], the system enables the PME to generate a wake event while the computer is in Soft-off mode. Configuration options: [Disabled] [Enabled] Resume On RTC Alarm [Disabled] Resume On RTC Alarm [Disabled] Resume On RTC Alarm [Disabled] Resume On RTC Alarm [Disabled] Resume On RTC Alarm [Disabled] Allows you to enable or disable RTC to generate a wake event. Configuration options: [Disabled] [Enabled] The following items appear when the Power On RTC Alarm Power On RTC Alarm Power On RTC Alarm Power On RTC Alarm Power On RTC Alarm item is set to Enabled. RTC Alarm Date (Days) To set the alarm date, highlight this item and press the < > or <-> key to make the selection. Configuration options: [Everyday] [1] [2] [3]... ~ [31] System Time To set the alarm hour, highlight this item and press the < > or <-> key to make the selection. Configuration options: [00] [1]... ~ [23]
5-32 5-32 5-32 5-32 5-32 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup 5.5.2 5.5.2 5.5.2 5.5.2 5.5.2 Hardware Monitor Hardware Monitor Hardware Monitor Hardware Monitor Hardware Monitor CPU1 Temperature [xxxºC/xxxºF] CPU1 Temperature [xxxºC/xxxºF] CPU1 Temperature [xxxºC/xxxºF] CPU1 Temperature [xxxºC/xxxºF] CPU1 Temperature [xxxºC/xxxºF] MB Temperature [xxxºC/xxxºF] MB Temperature [xxxºC/xxxºF] MB Temperature [xxxºC/xxxºF] MB Temperature [xxxºC/xxxºF] MB Temperature [xxxºC/xxxºF] The onboard hardware monitor automatically detects and displays the motherboard and CPU temperatures. Select [Disabled] if you do not wish to display the detected temperatures. Use the down arrow key to display additional items. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. CPU1 Temperature. Hardware Monitor CPU1 Temperature [49ºC/120ºF] MB Temperature [39ºC/102ºF] CPU Fan1 Speed [5038RPM] CPU Fan2 Speed [5045RPM] Front Fan1 Speed [N/A] Front Fan2 Speed [N/A] Rear Fan1 Speed [N/A] Rear Fan2 Speed [N/A] Smart Fan Control [Enabled] CPU1 Temperature [60] MB Temperature [50] VCORE1 Voltage [ 1.236V] VCORE2 Voltage [ 1.258V] 3.3V Voltage [ 3.280V] 5V Voltage [ 5.010V] Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. 5VSB Voltage [ 4.980V] VBAT Voltage [ 3.088V] 12V Voltage [11.749V] BIOS SETUP UTILITY Power Power On By PS/2 Keyboard [Disabled] Power On By PS/2 Keyboard [Disabled] Power On By PS/2 Keyboard [Disabled] Power On By PS/2 Keyboard [Disabled] Power On By PS/2 Keyboard [Disabled] Allows you to use specific keys on the keyboard to turn on the system. This feature requires an ATX power supply that provides at least 1A on the 5VSB lead. Configuration options: [Disabled] [Enabled] Power On By PS/2 Mouse [Disabled] Power On By PS/2 Mouse [Disabled] Power On By PS/2 Mouse [Disabled] Power On By PS/2 Mouse [Disabled] Power On By PS/2 Mouse [Disabled] When set to [Enabled], this parameter allows you to use the PS/2 mouse to turn on the system. This feature requires an ATX power supply that provides at least 1A on the 5VSB lead. Configuration options: [Disabled] [Enabled]
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-33 5-33 5-33 5-33 5-33 CPU Fan1/2 Speed [xxxxRPM] or [N/A] CPU Fan1/2 Speed [xxxxRPM] or [N/A] CPU Fan1/2 Speed [xxxxRPM] or [N/A] CPU Fan1/2 Speed [xxxxRPM] or [N/A] CPU Fan1/2 Speed [xxxxRPM] or [N/A] Front Fan1/2 Speed [xxxxRPM] or [N/A] Front Fan1/2 Speed [xxxxRPM] or [N/A] Front Fan1/2 Speed [xxxxRPM] or [N/A] Front Fan1/2 Speed [xxxxRPM] or [N/A] Front Fan1/2 Speed [xxxxRPM] or [N/A] Rear Fan1/2 Speed [xxxxRPM] or [N/A] Rear Fan1/2 Speed [xxxxRPM] or [N/A] Rear Fan1/2 Speed [xxxxRPM] or [N/A] Rear Fan1/2 Speed [xxxxRPM] or [N/A] Rear Fan1/2 Speed [xxxxRPM] or [N/A] The onboard hardware monitor automatically detects and displays the CPU, front, and rear fan speeds in rotations per minute (RPM). If a fan is not connected to the connector on the motherboard, the field shows N/A. Smart Fan Control [Enabled] Smart Fan Control [Enabled] Smart Fan Control [Enabled] Smart Fan Control [Enabled] Smart Fan Control [Enabled] Allows you to enable or disable the ASUS Q-Fan feature that smartly adjusts the fan speeds for more efficient system operation. Configuration options: [Disabled] [Enabled] The CPU1 Temperature CPU1 Temperature CPU1 Temperature CPU1 Temperature CPU1 Temperature a n d MB Temperature MB Temperature MB Temperature MB Temperature MB Temperature items do not appear when you disable the Smart Fan Control Smart Fan Control Smart Fan Control Smart Fan Control Smart Fan Control feature. CPU1 Temperature [XXX] CPU1 Temperature [XXX] CPU1 Temperature [XXX] CPU1 Temperature [XXX] CPU1 Temperature [XXX] MB Temperature [XXX] MB Temperature [XXX] MB Temperature [XXX] MB Temperature [XXX] MB Temperature [XXX] Displays the detected CPU and system threshold temperatures when the Smart Fan Control feature is enabled. VCORE1 Voltage, VCORE2 Voltage, 3.3V Voltage, 5V VCORE1 Voltage, VCORE2 Voltage, 3.3V Voltage, 5V VCORE1 Voltage, VCORE2 Voltage, 3.3V Voltage, 5V VCORE1 Voltage, VCORE2 Voltage, 3.3V Voltage, 5V VCORE1 Voltage, VCORE2 Voltage, 3.3V Voltage, 5V Voltage, 5VSB Voltage, VBAT Voltage, 12V Voltage Voltage, 5VSB Voltage, VBAT Voltage, 12V Voltage Voltage, 5VSB Voltage, VBAT Voltage, 12V Voltage Voltage, 5VSB Voltage, VBAT Voltage, 12V Voltage Voltage, 5VSB Voltage, VBAT Voltage, 12V Voltage The onboard hardware monitor automatically detects the voltage outputs through the onboard voltage regulators.
5-34 5-34 5-34 5-34 5-34 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup 5.6 Boot menu The Boot menu items allow you to change the system boot options. Select an item then press <Enter> to display the sub-menu. 5.6.1 5.6.1 5.6.1 5.6.1 5.6.1 Boot Device Priority Boot Device Priority Boot Device Priority Boot Device Priority Boot Device Priority 1st Boot Device 1st Boot Device 1st Boot Device 1st Boot Device 1st Boot Device [ATAPI CD-ROM] [ATAPI CD-ROM] [ATAPI CD-ROM] [ATAPI CD-ROM] [ATAPI CD-ROM] 2nd Boot Device 2nd Boot Device 2nd Boot Device 2nd Boot Device 2nd Boot Device [1st FLOPPY DRIVE] [1st FLOPPY DRIVE] [1st FLOPPY DRIVE] [1st FLOPPY DRIVE] [1st FLOPPY DRIVE] 3rd Boot Device 3rd Boot Device 3rd Boot Device 3rd Boot Device 3rd Boot Device [Hard Drive] [Hard Drive] [Hard Drive] [Hard Drive] [Hard Drive] 4th Boot Device 4th Boot Device 4th Boot Device 4th Boot Device 4th Boot Device [Network: MBA v7.7.5] [Network: MBA v7.7.5] [Network: MBA v7.7.5] [Network: MBA v7.7.5] [Network: MBA v7.7.5] 5th Boot Device 5th Boot Device 5th Boot Device 5th Boot Device 5th Boot Device [Network: MBA v7.7.5] [Network: MBA v7.7.5] [Network: MBA v7.7.5] [Network: MBA v7.7.5] [Network: MBA v7.7.5] These items specify the boot device priority sequence from the available devices. Configuration options: [1st FLOPPY DRIVE] [ATAPI CD-ROM] [Hard Drive] [Network: MBA v7.7.5 Slot 0400] [Network: MBA v7.7.5 Slot 0300] [Disabled] Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Main Advanced Server Boot Exit Specifies the Boot Device Priority sequence. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Boot Specifies the boot sequence from the available devices. A device enclosed in parenthesis has been disabled in the corresponding menu. Boot Device Priority 1st Boot Device [ATAPI CD-ROM] 2nd Boot Device [1st FLOPPY DRIVE] 3rd Boot Device [Hard Drive] 4th Boot Device [Network: MBA v7.7.5] 5th Boot Device [Network: MBA v7.7.5] Boot Settings Boot Priority Boot Settings Configuration Security
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-35 5-35 5-35 5-35 5-35 5.6.2 5.6.2 5.6.2 5.6.2 5.6.2 Boot Settings Configuration Boot Settings Configuration Boot Settings Configuration Boot Settings Configuration Boot Settings Configuration Quick Boot [Enabled] Quick Boot [Enabled] Quick Boot [Enabled] Quick Boot [Enabled] Quick Boot [Enabled] Enabling this item allows the BIOS to skip some power on self tests (POST) while booting to decrease the time needed to boot the system. When set to [Disabled], BIOS performs all the POST items. Configuration options: [Disabled] [Enabled] Full Screen Logo [Enabled] Full Screen Logo [Enabled] Full Screen Logo [Enabled] Full Screen Logo [Enabled] Full Screen Logo [Enabled] Allows you to enable or disable the full screen logo display feature. Configuration options: [Disabled] [Enabled] Set this item to [Enabled] to use the ASUS MyLogo2™ feature. Bootup Num-Lock [On] Bootup Num-Lock [On] Bootup Num-Lock [On] Bootup Num-Lock [On] Bootup Num-Lock [On] Allows you to select the power-on state for the NumLock. Configuration options: [Off] [On] PS/2 Mouse Support [Auto] PS/2 Mouse Support [Auto] PS/2 Mouse Support [Auto] PS/2 Mouse Support [Auto] PS/2 Mouse Support [Auto] Allows you to enable or disable support for PS/2 mouse. Configuration options: [Disabled] [Enabled] [Auto] Wait for ‘F1’ If Error [Enabled] Wait for ‘F1’ If Error [Enabled] Wait for ‘F1’ If Error [Enabled] Wait for ‘F1’ If Error [Enabled] Wait for ‘F1’ If Error [Enabled] When set to Enabled, the system waits for the F1 key to be pressed when error occurs. Configuration options: [Disabled] [Enabled] Hit ‘DEL’ Message Display [Enabled] Hit ‘DEL’ Message Display [Enabled] Hit ‘DEL’ Message Display [Enabled] Hit ‘DEL’ Message Display [Enabled] Hit ‘DEL’ Message Display [Enabled] When set to Enabled, the system displays the message “Press DEL to run Setup” during POST. Configuration options: [Disabled] [Enabled] Interrupt 19 Capture [Enabled] Interrupt 19 Capture [Enabled] Interrupt 19 Capture [Enabled] Interrupt 19 Capture [Enabled] Interrupt 19 Capture [Enabled] When set to [Enabled], this function allows the option ROMs to trap Interrupt 19. Configuration options: [Disabled] [Enabled] Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. Specifies the boot llows BIOS to skip certain tests while booting. This will decrease the time needed to boot the system Boot Settings Configuration Quick Boot [Enabled] Full Screen Logo [Enabled] Bootup Num-Lock [On] PS/2 Mouse Support [Auto] Wait For ‘F1’ If Error [Enabled] Hit ‘DEL’ Message Display [Enabled] Interrupt 19 Capture [Enabled] BIOS SETUP UTILITY Boot
5-36 5-36 5-36 5-36 5-36 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup If you forget your BIOS password, you can clear it by erasing the CMOS Real Time Clock (RTC) RAM. See section “2.6 Jumpers” for information on how to erase the RTC RAM. 5.6.3 5.6.3 5.6.3 5.6.3 5.6.3 Security Security Security Security Security The Security menu items allow you to change the system security settings. Select an item then press <Enter> to display the configuration options. Change Supervisor Password Change Supervisor Password Change Supervisor Password Change Supervisor Password Change Supervisor Password Select this item to set or change the supervisor password. The Supervisor Password item on top of the screen shows the default Not Installed Not Installed Not Installed Not Installed Not Installed . After you set a password, this item shows Installed Installed Installed Installed Installed . To set or change a supervisor password: 1. Select the Change Supervisor Password Change Supervisor Password Change Supervisor Password Change Supervisor Password Change Supervisor Password item, then press <Enter>. 2. From the password box, type a password composed of at least six letters and/or numbers, then press <Enter>. 3. Confirm the password when prompted. The message “Password Installed” appears after you successfully set your password. To change the supervisor password, follow the same steps as in setting a user password. To clear the supervisor password: To clear the supervisor password: To clear the supervisor password: To clear the supervisor password: To clear the supervisor password: S elect the Change Supervisor Password Change Supervisor Password Change Supervisor Password Change Supervisor Password Change Supervisor Password then press <Enter>. The message “Password Uninstalled” appears. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. <Enter> to change password. <Enter> again to disable password. Security Settings Supervisor Password : Not Installed User Password : Not Installed Change Supervisor Password Change User Password BIOS SETUP UTILITY Boot
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-37 5-37 5-37 5-37 5-37 After you have set a supervisor password, the other items appear to allow you to change other security settings. User Access Level [Full Access] User Access Level [Full Access] User Access Level [Full Access] User Access Level [Full Access] User Access Level [Full Access] This item allows you to select the access restriction to the Setup items. Configuration options: [No Access] [View Only] [Limited] [Full Access] No Access No Access No Access No Access No Access prevents user access to the Setup utility. View Only View Only View Only View Only View Only allows access but does not allow change to any field. Limited Limited Limited Limited Limited allows changes only to selected fields, such as Date and Time. Full Access Full Access Full Access Full Access Full Access allows viewing and changing all the fields in the Setup utility. Change User Password Change User Password Change User Password Change User Password Change User Password Select this item to set or change the user password. The User Password User Password User Password User Password User Password item on top of the screen shows the default Not Installed Not Installed Not Installed Not Installed Not Installed . After you set a password, this item shows Installed Installed Installed Installed Installed . To set a user password: 1. Select the Change User Password item and press <Enter>. 2. On the password box that appears, type a password composed of at least six letters and/or numbers, then press <Enter>. 3. Confirm the password when prompted. The message “Password Installed” appears after you set your password successfully. To change the user password, follow the same steps as in setting a user password. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. <Enter> to change password. <Enter> again to disable password. Security Settings Supervisor Password : Installed User Password : Not Installed Change Supervisor Password User Access Level [Full Access] Change User Password Clear User Password Password Check [Setup] BIOS SETUP UTILITY Boot
5-38 5-38 5-38 5-38 5-38 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Clear User Password Clear User Password Clear User Password Clear User Password Clear User Password Select this item to clear the user password. Password Check [Setup] Password Check [Setup] Password Check [Setup] Password Check [Setup] Password Check [Setup] When set to [Setup], BIOS checks for user password when accessing the Setup utility. When set to [Always], BIOS checks for user password both when accessing Setup and booting the system. Configuration options: [Setup] [Always]
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 5-39 5-39 5-39 5-39 5-39 Exit & Save Changes Exit & Save Changes Exit & Save Changes Exit & Save Changes Exit & Save Changes Select this option then press <Enter>, or simply press <F10>, to save your changes to CMOS before exiting the Setup utility. When a confirmation window appears, select [OK] then press <Enter> to save your changes and exit Setup. If you wish to cancel the command, select [Cancel] then press <Enter> to return to the Exit menu. Exit & Discard Changes Exit & Discard Changes Exit & Discard Changes Exit & Discard Changes Exit & Discard Changes Select this option then press <Enter> to exit the Setup utility without saving your changes. When a confirmation window appears, select [OK] then press <Enter> to discard your changes and exit Setup. If you wish to cancel the command, select [Cancel] then press <Enter> to return to the Exit menu. Discard Changes Discard Changes Discard Changes Discard Changes Discard Changes Select this option then press <Enter> to discard the changes that you made, and restore the previously saved settings. When a confirmation window appears, select [OK] then press <Enter> to discard the changes, and load the previously saved settings. If you wish to cancel the command, select [Cancel] then press <Enter> to return to the Exit menu. If you made changes to any of the settings in the menus, pressing <Esc> does not immediately exit this menu. A confirmation window appears and prompts you to either save your changes or cancel the command. Select one of the options from this menu to exit. 5.7 Exit menu The Exit menu items allow you to load the optimal or failsafe default values for the BIOS items, and save or discard your changes to the BIOS items. Select Screen Select Item - Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc. BIOS SETUP UTILITY Main Advanced Security Boot Exit Exit system setup after saving the changes. F10 key can be used for this operation. Exit Options Exit & Save Changes Exit & Discard Changes Discard Changes Load Setup Defaults
5-40 5-40 5-40 5-40 5-40 Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Chapter 4: BIOS setup Load Setup Defaults Load Setup Defaults Load Setup Defaults Load Setup Defaults Load Setup Defaults Select this option then press <Enter> to load the optimized settings for each of the Setup menu items. When a confirmation window appears, select [OK] then press <Enter> to load the default settings. If you wish to cancel the command, select [Cancel] then press <Enter> to return to the Exit menu.
3-1 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 This chapter provides information on how toconfigure your hard disk drives as RAID sets. Chapter 6 RAID Configuration
6-2 6-2 6-2 6-2 6-2 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 6.1 Setting up RAID The motherboard comes with the following RAID solutions: P5MT model P5MT model P5MT model P5MT model P5MT model • LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID technology embedded in the Intel ® ICH7R Southbridge supports up to two SATA hard disk drives and RAID 0, RAID 1, and RAID 10 configurations. P5MT/SCSI model P5MT/SCSI model P5MT/SCSI model P5MT/SCSI model P5MT/SCSI model • LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID • LSI53C1020A PCI-X SCSI controller LSI53C1020A PCI-X SCSI controller LSI53C1020A PCI-X SCSI controller LSI53C1020A PCI-X SCSI controller LSI53C1020A PCI-X SCSI controller supports SCSI hard disk drives and RAID 0, RAID 1, RAID 1-E configurations. 6.1.1 6.1.1 6.1.1 6.1.1 6.1.1 RAID definitions RAID definitions RAID definitions RAID definitions RAID definitions RAID 0 RAID 0 RAID 0 RAID 0 RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a sustained data transfer rate, double that of a single disk alone, thus improving data access and storage. Use of two new identical hard disk drives is required for this setup. RAID 1 RAID 1 RAID 1 RAID 1 RAID 1 (Data mirroring) copies and maintains an identical image of data from one drive to a second drive. If one drive fails, the disk array management software directs all applications to the surviving drive as it contains a complete copy of the data in the other drive. This RAID configuration provides data protection and increases fault tolerance to the entire system. Use two new drives or use an existing drive and a new drive for this setup. The new drive must be of the same size or larger than the existing drive. RAID 1 RAID 1 RAID 1 RAID 1 RAID 1 -E -E -E -E -E (Enhanced RAID 1) has a striped layout with each stripe unit having a secondary (or alternate) copy stored on a different disk. You can use three or more hard disk drives for this configuration. RAID 0 1 RAID 0 1 RAID 0 1 RAID 0 1 RAID 0 1 i s data striping and data mirroring combined without parity (redundancy data) having to be calculated and written. With the RAID 0 1 configuration you get all the benefits of both RAID 0 and RAID 1 configurations. Use four new hard disk drives or use an existing drive and three new drives for this setup. JBOD JBOD JBOD JBOD JBOD (Spanning) stands for Just a Bunch of Disks Just a Bunch of Disks Just a Bunch of Disks Just a Bunch of Disks Just a Bunch of Disks and refers to hard disk drives that are not yet configured as a RAID set. This configuration stores the same data redundantly on multiple disks that appear as a single disk on the operating system. Spanning does not deliver any advantage over using separate disks independently and does not provide fault tolerance or other RAID performance benefits. If you want to boot the system from a hard disk drive included in a created RAID set, copy first the RAID driver from the support CD to a floppy disk before you install an operating system to the selected hard disk drive. Refer to Chapter 6 for details.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-3 6-3 6-3 6-3 6-3 6.1.2 6.1.2 6.1.2 6.1.2 6.1.2 Installing hard disk drives Installing hard disk drives Installing hard disk drives Installing hard disk drives Installing hard disk drives The motherboard supports Serial ATA (both models) and SCSI hard disk drives (P5MT/SCSI model only) for RAID set configuration. For optimal performance, install identical drives of the same model and capacity when creating a disk array. To install the SATA hard disks for RAID configuration: 1. Install the SATA hard disks into the drive bays following the instructions in the system user guide. 2. Connect a SATA signal cable to the signal connector at the back of each drive and to the SATA connector on the motherboard. 3. Connect a SATA power cable to the power connector on each drive. To install the SCSI hard disks for RAID configuration: 1. Install the SCSI hard disks into the drive bays following the instructions in the system user guide. 2. Connect the SCSI interface cable connectors at the back of the SCSI drives. 3. Connect the other end of the SCSI interface cable to the SCSI connector on the motherboard. 6.1.3 6.1.3 6.1.3 6.1.3 6.1.3 Setting the RAID item in BIOS Setting the RAID item in BIOS Setting the RAID item in BIOS Setting the RAID item in BIOS Setting the RAID item in BIOS You must set the RAID item in the BIOS Setup before you can create a RAID set from SATA hard disk drives attached to the SATA connectors supported by the Intel ® ICH7R Southbridge chip. To do this: 1. Enter the BIOS Setup during POST. 2. Go to the Main Menu Main Menu Main Menu Main Menu Main Menu , select IDE Configuration IDE Configuration IDE Configuration IDE Configuration IDE Configuration , then press <Enter>. 3. Set the ATA/IDE Configuration ATA/IDE Configuration ATA/IDE Configuration ATA/IDE Configuration ATA/IDE Configuration item to [Enhanced Mode], then press <Enter>. 4. Set the Configure SATA As Configure SATA As Configure SATA As Configure SATA As Configure SATA As item to [RAID]. 5. Save your changes, then exit the BIOS Setup. Refer to Chapter 5 for details on entering and navigating through the BIOS Setup.
6-4 6-4 6-4 6-4 6-4 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 6.1.4 6.1.4 6.1.4 6.1.4 6.1.4 RAID configuration utilities RAID configuration utilities RAID configuration utilities RAID configuration utilities RAID configuration utilities Depending on the RAID connectors that you use, you can create a RAID set using the utilities embedded in each RAID controller. For example, use the LSI Logic Embedded SATA RAID Setup Utility LSI Logic Embedded SATA RAID Setup Utility LSI Logic Embedded SATA RAID Setup Utility LSI Logic Embedded SATA RAID Setup Utility LSI Logic Embedded SATA RAID Setup Utility i f you installed SATA hard disk drives on the SATA connectors supported by the Intel ® ICH7R Southbridge and/or the LSI Logic Configuration Utility LSI Logic Configuration Utility LSI Logic Configuration Utility LSI Logic Configuration Utility LSI Logic Configuration Utility i f y o u installed SCSI hard disk drives to the SCSI connector(s) supported by the LSI53C1020A PCI-X SCSI controller (P5MT/SCSI model only). Refer to the succeeding sections for details on how to use each RAID configuration utility.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-5 6-5 6-5 6-5 6-5 3. The utility main window appears. Use the arrow keys to select an option from the Management Menu Management Menu Management Menu Management Menu Management Menu , then press <Enter>. Refer to the Management Menu descriptions on the next page. At the bottom of the screen is the legend box. The keys on the legend box allow you to navigate through the setup menu options or execute commands. The keys on the legend box vary according to the menu level. 6.2 LSI Logic Embedded SATA RAID Setup Utility The LSI Logic Embedded SATA RAID Setup Utility allows you to create RAID 0, RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard ICH7 R Southbridge chip. To enter the LSI Logic Embedded SATA RAID Setup Utility: 1. Turn on the system after installing all the SATA hard disk drives. 2. During POST, the LSI Logic Embedded SATA RAID Setup Utility automatically detects the installed SATA hard disk drives and displays any existing RAID set(s). Press <Ctrl> <M> to enter the utility. The LSI Logic Embedded SATA RAID auto configures to RAID 1 when the SATA to RAID Mode is enabled.
6-6 6-6 6-6 6-6 6-6 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Menu Menu Menu Menu Menu Description Description Description Description Description Configure Allows you to create RAID 0 or RAID 1 set using the Easy Configuration or the New Configuration command. This menu also allows you to view, add, or clear RAID configurations or select the boot drive Initialize Allows you to initialize the logical drives of a created RAID set Objects Allows you to initialize logical drives or change the logical drive parameters Rebuild Allows you to rebuild failed drives Check Consistency Allows you to check the data consistency of the logical drives of a created RAID set 6.2.1 6.2.1 6.2.1 6.2.1 6.2.1 Creating a RAID 0 or RAID 1 set Creating a RAID 0 or RAID 1 set Creating a RAID 0 or RAID 1 set Creating a RAID 0 or RAID 1 set Creating a RAID 0 or RAID 1 set The LSI Logic Embedded SATA RAID Setup Utility allows you to create a RAID 0 or RAID 1 set using two types of configurations: Easy Easy Easy Easy Easy and New New New New New . In Easy Configuration Easy Configuration Easy Configuration Easy Configuration Easy Configuration , the logical drive parameters are set automatically including the size and stripe size (RAID 1 only). In New Configuration New Configuration New Configuration New Configuration New Configuration , you manually set the logical drive parameters and assign the set size and stripe size (RAID 1 only). Using Easy Configuration Using Easy Configuration Using Easy Configuration Using Easy Configuration Using Easy Configuration To create a RAID set using the Easy Configuration Easy Configuration Easy Configuration Easy Configuration Easy Configuration option: 1. From the utility main menu, highlight Configure Configure Configure Configure Configure , then press <Enter>. 2. Use the arrow keys to select Easy Configuration Easy Configuration Easy Configuration Easy Configuration Easy Configuration , then press <Enter>.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-7 6-7 6-7 6-7 6-7 4. Select all the drives required for the RAID set, then press <Enter>. The configurable array appears on screen. 3. The ARRAY SELECTION MENU ARRAY SELECTION MENU ARRAY SELECTION MENU ARRAY SELECTION MENU ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Select the drives you want to include in the RAID set, then press <SpaceBar>. When selected, t he drive indicator changes from READY READY READY READY READY t o ONLIN A[X]-[Y] ONLIN A[X]-[Y] ONLIN A[X]-[Y] ONLIN A[X]-[Y] ONLIN A[X]-[Y] , where X is the array number, and Y is the drive number. The information of the selected hard disk drive displays at the bottom of the screen.
6-8 6-8 6-8 6-8 6-8 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 5. Press <F10>, select the configurable array, then press <SpaceBar>. The logical drive information appears including a Logical Drive menu that allows you to change the logical drive parameters.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-9 6-9 6-9 6-9 6-9 6. Select RAID RAID RAID RAID RAID from the Logical Drive Logical Drive Logical Drive Logical Drive Logical Drive menu, then press <Enter>. 7. Select the RAID level from the menu, then press <Enter>. You need at least two identical hard disk drives when creating a RAID 1 set. 8. When creating a RAID 1 set, select Stripe Size Stripe Size Stripe Size Stripe Size Stripe Size from the Logical Logical Logical Logical Logical Drive Drive Drive Drive Drive menu, then press <Enter>. When creating a RAID 0 set, proceed to step 10. 9. Key-in the stripe size, then press <Enter>. For server systems, we recommend that you use a lower array block size. For multimedia computer systems used mainly for audio and video editing, we recommend a higher array block size for optimum performance.
6-10 6-10 6-10 6-10 6-10 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 10. When finished setting the selected logical drive configuration, select Accept Accept Accept Accept Accept from the menu, then press <Enter>. 11. When finished setting the selected logical drive configuration, select Accept Accept Accept Accept Accept from the menu, then press <Enter>. 12. Follow steps 5 to 10 to configure additional logical drives. 13. When prompted, save the configuration, then press <Esc> to return to the Management Menu.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-11 6-11 6-11 6-11 6-11 6.2.2 6.2.2 6.2.2 6.2.2 6.2.2 Creating a RAID 10 set Creating a RAID 10 set Creating a RAID 10 set Creating a RAID 10 set Creating a RAID 10 set You can create a RAID 10 set using four identical hard disk drives. To create a RAID 10 set using the Easy Configuration Easy Configuration Easy Configuration Easy Configuration Easy Configuration option: 1. From the utility main menu, highlight Configure Configure Configure Configure Configure , then press <Enter>. 2. Use the arrow keys to select Easy Configuration Easy Configuration Easy Configuration Easy Configuration Easy Configuration , then press <Enter>. 3. The ARRAY SELECTION MENU ARRAY SELECTION MENU ARRAY SELECTION MENU ARRAY SELECTION MENU ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Select the drive(s) you want to include in the RAID set, then press <SpaceBar>. When selected, t he drive indicator changes from READY READY READY READY READY t o ONLIN A[X]-[Y] ONLIN A[X]-[Y] ONLIN A[X]-[Y] ONLIN A[X]-[Y] ONLIN A[X]-[Y] , where X is the array number, and Y is the drive number. The information of the selected hard disk drive displays at the bottom of the screen.
6-12 6-12 6-12 6-12 6-12 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 4. Select all the drives required for the RAID 10 set, then press <Enter>. The configurable array appears on screen. 5. Press <F10>, select the configurable array, then press <SpaceBar>. The logical drive information appears including a Logical Drive menu that allows you to change the logical drive parameters.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-13 6-13 6-13 6-13 6-13 6. Select RAID RAID RAID RAID RAID from the Logical Drive Logical Drive Logical Drive Logical Drive Logical Drive menu, then press <Enter>. 7. Select RAID 10 from the menu, then press <Enter>. You need at least four identical hard disk drives when creating a RAID 10 set. 8. Select Stripe Size Stripe Size Stripe Size Stripe Size Stripe Size from the Logical Drive Logical Drive Logical Drive Logical Drive Logical Drive menu, then press <Enter>. 9. Key-in the stripe size, then press <Enter>. For server systems, we recommend that you use a lower array block size. For multimedia computer systems used mainly for audio and video editing, we recommend a higher array block size for optimum performance.
6-14 6-14 6-14 6-14 6-14 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 10. When finished setting the selected logical drive configuration, select Accept Accept Accept Accept Accept from the menu, then press <Enter>. 11. When prompted, save the configuration, then press <Esc> to return to the Management Menu.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-15 6-15 6-15 6-15 6-15 6.2.3 6.2.3 6.2.3 6.2.3 6.2.3 Adding or viewing a RAID configuration Adding or viewing a RAID configuration Adding or viewing a RAID configuration Adding or viewing a RAID configuration Adding or viewing a RAID configuration You can add a new RAID configuration or view an existing configuration using the View/Add Configuration View/Add Configuration View/Add Configuration View/Add Configuration View/Add Configuration command. Adding a new RAID configuration Adding a new RAID configuration Adding a new RAID configuration Adding a new RAID configuration Adding a new RAID configuration To add a new RAID configuration: 1. From the Management Menu, highlight Configure Configure Configure Configure Configure , then press <Enter>. 2. Use the arrow keys to select View/Add Configuration View/Add Configuration View/Add Configuration View/Add Configuration View/Add Configuration , then press <Enter>. 3. The ARRAY SELECTION MENU ARRAY SELECTION MENU ARRAY SELECTION MENU ARRAY SELECTION MENU ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Select the drive(s) you want to include in the RAID set, then press <SpaceBar>. When selected, t he drive indicator changes from READY READY READY READY READY t o ONLIN A[X]-[Y] ONLIN A[X]-[Y] ONLIN A[X]-[Y] ONLIN A[X]-[Y] ONLIN A[X]-[Y] , where X is the array number, and Y is the drive number. The information of the selected hard disk drive displays at the bottom of the screen.
6-16 6-16 6-16 6-16 6-16 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 4. Select all the drives required for the RAID set, then press <Enter>. The configurable array appears on screen. 5. Press <F10>, select the configurable array, then press <SpaceBar>. The logical drive information appears including a Logical Drive menu that allows you to change the logical drive parameters.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-17 6-17 6-17 6-17 6-17 6. Follow steps 6 to 7 of the Creating a RAID set: Using Easy Creating a RAID set: Using Easy Creating a RAID set: Using Easy Creating a RAID set: Using Easy Creating a RAID set: Using Easy Configuration Configuration Configuration Configuration Configuration section. 7. Select Size Size Size Size Size from the Logical Drive Logical Drive Logical Drive Logical Drive Logical Drive menu, then press <Enter>. 8. Key-in the desired logical drive size, then press <Enter>. 9. Follow steps 8 to 13 of the Creating a RAID set: Using Easy Creating a RAID set: Using Easy Creating a RAID set: Using Easy Creating a RAID set: Using Easy Creating a RAID set: Using Easy Configuration Configuration Configuration Configuration Configuration section to add the new RAID configuration.
6-18 6-18 6-18 6-18 6-18 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 6.2.4 6.2.4 6.2.4 6.2.4 6.2.4 Initializing the logical drives Initializing the logical drives Initializing the logical drives Initializing the logical drives Initializing the logical drives After creating the RAID set(s), you must initialize the logical drives. You may initialize the logical drives of a RAID set(s) using the Initialize Initialize Initialize Initialize Initialize o r Objects Objects Objects Objects Objects command on the Management Menu. Using the Initialize command Using the Initialize command Using the Initialize command Using the Initialize command Using the Initialize command To initialize the logical drive using the Initialize Initialize Initialize Initialize Initialize command: 1. From the Management Menu, highlight Initialize Initialize Initialize Initialize Initialize , then press <Enter>. 2. The screen displays the available RAID set(s) and prompts you to select the logical drive to initialize. Use the arrow keys to select the logical drive from the Logical Drive Logical Drive Logical Drive Logical Drive Logical Drive selection, then press <Enter>.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-19 6-19 6-19 6-19 6-19 3. When prompted, press the <SpaceBar> to select Yes Yes Yes Yes Yes from the Initialize? Initialize? Initialize? Initialize? Initialize? dialog box, then press <Enter>. You may also press <F10> to initialize the drive without confirmation. Initializing a logical drive(s) erases all data on the drive. 4. A progress bar appears on screen. If desired, press <Esc> to abort initialization.
6-20 6-20 6-20 6-20 6-20 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 5. When initialization is completed, press <Esc>. Using the Objects command Using the Objects command Using the Objects command Using the Objects command Using the Objects command To initialize the logical drives using the Objects Objects Objects Objects Objects command: 1. From the Management Menu, highlight Objects Objects Objects Objects Objects , then press <Enter>.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-21 6-21 6-21 6-21 6-21 2. Select Logical Drive Logical Drive Logical Drive Logical Drive Logical Drive from the Objects Objects Objects Objects Objects sub-menu, then press <Enter>. 3. Select the logical drive to initialize from the Logical Drives Logical Drives Logical Drives Logical Drives Logical Drives sub-menu, then press <Enter>. 4. Select Initialize from the pop-up menu, then press <Enter> to start initialization.
6-22 6-22 6-22 6-22 6-22 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 5. When prompted, press the <SpaceBar> to select Yes Yes Yes Yes Yes from the Initialize? Initialize? Initialize? Initialize? Initialize? dialog box, then press <Enter>. You may also press <F10> to initialize the drive without confirmation. 6. A progress bar appears on screen. If desired, press <Esc> to abort initialization. 7. When initialization is completed, press <Esc>.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-23 6-23 6-23 6-23 6-23 6.2.5 6.2.5 6.2.5 6.2.5 6.2.5 Rebuilding failed drives Rebuilding failed drives Rebuilding failed drives Rebuilding failed drives Rebuilding failed drives You can manually rebuild failed hard disk drives using the Rebuild Rebuild Rebuild Rebuild Rebuild command in the Management Menu. To rebuild a failed hard disk drive: 1. From the Management Menu, highlight Rebuild Rebuild Rebuild Rebuild Rebuild , then press <Enter>. 2. The PHYSICAL DRIVES SELECTION MENU PHYSICAL DRIVES SELECTION MENU PHYSICAL DRIVES SELECTION MENU PHYSICAL DRIVES SELECTION MENU PHYSICAL DRIVES SELECTION MENU displays the available drives connected to the SATA ports. S elect the drive you want to rebuild, then p ress <SpaceBar>.
6-24 6-24 6-24 6-24 6-24 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 3. After selecting the drive to rebuild, press <F10>. The indicator for the selected drive now shows RBLD RBLD RBLD RBLD RBLD . 4. When prompted, press <Y> to to rebuild the drive. 5. When rebuild is complete, press any key to continue.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-25 6-25 6-25 6-25 6-25 6.2.6 6.2.6 6.2.6 6.2.6 6.2.6 Checking the drives for data consistency Checking the drives for data consistency Checking the drives for data consistency Checking the drives for data consistency Checking the drives for data consistency You can check and verify the accuracy of data redundancy in the selected logical drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects Objects Objects Objects Objects > Adapter Adapter Adapter Adapter Adapter menu. The Check Consistency command is available only for logical drives included in a RAID 1 set. Using the Check Consistency Using the Check Consistency Using the Check Consistency Using the Check Consistency Using the Check Consistency To check data consistency using the Check Consistency Check Consistency Check Consistency Check Consistency Check Consistency command: 1. From the Management Menu, select Check Consistency Check Consistency Check Consistency Check Consistency Check Consistency , then press <Enter>. 2. The screen displays the available RAID set(s) and prompts you to select the logical drive to check. Use the arrow keys to select the logical drive from the Logical Drive Logical Drive Logical Drive Logical Drive Logical Drive selection, then press <Enter>.
6-26 6-26 6-26 6-26 6-26 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 3. When prompted, press the <SpaceBar> to select Yes Yes Yes Yes Yes from the Consistency Check Consistency Check Consistency Check Consistency Check Consistency Check dialog box, then press <Enter>. You may also press <F10> to check the drive consistency. A progress bar appears on screen. 4. While checking the disk consistency, press <Esc> to display the following options. • Stop - Stops the consistency check. The utility stores the percentage of disk checked, When you restart checking, it continues from the last percentage completed rather than from zero percent. • Continue - Continues the consistency check. • Abort - Aborts the consistency check. When you restart checking, it continues from zero percent. 5. When checking is complete, press any key to continue.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-27 6-27 6-27 6-27 6-27 Using the Objects command Using the Objects command Using the Objects command Using the Objects command Using the Objects command To check data consistency using the Objects Objects Objects Objects Objects command: 1. From the Management Menu, select Objects Objects Objects Objects Objects , then select Logical Logical Logical Logical Logical Drive Drive Drive Drive Drive from the menu. 2. Use the arrow keys to select the logical drive you want to check, then press < Enter>. 3. Select Check Consistency Check Consistency Check Consistency Check Consistency Check Consistency from the pop-up menu, then press <Enter>. 4. When prompted, press <Y> to to check the drive. 5. When checking is complete, press any key to continue.
6-28 6-28 6-28 6-28 6-28 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 6.2.7 6.2.7 6.2.7 6.2.7 6.2.7 Deleting a RAID configuration Deleting a RAID configuration Deleting a RAID configuration Deleting a RAID configuration Deleting a RAID configuration To delete a RAID configuration: 1. From the Management Menu, select Configure Configure Configure Configure Configure > Clear Clear Clear Clear Clear Configuration Configuration Configuration Configuration Configuration , then press <Enter>. 2. When prompted, press the <SpaceBar> to select Yes Yes Yes Yes Y e s from the Clear Clear Clear Clear Clear Configuration? Configuration? Configuration? Configuration? Configuration? dialog box, then press <Enter>. The utility clears the current array. 3. Press any key to continue.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-29 6-29 6-29 6-29 6-29 6.2.8 6.2.8 6.2.8 6.2.8 6.2.8 Selecting the boot drive from a RAID set Selecting the boot drive from a RAID set Selecting the boot drive from a RAID set Selecting the boot drive from a RAID set Selecting the boot drive from a RAID set You must have created a new RAID configuration before you can select the boot drive from a RAID set. Refer to the Creating a RAID set: Using Creating a RAID set: Using Creating a RAID set: Using Creating a RAID set: Using Creating a RAID set: Using New Configuration New Configuration New Configuration New Configuration New Configuration section for details. To select the boot drive from a RAID set: 1. From the Management Menu, select Configure Configure Configure Configure Configure > Select Boot Select Boot Select Boot Select Boot Select Boot Drive Drive Drive Drive Drive , then press <Enter>. 2. When prompted, press the <SpaceBar> to select the bootable logical drive from the list, then press <Enter>. 3. The logical drive is selected as boot drive. Press any key to continue.
6-30 6-30 6-30 6-30 6-30 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 6.2.9 6.2.9 6.2.9 6.2.9 6.2.9 Enabling the WriteCache Enabling the WriteCache Enabling the WriteCache Enabling the WriteCache Enabling the WriteCache You may enable the RAID controller’s WriteCache WriteCache WriteCache WriteCache WriteCache option to improve the data transmission performance. When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives. To enable WriteCache: 1. From the Management Menu, select Objects Objects Objects Objects Objects > Adapter Adapter Adapter Adapter Adapter , then press <Enter> to display the adapter properties. 2. Select WriteCache WriteCache WriteCache WriteCache WriteCache , then press <Enter> to turn the option On On On On On (enabled). 6.3 Global Array Manager You may also create a RAID set(s) in Windows ® operating environment using the Global Array Manager (GAM) application. The GAM application is available from the motherboard support CD. Refer to the GAM user guide in the motherboard support CD for details. 3. When finished, press any key to continue.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-31 6-31 6-31 6-31 6-31 6.4 LSI Logic Configuration Utility (for PS4 model only) The LSI Logic Configuration Utility allows you to create RAID 0, RAID 1, and RAID-1E from SCSI hard disk drives connected to the SCSI connectors supported by the LSI53C1020A PCI-X SCSI controller. To enter the LSI Logic Configuration Utility: 1. Turn on the system after installing all the SATA hard disk drives. 2. During POST, Press <Ctrl> <C> to enter the LSI Logic Configuration Utility. The LSI Logic Configuration Utility main menu appears. The LSI Logic Configuration Utility has two tabbed menus that you can select by pressing <F2>. Refer to the next section for details.
6-32 6-32 6-32 6-32 6-32 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 6.4.1 6.4.1 6.4.1 6.4.1 6.4.1 Boot Adapter List Boot Adapter List Boot Adapter List Boot Adapter List Boot Adapter List The Boot Adapter List Boot Adapter List Boot Adapter List Boot Adapter List Boot Adapter List tab allows you to select and configure the SCSI controller, create arrays, and arrange the sequence of available boot adapters. Changing the adapter boot sequence Changing the adapter boot sequence Changing the adapter boot sequence Changing the adapter boot sequence Changing the adapter boot sequence To change the adapter boot sequence: 1. Select the adapter from the list (1020/1030), then press <Insert>. The screen displays the selected adapter’s properties. Refer to the table below for a description of the properties. 2. Move the selection to the Boot Order Boot Order Boot Order Boot Order Boot Order column, then press the < > or <-> key to adjust the adapter boot sequence. Property Property Property Property Property Description Description Description Description Description Adapter Adapter Adapter Adapter Adapter Identifies the specific family of LSI Logic Host Adapters. PCI Bus PCI Bus PCI Bus PCI Bus PCI Bus Identifies the PCI Bus number assigned by the system BIOS to an adapter (range 0x00 - 0xFF, 0 - 255 decimal). Dev/Func Dev/Func Dev/Func Dev/Func Dev/Func Identifies the PCI Device/Function assigned by the system BIOS to the selected adapter. Boot Order Boot Order Boot Order Boot Order Boot Order Identifies the relative boot order (0 to 3) of an adapter. The Fusion-MPT SCSI BIOS traverses up to four adapters in the specified order in search of bootable media. Access the “Boot Adapter List” Menu to modify this item. 3. When finished, press <Enter> to open the Adapter Properties Adapter Properties Adapter Properties Adapter Properties Adapter Properties screen; otherwise, press <Esc> to exit the utility.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-33 6-33 6-33 6-33 6-33 6.4.2 6.4.2 6.4.2 6.4.2 6.4.2 Global Properties Global Properties Global Properties Global Properties Global Properties The Global Properties Global Properties Global Properties Global Properties Global Properties tab allows you to configure the general adapter properties. To access the general properties screen, select the adapter from the list, then press <Enter>. Changing the general adapter properties Changing the general adapter properties Changing the general adapter properties Changing the general adapter properties Changing the general adapter properties To change the general adapter properties: 1. Select an item from the Global Properties screen, then press < > or <-> change the value. Pause When Boot Alert Displayed Pause When Boot Alert Displayed Pause When Boot Alert Displayed Pause When Boot Alert Displayed Pause When Boot Alert Displayed This option specifies whether to pause for user acknowledgement after displaying an alert message during boot. If you want the user to press any key after displaying the alert message, set this item to [Yes]. Set this item to [No] to continue the boot after displaying the alert message.
6-34 6-34 6-34 6-34 6-34 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Boot Information Display Mode Boot Information Display Mode Boot Information Display Mode Boot Information Display Mode Boot Information Display Mode Allows you to specify the amount of displayed information for the adapters and devices during POST. To display minimum information, set this item to [Terse]. To display detailed information, select [Verbose] Negotiate with devices Negotiate with devices Negotiate with devices Negotiate with devices Negotiate with devices Sets the default value for synchronous and wide negotiations with specified devices. Configuration options: [All] [None] [Supported]. Video Mode Video Mode Video Mode Video Mode Video Mode Specifies the default video mode for the Configuration Utility. You can set the Video Mode to [Color] or [Monochrome]. Set this item to [Monochrome] for better screen readability when using a monochrome monitor. Support Interrupt Support Interrupt Support Interrupt Support Interrupt Support Interrupt Allows you to prevent a hook on INT40, if required. Disable Integrated RAID Disable Integrated RAID Disable Integrated RAID Disable Integrated RAID Disable Integrated RAID Allows you to disable bus scan search for RAID member devices. This item also allows you to disable configuration of RAID arrays in the BIOS. <Restore Defaults> <Restore Defaults> <Restore Defaults> <Restore Defaults> <Restore Defaults> Allows you to load the default settings. Select this item, then press <Enter> to revert to the default settings.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-35 6-35 6-35 6-35 6-35 6.4.3 6.4.3 6.4.3 6.4.3 6.4.3 Adapter Properties Adapter Properties Adapter Properties Adapter Properties Adapter Properties The Adapter Properties Adapter Properties Adapter Properties Adapter Properties Adapter Properties page allows you to configure the device and RAID properties. To access the adapter properties screen, select the adapter from the Boot Adapter List, then press <Enter>. The Adapter Properties Adapter Properties Adapter Properties Adapter Properties Adapter Properties page appears. The Adapter Properties Adapter Properties Adapter Properties Adapter Properties Adapter Properties page allows you to go to the Device Device Device Device Device Properties Properties Properties Properties Properties page or the RAID Properties RAID Properties RAID Properties RAID Properties RAID Properties page. Refer to the corresponding sections for details.
6-36 6-36 6-36 6-36 6-36 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Changing the adapter properties Changing the adapter properties Changing the adapter properties Changing the adapter properties Changing the adapter properties To change the adapter properties, select an item from the Global Properties screen, then press < > or <-> change the value. Refer to the items description below. Pause When Boot Alert Displayed Pause When Boot Alert Displayed Pause When Boot Alert Displayed Pause When Boot Alert Displayed Pause When Boot Alert Displayed This option specifies whether to pause for user acknowledgement after displaying an alert message during boot. If you want the user to press any key after displaying the alert message, set this item to [Yes]. Set this item to [No] to continue the boot after displaying the alert message. <Device Properties> <Device Properties> <Device Properties> <Device Properties> <Device Properties> Allows you to view and modify the device properties. Press <Enter> to display the Device Properties Device Properties Device Properties Device Properties Device Properties page. <RAID Properties> <RAID Properties> <RAID Properties> <RAID Properties> <RAID Properties> Allows you to view, create, delete, and/or configure RAID arrays. Press <Enter> to display the RAID Properties RAID Properties RAID Properties RAID Properties RAID Properties page. <Synchronize Whole Mirror> <Synchronize Whole Mirror> <Synchronize Whole Mirror> <Synchronize Whole Mirror> <Synchronize Whole Mirror> Allows you to copy the data from the mirrored array primary copy to the secondary copy. Host SCSI ID Host SCSI ID Host SCSI ID Host SCSI ID Host SCSI ID Indicates the SCSI identifier of an adapter [0-7] or [0-15]. It is recommended to set this item to the highest priority SCSI identifier, which is 7. 8-bit SCSI devices can not see identifiers greater than 7.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-37 6-37 6-37 6-37 6-37 SCSI Bus Scan Order SCSI Bus Scan Order SCSI Bus Scan Order SCSI Bus Scan Order SCSI Bus Scan Order Indicates the order in which to scan SCSI identifiers on an adapter. Changing this item will affect drive letter assignment(s) if more than one device is attached to an adapter. Changing this item may conflict with an operating system that automatically assigns drive order. Removable Media Support Removable Media Support Removable Media Support Removable Media Support Removable Media Support Allows you to specify the removable media support option for an adapter. Select [None] to disable removable media support whether the drive is selected as first (BBS), or is first in the scan order (non- BBS). Set this item to [Boot Drive Only] to enable removable media support for a removable hard drive if it is first in the scan order. Select [With Media Installed] to enable support for removable media regardless of the drive ordering. CHS Mapping CHS Mapping CHS Mapping CHS Mapping CHS Mapping Defines how the Cylinder Head Sector values are mapped into a disk without pre-existing partition information. CHS Mapping allows either SCSI Plug and Play Mapping SCSI Plug and Play Mapping SCSI Plug and Play Mapping SCSI Plug and Play Mapping SCSI Plug and Play Mapping (default value) or Alternate CHS Alternate CHS Alternate CHS Alternate CHS Alternate CHS Mapping Mapping Mapping Mapping Mapping . SCSI Plug and Play Mapping automatically determines the most efficient and compatible mapping. Alternate CHS Mapping uses an alternate, possibly less efficient mapping that may be required if a device is moved between adapters from different vendors. These options has no effect after a disk has been partitioned using the FDISK command. To change the CHS Mapping on a partitioned disk, use FDISK command to delete all partitions, then reboot the system to clear memory. If not, the old partitioning data will be reused, thus nullifying the previous operation. Ensure that the correct disk is the target of an FDISK command.
6-38 6-38 6-38 6-38 6-38 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Spinup Delay (Secs) Spinup Delay (Secs) Spinup Delay (Secs) Spinup Delay (Secs) Spinup Delay (Secs) Determines the waiting time (in seconds) between spinups of devices attached to an adapter. Staggered spinups will balance the total electrical current load on the system during boot. The default value is 2 seconds. Configuration options: 1 ~ 10 seconds Secondary Cluster Server Secondary Cluster Server Secondary Cluster Server Secondary Cluster Server Secondary Cluster Server Specifies whether an adapter has one or more devices that are attached or are shared with another adapter(s). When you set this option to [Yes] the Fusion-MPT PCI SCSI BIOS avoids SCSI Bus resets as much as possible when two or more devices are shared with the other adapter. This option allows you to enable an adapter to join a cluster of adapters without doing any SCSI bus resets. This is a requirement for the Microsoft Cluster Server. The default value is [No]. Termination Control Termination Control Termination Control Termination Control Termination Control Indicates whether an adapter has automatic termination control, and displays the current termination control status, if any. When set to [Auto], the adapter automatically determines whether it should enable or disable its termination. Set to [Off] allows the devices at the ends of the SCSI bus to terminate the bus. When the option [Auto] is grayed out, termination is automatic and is non-configurable. Restore Defaults Restore Defaults Restore Defaults Restore Defaults Restore Defaults Select this option, then press <Enter> to load the default settings.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-39 6-39 6-39 6-39 6-39 Device Properties Device Properties Device Properties Device Properties Device Properties The Device Properties Device Properties Device Properties Device Properties Device Properties page allows you update and view individual devices connected to the adapter.To open the device properties screen, select the <Device Properties> <Device Properties> <Device Properties> <Device Properties> <Device Properties> from the Adapter Properties window, then press <Enter>. The Device Properties screen appears. SCSI ID SCSI ID SCSI ID SCSI ID SCSI ID Displays the SCSI identifier of each device connected to the adapter. Device Identifier Device Identifier Device Identifier Device Identifier Device Identifier Displays the ASCII device identifier string extracted from the device’s Inquiry Data. Sync Rate Sync Rate Sync Rate Sync Rate Sync Rate Displays the maximum synchronous data transfer rate, in Mega Transfers per second. Data Width Data Width Data Width Data Width Data Width Displays the maximum data width in bits. Scan ID Scan ID Scan ID Scan ID Scan ID Specifies whether to scan for the SCSI device during boot. Set this item to [No] when: • You want the system to ignore a device and decrease boot time. • You do not want the device to be available to the system. • Disable scan on a bus with only a few attached devices.
6-40 6-40 6-40 6-40 6-40 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Scan LUNs > 0 Scan LUNs > 0 Scan LUNs > 0 Scan LUNs > 0 Scan LUNs > 0 Allows you to scan for LUNs greater than zero for a device. LUN zero is always queried. Use this option if a multi-LUN device responds to unoccupied LUNs or if it is desired to reduce the visibility of a multi- LUN device to LUN zero only. Set this option to [No] if you have problems with a device that responds to all LUNs whether they are occupied or not. Also, set this item to [No] if a SCSI device with multiple LUNs exists on your system but you do not want all of those LUNs to be available. This will limit the scan to LUN 0 only. Disconnect Disconnect Disconnect Disconnect Disconnect Displays whether to allow a device to disconnect during SCSI operations. Some (mostly newer) devices may run faster when you enable this option, while some (mostly older) devices may run faster when you disable this option. SCSI Timeout SCSI Timeout SCSI Timeout SCSI Timeout SCSI Timeout This field indicates the maximum amount of time [0 to 9999 seconds] to wait for a SCSI operation to complete. While timeouts provide a safeguard that allows the system to recover should an operation fail, it is recommended that you use a value greater than zero. A value of zero allows unlimited time for an operation to complete and could result in the system hanging should an operation fail. Press <Enter>, type in a value, and then press <Enter> again to set a new timeout value. Queue Tags Queue Tags Queue Tags Queue Tags Queue Tags Allows you to use queue tags for a device. Currently, the BIOS does not use queue tags. This item specifies queue tag control to higher level device drivers.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-41 6-41 6-41 6-41 6-41 RAID Properties RAID Properties RAID Properties RAID Properties RAID Properties The RAID Properties RAID Properties RAID Properties RAID Properties RAID Properties page allows you update and view individual devices connected to the adapter.To open the device properties screen, select the <Device Properties> <Device Properties> <Device Properties> <Device Properties> <Device Properties> from the Adapter Properties window, then press <Enter>. The Device Properties screen appears. SCSI ID SCSI ID SCSI ID SCSI ID SCSI ID Displays the SCSI ID that the operating system or application addresses the array. Size(MB) Size(MB) Size(MB) Size(MB) Size(MB) Displays the size of the array. Array Disk? Array Disk? Array Disk? Array Disk? Array Disk? Select [Yes] to include the drive in a disk array. You can select a minimum of two drives and a maximum of six drives. Select a maximum of five drives when you select a hot spare. Hot Spare Hot Spare Hot Spare Hot Spare Hot Spare Sets the drive as a hot spare. You can select a single hot spare. The Hot Spare disk provides additional protection by automatically replacing an array member when it fails. Status Status Status Status Status Displays the status of each physical disk in the array. Predict Failure Predict Failure Predict Failure Predict Failure Predict Failure Tells whether SMART has determined that the disk will fail in the future. Size Size Size Size Size Shows the physical size of the drive. When the drive is part of an array, this shows the size used for the array.
6-42 6-42 6-42 6-42 6-42 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 6.4.4 6.4.4 6.4.4 6.4.4 6.4.4 Creating a RAID 1 (Mirror) set Creating a RAID 1 (Mirror) set Creating a RAID 1 (Mirror) set Creating a RAID 1 (Mirror) set Creating a RAID 1 (Mirror) set You can create two types of mirrored configuration using the LSI Logic Configuration Utility: Integrated Mirroring (IM) or RAID 1-E. See section 6.1.1 for RAID definitions. To create an RAID 1 set: 1. From the RAID Properties RAID Properties RAID Properties RAID Properties RAID Properties screen, select the drives that you want to include in the RAID 1 set. For Integrated Mirrored array, select first the drive with data that you want to retain. This drive will become the primary copy of the array. • Integrated Mirrored array - Select a minimum of two drives • RAID-1E - Select a minimum of four drives The Array Array Array Array Array label on top of the screen changes to IM or 1E depending on the number of selected hard disk drives. Integrated Mirroring Integrated Mirroring Integrated Mirroring Integrated Mirroring Integrated Mirroring RAID-1E RAID-1E RAID-1E RAID-1E RAID-1E
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-43 6-43 6-43 6-43 6-43 2. After selecting the drives, press <Esc>. 3. When prompted, select <Save changes, then exit this menu>, then press <Enter> to create the RAID 1 set.
6-44 6-44 6-44 6-44 6-44 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 2. After selecting the drives, press <Esc>. 3. When prompted, select <Save changes, then exit this menu>, then press <Enter> to create the RAID 0 set. 6.4.5 6.4.5 6.4.5 6.4.5 6.4.5 Creating a RAID 0 (Stripe) set Creating a RAID 0 (Stripe) set Creating a RAID 0 (Stripe) set Creating a RAID 0 (Stripe) set Creating a RAID 0 (Stripe) set You can create a striped array using the LSI Logic Configuration Utility. To create a RAID 0 set: 1. From the RAID Properties RAID Properties RAID Properties RAID Properties RAID Properties screen, select the drives that you want to include in the RAID 0 set. The Array Array Array Array Array label on top of the screen changes to IS (Integrated Striping).
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-45 6-45 6-45 6-45 6-45 Diagnostic Mode Diagnostic Mode Diagnostic Mode Diagnostic Mode Diagnostic Mode 6.4.6 6.4.6 6.4.6 6.4.6 6.4.6 Running the Diagnostic Mode Running the Diagnostic Mode Running the Diagnostic Mode Running the Diagnostic Mode Running the Diagnostic Mode Before creating the array, you may press <F4> to run a diagnostic tool on each drive in the system. After checking the drives, the diagnostic tool displays a code under the Size Size Size Size Size column of the RAID Properties screen. Refer to the table below for the description of the diagnostic codes. Code Code Code Code Code Description Description Description Description Description 1 Problem with reading disk serial number 2 Disk does not support SMART 3 Unused 4 Disk does not support wide data, synchrounous mode, or queue tagging 5 User disabled, disconnects, or queue tags for device (Device Properties) 6 Unused 7 Disk not big enough to mirror primary disk 8 Unused 9 Unused 10 Disk does not have 512 byte sector size 11 Incorrect device type 12 Hot Spare selection not big enough to be used as an array disk 13 Maximum disks already specified or Maximum array size would be exceeded
6-46 6-46 6-46 6-46 6-46 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration A tabbed menu appears on the top panel of the RAID Properties screen. You can now delete, add/delete hot spare drives, and/or activate arrays using the tabbed menus. Press <F2> to switch tabbed menus. 6.4.7 6.4.7 6.4.7 6.4.7 6.4.7 Managing arrays Managing arrays Managing arrays Managing arrays Managing arrays After creating the array, return to the Boot Adapter List Boot Adapter List Boot Adapter List Boot Adapter List Boot Adapter List screen, select the adapter, then press <Enter>. Select <RAID Properties> <RAID Properties> <RAID Properties> <RAID Properties> <RAID Properties> from the Adapter Properties screen, then press <Enter>.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-47 6-47 6-47 6-47 6-47 Deleting arrays Deleting arrays Deleting arrays Deleting arrays Deleting arrays To delete an array: 1. Press <F2> to select <Delete Array> <Delete Array> <Delete Array> <Delete Array> <Delete Array> . 2. Use the arrow keys to select the array you want to delete, then press <Enter>. 3. Press <Esc>. 4. When prompted, select <Save changes, then exit this menu> <Save changes, then exit this menu> <Save changes, then exit this menu> <Save changes, then exit this menu> <Save changes, then exit this menu> , then press <Enter>.
6-48 6-48 6-48 6-48 6-48 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration 2. Use the arrow keys to select the drive you want to assign as spare. 3. Move the selection to the Hot Spare Hot Spare Hot Spare Hot Spare Hot Spare column, then press <Enter>. Adding or deleting a hot spare drive Adding or deleting a hot spare drive Adding or deleting a hot spare drive Adding or deleting a hot spare drive Adding or deleting a hot spare drive To add a hot spare drive assigned to a RAID set: 1. From the RAID Properties screen, press <F2> to select <Add/Delete Hot Spare> <Add/Delete Hot Spare> <Add/Delete Hot Spare> <Add/Delete Hot Spare> <Add/Delete Hot Spare> .
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 6-49 6-49 6-49 6-49 6-49 4. Press <Esc>. 5. When prompted, select <Save changes, then exit this menu> <Save changes, then exit this menu> <Save changes, then exit this menu> <Save changes, then exit this menu> <Save changes, then exit this menu> , then press <Enter>. To delete a hot spare drive assigned to a RAID set: 1. From the RAID Properties screen, press <F2> to select <Add/Delete Hot Spare> <Add/Delete Hot Spare> <Add/Delete Hot Spare> <Add/Delete Hot Spare> <Add/Delete Hot Spare> . 2. Use the arrow keys to select the spare drive you want to delete. 3. Move the selection to the Hot Spare Hot Spare Hot Spare Hot Spare Hot Spare column, then press <Enter> to change the Hot Spare status to [No] [No] [No] [No] [No] . 4. Press <Esc>. 5. When prompted, select <Save changes, then exit this menu> <Save changes, then exit this menu> <Save changes, then exit this menu> <Save changes, then exit this menu> <Save changes, then exit this menu> , then press <Enter>. Next Array Next Array Next Array Next Array Next Array The Next Array menu allows you to select the other array on the physical adapter. This screen is enabled when there are more than one array on a physical adapter. The RAID Properties screen allows display of one array at a time. This menu allows you to display and operate on the other array(s) detected. Activate Array Activate Array Activate Array Activate Array Activate Array When there are two arrays on a physical adapter, this menu allows you to instruct the RAID firmware to activate a selected array. Only one array may be activated at a time for each physical adapter. For a physical adapter with multiple arrays, activating one array disables all the remaining arrays.
6-50 6-50 6-50 6-50 6-50 Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration Chapter 6: RAID configuration
3-1 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 This chapter provides information on RAID configurations, RAID driver installation, and LAN driver installation for this motherboard. Chapter 7 Driver installation
7-2 7-2 7-2 7-2 7-2 Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation 7.1 RAID driver installation After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides instructions on how to install the RAID controller drivers during OS installation. 7.1.1 7.1.1 7.1.1 7.1.1 7.1.1 Creating a RAID driver disk Creating a RAID driver disk Creating a RAID driver disk Creating a RAID driver disk Creating a RAID driver disk You may have to use another system to create the RAID driver disk from the system/motherboard support CD or from the Internet. A floppy disk with the RAID driver is required when installing Windows ® 2000/XP or Red Hat ® Enterprise ver. 3.0/SuSE operating system on a hard disk drive that is included in a RAID set. You can create a RAID driver disk in DOS (using the Makedisk application in the support CD). To create a RAID driver disk in DOS environment: 1. Place the motherboard support CD in the optical drive. 2. Restart the computer, then enter the BIOS Setup. 3. Select the optical drive as the first boot priority to boot from the support CD. Save your changes, then exit the BIOS Setup. 4. Restart the computer. 5. Press any key when prompted to boot from CD. The Makedisk menu appears. Loading FreeDOS FAT KERNEL GO! Press any key to boot from CDROM... 6. Place a blank, high-density floppy disk to the floppy disk drive, then select the type of RAID driver disk you want to create by typing the number before the option 7. Press <Enter>. 8. Follow screen instructions to create the driver disk. For systems with Red Hat ® Enterprise versions that are not listed in the Makedisk menu, explore the support CD and copy the RAID driver disk from the following path: \Drivers\Chipset\ICH\LSI\Driver\Linux \Drivers\Chipset\ICH\LSI\Driver\Linux \Drivers\Chipset\ICH\LSI\Driver\Linux \Drivers\Chipset\ICH\LSI\Driver\Linux \Drivers\Chipset\ICH\LSI\Driver\Linux .
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 7-3 7-3 7-3 7-3 7-3 7.1.2 7.1.2 7.1.2 7.1.2 7.1.2 Installing the RAID controller driver Installing the RAID controller driver Installing the RAID controller driver Installing the RAID controller driver Installing the RAID controller driver Windows Windows Windows Windows Windows ® ® ® ® ® 2000/2003 Server OS 2000/2003 Server OS 2000/2003 Server OS 2000/2003 Server OS 2000/2003 Server OS During Windows During Windows During Windows During Windows During Windows ® ® ® ® ® 2000/2003 Server OS installation 2000/2003 Server OS installation 2000/2003 Server OS installation 2000/2003 Server OS installation 2000/2003 Server OS installation To install the RAID controller driver when installing Windows ® 2000/ 2003 Server OS: 1. Boot the computer using the Windows ® 2000/2003 Server installation CD. The Windows Windows Windows Windows Windows ® ® ® ® ® 2000/2003 Setup 2000/2003 Setup 2000/2003 Setup 2000/2003 Setup 2000/2003 Setup starts. 2. Press <F6> when the message “ Press F6 if you need to install Press F6 if you need to install Press F6 if you need to install Press F6 if you need to install Press F6 if you need to install a third party SCSI or RAID driver... a third party SCSI or RAID driver... a third party SCSI or RAID driver... a third party SCSI or RAID driver... a third party SCSI or RAID driver... ” appears at the bottom of the screen. 3. When prompted, press < S S S S S > to specify an additional device.
7-4 7-4 7-4 7-4 7-4 Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation 4. Insert the RAID driver disk you created earlier to the floppy disk drive, then press <Enter>. 5. Select the RAID controller driver from the list, then press <Enter>. • For Intel Intel Intel Intel Intel ® ® ® ® ® ICH7R LSI Logic Embedded SATA RAID ICH7R LSI Logic Embedded SATA RAID ICH7R LSI Logic Embedded SATA RAID ICH7R LSI Logic Embedded SATA RAID ICH7R LSI Logic Embedded SATA RAID driver, select LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID . • For LSI53C1020A PCI-X SCSI controller LSI53C1020A PCI-X SCSI controller LSI53C1020A PCI-X SCSI controller LSI53C1020A PCI-X SCSI controller LSI53C1020A PCI-X SCSI controller driver, select LSI LSI LSI LSI LSI Logic PCI/SCSI/FC MPI Miniport Driver Logic PCI/SCSI/FC MPI Miniport Driver Logic PCI/SCSI/FC MPI Miniport Driver Logic PCI/SCSI/FC MPI Miniport Driver Logic PCI/SCSI/FC MPI Miniport Driver (P5MT/SCSI model only). 6. The Windows ® 2000/2003 Setup loads the RAID controller drivers from the RAID driver disk. When prompted, press <Enter> to continue installation. 7. Setup then proceeds with the OS installation. Follow screen instructions to continue.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 7-5 7-5 7-5 7-5 7-5 5. Right-click the RAID controller RAID controller RAID controller RAID controller RAID controller item, then select Properties Properties Properties Properties Properties . 6. Click the Driver Driver Driver Driver Driver tab, then click the Update Driver Update Driver Update Driver Update Driver Update Driver button. 7. The Upgrade Device Driver Wizard Upgrade Device Driver Wizard Upgrade Device Driver Wizard Upgrade Device Driver Wizard Upgrade Device Driver Wizard window appears. Click Next Next Next Next Next . 8. Insert the RAID driver disk you created earlier to the floppy disk drive. 9. Select the option “ Search for a suitable driver for my device Search for a suitable driver for my device Search for a suitable driver for my device Search for a suitable driver for my device Search for a suitable driver for my device (recommended) (recommended) (recommended) (recommended) (recommended) , then click Next Next Next Next Next . 10. The wizard searches the RAID controller drivers. When found, click Next Next Next Next Next t o install the drivers. 11. Click Finish Finish Finish Finish Finish after the driver installation is done. To an existing Windows To an existing Windows To an existing Windows To an existing Windows To an existing Windows ® ® ® ® ® 2000/2003 Server OS 2000/2003 Server OS 2000/2003 Server OS 2000/2003 Server OS 2000/2003 Server OS To install the RAID controller driver on an existing Windows ® 2000/ 2003 Server OS: 1. Restart the computer, then log in with Administrator Administrator Administrator Administrator Administrator privileges. 2. Windows ® automatically detects the RAID controller and displays a New Hardware Found New Hardware Found New Hardware Found New Hardware Found New Hardware Found window. Click Cancel Cancel Cancel Cancel Cancel . 3. Right-click the My Computer My Computer My Computer My Computer My Computer icon on the Windows ® desktop , then select Properties Properties Properties Properties Properties from the menu. 4. Click the Hardware Hardware Hardware Hardware Hardware tab, then click the Device Manager Device Manager Device Manager Device Manager Device Manager button to display the list of devices installed in the system.
7-6 7-6 7-6 7-6 7-6 Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation To verify the RAID controller driver installation: 1. Right-click the My Computer My Computer My Computer My Computer My Computer icon on the Windows ® desktop , then select Properties Properties Properties Properties Properties from the menu. 2. Click the Hardware Hardware Hardware Hardware Hardware tab, then click the Device Manager Device Manager Device Manager Device Manager Device Manager button. 3. Click the “ ” sign before the item SCSI and RAID controllers SCSI and RAID controllers SCSI and RAID controllers SCSI and RAID controllers SCSI and RAID controllers . • For P5MT model, the LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID item should appear. • For P5MT/SCSI model, the LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID item and the LSI Logic PCI/SCSI/FC MPI Miniport Driver LSI Logic PCI/SCSI/FC MPI Miniport Driver LSI Logic PCI/SCSI/FC MPI Miniport Driver LSI Logic PCI/SCSI/FC MPI Miniport Driver LSI Logic PCI/SCSI/FC MPI Miniport Driver items should appear. 4. Right-click the RAID controller driver item, then select Properties Properties Properties Properties Properties from the menu. 5. Click the Driver Driver Driver Driver Driver tab, then click the Driver Details Driver Details Driver Details Driver Details Driver Details button to display the RAID controller drivers. 6. Click OK OK OK OK O K when finished.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 7-7 7-7 7-7 7-7 7-7 Red Hat Red Hat Red Hat Red Hat Red Hat ® ® ® ® ® Enterprise ver. 3.0 Enterprise ver. 3.0 Enterprise ver. 3.0 Enterprise ver. 3.0 Enterprise ver. 3.0 To install the Intel ® ICH7R LSI Logic Embedded SATA RAID controller driver when installing Red Hat ® Enterprise ver. 3.0 OS: 1. Boot the system from the Red Hat ® Installation CD. 2. At the boot: , type linux dd , then press <Enter>.
7-8 7-8 7-8 7-8 7-8 Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation 4. Select fd0 fd0 fd0 fd0 fd0 using the <Tab> key when asked to select the driver disk source. Press <Tab> to move the cursor to OK OK OK OK O K, then press <Enter>. 3. Select Yes Yes Yes Yes Yes using the <Tab> key when asked if you have the driver disk. Press <Enter>
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 7-9 7-9 7-9 7-9 7-9 6. When asked if you will load additional RAID controller drivers: • For P5MT model, select No No No No N o, then press <Enter> • For P5MT/SCSI model, select Yes Yes Yes Yes Yes , then install the additional RAID controller drivers (for LSI53C1020A PCI-X SCSI controller). 7. Follow screen instructions to continue the OS installation. 5. When prompted, insert the Red Hat ® Enterprise ver. 3.0 RAID driver disk to the floppy disk drive, select OK, OK, OK, OK, OK, then press <Enter>. The drivers for the RAID controller are installed to the system.
7-10 7-10 7-10 7-10 7-10 Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation SuSE Linux SuSE Linux SuSE Linux SuSE Linux SuSE Linux To install the RAID controller driver when installing SuSE Linux OS: 1. Boot the system from the SuSE Installation CD. 2. Select Installation from the Boot Options Boot Options Boot Options Boot Options Boot Options menu, then press <Enter>. 3. A message instructs you to prepare the RAID driver disk. Press <F6>.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 7-11 7-11 7-11 7-11 7-11 4. When prompted, insert the RAID driver disk to the floppy disk drive, then press <Enter>. 5. When prompted, select the floppy disk drive (fd0) as the driver update medium, select OK, then press <Enter>. The drivers for the RAID controller are installed to the system.
7-12 7-12 7-12 7-12 7-12 Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation 7.2 LAN driver installation This section provides instructions on how to install the Broadcom ® Gigabit LAN controller drivers. 7.2.1 7.2.1 7.2.1 7.2.1 7.2.1 Windows Windows Windows Windows Windows ® ® ® ® ® 2000/2003 Server 2000/2003 Server 2000/2003 Server 2000/2003 Server 2000/2003 Server To install the Broadcom ® Gigabit LAN controller driver on a Windows ® 2000/2003 Server OS: 1. Restart the computer, then log on with Administrator Administrator Administrator Administrator Administrator privileges. 2. Insert the motherboard/system support CD to the optical drive. The CD automatically displays the Drivers Drivers Drivers Drivers Drivers menu if Autorun is enabled in your computer. • Windows ® automatically detects the LAN controllers and displays a New Hardware Found New Hardware Found New Hardware Found New Hardware Found New Hardware Found window. Click Cancel Cancel Cancel Cancel Cancel t o close this window. • If Autorun Autorun Autorun Autorun Autorun i s NOT enabled in your computer, browse the contents of the support CD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE ASSETUP.EXE ASSETUP.EXE ASSETUP.EXE ASSETUP.EXE t o run the CD. 3. Click the Broadcom Lan Driver Broadcom Lan Driver Broadcom Lan Driver Broadcom Lan Driver Broadcom Lan Driver option to begin installation.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 7-13 7-13 7-13 7-13 7-13 7.2.2 7.2.2 7.2.2 7.2.2 7.2.2 Red Hat Red Hat Red Hat Red Hat Red Hat ® ® ® ® ® Enterprise ver. 3.0 Enterprise ver. 3.0 Enterprise ver. 3.0 Enterprise ver. 3.0 Enterprise ver. 3.0 Follow these instructions when installing the Broadcom ® Gigabit LAN controller base driver for the Red Hat ® Enterprise ver. 3.0 operating system. Building the driver from the TAR file Building the driver from the TAR file Building the driver from the TAR file Building the driver from the TAR file Building the driver from the TAR file Install first the Kernel Development Kernel Development Kernel Development Kernel Development Kernel Development tools before building the driver from the TAR file. 4. Click Next Next Next Next Next when the InstallShield Wizard window appears. Follow screen instructions to continue installation. To build the driver from the TAR file: 1. Create a directory and extract the TAR files: tar xvzf bcm5700-<version>.tar.gz 2. Build the driver bcm5700.o as a loadable module for the running kernel: cd bcm5700-<version>/src make 3. Test the driver by loading it: insmod bcm5700.o 4. Install the driver and man page: make install 5. Refer to Red Hat distribution documentation to configure the network protocol and address.
7-14 7-14 7-14 7-14 7-14 Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation 7.3 VGA driver installation This section provides instructions on how to install the ATI ® RAGE XL Video Graphics Adapter (VGA) driver. 7.3.1 7.3.1 7.3.1 7.3.1 7.3.1 Windows Windows Windows Windows Windows ® ® ® ® ® 2000 Server 2000 Server 2000 Server 2000 Server 2000 Server You need to manually install the ATI ® RAGE XL VGA driver on a Windows ® 2000 Server operating system. To install the ATI ® RAGE XL VGA driver: 1. Restart the computer, then log on with Administrator Administrator Administrator Administrator Administrator privileges. 2. Insert the motherboard/system support CD to the optical drive. The support CD automatically displays the Drivers Drivers Drivers Drivers Drivers menu if Autorun is enabled in your computer. Windows ® automatically detects the LAN controller and displays a New New New New New Hardware Found Hardware Found Hardware Found Hardware Found Hardware Found window. Click Cancel Cancel Cancel Cancel Cancel t o close this window. 3. Click the item ATI ATI ATI ATI ATI Rage XL Display Rage XL Display Rage XL Display Rage XL Display Rage XL Display Driver Driver Driver Driver Driver from the Drivers Drivers Drivers Drivers Drivers menu. 4. The ATI ATI ATI ATI ATI Windows Windows Windows Windows Windows 2000 Driver 2000 Driver 2000 Driver 2000 Driver 2000 Driver window appears. Click Next Next Next Next N e x t. Follow screen instructions to complete installation.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 7-15 7-15 7-15 7-15 7-15 7.3.2 7.3.2 7.3.2 7.3.2 7.3.2 Windows Windows Windows Windows Windows ® ® ® ® ® 2003 Server 2003 Server 2003 Server 2003 Server 2003 Server The Windows ® 2003 Server operating system automatically recognizes the ATI ® RAGE XL VGA driver during system installation. There is no need to install an additional driver(s) to support the onboard VGA. 7.3.3 7.3.3 7.3.3 7.3.3 7.3.3 Red Hat Red Hat Red Hat Red Hat Red Hat ® ® ® ® ® Enterprise ver. 3.0 Enterprise ver. 3.0 Enterprise ver. 3.0 Enterprise ver. 3.0 Enterprise ver. 3.0 The Red Hat ® Enterprise ver. 3.0 operating system automatically recognizes the ATI ® RAGE XL VGA driver during system installation. There is no need to install an additional driver(s) to support the onboard VGA.
7-16 7-16 7-16 7-16 7-16 Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation 7.4 Management applications and utilities installation The support CD that came with the motherboard package contains the drivers, management applications, and utilities that you can install to avail all motherboard features. The contents of the support CD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for updates. 7.4.1 7.4.1 7.4.1 7.4.1 7.4.1 Running the support CD Running the support CD Running the support CD Running the support CD Running the support CD Place the support CD to the optical drive. The CD automatically displays the Drivers Drivers Drivers Drivers D r i v e r s menu if Autorun is enabled in your computer. If Autorun Autorun Autorun Autorun Autorun i s NOT enabled in your computer, browse the contents of the support CD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE ASSETUP.EXE ASSETUP.EXE ASSETUP.EXE ASSETUP.EXE t o run the CD. 7.4.2 7.4.2 7.4.2 7.4.2 7.4.2 Drivers menu Drivers menu Drivers menu Drivers menu Drivers menu The Drivers Drivers Drivers Drivers Drivers menu shows the available device drivers if the system detects installed devices. Install the necessary drivers to activate the devices. The screen display and driver options vary under different operating system versions.
ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 7-17 7-17 7-17 7-17 7-17 7.4.3 7.4.3 7.4.3 7.4.3 7.4.3 Management Software menu Management Software menu Management Software menu Management Software menu Management Software menu The Management Software Management Software Management Software Management Software Management Software menu displays the available network and server monitoring applications. Click on an item to install. 7.4.4 7.4.4 7.4.4 7.4.4 7.4.4 Utilities menu Utilities menu Utilities menu Utilities menu Utilities menu The Utilities Utilities Utilities Utilities Utilities menu displays the software applications and utilities that the motherboard supports. Click on an item to install. 7.4.5 7.4.5 7.4.5 7.4.5 7.4.5 Contact information Contact information Contact information Contact information Contact information Click the Contact Contact Contact Contact Contact tab to display the ASUS contact information. You can also find this information on the inside front cover of this user guide.
7-18 7-18 7-18 7-18 7-18 Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation Chapter 7: Driver installation
3-1 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 This section provides information about the power supply unit and a troubleshooting guide for solving common problems when using the barebone server. Appendix Reference information
Appendix: Reference information Appendix: Reference information Appendix: Reference information Appendix: Reference information Appendix: Reference information A-2 A-2 A-2 A-2 A-2 A.1 450 W single power supply A.1.1 A.1.1 A.1.1 A.1.1 A.1.1 General description General description General description General description General description The 450 W SSI-type single power supply with universal AC input includes PFC and ATX-compliant output cables and connectors. The power supply has 13 plugs labeled P1 to P13. Take note of the devices to which you should connect the plugs. P2 P2 P2 P2 P2 P11 P11 P11 P11 P11 P5 P5 P5 P5 P5 P6 P6 P6 P6 P6 P1 P1 P1 P1 P1 P10 P10 P10 P10 P10 P9 P9 P9 P9 P9 P P P P P 12 12 12 12 12 P13 P13 P13 P13 P13 P7 P7 P7 P7 P7 P2 P2 P2 P2 P 2 Motherboard 4-pin 12V power connector P1 P1 P1 P1 P 1 Motherboard 24-pin ATX power connector P12 P12 P12 P12 P 1 2 Peripheral device (available); connect this to the SCSI/SATA backplane P9 P9 P9 P9 P 9 Floppy disk drive P13 P13 P13 P13 P 1 3 Peripheral device (available) P5 P5 P5 P5 P 5 Peripheral device (available) P6 P6 P6 P6 P 6 Peripheral device (available) P7 P7 P7 P7 P 7 Peripheral device (available); connect this to the SCSI/SATA backplane P10 P10 P10 P10 P 1 0 Peripheral device (available); optical drive P11 P11 P11 P11 P 1 1 Peripheral device (available) P8 P8 P8 P8 P 8 Peripheral device (available) P3 P3 P3 P3 P 3 Serial ATA device P4 P4 P4 P4 P 4 Serial ATA device P8 P8 P8 P8 P8 P3 P3 P3 P3 P3 P4 P4 P4 P4 P4
A-3 A-3 A-3 A-3 A-3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 A.1.2 A.1.2 A.1.2 A.1.2 A.1.2 Specifications Specifications Specifications Specifications Specifications DC Output characteristics DC Output characteristics DC Output characteristics DC Output characteristics DC Output characteristics Output Voltage Output Voltage Output Voltage Output Voltage Output Voltage Max (A) Max (A) Max (A) Max (A) Max (A) 3.33V 24 5V 24 12V 43 -12V 0.5 -5V 0.5 5VSB 2.0 Input Characteristics Input Characteristics Input Characteristics Input Characteristics Input Characteristics Input Voltage Range Input Voltage Range Input Voltage Range Input Voltage Range Input Voltage Range Normal Range 110 to 127 V ~ 10 A Auto Range 200 to 240 V ~ 5 A Input Frequency Range Input Frequency Range Input Frequency Range Input Frequency Range Input Frequency Range 5 0 H z t o 6 0 H z
Appendix: Reference information Appendix: Reference information Appendix: Reference information Appendix: Reference information Appendix: Reference information A-4 A-4 A-4 A-4 A-4 A.2 Simple fixes The power LED on the The power LED on the The power LED on the The power LED on the The power LED on the server or on the monitor server or on the monitor server or on the monitor server or on the monitor server or on the monitor do not light up do not light up do not light up do not light up do not light up 1. Check if the power cable is properly connected to the power connector in the system rear panel. 2. Make sure that the power cables are connected to a grounded power outlet. 3. Press the power button to make sure that the system is turned on. The keyboard does not The keyboard does not The keyboard does not The keyboard does not The keyboard does not work work work work work Check if the keyboard cable is properly connected to the PS/2 keyboard port. The mouse does not work The mouse does not work The mouse does not work The mouse does not work The mouse does not work Check if the mouse cable is properly connected to the mouse port. The system does not The system does not The system does not The system does not The system does not perform power-on self perform power-on self perform power-on self perform power-on self perform power-on self tests (POST) after it was tests (POST) after it was tests (POST) after it was tests (POST) after it was tests (POST) after it was turned on turned on turned on turned on turned on 1. Check the memory modules and make sure you installed the DIMMs the system supports. 2. Make sure that the DIMMs are properly installed on the sockets. Problem Problem Problem Problem Problem Action Action Action Action Action Some problems that you may encounter are not due to defects on the system or the components. These problems only requires simple troubleshooting actions that you can perform by yourself.
A-5 A-5 A-5 A-5 A-5 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 ASUS TS300-E3 Problem Problem Problem Problem Problem Action Action Action Action Action The system continuously The system continuously The system continuously The system continuously The system continuously beeps after it was turned beeps after it was turned beeps after it was turned beeps after it was turned beeps after it was turned on on on on on 1. Check the memory modules and make sure you installed supported DIMMs. 2. Make sure that the DIMMs are properly installed on the sockets. The message “Non-system The message “Non-system The message “Non-system The message “Non-system The message “Non-system disk or disk error” disk or disk error” disk or disk error” disk or disk error” disk or disk error” appears appears appears appears appears 1. Check if a bootable HDD is active. 2. Check if the HDDs are properly installed. Network connection not Network connection not Network connection not Network connection not Network connection not available available available available available 1. Make sure that the network cable is connected to the LAN port on the rear panel. 2. Make sure that you have installed the LAN drivers from the support CD.
Appendix: Reference information Appendix: Reference information Appendix: Reference information Appendix: Reference information Appendix: Reference information A-6 A-6 A-6 A-6 A-6