HP ProLiant DL370 Quickspecs
HP ProLiant DL370 G6 (Rack) HP ProLiant DL370 G6 (Rack) HP ProLiant DL370 G6 (Rack) HP ProLiant DL370 G6 (Rack) Front View: Front View: Front View: Front View: Rear View: Rear View: Rear View: Rear View: 1. Quick removal access panel 1. Mouse connector 2. Three Hot-plug fans (standard) Five (optional) 2. Keyboard connector 3. Intel Quad-Core Processor (Performance model includes two processors) 3. Serial connector 4. iLO 2 connector 4. Eighteen slots for DDR3 Registered or Unbuffered Memory 5. Two USB connectors 5. SAS/SATA drive cage 6. 9 Available PCI-Express Gen2 expansion slots 6. Optional drive cage bay 7. Expansion slot riser bay 7. Power on/stanby button 8. Four NIC connectors 8. System Insight Display 9. Video connector 9. Removal media bay 10. Power supply bay 2 10. DVD-ROM drive 11. Power supply bay 1 (populated) 11. Optional slimline optical drive bay 12. 9 Available PCI-Express Gen2 slots QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Overview DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 1
HP ProLiant ML370 G6 (Tower) HP ProLiant ML370 G6 (Tower) HP ProLiant ML370 G6 (Tower) HP ProLiant ML370 G6 (Tower) Front View: Front View: Front View: Front View: Rear View: Rear View: Rear View: Rear View: 1. Three Hot-plug fans (standard) Five (optional) 1. Expansion slot riser bay 2. Quick removal access panel 2. Four NIC connectors 3. Intel Quad-Core Processor (Performance model includes two processors) 3. Serial connector 4. Power supply bay 2 4. Eighteen slots for DDR3 Registered or Unbuffered Memory 5. Power supply bay 1 (populated) 5. SAS/SATA drive cage 6. Mouse connector 6. Optional drive cage bay 7. Keyboard connector 7. Power on/stanby button 8. Video connector 8. System Insight Display 9. Two USB connectors 9. Removal media bay 10. iLO 2 connector 10. DVD-ROM drive 11. 9 Available PCI-Express Gen2 expansion slots 11. Optional slimline optical drive bay 12. 9 Available PCI-Express Gen2 slots At A Glance At A Glance At A Glance At A Glance The next generation of the HP ProLiant ML370 (expandable tower chassis) and the new HP ProLiant DL370 (4U rack optimized chassis) deliver Industry-leading management tools, leading performance, expandability, flexibility and the latest energy efficient technologies. These servers are well-suited for deployment in growing businesses, remote office sites, or datacenters and have been designed to bring you (our customer) the utmost confidence to run your business. Features included in both the HP ProLiant ML370 G6 and the HP ProLiant DL370 G6: Processors: Processors: Processors: Processors: Up to two Intel® Xeon® 5500 Series processors Intel® 5520 chipset Memory: Memory: Memory: Memory: 18 DIMM slots Up to 144GB, using PC3-8500R DDR3 Registered (RDIMM) memory, operating at 800MHz when fully populated at 3 DIMMs per Channel in 18 slots. Up to 24GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully populated at 2 DIMMs per Channel in 12 slots. QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Overview DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 2
Storage Controller: Storage Controller: Storage Controller: Storage Controller: Entry Models: HP Smart Array P410i/256 MB Controller (RAID 0/1/1 0/5/5 0) NOTE: NOTE: NOTE: NOTE: Entry Models available for ML370 G6 models only. Base Models: HP Smart Array P410i/256 MB Controller (RAID 0/1/1 0/5/5 0) Performance Models: HP Smart Array P410i/512 MB BBWC Controller (RAID 0/1/1 0/5/5 0 Available upgrades: 256MB, 512MB with BBWC, Battery kit upgrade (for BBWC), and Smart Array Advanced Pack (SAAP) Internal Drive Support: Internal Drive Support: Internal Drive Support: Internal Drive Support: Up to 24 small form factor (SFF) or 14 large form factor (LFF) hot-plug drive bays to support Serial-attached SCSI (SAS) and Serial ATA (SATA) drives Standard half-height DVD-ROM (all models) Two open half-height media bays available for tape drives, optical media, optional SAS HDD cage Network Controller: Network Controller: Network Controller: Network Controller: HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Expansion Slots: Expansion Slots: Expansion Slots: Expansion Slots: Nine PCIe2 slots available (see "Standard Features -Expansion Slots" section below for more details) Graphic Cards Graphic Cards Graphic Cards Graphic Cards : Supports up to 3 x 300W Graphic Cards via Graphic Card Power Adapter kit NOTE: NOTE: NOTE: NOTE: 2 PCIe Gen2 x16 (mechanical/electrical); 1 PCIe Gen2 x16 (mechanical) x8 (electrical) Ports: Ports: Ports: Ports: USB 2.0 support 5 total ports: (2) ports up front; (2) ports in back; (1) port internal 1 internal Secure Digital (SD) slot Redundancy: Redundancy: Redundancy: Redundancy: Multiple layers of fault tolerance through critical component redundancy (power supply and fan redundancy), mirrored memory, embedded RAID capability, and full-featured remote Lights-Out management Power Sources: Power Sources: Power Sources: Power Sources: Dual Common Slot Bay for Right Sized, Hot plug and Redundant Power options HP 1200W CS HE Silver Power Supply (optional) HP 750W CS HE Gold Power Supply (standard on some models) HP 460W CS HE Gold Power Supply (standard on some models) Management: Management: Management: Management: HP Insight Control suite server management software HP ProLiant Onboard Administrator (powered by the HP Integrated Lights-Out 2 management processor) for simplified server setup, health monitoring and recovery, power and thermal control, and lights-out remote administration. Integrated Lights-Out 2 Advanced unlocks the full capabilities of the ProLiant Onboard Administrator with high performance Integrated Remote Console, multi-user console sharing, video record and replay, and virtual media, including virtual folders for rapid server updates. Convenient Systems Insight Display for quick and easy front view server diagnostics ProLiant Essential Foundation Pack standard, including HP Systems Insight Manager, SmartStart, SmartStart Scripting Toolkit, Subscriber's Choice and ROM Based Setup Utility (RBSU) Automatic Server Recovery (ASR), ROM Based Setup Utility (RBSU), HP System Insight Manager, Status LEDs including system health, UID, and SmartStart Form Factor: Form Factor: Form Factor: Form Factor: 4U Tower Chassis and 4U Rack Optimized Chassis Redesigned 4U Tower Chassis and the new 4U Rack Optimized Chassis to better meet our customer's density requirements Operating Systems: Operating Systems: Operating Systems: Operating Systems: Supports Windows, RHEL, SLES, OEL, Solaris, VMware, and Citrix Essentials for XenServer Deployment/Serviceability: Deployment/Serviceability: Deployment/Serviceability: Deployment/Serviceability: Quick Deploy Rail System includes sliding universal rails, an ambidextrous cable management arm and quick release levers for fast and easy serviceability QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Overview DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 3
Tool-less access to all system components for easy in rack serviceability Customer Self Repair (CSR): HP products are designed with many CSR parts to minimize repair time and allow for greater flexibility in performing defective parts replacement Warranty: Warranty: Warranty: Warranty: This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners resellers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. SATA hard drives have a one-year warranty. SAS Enterprise drives have a three-year warranty. NOTE: NOTE: NOTE: NOTE: Server Warranty includes 3-Year Parts, 3-Year Labor, 3-Year Onsite support with next business day response. Warranty repairs may be accomplished through the use of Customer Self Repair (CSR) parts. These parts fall into two categories: 1) Mandatory CSR parts are designed for easy replacement. A travel and labor charge will result when customers decline to replace a Mandatory CSR part; 2) Optional CSR parts are also designed for easy replacement but may involve added complexity. Customers may choose to have HP replace Optional CSR parts at no charge. Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Overview DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 4
NOTE: NOTE: NOTE: NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. Processor Processor Processor Processor One of the following depending on Model Quad-Core Processors Quad-Core Processors Quad-Core Processors Quad-Core Processors Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) Dual-Core Processors Dual-Core Processors Dual-Core Processors Dual-Core Processors Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) NOTE: NOTE: NOTE: NOTE: Up to 2 processors supported. Performance configurations include two processors. Mixing different processor models is not supported. NOTE: NOTE: NOTE: NOTE: HT indicates that the processor model supports Intel® Hyper-Threading Technology. NOTE: NOTE: NOTE: NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active. NOTE: NOTE: NOTE: NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: NOTE: NOTE: NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. Cache Memory Cache Memory Cache Memory Cache Memory One of the following depending on Model 8MB (1 x 8MB) Level 3 cache NOTE: NOTE: NOTE: NOTE: All processor models except for those identified below. 4MB (1 x 4MB) Level 3 cache NOTE: NOTE: NOTE: NOTE: For processors E5506/E5504/E5502. Chipset Chipset Chipset Chipset Intel® 5520 chipset NOTE: NOTE: NOTE: NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/ . Upgradeability Upgradeability Upgradeability Upgradeability Upgradeable to 2 processors Memory Protection Memory Protection Memory Protection Memory Protection Advanced ECC Mirroring mode Lock-step mode QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 5
Memory Memory Memory Memory Type DDR3 Registered (RDIMM) or Unbuffered (UDIMM) Standard (Performance Models) 12 GB (6 x 2 GB) RDIMM Standard (Base Models) 6 GB (3 x 2 GB) RDIMM Standard (Entry Model) 4 GB (2 x 2 GB) UDIMM Maximum (RDIMM) 144 GB (18 x 8 GB) for Registered Memory configurations Maximum (UDIMM) 24 GB (12 x 2 GB) for Unbuffered Memory configurations NOTE: NOTE: NOTE: NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator . DDR3 memory options part number decoder DDR3 memory options part number decoder DDR3 memory options part number decoder DDR3 memory options part number decoder Network Controller Network Controller Network Controller Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Expansion Slots Expansion Slots Expansion Slots Expansion Slots Expansion Slots Expansion Slots Expansion Slots Expansion Slots # # # # Technology Technology Technology Technology Width Width Width Width Connector Connector Connector Connector Width Width Width Width * Form Factor Form Factor Form Factor Form Factor Notes Notes Notes Notes 1 PCIe x4 x8 Half length, full height slot 2 PCIe2 x4 x8 Full length, full height slot 3 PCIe2 x16 x16 Full length, full height slot 4 PCIe2 x4 x8 Full length, full height slot 5 PCIe2 x4 x8 Full length, full height slot 6 PCIe2 x8 x16 Full length, full height slot 7 PCIe2 x4 x8 Full length, full height slot QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 6
8 PCIe2 x16 x16 Full length, full height slot 9 PCIe2 x4 x8 Full length, full height slot 10 PCIe2 X8 X8 Half length, full height slot Utilized by NIC controller "Use the correct model number for the NIC" * Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number. Storage Controller Storage Controller Storage Controller Storage Controller One of the following depending on Model Entry Models HP Smart Array P410i/256 MB Controller (RAID 0/1/1 0/5/5 0) Base Models HP Smart Array P410i/256 MB Controller (RAID 0/1/1 0/5/5 0) Performance Models HP Smart Array P410i/512 MB BBWC Controller (RAID 0/1/1 0/5/5 0/6) Available upgrades: 256MB, 512MB with BBWC, Battery kit upgrade (for BBWC), and Smart Array Advanced Pack (SAAP). Storage Storage Storage Storage Diskette Drive None Standard Optical Drive SATA DVD ROM (standard in all models) Hard Drives None Standard Maximum Internal Maximum Internal Maximum Internal Maximum Internal Storage Type Storage Type Storage Type Storage Type Hot Plug SFF SAS 7.20TB 24 x 300GB Hot Plug LFF SAS 14 TB 14 x 1TB Interfaces Interfaces Interfaces Interfaces Serial 1 (rear) Pointing Device (Mouse) 1 VGA 1 ( 1 front VGA on rack models) Keyboard 1 Network RJ-45 4 (rear) ILO 2.0 remote management port 1 SD slot 1 USB 2.0 Ports 5 (2 on the rear, 2 on the front, 1 internal) NOTE: NOTE: NOTE: NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html Dedicated USB 2.0 Port 1 (available for DAT USB tape connectivity) NOTE: NOTE: NOTE: NOTE: Internal USB ports are optimal for the attachment of HP DAT USB Internal Tape Drives QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 7
Graphics Graphics Graphics Graphics Integrated ATI RN50, 64 MB video standard 16 bit color: maximum resolution of 1600 x 1200 32 bit color: maximum resolution of 1280 x 1024 NOTE: NOTE: NOTE: NOTE: Maximum resolution available via iLO 2 remote console is 1280 x 1024. Form Factor Form Factor Form Factor Form Factor 4U Rack and Tower form factor (7 in, 17.8 cm) HP Insight Control suite HP Insight Control suite HP Insight Control suite HP Insight Control suite HP Insight Control suite delivers essential management, including proactive health management, lights out remote control, optimization of power usage, rapid server deployment, performance analysis, vulnerability scanning and patch management and virtual machine management. HP Insight Control suite installs and licenses the following components by default using a wizard-based integrated installer: HP Systems Insight Manager HP iLO Advanced Pack HP Insight Rapid Deployment software HP Insight Power Manager software HP Insight Performance Manager module HP Insight Vulnerability and Patch Manager module HP Insight Virtual Machine Manager software for ProLiant Additional Insight Software standalone products and management tools included on the Insight Software media kit can be installed manually: HP Insight Server Migration software for ProLiant NOTE: NOTE: NOTE: NOTE: HP Insight Server Migration software for ProLiant is licensed separately from Insight Control suite. HP Insight Remote Support Standard HP Insight Remote Support Advanced (previously Service Essentials Remote Support Pack) NOTE: NOTE: NOTE: NOTE: HP Insight Server Migration software for ProLiant can be installed from the SMP CD included in the Insight Software media kit. NOTE: NOTE: NOTE: NOTE: For additional product and licensing information about HP Insight Control suite, visit: http://www.hp.com/go/ice . NOTE: NOTE: NOTE: NOTE: As of Feb. 1, 2009, HP iLO Power Management Pack is being discontinued. Customer can either purchase HP Insight Control suite which contains all the components of IPMP or the standalone components which include iLO Advanced, Insight Power Manager software and System Insight Manager. HP Insight Control Environment for Linux (ICE-Linux) provides comprehensive discovery, imaging & deployment, monitoring, and management for Linux-based ProLiant server platforms. Built on the industry-leading HP Systems Insight Manager framework, this solution integrates open source technology with experience leveraged from HP's Linux products in HP ICLE and HP XC Clusters, while providing paths to the future with developing management technologies. HP Insight Control suite and most HP Insight Software products include a one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 8
http://www.hp.com/services/insight . HP ProLiant Onboard HP ProLiant Onboard HP ProLiant Onboard HP ProLiant Onboard Administrator Administrator Administrator Administrator HP ProLiant Onboard Administrator (powered by the Integrated Lights-Out 2 management processor) simplifies server setup, health monitoring, power and thermal control, and lights-out remote administration of ProLiant ML, DL, and BL servers. HP ProLiant Onboard Administrator functions without additional software, and can be accessed from any location via a web browser. It works hand-in-hand with HP Systems Insight Manager, Insight Control, and Insight Dynamics - VSE suite helping customers unlock the value of the ProLiant platform and deliver the highest possible quality of IT service to the business. Capabilities of the HP ProLiant Onboard Administrator embedded in ProLiant ML/DL servers include, but are not limited to the following: Rom-based Setup Utility (RBSU) and Option Rom Configuration for Arrays (ORCA) IML and iLO event logging Automatic Server Recovery (ASR) OS independent hardware health status Present server power consumption Virtual Unit ID control Remote serial console Virtual power button control Dynamic Sector Repairing (with Smart Array controller) Drive Parameter Tracking (with Smart Array controller) Hot Spare Boot NOTE: NOTE: NOTE: NOTE: Upon the event of a failed processor in a multi-processing environment, the system will automatically reboot and attempt to use the remaining good processor. Unlock the full remote administration capabilities of HP ProLiant Onboard Administrator with Integrated Lights-Out 2 Advanced. Server Management Server Management Server Management Server Management Stand Alone Software Stand Alone Software Stand Alone Software Stand Alone Software Product - ProLiant Product - ProLiant Product - ProLiant Product - ProLiant Essentials Essentials Essentials Essentials HP Systems Insight Manager HP Systems Insight Manager (HP SIM) provides a unified, secure and extensible standards-based environment to centrally manage servers, storage and other infrastructure devices, (both HP and non-HP) across multiple operating system platforms. For additional information, please see: www.hp.com/go/insight HP Insight Rapid Deployment software HP Insight Rapid Deployment Software (RDP) extends HP Systems Insight Manager with a complete deployment solution for HP ProLiant servers. RDP provides a central location to configure server hardware, deploy Windows, Linux and VMware ESX operating environments and install HP ProLiant Support Pack drivers using images and scripted profiles. For more information, visit: http://www.hp.com/go/rdp . HP Server Migration Pack - Universal Edition Upgrading, replacing, or virtualizing your existing server? Effortlessly transition to new virtual or physical HP ProLiant servers or BladeSystem with automated, accurate and affordable migration of OS, application and data. SMP Universal automates the manual processes required for migrating servers between physical or virtual platforms, whether migrating to VMware or Microsoft virtual machines. SMP Universal allows all of the following migrations: QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 9
physical to ProLiant physical to virtual virtual to virtual virtual to ProLiant NOTE: NOTE: NOTE: NOTE: For more information, visit: http://www.hp.com/go/migrate . HP Insight Dynamics - VSE suite for ProLiant The HP Insight Dynamics - VSE suite for ProLiant is advanced infrastructure management software that allows you to analyze and optimize your adaptive infrastructure to manage physical and virtual resources in the same way. HP Insight Dynamics - VSE gives you a powerful toolkit to accelerate complex technology projects and simplify daily operations. It enables you to plan capacity and power continuously, balance across physical and virtual resources, ensure cost-effective high availability and provision infrastructure consistently. HP Insight Orchestration, an optional extension to Insight Dynamics - VSE, enables IT organizations to provision infrastructure consistently and automatically from pools of shared resources using a self-service portal. Resources provisioned can range from a single virtual machine to complex multi-tier environments and their associated physical and virtual resource requirements. HP Insight Recovery, also an optional extension for Insight Dynamics - VSE, enables cost-effective disaster recovery for physical and virtual environments. Application environments can be reactivated in minutes with the touch of a button to a remote location NOTE: NOTE: NOTE: NOTE: For more information, visit: http://www.hp.com/go/insightdynamics , http://www.hp.com/go/insightorchestration , www.hp.com/go/insightrecovery HP Integrated Lights-Out (iLO) Advanced Pack Unlocks the full capabilities of the ProLiant Onboard Administrator with comprehensive remote control including Virtual KVM remote graphical console, power management capabilities such as power measurement, regulation, and capping, new iLO Text Console, automatic and on-demand video recording of server events, global team collaboration for up to four remote users, virtual media (floppy, CD/DVD, USB key), virtual folders, and enterprise security (directory services and two-factor authentication). For additional information, please see: www.hp.com/go/iLO HP iLO Power Management Pack Energy-efficient management software that delivers centralized control, reliable security, and energy savings for your BladeSystem infrastructure. iPMP combines the total control of iLO 2 Advanced in the area of remote management with the energy monitoring and control of the Insight Power Manager to deliver a robust solution capable of full remote control and power management of ProLiant servers through a unified interface within HP Systems Insight Manager. For additional information, please see: www.hp.com/go/iLO HP Accelerated iSCSI Pack Enables the embedded Multifunction network controller to serve as both a NIC and an iSCSI HBA providing access to SAN storage over the same connection used for networking. Processing of the protocol stack is offloaded to the NIC reducing CPU utilization and greatly improving the speed with which the requests are processed and sent to the network. For additional information, please see: www.hp.com/go/iscsi QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 10
HP Insight Power Manager (IPM) Upgrades the single-server remote management capabilities of iLO Select/Advanced to include centralized reporting and policy-based management of power consumption and thermal output provided by the Insight Power Manager. IPM unifies all of this functionality within a single user interface - HP Systems Insight Manager. For additional information, please see: www.hp.com/go/ipm NOTE: NOTE: NOTE: NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to: http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. Core Infrastructure Core Infrastructure Core Infrastructure Core Infrastructure Management Management Management Management HP Foundation Pack Managing the growing number of servers can be complex and expensive for your organization. IT managers need to address changing business needs with tools that meet the challenges of managing today's complex Datacenters. HP provides management solutions that are designed to simplify a server's installation, configuration and maintenance throughout the entire server lifecyle. This provides the customer with higher levels of operational efficiency and highly reliable systems: www.hp.com/go/foundation . The foundation pack includes: HP SmartStart HP Management HP ProLiant Firmware Maintenance SmartStart version supported (minimum): SmartStart 8.20 http://www.hp.com/servers/smartstart NOTE: NOTE: NOTE: NOTE: In an effort to support reducing our environmental impact, the HP ProLiant Essentials Foundation Pack media will be available as a selectable option for this server at time of order of a CTO SKU. This will allow customers to order the number of media kits that best meet their needs and eliminate receiving unnecessary duplicate media. Insight Management Providers (WBEM) The HP Insight Management WBEM Providers leverage the rich set of base- level instrumentation provided by the system management controllers and drivers, I/O controllers and drivers, and system firmware interfaces delivering in-depth hardware management, including hardware inventory data, system state, and event notifications. Key Benefits Include: Heightened Security Single integrated Security Model Built using industry standard secure protocols and encryption algorithms (SSL, SSH) Reduce the number of entry points into internal network Reduced complexity of setup and configuration Delivers standards-based management across vendor platforms Robust in-depth and usable data that is provided to the HP System Management Homepage and Central Management Console Guaranteed event delivery Reduces overall load on the server by smaller agent footprint and maintenance burden QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 11
Provides in-depth hardware management, inventory data, system state, and event notifications The Insight Management Providers are included on ProLiant Support Packs. For additional information about the Management Providers please visit http://www.hp.com/go/HPwbem Insight Management Agents (SNMP) The Insight Management Agents should be installed on all HP servers to present system instrumentation, health and configuration information into HP Systems Insight Manager and the HP System Management Homepage. The HP System Management Homepage aggregates systems data from Insight Management Agents and other HP management tools, providing a consolidated browser-based interface for managing individual servers. Insight Management Agents and The HP System Management Homepage are included on ProLiant Support Packs, and can also be installed using the server profiles provided with the Rapid Deployment Pack. For additional information about the Management Agents and the HP System Management Homepage please visit the management Web site at: http://www.hp.com/servers/manage . Subscriber's Choice Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides software and driver change notifications for ProLiant products. Sign up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis. ProLiant Support Packs and ROMPaq, software The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options, available through ProLiant Support Packs the HP Insight Rapid Deployment Software, SmartStart or downloaded from software and drivers download pages website at: http://www.hp.com/go/support . HP Serviceguard for Linux HP Serviceguard for Linux HP Serviceguard for Linux HP Serviceguard for Linux (SGLX) (SGLX) (SGLX) (SGLX) HP Serviceguard for Linux provides high availability clustering for Linux applications running on HP Integrity, HP ProLiant and other supported industry-standard servers. Serviceguard for Linux reduces planned and unplanned downtime and delivers efficient, continuous access to business-critical applications - with all of the enterprise features you expect from HP. This high availability clustering solution is designed to protect applications and services from a wide variety of software and hardware failures, monitoring the health of each server (node) and quickly responding to failures such as those that affect system processes, system memory, LAN media and adapters, and application processes. For the most recent list of Linux distributions & kernels, servers and storage supported with Serviceguard for Linux, please see: ftp://ftp.compaq.com/pub/products/servers/ha/linux/SGLX_Certification_Matrix.pdf The following is a quick summary of HP Serviceguard for Linux features and support: Supported Virtual Machines SG/LX in HP Integrity Virtual Machines guests SG/LX in VMware ESX guests SG/LX in Red Hat and SUSE Xen hosts (DOM0) QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 12
Application Integration Toolkits HP Serviceguard for Linux Oracle Database Toolkit HP Serviceguard Extension for SAP on Linux (SGeSAP/LX) Free Application Integration Toolkits: Apache MySQL NFS PostgreSQL Samba Tomcat Sendmail Disaster Tolerant Solutions HP Serviceguard for Linux Extended Distance Cluster (XDC) extends cluster distances up to 100 km, utilizes software RAID mirroring for data replication and is storage array independent HP StorageWorks XP/EVA Cluster Extension Software for Linux (CLX) works seamlessly with HP Serviceguard for Linux, HP StorageWorks Continuous Access, and HP Disk Arrays to automate failover and failback between sites Software updates are distributed by HP Services to customers with support contracts NOTE: NOTE: NOTE: NOTE: For additional information including software and server support on HP Serviceguard for Linux, visit: http://www.hp.com/go/sglx or see the HP Serviceguard for Linux QuickSpecs. NOTE: NOTE: NOTE: NOTE: HP Serviceguard for Linux products for HP ProLiant and select 3rd party x86 class servers include one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/swsupport . Industry Standard Industry Standard Industry Standard Industry Standard Compliance Compliance Compliance Compliance ACPI V2.0 Compliant PCI-Express Gen2 PXE Support WOL Support Microsoft® Logo certifications USB 2.0 SMBIOS 2.6.1 Security Security Security Security Power-on password Keyboard password Diskette drive control Diskette boot control QuickLock, Network Server Mode Parallel and serial interface control Administrator's password QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 13
Security Trusted Platform Security Trusted Platform Security Trusted Platform Security Trusted Platform Module Module Module Module The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys. Windows® BitLocker⢠Drive Encryption (BitLocker) is a data protection feature available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running Windows Server 2008 has not been tampered with while the system was offline. For more information about TPM, including a white paper, go to www.hp.com/go/TPM NOTE: NOTE: NOTE: NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment. NOTE: NOTE: NOTE: NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing the key could result in data loss. Server Power Cords Server Power Cords Server Power Cords Server Power Cords High voltage power cord ships standard with all part numbers. Localized cables included with geographic specific models in other world regions. NOTE: NOTE: NOTE: NOTE: ProLiant DL servers no longer ship standard with NEMA power cords (187335-001) that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected to PDU's in data center racks so they now ship standard with only a PDU power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle (NEMA-15), the above NEMA power cord must be ordered separately. UPS Power Cord Matrix UPS Power Cord Matrix UPS Power Cord Matrix UPS Power Cord Matrix Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and specifications for UPS and PDU units: http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/index.html Power Supply Power Supply Power Supply Power Supply HP has a new design for ProLiant power. The new Common Slot Power Supply bay. This design provides the customer with commonality in power supplies across multiple platforms to save on the cost of spares and allows HP to offer multiple power solutions to fit the customers' needs. Many HP ProLiant Servers come with Common Slot, High Efficiency and Right-Size Power Supplies. Common Slot (CS) designates commonality of the power supply across multiple ProLiant servers. HP's new Common Slot power supplies are designed for highest efficiency to provide power efficiency without degrading performance of the ProLiant. Power Supplies will have efficiency ratings up to 92%. There are three Right Size power options available, depending on the configuration of your server. To make sure you select the correct power supply to meet your configuration, we suggest that you use the HP Power Advisor to decide the "Right-Size" for your configuration. All HP Common Slot power sources are UL, CE Mark Compliant, Hot Plug and Redundant. QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 14
Common Slot ProLiant Common Slot ProLiant Common Slot ProLiant Common Slot ProLiant It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for your needs. HP offers three Power Supply Options: 460Watts, Common Slot,92% Efficiency 750Watts, Common Slot, 92% Efficiency 1200Watts, Common Slot, 90% Efficiency HP's ProLiant Common Slot Power supplies (460W & 750W) meet multiple Energy Efficiency Initiatives. Climate Savers Computing Initiative GOLD, ECOS Consulting 80PLUS GOLD and plans on offering models that meet the Energy Star for Server requirements when they are published. HP's ProLiant Common Slot Power supplies (1200W) meet multiple Energy Efficiency Initiatives. Climate Savers Computing Initiative Bronze, ECOS Consulting 80PLUS Bronze Power Supply requirements. Redundant Power: Optional (1 1 or n n redundant) power supplies can be purchased through power supply option kits (see Redundant Options for part numbers). System Fans System Fans System Fans System Fans (3) Hot Plug fans ship standard (for full redundancy you can purchase the HP ML and DL 370G6 Redundant Fan Kit; PN: 508107-B231) Required Cabling Required Cabling Required Cabling Required Cabling For external storage cabling information, refer to the Web site at: www.hp.com/servers/dl370 or www.hp.com/servers/ml370 . OS Support OS Support OS Support OS Support Microsoft Windows Server Microsoft Windows Server Hyper V Red Hat Enterprise Linux (RHEL) SUSE Linux Enterprise Server (SLES) Oracle Enterprise Linux 5 (OEL) Solaris 10 for x86/x64 based Systems VMware Citrix Essentials for XenServer NOTE: NOTE: NOTE: NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/ossupport and our driver download page http://www.hp.com/support/ML370G6 . QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 15
Rack Airflow Rack Airflow Rack Airflow Rack Airflow Requirements Requirements Requirements Requirements Rack 10000 series Cabinets Rack 10000 series Cabinets Rack 10000 series Cabinets Rack 10000 series Cabinets The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. CAUTION: CAUTION: CAUTION: CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: Front and rear doors : If your 42U server rack includes closing front and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation). Side : The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm). CAUTION: CAUTION: CAUTION: CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. NOTE: NOTE: NOTE: NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: www.hp.com/servers/dl370 or www.hp.com/servers/ml370 . Telco Rack Support Telco Rack Support Telco Rack Support Telco Rack Support ProLiant rack mount servers and tower-to-rack kits include snap-on quick deploy side rails designed to accommodate both round and square hole rack rails. Telco rack solutions for ProLiant servers are available through the following URL: http://www.racksolutions.com/hp . Factory Express Portfolio Factory Express Portfolio Factory Express Portfolio Factory Express Portfolio for Servers and Storage for Servers and Storage for Servers and Storage for Servers and Storage HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to: http://www.hp.com/go/factory-express . HP Enterprise HP Enterprise HP Enterprise HP Enterprise Configurator Configurator Configurator Configurator The HP eConfigure-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. http://www.hp.com/products/configurator QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 16
Service and Support Service and Support Service and Support Service and Support HP Care Pack services provide total care and support expertise with committed response designed to meet your IT and business needs. HP Care Pack services include coverage for the HP branded hardware options qualified for the server and purchased at the same time or afterward that are internal to the enclosure. This also includes the 22" and smaller external monitors and tower UPS options up to 3kVA. These items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, and standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. To fully capitalizing on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions, provides a range of support services designed to meet the varying needs of your business. Whether an SMB, or large global corporation, HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime. Recommended Service Recommended Service Recommended Service Recommended Service - simplify ProLiant solution implementation, maintenance, and management. Support Support Support Support - 3-Year 4-Hour response 24x7 Same Business Day Coverage only Deployment Service Deployment Service Deployment Service Deployment Service - Installation and Start up only Enhanced Service Enhanced Service Enhanced Service Enhanced Service - optimize service level to increase IT performance and availability. Support Support Support Support - 3-Year Support Plus 24 only Refer to the information on "Installation & Start-Up" for service on ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet; to be delivered on a scheduled basis 8am-5pm, M-F, excluding HP holidays. NOTE: NOTE: NOTE: NOTE: For a complete listing of service offerings and information visit: http://www.hp.com/services/proliantservices http://www.hp.com/go/proliant/carepack QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 17
NOTE: NOTE: NOTE: NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. Tower Models Tower Models Tower Models Tower Models HP ML370 G6 Base HP ML370 G6 Base HP ML370 G6 Base HP ML370 G6 Base Model Model Model Model ML370 E5540 6GB ML370 E5540 6GB ML370 E5540 6GB ML370 E5540 6GB 487791-xx1 Processor(s) Processor(s) Processor(s) Processor(s) (1) Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Cache Memory Cache Memory Cache Memory Cache Memory 8MB (1 x 8MB) Level 3 cache Memory Memory Memory Memory 6 GB (3 x 2 GB) PC3-10600 (DDR3-1333) Registered DIMMs Network Controller Network Controller Network Controller Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Storage Controller Storage Controller Storage Controller Storage Controller HP Smart Array P410i/256MB Controller Hard Drive Hard Drive Hard Drive Hard Drive None ship standard Internal Storage Internal Storage Internal Storage Internal Storage (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) Optical Drive Optical Drive Optical Drive Optical Drive SATA DVD ROM PCI-Express Slots PCI-Express Slots PCI-Express Slots PCI-Express Slots 10 slots - (9) available PCI-e Gen2 slots ( NOTE: NOTE: NOTE: NOTE: 10 slots available, one is taken by the NIC riser card ) Power Supply Power Supply Power Supply Power Supply (1) 750W Hot Plug Power Supply Fans Fans Fans Fans (3) Hot Plug Fans Form Factor Form Factor Form Factor Form Factor 4U Tower HP ML370 G6 Entry HP ML370 G6 Entry HP ML370 G6 Entry HP ML370 G6 Entry Model Model Model Model ML370 E5520 4GB ML370 E5520 4GB ML370 E5520 4GB ML370 E5520 4GB 487795-xx1 Processor(s) Processor(s) Processor(s) Processor(s) (1) Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Cache Memory Cache Memory Cache Memory Cache Memory 8MB (1 x 8MB) Level 3 cache Memory Memory Memory Memory 4 GB (2 x 2 GB) PC3-10600E (DDR3-1333) Registered DIMMs Network Controller Network Controller Network Controller Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Storage Controller Storage Controller Storage Controller Storage Controller HP Smart Array P410i/256MB Controller Hard Drive Hard Drive Hard Drive Hard Drive None ship standard Internal Storage Internal Storage Internal Storage Internal Storage (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) Optical Drive Optical Drive Optical Drive Optical Drive SATA DVD ROM PCI-Express Slots PCI-Express Slots PCI-Express Slots PCI-Express Slots 10 slots - (9) available PCI-e Gen2 slots ( NOTE: NOTE: NOTE: NOTE: 10 slots available, one is taken by the NIC riser card ) Power Supply Power Supply Power Supply Power Supply (1) 460W Hot Plug Power Supply Fans Fans Fans Fans (3) Hot Plug Fans Form Factor Form Factor Form Factor Form Factor 4U Tower QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 18
Rack Models Rack Models Rack Models Rack Models HP DL370 G6 Base HP DL370 G6 Base HP DL370 G6 Base HP DL370 G6 Base Model Model Model Model DL370 E5530 6GB DL370 E5530 6GB DL370 E5530 6GB DL370 E5530 6GB 487794-xx1 Processor(s) Processor(s) Processor(s) Processor(s) (1) Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Cache Memory Cache Memory Cache Memory Cache Memory 8MB (1 x 8MB) Level 3 cache Memory Memory Memory Memory 6 GB (3 x 2 GB) PC3-10600 (DDR3-1333) Registered DIMMs Network Controller Network Controller Network Controller Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Storage Controller Storage Controller Storage Controller Storage Controller HP Smart Array P410i/256MB Controller Hard Drive Hard Drive Hard Drive Hard Drive None ship standard Internal Storage Internal Storage Internal Storage Internal Storage (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) Optical Drive Optical Drive Optical Drive Optical Drive SATA DVD ROM PCI-Express Slots PCI-Express Slots PCI-Express Slots PCI-Express Slots 10 slots - (9) available PCI-e Gen2 slots ( NOTE: NOTE: NOTE: NOTE: 10 slots available, one is taken by the NIC riser card ) Power Supply Power Supply Power Supply Power Supply (1) 750W Redundant Hot Plug Power Supply Fans Fans Fans Fans (3) Hot Plug Fans Form Factor Form Factor Form Factor Form Factor 4U Rack HP DL370 G6 HP DL370 G6 HP DL370 G6 HP DL370 G6 Performance Model Performance Model Performance Model Performance Model DL370 E5550 12GB DL370 E5550 12GB DL370 E5550 12GB DL370 E5550 12GB 487790-xx1 Processor(s) Processor(s) Processor(s) Processor(s) (2) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) Cache Memory Cache Memory Cache Memory Cache Memory 8MB (1 x 8MB) Level 3 cache Memory Memory Memory Memory 12 GB (6 x 2 GB) PC3-10600 (DDR3-1333) Registered DIMMs Network Controller Network Controller Network Controller Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Storage Controller Storage Controller Storage Controller Storage Controller HP Smart Array P410i/512MB with BBWC Hard Drive Hard Drive Hard Drive Hard Drive None ship standard Internal Storage Internal Storage Internal Storage Internal Storage (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) Optical Drive Optical Drive Optical Drive Optical Drive SATA DVD ROM PCI-Express Slots PCI-Express Slots PCI-Express Slots PCI-Express Slots 10 slots - (9) available PCI-e Gen2 slots ( NOTE: NOTE: NOTE: NOTE: 10 slots available, one is taken by the NIC riser card ) Power Supply Power Supply Power Supply Power Supply (2) 750W Redundant Hot Plug Power Supplies Fans Fans Fans Fans (5) Fully Redundant Hot Plug Fans Form Factor Form Factor Form Factor Form Factor 4U Rack QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 19
Country Code Key Country Code Key Country Code Key Country Code Key Tower Code Key Tower Code Key Tower Code Key Tower Code Key Rack Code Key Rack Code Key Rack Code Key Rack Code Key XX=00 U.S. English U.S. English XX=01 Australia N/A XX=03 UK N/A XX=04 Germany N/A XX=05 France N/A XX=20 Brazil Brazil XX=29 Japan Japan XX=37 APD APD XX=42 Europe Europe XX=AA PRC PRC QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 20
NOTE: NOTE: NOTE: NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements. NOTE: NOTE: NOTE: NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis. NOTE: NOTE: NOTE: NOTE: FIO indicates that this option only available as a Factory Installable Option. Step 1: Base Configuration (choose one of the following configurable models) Step 1: Base Configuration (choose one of the following configurable models) Step 1: Base Configuration (choose one of the following configurable models) Step 1: Base Configuration (choose one of the following configurable models) Models Models Models Models HP ProLiant ML370 G6 Tower Models HP ProLiant ML370 G6 Tower Models HP ProLiant ML370 G6 Tower Models HP ProLiant ML370 G6 Tower Models HP ProLiant ML370 G6 SFF CTO Chassis 483880-B21 NOTE: NOTE: NOTE: NOTE: Supports Small Form Factor (SFF) - 2.5" Drives Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Integrated Lights-Out embedded HP Smart Array P410i/Zero Memory Controller (8) Hot-Plug (SFF) SAS/SATA Drive Bays (9) available PCI-e Gen2 slots (5) USB ports (3) Hot Plug Fans Tower Form Factor HP ProLiant ML370 G6 LFF CTO Chassis 483879-B21 NOTE: NOTE: NOTE: NOTE: Supports Large Form Factor (LFF) - 3.5" Drives Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Integrated Lights-Out embedded HP Smart Array P410i/Zero Memory Controller (6) Hot-Plug (LFF) SAS/SATA Drive Bays (9) available PCI-e Gen2 slots (5) USB ports (3) Hot Plug Fans Tower Form Factor HP ProLiant DL370 G6 Rack Models HP ProLiant DL370 G6 Rack Models HP ProLiant DL370 G6 Rack Models HP ProLiant DL370 G6 Rack Models HP ProLiant DL370 G6 SFF CTO Chassis 483874-B21 NOTE: NOTE: NOTE: NOTE: Supports Small Form Factor (SFF) - 2.5" Drives Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Integrated Lights-Out embedded HP Smart Array P410i/Zero Memory Controller (8) Hot-Plug (SFF) SAS/SATA Drive Bays (9) available PCI-e Gen2 slots (5) USB ports (3) Hot Plug Fans 4U Rack Form Factor HP ProLiant DL370 G6 LFF CTO Chassis 483873-B21 NOTE: NOTE: NOTE: NOTE: Supports Large Form Factor (LFF) - 3.5" Drives Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Configuration Information - Factory Integrated Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 21
Integrated Lights-Out embedded HP Smart Array P410i/Zero Memory Controller (6) Hot-Plug (LFF) SAS/SATA Drive Bays (9) available PCI-e Gen2 slots (5) USB ports (3) Hot Plug Fans 4U Rack Form Factor Step 2: Choose Required Options (only one of the following from each list) Step 2: Choose Required Options (only one of the following from each list) Step 2: Choose Required Options (only one of the following from each list) Step 2: Choose Required Options (only one of the following from each list) Processors Processors Processors Processors NOTE: NOTE: NOTE: NOTE: If High Performance Model features are desired, 2nd processor is included in the Performance Pack part numbers in Step 3 below. Quad-Core Processors Quad-Core Processors Quad-Core Processors Quad-Core Processors Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO 495930-L21 Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO 495932-L21 Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO 495934-L21 Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO 495936-L21 Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO 495938-L21 Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO 495940-L21 Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO 495942-L21 Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO 495944-L21 Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO 505511-L21 Dual-Core Processors Dual-Core Processors Dual-Core Processors Dual-Core Processors Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO 495946-L21 Base Memory Base Memory Base Memory Base Memory Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) HP 2GB 2Rx8 PC3-10600R-9 Kit 500656-B21 HP 4GB 2Rx4 PC3-10600R-9 Kit 500658-B21 HP 4GB 4Rx8 PC3-8500R-7 LP Kit 500660-B21 HP 8GB 2Rx4 PC3-8500R-7 Kit 516423-B21 Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) HP 1GB 1Rx8 PC3-10600E-9 Kit 500668-B21 HP 2GB 2Rx8 PC3-10600E-9 Kit 500670-B21 NOTE: NOTE: NOTE: NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator . NOTE: NOTE: NOTE: NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/ Power Supply Power Supply Power Supply Power Supply NOTE: NOTE: NOTE: NOTE: Refer to HP Power Advisor when selecting a power supply for your QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Configuration Information - Factory Integrated Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 22
configuration, www.hp.co/go/hppoweradvisor . Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at " www.hp.com/go/proliant-energy-efficient " or www.hp.com/go/hppoweradvisor HP 460W CS HE Power Supply Kit 503296-B21 HP 750W CS HE Power Supply Kit 512327-B21 HP 1200W CS HE Power Supply Kit 500172-B21 NOTE: NOTE: NOTE: NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. Step 3: Choose Additional Factory Integratable Options Step 3: Choose Additional Factory Integratable Options Step 3: Choose Additional Factory Integratable Options Step 3: Choose Additional Factory Integratable Options Controllers Controllers Controllers Controllers NOTE: NOTE: NOTE: NOTE: If Additional Memory Cache Module or Controller is Required please pick one of the following: HP 256 MB P-series cache module FIO NOTE: NOTE: NOTE: NOTE: Available for P410i only. 534108-B21 512MB BBWC 462967-B21 HP Smart Array P212/256 MB w/ Battery FIO 491191-B21 HP Smart Array P410/256 MB w/ Battery FIO 491195-B21 HP Smart Array P411/256 MB w/ Battery FIO 491193-B21 Integrated hypervisor Integrated hypervisor Integrated hypervisor Integrated hypervisor (iHV) NOTE: NOTE: NOTE: NOTE: HP VMware ESXi free download from www.software.hp.com - select Virtualization HP VMware 3i Enterprise 2p Lic SW NOTE: NOTE: NOTE: NOTE: For additional information and options kits, please see the QuickSpecs at: www.hp.com/go/vmware . NOTE: NOTE: NOTE: NOTE: HP XenServer Select Edition free download from: http://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do? productNumber=HPXS 430341-B21 HP Essentials -XenServer Platinum Nm Lic 530753-B21 HP ProLiant Virtual Console Full License 508293-B21 XenServer HP Ent Upg iSW Lic 464676-B21 Citrix Essentials for XenServer Enterprise Edition NOTE: NOTE: NOTE: NOTE: For additional information and options kits, please see the Citrix Essentials for XenServer QuickSpecs at www.hp.com/go/citrix 508294-B21 Performance Packs Performance Packs Performance Packs Performance Packs Performance Packs are necessary to configure a HP ProLiant DL370 G6 or a HP ProLiant ML370 G6 to a High Performance Model which includes the latest performance technologies and enterprise class availability features pre-installed for convenience and value. The Performance Pack includes a 2nd processor, redundant fans, power supply, and memory expansion board. NOTE: NOTE: NOTE: NOTE: Must also select 447326-B21 to achieve parity to DL370 G6 or ML370 G6 High Performance Models. HP DL370 G6 and ML370 G6 X5550 HPM FIO Perf Kit 516727-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Configuration Information - Factory Integrated Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 23
Step 4: Choose Additional Options for Factory Integration Step 4: Choose Additional Options for Factory Integration Step 4: Choose Additional Options for Factory Integration Step 4: Choose Additional Options for Factory Integration NOTE: NOTE: NOTE: NOTE: For additional options, please refer to the "Core Options" and "Additional Options" section below. QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Configuration Information - Factory Integrated Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 24
NOTE: NOTE: NOTE: NOTE: Some options may not be factory configurable. Please contact your local sales representative for additional information. HP ProLiant ML370 and HP ProLiant ML370 and HP ProLiant ML370 and HP ProLiant ML370 and DL370 G6 Unique DL370 G6 Unique DL370 G6 Unique DL370 G6 Unique Options Options Options Options (8) Small Form Factor (SFF) 2nd Drive Cage Kit 507803-B21 (6) Large Form Factor (LFF) Backplane Kit 507810-B21 (2) Large Form Factor (LFF) Drive Cage Kit 487936-B21 HP ML370 G6 Tower to Rack Conversion Kit 515031-B21 HP ML and DL 370G6 Redundant Fan Kit 508107-B21 Processors Processors Processors Processors Quad-Core Processors Quad-Core Processors Quad-Core Processors Quad-Core Processors Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) 495930-B21 Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) 495932-B21 Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) 495934-B21 Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) 495936-B21 Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) 495938-B21 Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) 495940-B21 Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) 495942-B21 Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) 495944-B21 Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) 505511-B21 Dual-Core Processors Dual-Core Processors Dual-Core Processors Dual-Core Processors Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) 495946-B21 Memory Memory Memory Memory Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) HP 2GB 2Rx8 PC3-10600R-9 Kit 500656-B21 HP 4GB 2Rx4 PC3-10600R-9 Kit 500658-B21 HP 4GB 4Rx8 PC3-8500R-7 LP Kit 500660-B21 HP 8GB 2Rx4 PC3-8500R-7 Kit 516423-B21 Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) HP 1GB 1Rx8 PC3-10600E-9 Kit 500668-B21 HP 2GB 2Rx8 PC3-10600E-9 Kit 500670-B21 NOTE: NOTE: NOTE: NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator NOTE: NOTE: NOTE: NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/ QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Core Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 25
Optical Drives Optical Drives Optical Drives Optical Drives HP Half-Height SATA DVD-ROM Optical Drive 447326-B21 HP Half-Height SATA DVD RW Optical Drive 447328-B21 HP Slim SATA DVD RW Optical Drive 481043-B21 HP Slim SATA DVD-ROM Optical Drive 481041-B21 Hard Drives Hard Drives Hard Drives Hard Drives NOTE: NOTE: NOTE: NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details. SAS Hot Plug SFF Enterprise (ENT) Drives SAS Hot Plug SFF Enterprise (ENT) Drives SAS Hot Plug SFF Enterprise (ENT) Drives SAS Hot Plug SFF Enterprise (ENT) Drives NOTE: NOTE: NOTE: NOTE: Please note that SFF 2.5" (small form factor) drives can only be installed on tower or rack models with SFF chassis (models). HP 300GB 6G SAS 10K SFF DP ENT HDD 507127-B21 HP 300GB 3G SAS 10K SFF DP ENT HDD 492620-B21 HP 146GB 6G SAS 10K SFF DP ENT HDD 507125-B21 HP 146GB 3G SAS 10K SFF DP ENT HDD 418367-B21 HP 146GB 3G SAS 15K SFF DP ENT HDD 504062-B21 HP 72GB 3G SAS 15K SFF DP ENT HDD 418371-B21 HP 72GB 3G SAS 10K SFF DP ENT HDD 384842-B21 HP 36GB 3G SAS 15K SFF DP ENT HDD 418369-B21 NOTE: NOTE: NOTE: NOTE: SAS Enterprise drives have a 3 year warranty. Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.html (Worldwide) SAS Hot Plug 3.5" Enterprise (ENT) Drives SAS Hot Plug 3.5" Enterprise (ENT) Drives SAS Hot Plug 3.5" Enterprise (ENT) Drives SAS Hot Plug 3.5" Enterprise (ENT) Drives HP 450GB 3G SAS 15K 3.5" DP ENT HDD 454232-B21 HP 400GB 3G SAS 10K 3.5" DP ENT HDD 459508-B21 HP 146GB 3G SAS 15K 3.5" DP ENT HDD 384854-B21 HP 72GB 3G SAS 15K 3.5" DP ENT HDD 384852-B21 SAS Hot Plug 3.5" Midline (MDL) Drives SAS Hot Plug 3.5" Midline (MDL) Drives SAS Hot Plug 3.5" Midline (MDL) Drives SAS Hot Plug 3.5" Midline (MDL) Drives NOTE: NOTE: NOTE: NOTE: Please note that LFF 3.5" (large form factor) drives can only be installed on tower or rack models with LFF chassis (models). HP 1TB 3G SAS 7.2K DP MDL HDD 461137-B21 HP 750GB 3G SAS 7.2K DP MDL HDD 461135-B21 SATA Hot Plug SFF Entry (ETY) Drives SATA Hot Plug SFF Entry (ETY) Drives SATA Hot Plug SFF Entry (ETY) Drives SATA Hot Plug SFF Entry (ETY) Drives NOTE: NOTE: NOTE: NOTE: Please note that SFF 2.5" (small form factor) drives can only be installed on tower or rack models with SFF chassis (models). HP 250GB 3G SATA 5.4K SFF ETY HDD 460355-B21 HP 120GB 1.5G SATA 5.4K SFF ETY HDD 458924-B21 NOTE: NOTE: NOTE: NOTE: SATA hard drives have a 1-year warranty. Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html (Worldwide) SATA Hot Plug 3.5" Midline (MDL) Drives SATA Hot Plug 3.5" Midline (MDL) Drives SATA Hot Plug 3.5" Midline (MDL) Drives SATA Hot Plug 3.5" Midline (MDL) Drives HP 1TB 3G SATA 7.2K 3.5" MDL HDD 454146-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Core Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 26
HP 750GB 3G SATA 7.2K 3.5" MDL HDD 458930-B21 HP 500GB 3G SATA 7.2K 3.5" MDL HDD 458928-B21 HP 250GB 3G SATA 7.2K 3.5" MDL HDD 458926-B21 NOTE: NOTE: NOTE: NOTE: SATA hard drives have a 1-year warranty. Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html (Worldwide) Communications Communications Communications Communications HP NC112T PCIe Gigabit Server Adapter 503746-B21 HP NC360T PCI Express Dual Port Gigabit Server Adapter 412648-B21 HP NC364T PCI Express Quad Port Gigabit Server Adapter NOTE: NOTE: NOTE: NOTE: There is a maximum of five NC364T PCI Express Quad Port Gigabit Server Adapters allowed in this server. 435508-B21 HP NC373F PCI Express Multifunction Gigabit Server Adapter 394793-B21 HP NC373T PCI Express Multifunction Gigabit Server Adapter 394791-B21 HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter 458492-B21 HP NC522SFP Dual Port 10GbE Server Adapter NOTE: NOTE: NOTE: NOTE: A minimum of two gigabyte (2 GB) of server memory is required per each NC522SFP adapter. 468332-B21 HP NC524SFP Dual Port 10GbE Module 489892-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs . Redundant Options Redundant Options Redundant Options Redundant Options CAUTION: CAUTION: CAUTION: CAUTION: Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at www.hp.com/go/proliant-energy- efficient . In ProLiant Servers that have more than one power slot (bay), only same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail. HP 460W CS HE Power Supply Kit 503296-B21 HP 750W CS HE Power Supply Kit 512327-B21 HP 1200W CS HE Power Supply Kit 500172-B21 NOTE: NOTE: NOTE: NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. HP ML and DL 370G6 Redundant Fan Kit 508107-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Core Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 27
HP Insight Control Suite HP Insight Control Suite HP Insight Control Suite HP Insight Control Suite NOTE: NOTE: NOTE: NOTE: Electronic licensing options are available for Insight Control suites software products. Please see the appropriate Insight Control QuickSpecs for additional information. www.hp.com/go/ice HP Insight Control suite HP Insight Control suite HP Insight Control suite HP Insight Control suite HP Insight Control suite, No Media 1-Server License including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This part number can be purchased as a single license or as multiple licenses with a single activation key. Customer will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. Only available directly from HP and select resellers in the Americas region. 452148-B22 HP Insight Software Media Kit NOTE: NOTE: NOTE: NOTE: Insight Software DVD media without licenses. Contains Insight Manager and Insight Software products and components licensed by Insight Control suite. Uses an integrated installer to perform quick and accurate software installation and updates. 436222-B21 NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12631_div/12631_div.html HP Insight Control Linux Edition HP Insight Control Linux Edition HP Insight Control Linux Edition HP Insight Control Linux Edition HP Insight Control Environment for Linux, Media pack (DVD) - No licenses included NOTE: NOTE: NOTE: NOTE: This optional Media pack DVD contains the ISO image for HP Insight Control Environment for Linux, HP System Insight Manager, HP Insight Power Manager, HP Virtual Machine Management Pack, and an integrated installer. Servers must be acquired separately. NOTE: NOTE: NOTE: NOTE: This Media pack is optional because the latest ISO image and latest updates may be downloaded at no cost from: http://www.hp.com/go/ice-linux (click on Download button). 464422-B22 HP Insight Control Environment for Linux, No Media, 1-Server license, including one year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This part number can be used to purchase one (1) license with a single activation key. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: NOTE: NOTE: NOTE: One certificate is shipped for each license. 464423-B22 NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_div/13019_div.html Server Management Server Management Server Management Server Management Stand Alone Software Stand Alone Software Stand Alone Software Stand Alone Software NOTE: NOTE: NOTE: NOTE: Electronic licensing options are available for select software products. Please see the appropriate Insight Software standalone product QuickSpecs for additional information. Deploy Deploy Deploy Deploy HP Insight Rapid Deployment software HP Insight Rapid Deployment software HP Insight Rapid Deployment software HP Insight Rapid Deployment software HP Insight Rapid Deployment software No Media 1-Server License including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This license allows 1 server to be deployed and managed via RDP. Customer will receive a printed license entitlement certificate via physical shipment. The license 452151-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 28
entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html HP Insight Server Migration software for ProLiant HP Insight Server Migration software for ProLiant HP Insight Server Migration software for ProLiant HP Insight Server Migration software for ProLiant HP Insight Server Migration software for ProLiant, No Media, Physical / Virtual to ProLiant Single Migration License, including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This license allows 1 physical to ProLiant or virtual to ProLiant migration. Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. 460750-B21 HP Insight Server Migration software for ProLiant, No Media, Physical / Virtual to Virtual Single Migration License, including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This license allows 1 physical to virtual or virtual to virtual migration. Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. 460753-B21 HP Insight Server Migration software for ProLiant, No Media, 1-Year Unlimited Migration License, including 1 year of 24x7 Technical Support NOTE: NOTE: NOTE: NOTE: This license allows unlimited migrations (physical to ProLiant, physical to virtual, virtual to virtual, and virtual to ProLiant) for one year. Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. 460756-B21 NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12855_div/12855_div.html Monitor Monitor Monitor Monitor HP Insight Dynamics-VSE suite for ProLiant HP Insight Dynamics-VSE suite for ProLiant HP Insight Dynamics-VSE suite for ProLiant HP Insight Dynamics-VSE suite for ProLiant HP Insight Dynamics-VSE with Insight Control Environment, 1-server license including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This license supports HP ProLiant ML/DL and c-Class Blade servers. Customer will receive a printed license entitlement certificate via physical shipment. 483527-B21 HP Insight Dynamics-VSE without Insight Control Environment, 1-server license including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This license supports HP ProLiant ML/DL and c-Class Blade servers. Customer will receive via email a receipt and link to a license entitlement certificate. 483531-B21 NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13050_div/13050_div.html Control Control Control Control HP Integrated Lights-Out Select Pack HP Integrated Lights-Out Select Pack HP Integrated Lights-Out Select Pack HP Integrated Lights-Out Select Pack HP Integrated Lights-Out Select Pack, No Media, 1-Server License NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_div/12362_div.html 452158-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 29
HP Integrated Lights-Out Advanced Pack HP Integrated Lights-Out Advanced Pack HP Integrated Lights-Out Advanced Pack HP Integrated Lights-Out Advanced Pack HP Integrated Lights-Out Advanced Pack, No Media, 1-Server License, including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_div/12362_div.html 512485-B21 Optimize Optimize Optimize Optimize HP Accelerated iSCSI Pack HP Accelerated iSCSI Pack HP Accelerated iSCSI Pack HP Accelerated iSCSI Pack HP Accelerated iSCSI Pack, No Media, Single License NOTE: NOTE: NOTE: NOTE: For use with a single NIC port. Contains one license with a unique license activation key and documentation. NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12466_div/12466_div.html 452679-B21 HP Insight Power Manager (IPM) HP Insight Power Manager (IPM) HP Insight Power Manager (IPM) HP Insight Power Manager (IPM) HP Insight Power Manager software, No Media, 1-Server License, including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: Customers purchasing this upgrade must already have an iLO Advanced or Select license on each managed server. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12623_div/12623_div.html 452677-B21 NOTE: NOTE: NOTE: NOTE: Flexible and volume quantity license kits are available for Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various QuickSpecs for more information. Drive Cage Options Drive Cage Options Drive Cage Options Drive Cage Options (8) Small Form Factor (SFF) 2nd Drive Cage Kit 507803-B21 (6) Large Form Factor (LFF) Backplane Kit 507810-B21 (2) Large Form Factor (LFF) Drive Cage Kit 487936-B21 Security Security Security Security HP Trusted Platform Module Option Kit 488069-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 30
Storage Controllers Storage Controllers Storage Controllers Storage Controllers SAS Controllers SAS Controllers SAS Controllers SAS Controllers Smart Array P800 Controller Smart Array P800 Controller Smart Array P800 Controller Smart Array P800 Controller HP Smart Array P800/512 BBWC Controller 381513-B21 Smart Array P212 Controller Smart Array P212 Controller Smart Array P212 Controller Smart Array P212 Controller HP Smart Array P212/ZM Controller 462828-B21 HP Smart Array P212/256 MB Controller 462834-B21 256 MB Cache 462968-B21 Smart Array P410 Controller Smart Array P410 Controller Smart Array P410 Controller Smart Array P410 Controller HP Smart Array P410/256 MB Controller 462862-B21 HP Smart Array P410/512 MB with BBWC Controller 462864-B21 512MB BBWC 462967-B21 Smart Array P411 Controller Smart Array P411 Controller Smart Array P411 Controller Smart Array P411 Controller HP Smart Array P411/256 MB Controller 462830-B21 HP Smart Array P411/512 MB with BBWC Controller 462832-B21 512MB BBWC 462967-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12616_div/12616_div.html (Smart Array P800 Controller) http://h18000.www1.hp.com/products/quickspecs/13203_div/13203_div.html (Smart Array P212 Controller) http://h18000.www1.hp.com/products/quickspecs/13201_div/13201_div.html (Smart Array P410 Controller) http://h18000.www1.hp.com/products/quickspecs/13202_div/13202_div.html (Smart Array P411 Controller) SAS Controller Options SAS Controller Options SAS Controller Options SAS Controller Options HP SAS Expander Card NOTE: NOTE: NOTE: NOTE: For use with the additional 8 SFF drive cage (507803-B21). 468406-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/13232_div/13232_div.html (SAS Expander Card) SAS HBA SAS HBA SAS HBA SAS HBA HP SC08Ge Host Bus Adapter 488765-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/13082_div/13082_div.html (SC08Ge HBA) QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 31
Power Cords Power Cords Power Cords Power Cords NOTE: NOTE: NOTE: NOTE: HP ProLiant servers ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). Nema 5-15P to IEC320-C13, North America low voltage (6 ft/2 m) AF556A Power Cord, Euro, 10A 250 V Straight (6 ft/1.83 m) AF568A Power Cord, UK, 10A 250 V Straight (6 ft/1.83 m) AF570A Power Cord, Danish, 10A 250 V Straight (6 ft/1.83 m) AF566A Power Cord, Swiss, 10A 250 V Straight (6 ft/1.83 m) AF565A Power Cord, Italian, 10A 250 V Straight (6 ft/1.83 m) AF571A Power Cord, South Africa, 10A 250 V Straight (8.2 ft/2.5 m) AF567A Tape Drives Tape Drives Tape Drives Tape Drives NOTE: NOTE: NOTE: NOTE: For the complete listing of Tape Drive offerings, please see: http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html For recommended tape drive offerings for this ProLiant server see the following: USB Tape Drives USB Tape Drives USB Tape Drives USB Tape Drives HP StorageWorks DAT 160 USB Internal Tape Drive Q1580A SAS Tape Drives SAS Tape Drives SAS Tape Drives SAS Tape Drives NOTE: NOTE: NOTE: NOTE: For the ML370 G6, HP recommends purchasing the HP Smart Array P212 Controller (462828-B21) for a dedicated SAS HBA for tape. HP StorageWorks LTO-2 Ultrium 448 SAS Internal Tape Drive DW085A HP StorageWorks LTO-3 Ultrium 920 SAS Internal Tape Drive EH847A HP StorageWorks LTO-4 Ultrium 1760 SAS Internal Tape Drive EH919A NOTE: NOTE: NOTE: NOTE: Please refer to the "Tape Drives, Tape Autoloaders & Tape Libraries" table in the Storage section of this document for a list of SAS controllers with tape support. Disk-Based Backup Disk-Based Backup Disk-Based Backup Disk-Based Backup RDX Removable Disk Backup RDX Removable Disk Backup RDX Removable Disk Backup RDX Removable Disk Backup HP StorageWorks RDX500 Internal Removable Disk Backup System NOTE: NOTE: NOTE: NOTE: 500GB of Disk Storage. AJ934A D2D Backup D2D Backup D2D Backup D2D Backup HP StorageWorks D2D120 Backup System with Data Protector Express Software Kit NOTE: NOTE: NOTE: NOTE: 2TB of Disk Storage EH924A HP StorageWorks D2D130 Backup System with LTO-3 Ultrium 920 SAS Tape Drive NOTE: NOTE: NOTE: NOTE: 3TB of Disk Storage. EH952A HP StorageWorks D2D2503i Backup System NOTE: NOTE: NOTE: NOTE: 3TB of Disk Storage. EH945A HP StorageWorks D2D4004i Backup System NOTE: NOTE: NOTE: NOTE: 4.5TB of Disk Storage. EH938A NOTE: NOTE: NOTE: NOTE: Please see the HP D2D Backup Systems QuickSpecs for additional information: http://www.hp.com/go/d2d QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 32
Tape Autoloaders Tape Autoloaders Tape Autoloaders Tape Autoloaders HP StorageWorks 1/8 G2 Tape Autoloader HP StorageWorks 1/8 G2 Tape Autoloader HP StorageWorks 1/8 G2 Tape Autoloader HP StorageWorks 1/8 G2 Tape Autoloader HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader AK377A HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader AH558A HP StorageWorks 1/8 G2 Tape Autoloader Rack Kit NOTE: NOTE: NOTE: NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions. AH166A NOTE: NOTE: NOTE: NOTE: Please reference the Tape Autoloader QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs Tape Libraries Tape Libraries Tape Libraries Tape Libraries HP StorageWorks MSL2024 Tape Library HP StorageWorks MSL2024 Tape Library HP StorageWorks MSL2024 Tape Library HP StorageWorks MSL2024 Tape Library HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Drive Library AK378A HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SAS Drive Library AH559A HP StorageWorks MSL4048 Tape Library HP StorageWorks MSL4048 Tape Library HP StorageWorks MSL4048 Tape Library HP StorageWorks MSL4048 Tape Library HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SAS Drive Library AK380A HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SAS Drive Library AH560A NOTE: NOTE: NOTE: NOTE: Please reference the MSL Tape Library QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs . High Availability Cluster High Availability Cluster High Availability Cluster High Availability Cluster Options Options Options Options HP Serviceguard for Linux HP Serviceguard for Linux HP Serviceguard for Linux HP Serviceguard for Linux HP Serviceguard Linux for HP ProLiant/x86 Servers Licensed per physical server Includes media and One Year 24x7 Software Support & Updates 463831-B21 HP Serviceguard Linux Oracle Database Toolkit for HP ProLiant/x86 Servers Licensed per cluster Includes media and One Year 24x7 Software Support & Updates 463833-B21 HP Serviceguard Extension for SAP on Linux for HP ProLiant/x86 Servers Licensed per physical server Includes media and One Year 24x7 Software Support & Updates 463834-B21 HP Serviceguard Linux Extended Distance Cluster (XDC) for HP ProLiant/x86 Servers Licensed per physical server Includes media and One Year 24x7 Software Support & Updates 463835-B21 NOTE: NOTE: NOTE: NOTE: The above is not a complete list of all HP Serviceguard for Linux product numbers For a detailed list of supported configuration/certification options for HP Serviceguard for Linux please refer to the HP Serviceguard for Linux Configuration & Ordering Guide available at: http://www.hp.com/go/sglx/info . NOTE: NOTE: NOTE: NOTE: HP Serviceguard for Linux products running on x86 platforms now include one year of 24 x 7 Software Technical Support and Updates. Please see the Support Information section of the HP Serviceguard for Linux QuickSpecs for details. NOTE: NOTE: NOTE: NOTE: For additional information including a complete list of Product Numbers for HP Serviceguard for Linux, please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html (Worldwide) QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 33
StorageWorks Options StorageWorks Options StorageWorks Options StorageWorks Options StorageWorks Fibre Channel HBA StorageWorks Fibre Channel HBA StorageWorks Fibre Channel HBA StorageWorks Fibre Channel HBA NOTE: NOTE: NOTE: NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html HP StorageWorks FC2142SR 4Gb PCI-e HBA A8002A HP StorageWorks FC2242SR Dual Channel 4Gb PCI-e HBA A8003A HP StorageWorks FC1142SR 4Gb PCI-e HBA AE311A HP StorageWorks FC1242SR Dual Channel 4Gb PCI-e HBA AE312A HP StorageWorks 81Q PCI-e FC HBA AK344A HP StorageWorks 81E 8Gb PCI-e FC HBA AJ762A HP StorageWorks 82E 8Gb Dual-port PCI-e FC HBA AJ763A HP StorageWorks 82Q 8Gb Dual Port PCI-e FC HBA AJ764A StorageWorks SCSI HBA StorageWorks SCSI HBA StorageWorks SCSI HBA StorageWorks SCSI HBA HP U320e SCSI Host Bus Adapter NOTE: NOTE: NOTE: NOTE: Recommended Dual Channel Ultra320 SCSI Controller for connecting multi- drive MSL tape libraries to ProLiant servers. AH627A HP StorageWorks 50 HP StorageWorks 50 HP StorageWorks 50 HP StorageWorks 50 Modular Smart Array Modular Smart Array Modular Smart Array Modular Smart Array HP StorageWorks 50 Modular Smart Array 364430-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12245_div/12245_div.html (Worldwide) HP StorageWorks 60 HP StorageWorks 60 HP StorageWorks 60 HP StorageWorks 60 Modular Smart Array Modular Smart Array Modular Smart Array Modular Smart Array HP StorageWorks 60 Modular Smart Array 418408-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12627_div/12627_div.html (Worldwide) HP StorageWorks 70 HP StorageWorks 70 HP StorageWorks 70 HP StorageWorks 70 Modular Smart Array Modular Smart Array Modular Smart Array Modular Smart Array HP StorageWorks 70 Modular Smart Array 418800-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12652_div/12652_div.html (Worldwide) QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 34
Uninterruptible Power Uninterruptible Power Uninterruptible Power Uninterruptible Power Systems - Tower Systems - Tower Systems - Tower Systems - Tower HP T1000v Uninterruptible Power System HP T1000v Uninterruptible Power System HP T1000v Uninterruptible Power System HP T1000v Uninterruptible Power System HP T1000v UPS NOTE: NOTE: NOTE: NOTE: The T1000v is available in China and India only. AF443A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13130_div/13130_div.html (Worldwide) HP T1500 G3 UPS Models HP T1500 G3 UPS Models HP T1500 G3 UPS Models HP T1500 G3 UPS Models HP T1500 G3 UPS, NA AF450A HP T1500 G3 UPS, INTL AF451A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13160_div/13160_div.html (Worldwide) Uninterruptible Power Uninterruptible Power Uninterruptible Power Uninterruptible Power Systems - Rack Systems - Rack Systems - Rack Systems - Rack HP R1500 G2 UPS HP R1500 G2 UPS HP R1500 G2 UPS HP R1500 G2 UPS HP, R1.5kVA UPS, 1U, NA AF419A HP, R1.5kVA UPS, 1U, INTL AF418A HP, R1.5kVA UPS, 1U, JPN/TW AF421A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12507_div/12507_div.html (Worldwide) HP R3000 UPS HP R3000 UPS HP R3000 UPS HP R3000 UPS HP R3000 VA UPS, 2U, DTC, INTL AF414A HP R3000 VA UPS, 2U, L5-30, NA AF422A HP R3000 VA UPS, 2U, L6-20, NA AF423A HP R3000 VA UPS, 2U, L6-20, JPN AF424A HP R3000 VA UPS, 2U, L5-30, JPN AF425A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/10671_div/10671_div.html (Worldwide) HP R3000v Uninterruptible Power System HP R3000v Uninterruptible Power System HP R3000v Uninterruptible Power System HP R3000v Uninterruptible Power System HP R3000v UPS NOTE: NOTE: NOTE: NOTE: The R3000v is available in China and India only. AF444A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13129_div/13129_div.html (Worldwide) HP Rack-Mountable R5500 UPS HP Rack-Mountable R5500 UPS HP Rack-Mountable R5500 UPS HP Rack-Mountable R5500 UPS HP R5500 VA UPS, INTL AF416A HP R5500 VA UPS, NA/JPN AF426A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/11871_div/11871_div.html (Worldwide) QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 35
HP Monitored Power HP Monitored Power HP Monitored Power HP Monitored Power Distribution Unit Distribution Unit Distribution Unit Distribution Unit (PDU) HP Monitored Power Distribution Unit: Full Rack Version HP Monitored Power Distribution Unit: Full Rack Version HP Monitored Power Distribution Unit: Full Rack Version HP Monitored Power Distribution Unit: Full Rack Version HP 17.3 kVA S2324 Monitored PDU- dual input, 3Ã24A (NA/JPN) AF503A HP 8.6 kVA S1324 Monitored PDU- single input, 3Ã, 24A (NA/JPN) AF504A HP 16.6 kVA S2140 Monitored PDU- dual input, 1Ã, 40A (NA/JPN) AF505A HP 8.3 S1140 Monitored PDU- single input, 1Ã, 40A (NA/JPN) AF506A HP 22.1 kVA S2316 Monitored PDU- dual input, 3Ã, 16A (INTL) AF507A HP 11 kVA S1316 Monitored PDU- single input, 3Ã, 16A (INTL) AF508A HP 14.7 kVA S2132 Monitored PDU- dual input, 1Ã, 32A (INTL) AF509A HP 7.3 kVA S1132 Monitored PDU- single input, 1Ã, 32A (INTL) AF510A HP Monitored Power Distribution Unit: Half Rack Version HP Monitored Power Distribution Unit: Half Rack Version HP Monitored Power Distribution Unit: Half Rack Version HP Monitored Power Distribution Unit: Half Rack Version HP 4.9 kVA S124 Monitored PDU- single input, 1Ã, 24A (NA/JPN) AF914A HP 7.3 kVA S132 Monitored PDU- single input, 1Ã, 32A (INTL) AF915A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12118_div/12118_div.html (Worldwide) Modular PDUs 1U/0U Modular PDUs 1U/0U Modular PDUs 1U/0U Modular PDUs 1U/0U (Up to 32 outlets) NOTE: NOTE: NOTE: NOTE: 1U/0U mounting brackets shipped with the unit (optimized for 10000 and 9000 series racks). Fixed Cord Extension Bars NOTE: NOTE: NOTE: NOTE: Two extension bar sticks; each with (7) C13 plugs. 351655-B21 3.6kVA Model - mPDU, 16A, High (WW) 252663-B24 2.8 kVA Model - mPDU, 24A, Low (NA/JPN) 252663-D71 4.9kVA Model - mPDU, 24A, High (NA/JPN) 252663-D72 7.3kVA Model - mPDU, 32A, High (INT'L) 252663-B31 8.3kVA Model - mPDU, 40A, High (WW) 252663-B21 8.3kVA Model - mPDU, 40A, High (power cord attached) (NA/JPN) 252663-D73 9.2kVA Model - mPDU, 40A, High (power cord attached) (INTL) 252663-B32 NOTE: NOTE: NOTE: NOTE: For additional information on HP Power Distribution Units including accessories please go to: www.hp.com/go/pdu (Worldwide) USB Options USB Options USB Options USB Options HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) DC172B USB 1.44-MB External Diskette Drive (Carbonite) DC141B HP USB 04 Standard Keyboard DT528A#ABA Rack Kit Rack Kit Rack Kit Rack Kit HP ML370 G6 Tower to Rack Conversion Kit 515031-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 36
HP Rack 5000 Series HP Rack 5000 Series HP Rack 5000 Series HP Rack 5000 Series (Graphite Metallic) HP 5642 Rack Unassembled 358254-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12074_div/12074_div.html (Worldwide) NOTE: NOTE: NOTE: NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower . HP Rack 10000 G2 HP Rack 10000 G2 HP Rack 10000 G2 HP Rack 10000 G2 Series Series Series Series (Carbon/Graphite Metallic) 10642 G2 (42U) Rack Cabinet - Pallet AF001A 10642 G2 (42U) Rack Cabinet - Shock Pallet AF002A 10642 G2 (42U) Rack Cabinet - Crated AF003A 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet AF004A 10636 G2 (36U) Rack Cabinet - Pallet AF011A 10636 G2 (36U) Rack Cabinet - Shock Pallet AF012A 10636 G2 (36U) Rack Cabinet - Crated AF013A 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet AF014A 10622 G2 (22U) Rack Cabinet - Pallet AF021A 10622 G2 (22U) Rack Cabinet - Shock Pallet AF022A 10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock Pallet AF034A 10642 G2 (42U) Rack Cabinet 1200mm Deep - Pallet AF038A 10842 G2 (42U) 800mm Wide Rack Cabinet - Pallet AF041A 10842 G2 (42U) 800mm Wide Rack Cabinet - Shock Pallet AF042A 10647 G2 (47U) Rack Cabinet - Pallet AF031A HP Rack S10614 (14U) Rack Cabinet - Shock Pallet 292302-B22 10647 G2 (47U) Rack Cabinet 1200mm Deep - Shock Pallet NOTE: NOTE: NOTE: NOTE: Due to handling and shipping requirements, AF044A is only orderable through HP Factory Express. It is not for direct sales. Customer site surveys are required before an order is approved. CTO orders may require additional lead time. AF044A 10647 G2 (47U) Rack Cabinet 1200mm Deep - Pallet AF045A NOTE: NOTE: NOTE: NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed. NOTE: NOTE: NOTE: NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html (Worldwide) NOTE: NOTE: NOTE: NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower . QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 37
Keyboards and Monitors Keyboards and Monitors Keyboards and Monitors Keyboards and Monitors TFT7600 Rackmount Keyboard Monitor US AG052A TFT7600 Rackmount Keyboard Monitor UK AG053A TFT7600 Rackmount Keyboard Monitor GR AG054A TFT7600 Rackmount Keyboard Monitor FR AG055A TFT7600 Rackmount Keyboard Monitor IT AG056A TFT7600 Rackmount Keyboard Monitor SP AG057A TFT7600 Rackmount Keyboard Monitor DEN AG058A TFT7600 Rackmount Keyboard Monitor NOR AG059A TFT7600 Rackmount Keyboard Monitor SE/FI AG060A TFT7600 Rackmount Keyboard Monitor SWI AG061A TFT7600 Rackmount Keyboard Monitor PORT AG062A TFT7600 Rackmount Keyboard Monitor BEL AG063A TFT7600 Rackmount Keyboard Monitor JPN2 AG064A TFT7600 Rackmount Keyboard Monitor RUS AG065A TFT7600 Rackmount Keyboard Monitor INTL AG066A 1U Rackmount Keyboard with USB, US AG072A 1U Rackmount Keyboard with USB, UK AG073A 1U Rackmount Keyboard with USB, GR AG074A 1U Rackmount Keyboard with USB, FR AG075A 1U Rackmount Keyboard with USB, ITL AG076A 1U Rackmount Keyboard with USB, SP AG077A 1U Rackmount Keyboard with USB, DEN AG078A 1U Rackmount Keyboard with USB, NOR AG079A 1U Rackmount Keyboard with USB, SE/FI AG080A 1U Rackmount Keyboard with USB, SWI AG081A 1U Rackmount Keyboard with USB, PORT AG082A 1U Rackmount Keyboard with USB, BEL AG083A 1U Rackmount Keyboard with USB, JPN2 AG084A 1U Rackmount Keyboard with USB, RUS AG085A 1U Rackmount Keyboard with USB, INTL AG086A NOTE: NOTE: NOTE: NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower . QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 38
HP KVM Switch Options HP KVM Switch Options HP KVM Switch Options HP KVM Switch Options 2x1x16 IP Console Switch with Virtual Media AF601A 4x1x16 IP Console Switch with Virtual Media AF602A 2x16 Server Console Switch with Virtual Media AF600A PS/2 Virtual Media Interface Adapter, 1 pack NOTE: NOTE: NOTE: NOTE: Requires PS/2 and one USB port on server. AF604A Server Console Switch (KVM), 0 x 1 x 8 port 336044-B21 Server Console Switch (KVM), 0 x 2 x 16 port 336045-B21 PS/2 Interface Adapter, 1 pack 262588-B21 PS/2 Interface Adapter, 8 pack 262587-B21 NOTE: NOTE: NOTE: NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm . HP 1x4 Console Switch (ALL) AF611A PS2 Server Console Cable, 6 ft, 2 pack AF612A USB Server Console Cable, 6 ft, 2 pack AF613A NOTE: NOTE: NOTE: NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm . HP Serial Console Server HP Serial Console Server HP Serial Console Server HP Serial Console Server Options Options Options Options HP 16 Port Serial Console Server (worldwide) AF101A HP 48 Port Serial Console Server (worldwide) AF102A Serial Adapter, RJ45-DB9 DCE Female, 1 Pack AF103A Serial Adapter, RJ45-DB9 DCE Female, 8 Pack AF110A NOTE: NOTE: NOTE: NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm . NOTE: NOTE: NOTE: NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm . QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 39
Service and Support Service and Support Service and Support Service and Support Offerings Offerings Offerings Offerings (HP Care Pack Services) Hardware Services On-site Service Hardware Services On-site Service Hardware Services On-site Service Hardware Services On-site Service 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic U4528E 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic U4529E Hardware Services 6-Hour Call to Repair On-site Service Hardware Services 6-Hour Call to Repair On-site Service Hardware Services 6-Hour Call to Repair On-site Service Hardware Services 6-Hour Call to Repair On-site Service 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic U4530E Installation & Start-up Services Installation & Start-up Services Installation & Start-up Services Installation & Start-up Services Hardware Installation, Electronic U4538E Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am- 5pm, M-F, excl. HP holidays, Electronic U4539E Support Plus Support Plus Support Plus Support Plus Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic U4540E Support Plus 24 Support Plus 24 Support Plus 24 Support Plus 24 Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic U4541E Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic U6311E Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic U8333E NOTE: NOTE: NOTE: NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack . QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 40
NOTE: NOTE: NOTE: NOTE: Memory configurations listed do not apply to "Factory Integrated Models". HP ProLiant DL370 G6 Models HP ProLiant DL370 G6 Models HP ProLiant DL370 G6 Models HP ProLiant DL370 G6 Models HP ProLiant ML370 G6 Models HP ProLiant ML370 G6 Models HP ProLiant ML370 G6 Models HP ProLiant ML370 G6 Models DDR3 memory population guidelines DDR3 memory population guidelines DDR3 memory population guidelines DDR3 memory population guidelines For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator Some DIMM installation guidelines are summarized below: For servers with eighteen (18) memory slots: There are three (3) channels per processor; six (6) channels per server There are three (3) DIMM slots for each memory channel; eighteen (18) total slots Memory channel 1 consists of the three (3) DIMMs that are closest to the processor Memory channel 3 consists of the three (3) DIMMs that are furthest from the processor DIMM slots that are white should be populated first Do not mix Unbuffered memory (UDIMMs) with Registered memory (RDIMMs) Do not install DIMMs if the corresponding processor is not installed If only one processor is installed in a 2CPU system, only half of the DIMM slots are available To maximize performance, balance the total memory capacity between all installed processors It is not required, but it is recommended to load the channels similarly if possible You can only have up to eight (8) ranks installed per channel You can only install two quad-rank DIMMs per channel You can only install two UDIMMs per channel; if available, the third slot in the channel must remain empty Populate DIMMs from heaviest load (quad-rank) to lightest load (single-rank) within a channel Heaviest load (DIMM with most ranks) within a channel goes furthest from the chipset For memory mirroring mode, channel 3 must be unpopulated. Channels 1 and 2 are populated identically For lock-step mode, channel 3 must be unpopulated. DIMMs in channels 1 and 2 will be installed in pairs. The paired slots will be 1,4; 2,5; 3;6 on a 3DPC system or 1,4; 2,5; on a 2DPC system No mixing DIMM voltage; all DIMMs must be the same voltage DIMM Type -> Registered Dimms (RDIMMs) Registered Dimms (RDIMMs) Registered Dimms (RDIMMs) Registered Dimms (RDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) DIMM Rank -> Dual Rank (2R) Dual Rank (2R) Dual Rank (2R) Dual Rank (2R) Quad Rank (4R) Quad Rank (4R) Quad Rank (4R) Quad Rank (4R) Single Rank (1R) Single Rank (1R) Single Rank (1R) Single Rank (1R) Dual Rank (2R) Dual Rank (2R) Dual Rank (2R) Dual Rank (2R) DIMM Capacity -> 2GB 4GB 8GB 2GB 4GB 1GB 2GB 1GB 2GB DIMM Native Speed (MHz) -> 1333 1333 1066 * 1066 1333 * * 1333 SLOTS THAT CAN BE POPULATED SLOTS THAT CAN BE POPULATED SLOTS THAT CAN BE POPULATED SLOTS THAT CAN BE POPULATED 18 slot servers 18 18 18 * 12 12 * * 12 MAXIMUM CAPACITY (GB) MAXIMUM CAPACITY (GB) MAXIMUM CAPACITY (GB) MAXIMUM CAPACITY (GB) 18 slot servers 36 72 144 * 48 12 * * 24 POPULATED DIMM SPEED (MHz) POPULATED DIMM SPEED (MHz) POPULATED DIMM SPEED (MHz) POPULATED DIMM SPEED (MHz) 1 DIMM Per Channel 1333 1333 1066 * 1066 1333 * * 1333 2 DIMM Per Channel 1066 1066 1066 * 800 1066 * * 1066 3 DIMM Per Channel 800 800 800 * * * * * * * not supported by HP at this time. NOTES: NOTES: NOTES: NOTES: QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Memory DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 41
Mixing DIMM speeds is allowed, but the system processor speed rules always override the DIMM capabilities If you do mix DIMM speeds, the memory bus will default to the minimum clock rate of all DIMMs in the system - even if the slower DIMM is on the other processor If you install 1x 1066MHz DIMM in channel 1 and 1x 1333MHz DIMM in channel 2, you still run at 1066MHz If you install 1x 1066MHz DIMM in channel 1 and 5x 1333MHz DIMMs with 1 DIMM Per Channel (DPC) in each of the other channels, you run at 1066MHz If you install 3DPC in one channel (if applicable) and 1DPC in all other channels, you run at 800MHz 95 Watt CPU's are required for 1333MHz DIMM speeds. All other CPU's are capable of up to 1066MHz References to the above MHz speeds are for the various speeds of DDR3 DIMMs; 1333 refers to DDR3-1333, etc. DIMM slot and configuration diagrams DIMM slot and configuration diagrams DIMM slot and configuration diagrams DIMM slot and configuration diagrams Basic memory slot & population diagram Basic memory slot & population diagram Basic memory slot & population diagram Basic memory slot & population diagram Population order; start with "A" first, "B" second, "C" third, etc. 18 DIMM SLOTS (9 per CPU node) 18 DIMM SLOTS (9 per CPU node) 18 DIMM SLOTS (9 per CPU node) 18 DIMM SLOTS (9 per CPU node) CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G 1 G Chnl 1 2 D 2 D 3 A 3 A Chnl 2 4 H 4 H Chnl 2 5 E 5 E 6 B 6 B Chnl 3 7 I 7 I Chnl 3 8 F 8 F 9 C 9 C Standard memory configuration (1 CPU model) Standard memory configuration (1 CPU model) Standard memory configuration (1 CPU model) Standard memory configuration (1 CPU model) 6GB, consisting of three (3) 2GB dual-rank PC3-10600 RDIMMs CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G; empty 1 G; empty Chnl 1 2 D; empty 2 D; empty 3 A; 2GB DIMM 3 A; empty Chnl 2 4 H; empty 4 H; empty Chnl 2 5 E; empty 5 E; empty 6 B; 2GB DIMM 6 B; empty Chnl 3 7 I; empty 7 I; empty Chnl 3 8 F; empty 8 F; empty 9 C; 2GB DIMM 9 C; empty QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Memory DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 42
Standard memory plus optional memory (1 CPU model) Standard memory plus optional memory (1 CPU model) Standard memory plus optional memory (1 CPU model) Standard memory plus optional memory (1 CPU model) 54GB, consisting of three (3) 2GB RDIMMs plus six (6) 8GB RDIMMs 3x 2GB dual-rank PC3-10600 RDIMMs 6x 8GB dual-rank PC3-8500 RDIMMs CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G; 8GB DIMM 1 G; empty Chnl 1 2 D; 8GB DIMM 2 D; empty 3 A; 2GB DIMM 3 A; empty Chnl 2 4 H; 8GB DIMM 4 H; empty Chnl 2 5 E; 8GB DIMM 5 E; empty 6 B; 2GB DIMM 6 B; empty Chnl 3 7 I; 8GB DIMM 7 I; empty Chnl 3 8 F; 8GB DIMM 8 F; empty 9 C; 2GB DIMM 9 C; empty Standard memory replaced with optional memory (1 CPU model) Standard memory replaced with optional memory (1 CPU model) Standard memory replaced with optional memory (1 CPU model) Standard memory replaced with optional memory (1 CPU model) RDIMM maximum configuration RDIMM maximum configuration RDIMM maximum configuration RDIMM maximum configuration 72GB, consisting of nine (9) 8GB dual-rank PC3-8500 RDIMMs CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G; 8GB DIMM 1 G; empty Chnl 1 2 D; 8GB DIMM 2 D; empty 3 A; 8GB DIMM 3 A; empty Chnl 2 4 H; 8GB DIMM 4 H; empty Chnl 2 5 E; 8GB DIMM 5 E; empty 6 B; 8GB DIMM 6 B; empty Chnl 3 7 I; 8GB DIMM 7 I; empty Chnl 3 8 F; 8GB DIMM 8 F; empty UDIMM maximum configuration (1 CPU model) UDIMM maximum configuration (1 CPU model) UDIMM maximum configuration (1 CPU model) UDIMM maximum configuration (1 CPU model) 12GB, consisting of six (6) 2GB dual-rank PC3-10600 UDIMMs QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Memory DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 43
CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G; empty 1 G; empty Chnl 1 2 D; 2GB DIMM 2 D; empty 3 A; 2GB DIMM 3 A; empty Chnl 2 4 H; empty 4 H; empty Chnl 2 5 E; 2GB DIMM 5 E; empty 6 B; 2GB DIMM 6 B; empty Chnl 3 7 I; empty 7 I; empty Chnl 3 8 F; 2GB DIMM 8 F; empty 9 C; 2GB DIMM 9 C; empty Standard memory replaced with optional memory (2 CPU model) Standard memory replaced with optional memory (2 CPU model) Standard memory replaced with optional memory (2 CPU model) Standard memory replaced with optional memory (2 CPU model) RDIMM maximum configuration RDIMM maximum configuration RDIMM maximum configuration RDIMM maximum configuration 144GB, consisting of eighteen (18) 8GB PC3-8500 RDIMMs CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G; 8GB DIMM 1 G; 8GB DIMM Chnl 1 2 D; 8GB DIMM 2 D; 8GB DIMM 3 A; 8GB DIMM 3 A; 8GB DIMM Chnl 2 4 H; 8GB DIMM 4 H; 8GB DIMM Chnl 2 5 E; 8GB DIMM 5 E; 8GB DIMM 6 B; 8GB DIMM 6 B; 8GB DIMM Chnl 3 7 I; 8GB DIMM 7 I; 8GB DIMM Chnl 3 8 F; 8GB DIMM 8 F; 8GB DIMM 9 C; 8GB DIMM 9 C; 8GB DIMM UDIMM maximum configuration (2 CPU model) UDIMM maximum configuration (2 CPU model) UDIMM maximum configuration (2 CPU model) UDIMM maximum configuration (2 CPU model) 24GB, consisting of twelve (12) 2GB dual-rank PC3-10600 UDIMMs QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Memory DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 44
CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G; empty 1 G; empty Chnl 1 2 D; 2GB DIMM 2 D; 2GB DIMM 3 A; 2GB DIMM 3 A; 2GB DIMM Chnl 2 4 H; empty 4 H; empty Chnl 2 5 E; 2GB DIMM 5 E; 2GB DIMM 6 B; 2GB DIMM 6 B; 2GB DIMM Chnl 3 7 I; empty 7 I; empty Chnl 3 8 F; 2GB DIMM 8 F; 2GB DIMM 9 C; 2GB DIMM 9 C; 2GB DIMM NOTE: NOTE: NOTE: NOTE: Capacity references are rounded to the common Gigabyte values. 1GB = 1024MB 2GB = 2048MB 4GB = 4096MB 8GB = 8192MB Following are memory options available from HP: Following are memory options available from HP: Following are memory options available from HP: Following are memory options available from HP: Memory Memory Memory Memory Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) HP 2GB 2Rx8 PC3-10600R-9 Kit 500656-B21 HP 4GB 2Rx4 PC3-10600R-9 Kit 500658-B21 HP 4GB 4Rx8 PC3-8500R-7 LP Kit 500660-B21 HP 8GB 2Rx4 PC3-8500R-7 Kit 516423-B21 Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) HP 1GB 1Rx8 PC3-10600E-9 Kit 500668-B21 HP 2GB 2Rx8 PC3-10600E-9 Kit 500670-B21 NOTE: NOTE: NOTE: NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator . NOTE: NOTE: NOTE: NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/ QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Memory DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 45
A Removable media bay B (B) SATA DVD-ROM Drive (Standard in all BTO Models) C Optical Drive (blank) 1-8 Eight SFF SAS/SATA HD Bays (Standard in all BTO Models) A Removable media bay B SATA DVD-ROM Drive (Standard in all BTO Models) C Optical Drive (blank) 1-8 Eight SFF SAS/SATA HD Bays (Standard in all BTO Models) 1-24 Twenty-four small form factor (SFF) hot-plug drive bays to support Serial-attached SCSI (SAS) and Serial ATA (SATA) drives with optional drive cages (up to three 8 SFF drive cage can be installed) 1-14 Fourteen large form factor (LFF) hot-plug drive bays to support Serial-attached SCSI (SAS) and Serial ATA (SATA) drives with optional drive cages QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Storage DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 46
Drive Support Drive Support Drive Support Drive Support Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller Removable Media Removable Media Removable Media Removable Media Half-Height SATA DVD- ROM Optical Drive Up to 2 A, B Integrated IDE Half-Height SATA DVD RW Optical Drive Up to 2 A, B Integrated IDE HP Slim SATA DVD-ROM Optical Drive Up to 2 NOTE: NOTE: NOTE: NOTE: Also please use if the 3 drive cage is populated C Integrated IDE HP Slim SATA DVD RW Optical Drive Up to 2 NOTE: NOTE: NOTE: NOTE: Also please use if the 3 drive cage is populated C Integrated IDE Hard Drives Hard Drives Hard Drives Hard Drives NOTE: NOTE: NOTE: NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details. SAS Hot Plug SFF Enterprise (ENT) Drives SAS Hot Plug SFF Enterprise (ENT) Drives SAS Hot Plug SFF Enterprise (ENT) Drives SAS Hot Plug SFF Enterprise (ENT) Drives Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 300GB 6G SAS 10K DP 300GB 3G SAS 10K DP 146GB 6G SAS 10K DP 146GB 3G SAS 10K DP 146GB 3G SAS 15K DP 72GB 3G SAS 10K DP 72GB 3G SAS 15K DP 36GB 3G SAS 15K DP Up to 24 1-8 1-24 HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller SAS Hot Plug 3.5" Enterprise (ENT) Drives SAS Hot Plug 3.5" Enterprise (ENT) Drives SAS Hot Plug 3.5" Enterprise (ENT) Drives SAS Hot Plug 3.5" Enterprise (ENT) Drives Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 450GB 3G SAS 15K DP 400GB 3G SAS 10K DP 146GB 3G SAS 15K DP 72GB 3G SAS 15K DP Up to 14 1-14 HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Storage DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 47
SAS Hot Plug 3.5" Midline (MDL) Drives SAS Hot Plug 3.5" Midline (MDL) Drives SAS Hot Plug 3.5" Midline (MDL) Drives SAS Hot Plug 3.5" Midline (MDL) Drives Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 1TB 3G SAS 7.2K DP 750GB 3G SAS 7.2K DP Up to 14 1-14 HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller SATA Hot Plug SFF Entry (ETY) Drives SATA Hot Plug SFF Entry (ETY) Drives SATA Hot Plug SFF Entry (ETY) Drives SATA Hot Plug SFF Entry (ETY) Drives Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 250GB 3G SATA 5.4K 120GB 1.5G SATA 5.4K Up to 24 1-8 1-24 HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller SATA Hot Plug 3.5" Midline (MDL) Drives SATA Hot Plug 3.5" Midline (MDL) Drives SATA Hot Plug 3.5" Midline (MDL) Drives SATA Hot Plug 3.5" Midline (MDL) Drives Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 1TB 3G SATA 7.2K 750GB 3G SATA 7.2K 500GB 3G SATA 7.2K 250GB 3G SATA 7.2K Up to 14 1-14 HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Storage DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 48
External Storage External Storage External Storage External Storage Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Host Controller or Adapter Host Controller or Adapter Host Controller or Adapter Host Controller or Adapter 50 Modular Smart Array Up to 4 External HP Smart Array P800/512 BBWC Controller 60 Modular Smart Array Up to 4 External HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller Up to 8 HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller 70 Modular Smart Array Up to 2 External HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller Up to 4 HP Smart Array P800/512 BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller Tape and Disk-Based Backup Tape and Disk-Based Backup Tape and Disk-Based Backup Tape and Disk-Based Backup NOTE: NOTE: NOTE: NOTE: For a complete listing of compatible tape and disk-based backup offerings, please visit: www.hp.com/go/connect . Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller Part Number Part Number Part Number Part Number Internal USB Tape Drives Internal USB Tape Drives Internal USB Tape Drives Internal USB Tape Drives DAT 40 USB DAT 72 USB DAT 160 USB B,C USB 2.0 Port N/A USB Tape Drives, External USB Tape Drives, External USB Tape Drives, External USB Tape Drives, External DAT 40 USB DAT 72 USB DAT 160 USB 1U Rack-Mount Kit External USB 2.0 Port N/A SAS Tape Drives, Internal SAS Tape Drives, Internal SAS Tape Drives, Internal SAS Tape Drives, Internal DAT 160 SAS LTO-2 Ultrium 448 SAS LTO-3 Ultrium 920 SAS LTO-4 Ultrium 1760 SAS B,C HP Smart Array P212/Zero Memory Controller 462828-B21 SAS Tape Drives, Internal SAS Tape Drives, Internal SAS Tape Drives, Internal SAS Tape Drives, Internal LTO-4 Ultrium 1840 SAS B C HP Smart Array P212/Zero Memory Controller 462828-B21 SAS Tape Drives, External SAS Tape Drives, External SAS Tape Drives, External SAS Tape Drives, External DAT 160 SAS LTO-2 Ultrium 448 SAS LTO-3 Ultrium 920 SAS LTO-4 Ultrium 1760 SAS LTO-4 Ultrium 1840 SAS 1U Rack-Mount 3U Rack-Mount External HP Smart Array P212/Zero Memory Controller 462828-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Storage DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 49
SAS Tape Automation, SAS Tape Automation, SAS Tape Automation, SAS Tape Automation, External External External External 1/8 G2 Autoloader MSL2024 MSL4048 MSL8096 External HP Smart Array P212/Zero Memory Controller 462828-B21 Fibre Tape Automation, Fibre Tape Automation, Fibre Tape Automation, Fibre Tape Automation, External External External External MSL2024 MSL4048 MSL8096 MSL6000 External Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs for detailed connectivity information. N/A HP StorageWorks RDX HP StorageWorks RDX HP StorageWorks RDX HP StorageWorks RDX Removable Disk Backup Removable Disk Backup Removable Disk Backup Removable Disk Backup System, Internal System, Internal System, Internal System, Internal RDX160 RDX320 RDX500 B,C USB 2.0 Port N/A HP StorageWorks RDX HP StorageWorks RDX HP StorageWorks RDX HP StorageWorks RDX Removable Disk Backup Removable Disk Backup Removable Disk Backup Removable Disk Backup System, External System, External System, External System, External RDX160 RDX320 RDX500 External USB 2.0 Port N/A HP StorageWorks D2D HP StorageWorks D2D HP StorageWorks D2D HP StorageWorks D2D Backup Systems Backup Systems Backup Systems Backup Systems D2D120 D2D130 D2D2503i D2D4004i External Embedded Network Controller N/A QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Storage DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 50
HP 460W Power Supply HP 460W Power Supply HP 460W Power Supply HP 460W Power Supply Part Number - AC 460W PSU Part Number - AC 460W PSU Part Number - AC 460W PSU Part Number - AC 460W PSU 503296-B21 Input Voltage Range (Vrms) Input Voltage Range (Vrms) Input Voltage Range (Vrms) Input Voltage Range (Vrms) 100 to 240 Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) 50/60 Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) 100 100 100 100 120 120 120 120 208 208 208 208 200 200 200 200 220 220 220 220 230 230 230 230 240 240 240 240 Maximum Rated Output Wattage 460 460 460 460 460 460 460 Nominal Input Current (A rms) 5.5 4.5 2.6 2.5 2.4 2.3 2.2 Max Rated Input Wattage Rating (Watts) 526 520 505 505 503 503 503 Max. Rated VA (Volt-Amp) 548 542 527 527 524 524 524 Efficiency (%) at Max. Rated Output Wattage 87.5 88.5 91 91 91.5 91.5 91.5 Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97 Leakage Current (mA) 0.42 0.50 0.83 0.87 0.92 0.96 1.00 Max. Inrush Current (A peak) 30 30 30 30 30 30 30 Max. Inrush Current duration (mS) 20 20 20 20 20 20 20 Maximum British Thermal Unit Rating (BTU-Hr) 1794 1773 1725 1725 1715 1715 1715 HP 750W Power Supply HP 750W Power Supply HP 750W Power Supply HP 750W Power Supply Part Number - AC 750W PSU Part Number - AC 750W PSU Part Number - AC 750W PSU Part Number - AC 750W PSU 512327-B21 Input Voltage Range (Vrms) Input Voltage Range (Vrms) Input Voltage Range (Vrms) Input Voltage Range (Vrms) 100 to 240 Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) 50/60 Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) 100 100 100 100 120 120 120 120 208 208 208 208 200 200 200 200 220 220 220 220 230 230 230 230 240 240 240 240 Maximum Rated Output Wattage 750 750 750 750 750 750 750 Nominal Input Current (A rms) 8.9 7.4 4.3 4.1 3.9 3.7 3.6 Max Rated Input Wattage Rating (Watts) 857 847 824 825 820 820 820 Max. Rated VA (Volt-Amp) 894 884 859 859 854 854 854 Efficiency (%) at Max. Rated Output Wattage 87.5 88.5 91 91 91.5 91.5 91.5 Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97 Leakage Current (mA) 0.42 0.50 0.83 0.87 0.92 0.96 1.00 Max. Inrush Current (A peak) 30 30 30 30 30 30 30 Max. Inrush Current duration (mS) 20 20 20 20 20 20 20 Maximum British Thermal Unit Rating (BTU-Hr) 2925 2892 2812 2812 2797 2797 2797 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Power Specifications DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 51
HP 1200W Power Supply HP 1200W Power Supply HP 1200W Power Supply HP 1200W Power Supply Part Number - AC Part Number - AC Part Number - AC Part Number - AC 500172-B21 Operational Input Voltage Range Operational Input Voltage Range Operational Input Voltage Range Operational Input Voltage Range (Vrms) (Vrms) (Vrms) (Vrms) 100 to 240 Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) 50/60 Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) 100 100 100 100 120 120 120 120 208 208 208 208 200 200 200 200 220 220 220 220 230 230 230 230 240 240 240 240 Maximum Rated Output Wattage 800 900 1200 1200 1200 1200 1200 Nominal Input Current (A rms) 9.7 9.0 7.0 6.8 6.4 9.1 5.9 Max Rated Input Wattage Rating (Watts) 930 1034 1348 1348 1348 1348 1348 Max. Rated VA (Volt-Amp) 970 1079 1406 1406 1406 1406 1406 Efficiency (%) at Max. Rated Output Wattage 86 87 89 89 89 89 89 Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97 Leakage Current (mA) 0.42 0.50 0.83 0.87 0.92 0.96 1.00 Max. Inrush Current (A peak) 30 30 30 30 30 30 30 Max. Inrush Current duration (mS) 20 20 20 20 20 20 20 Maximum British Thermal Unit Rating (BTU-Hr) 3174 3530 4600 4600 4600 4600 4600 To review typical system power ratings use the Active Answers HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor To drill down to calculators: - Click on: "ProLiant Servers" - Click on the Server of interest. Example: DL370 G6 or ML370 G6 - Click on: "Power Calculator" link. (You may need to scroll down to see it) QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Power Specifications DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 52
System Unit System Unit System Unit System Unit Tower Dimensions Tower Dimensions Tower Dimensions Tower Dimensions (H x W x D) (with bezel) 18.52 x 9.75 x 29.12 in (47.04 x 24.77 x 73..96 cm) Rack Dimensions Rack Dimensions Rack Dimensions Rack Dimensions (H x W x D) (with bezel) 6.88 x 19.03 x 27.53 in (17.48 x 48.34 x 69.93 cm) Tower Weight Tower Weight Tower Weight Tower Weight (approximate) Maximum (two hard drives, power supply, and processor installed) 103.06 lbs (46.75 kg) Minimum (one hard drive, power supply, and processor installed) 66,14 lbs (30.00 kg) Rack Weight Rack Weight Rack Weight Rack Weight (approximate) Maximum (two hard drives, power supply, and processor installed) 103.06 lbs (46,75 kg) Minimum (one hard drive, power supply, and processor installed) 55.12 lbs (25.00 kg) Input Requirements Input Requirements Input Requirements Input Requirements (per power supply) Rated Line Voltage 90 - 132 VAC, 180 - 264 VAC Rated Input Current 7.5A (at 100 VAC), 3.8A (at 200 VAC) Rated Input Frequency 47 to 63 Hz Rated Input Power 980W (at 100 VAC) 1035W (at 120 VAC) 1170W (at 240 VAC) BTU Rating BTU Rating BTU Rating BTU Rating Maximum 460W - 1773 BTU / hr (at 120 VAC), 1715 (at 240 VAC) 750W - 2892 BTU / hr (at 120 VAC), 2797 (at 240 VAC) 1200W - 3530 BTU / hr (at 120 VAC), 4600 (at 240 VAC) Power Specifications Power Specifications Power Specifications Power Specifications To review typical system power ratings use the HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant- energy-efficient - Click on the system of interest. Example: DL370 G6 or ML370 G6 - Follow the instructions of the next screens. Power Supply Output Power Supply Output Power Supply Output Power Supply Output (per power supply) Rated Steady-State Power 460 W (at 100 VAC) Maximum Peak Power 460 W (at 200 VAC) 460 W (at 100 VAC) 460 W (at 200 VAC) NOTE: NOTE: NOTE: NOTE: See Power Supply Specifications tables for complete details on 460W PSU and optional 750W and 1200W Power Supply Options. System Inlet Temperature System Inlet Temperature System Inlet Temperature System Inlet Temperature Operating 10° to 35°C (50° to 95°F) at sea level with an QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Technical Specifications DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 53
altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). Non-operating -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). Relative Humidity Relative Humidity Relative Humidity Relative Humidity (non-condensing) Operating 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non- condensing. Non-operating 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non- condensing. Altitude Altitude Altitude Altitude Operating 3048 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). Non-operating 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). Acoustic Noise Acoustic Noise Acoustic Noise Acoustic Noise Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). Idle Idle Idle Idle L WAd 5.6 B for 1P Non-Redundant; 5.5 B for 2P Redundant L pAm 39 dB for 1P Non-Redundant; 39 dB for 2P Redundant Operating Operating Operating Operating L WAd 5.6 B for 1P Non-Redundant; 5.5 B for 2P Redundant L pAm 39 dB for 1P Non-Redundant; 39 dB for 2P Redundant NOTE: NOTE: NOTE: NOTE: The Listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels. Emissions Classification Emissions Classification Emissions Classification Emissions Classification (EMC) FCC Rating Class B Normative Standards CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Technical Specifications DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 54
NOTE: NOTE: NOTE: NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements. Smart Array P410i Smart Array P410i Smart Array P410i Smart Array P410i Controller Controller Controller Controller Dimensions Dimensions Dimensions Dimensions (not including bracket) Low Profile PCIe Form Factor 7.5 in x 9.5 in x 2.25 in (19.05 cm x 24.13 cm x 5.72 cm) Disk Drive and Enclosure Disk Drive and Enclosure Disk Drive and Enclosure Disk Drive and Enclosure Interface - Transfer rate Interface - Transfer rate Interface - Transfer rate Interface - Transfer rate 3G SAS (Serial Attached SCSI)/6G SAS Capable 1.5G SATA (Serial ATA)/3G SATA Capable SAS Connectors SAS Connectors SAS Connectors SAS Connectors 2 internal (Mini-SAS) x8 wide port connectors Cache Memory Speed Cache Memory Speed Cache Memory Speed Cache Memory Speed DDR2-800MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth. Server Interface Server Interface Server Interface Server Interface x8 5G PCIe 2.0 provides 4GB/s maximum bandwidth SAS Speed SAS Speed SAS Speed SAS Speed x8 3G SAS provides 2.4GB/s maximum bandwidth Cache Memory Cache Memory Cache Memory Cache Memory 40-bit 256MB ECC protected cache (72-bit 512MB BBWC module upgrades available); transportable with battery-backed upgrade Logical Drives Supported Logical Drives Supported Logical Drives Supported Logical Drives Supported Up to 12 logical drives Maximum Logical Drive Maximum Logical Drive Maximum Logical Drive Maximum Logical Drive Capacity Capacity Capacity Capacity Greater than 2TB Host Memory Addressing Host Memory Addressing Host Memory Addressing Host Memory Addressing 64-bit, supporting greater than 4GB server memory space RAID Support RAID Support RAID Support RAID Support RAID 6, 6 0 (Advanced Data Guarding) NOTE: NOTE: NOTE: NOTE: The minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade is required to enable RAID 6, 6 0 RAID 5, 5 0 (Distributed Data Guarding) NOTE: NOTE: NOTE: NOTE: The 256 MB & Battery Kit upgrade is required to enable RAID 5, 5 0 support of the Smart Array P410i RAID 1 0 (Striping & Mirroring) RAID 0 (Striping) Upgradeable Firmware Upgradeable Firmware Upgradeable Firmware Upgradeable Firmware Upgradeable Firmware with recovery ROM feature QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Technical Specifications DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 55
NC375i Integrated Quad NC375i Integrated Quad NC375i Integrated Quad NC375i Integrated Quad Port Multifunction Gigabit Port Multifunction Gigabit Port Multifunction Gigabit Port Multifunction Gigabit Server Adapter Server Adapter Server Adapter Server Adapter Network Interface Network Interface Network Interface Network Interface 10Base-T/100Base-TX/1000Base-TX Compatibility Compatibility Compatibility Compatibility IEEE 802.3 10Base-T IEEE 802.3ab 1000Base-T IEEE 802.3u 100Base-TX IEEE 802.3ad 1000Base-TX IEEE 802.1p 100Base-TX IEEE 802.1q 100Base-TX Data Transfer Method Data Transfer Method Data Transfer Method Data Transfer Method PCI Express, four lanes (x4) Network Transfer Rate Network Transfer Rate Network Transfer Rate Network Transfer Rate 10Base-T (Half-Duplex) 10 Mb/s 10Base-T (Full-Duplex) 20 Mb/s 100Base-TX (Half-Duplex) 100 Mb/s 100Base-TX (Full-Duplex) 200 Mb/s 1000Base-TX (Half and Full-Duplex) 2000 Mb/s Connector Connector Connector Connector RJ-45 Cable Support Cable Support Cable Support Cable Support 10Base-T Categories 3, 4 or 5 UTP up to 328 ft (100 m) 100Base-TX Category 5 or higher UTP; up to 328 ft (100 m) 1000Base-TX Category 5 or higher UTP; up to 328 ft (100 m) Environment-friendly Environment-friendly Environment-friendly Environment-friendly Products and Approach Products and Approach Products and Approach Products and Approach End-of-life Management End-of-life Management End-of-life Management End-of-life Management and Recycling and Recycling and Recycling and Recycling Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green . To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green . These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. © Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less. QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Technical Specifications DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 56
HP ProLiant ML370 G6 (Tower) HP ProLiant ML370 G6 (Tower) HP ProLiant ML370 G6 (Tower) HP ProLiant ML370 G6 (Tower) Front View: Front View: Front View: Front View: Rear View: Rear View: Rear View: Rear View: 1. Three Hot-plug fans (standard) Five (optional) 1. Expansion slot riser bay 2. Quick removal access panel 2. Four NIC connectors 3. Intel Quad-Core Processor (Performance model includes two processors) 3. Serial connector 4. Power supply bay 2 4. Eighteen slots for DDR3 Registered or Unbuffered Memory 5. Power supply bay 1 (populated) 5. SAS/SATA drive cage 6. Mouse connector 6. Optional drive cage bay 7. Keyboard connector 7. Power on/stanby button 8. Video connector 8. System Insight Display 9. Two USB connectors 9. Removal media bay 10. iLO 2 connector 10. DVD-ROM drive 11. 9 Available PCI-Express Gen2 expansion slots 11. Optional slimline optical drive bay 12. 9 Available PCI-Express Gen2 slots At A Glance At A Glance At A Glance At A Glance The next generation of the HP ProLiant ML370 (expandable tower chassis) and the new HP ProLiant DL370 (4U rack optimized chassis) deliver Industry-leading management tools, leading performance, expandability, flexibility and the latest energy efficient technologies. These servers are well-suited for deployment in growing businesses, remote office sites, or datacenters and have been designed to bring you (our customer) the utmost confidence to run your business. Features included in both the HP ProLiant ML370 G6 and the HP ProLiant DL370 G6: Processors: Processors: Processors: Processors: Up to two Intel® Xeon® 5500 Series processors Intel® 5520 chipset Memory: Memory: Memory: Memory: 18 DIMM slots Up to 144GB, using PC3-8500R DDR3 Registered (RDIMM) memory, operating at 800MHz when fully populated at 3 DIMMs per Channel in 18 slots. Up to 24GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully populated at 2 DIMMs per Channel in 12 slots. QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Overview DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 2
Storage Controller: Storage Controller: Storage Controller: Storage Controller: Entry Models: HP Smart Array P410i/256 MB Controller (RAID 0/1/1 0/5/5 0) NOTE: NOTE: NOTE: NOTE: Entry Models available for ML370 G6 models only. Base Models: HP Smart Array P410i/256 MB Controller (RAID 0/1/1 0/5/5 0) Performance Models: HP Smart Array P410i/512 MB BBWC Controller (RAID 0/1/1 0/5/5 0 Available upgrades: 256MB, 512MB with BBWC, Battery kit upgrade (for BBWC), and Smart Array Advanced Pack (SAAP) Internal Drive Support: Internal Drive Support: Internal Drive Support: Internal Drive Support: Up to 24 small form factor (SFF) or 14 large form factor (LFF) hot-plug drive bays to support Serial-attached SCSI (SAS) and Serial ATA (SATA) drives Standard half-height DVD-ROM (all models) Two open half-height media bays available for tape drives, optical media, optional SAS HDD cage Network Controller: Network Controller: Network Controller: Network Controller: HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Expansion Slots: Expansion Slots: Expansion Slots: Expansion Slots: Nine PCIe2 slots available (see "Standard Features -Expansion Slots" section below for more details) Graphic Cards Graphic Cards Graphic Cards Graphic Cards : Supports up to 3 x 300W Graphic Cards via Graphic Card Power Adapter kit NOTE: NOTE: NOTE: NOTE: 2 PCIe Gen2 x16 (mechanical/electrical); 1 PCIe Gen2 x16 (mechanical) x8 (electrical) Ports: Ports: Ports: Ports: USB 2.0 support 5 total ports: (2) ports up front; (2) ports in back; (1) port internal 1 internal Secure Digital (SD) slot Redundancy: Redundancy: Redundancy: Redundancy: Multiple layers of fault tolerance through critical component redundancy (power supply and fan redundancy), mirrored memory, embedded RAID capability, and full-featured remote Lights-Out management Power Sources: Power Sources: Power Sources: Power Sources: Dual Common Slot Bay for Right Sized, Hot plug and Redundant Power options HP 1200W CS HE Silver Power Supply (optional) HP 750W CS HE Gold Power Supply (standard on some models) HP 460W CS HE Gold Power Supply (standard on some models) Management: Management: Management: Management: HP Insight Control suite server management software HP ProLiant Onboard Administrator (powered by the HP Integrated Lights-Out 2 management processor) for simplified server setup, health monitoring and recovery, power and thermal control, and lights-out remote administration. Integrated Lights-Out 2 Advanced unlocks the full capabilities of the ProLiant Onboard Administrator with high performance Integrated Remote Console, multi-user console sharing, video record and replay, and virtual media, including virtual folders for rapid server updates. Convenient Systems Insight Display for quick and easy front view server diagnostics ProLiant Essential Foundation Pack standard, including HP Systems Insight Manager, SmartStart, SmartStart Scripting Toolkit, Subscriber's Choice and ROM Based Setup Utility (RBSU) Automatic Server Recovery (ASR), ROM Based Setup Utility (RBSU), HP System Insight Manager, Status LEDs including system health, UID, and SmartStart Form Factor: Form Factor: Form Factor: Form Factor: 4U Tower Chassis and 4U Rack Optimized Chassis Redesigned 4U Tower Chassis and the new 4U Rack Optimized Chassis to better meet our customer's density requirements Operating Systems: Operating Systems: Operating Systems: Operating Systems: Supports Windows, RHEL, SLES, OEL, Solaris, VMware, and Citrix Essentials for XenServer Deployment/Serviceability: Deployment/Serviceability: Deployment/Serviceability: Deployment/Serviceability: Quick Deploy Rail System includes sliding universal rails, an ambidextrous cable management arm and quick release levers for fast and easy serviceability QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Overview DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 3
Tool-less access to all system components for easy in rack serviceability Customer Self Repair (CSR): HP products are designed with many CSR parts to minimize repair time and allow for greater flexibility in performing defective parts replacement Warranty: Warranty: Warranty: Warranty: This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners resellers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. SATA hard drives have a one-year warranty. SAS Enterprise drives have a three-year warranty. NOTE: NOTE: NOTE: NOTE: Server Warranty includes 3-Year Parts, 3-Year Labor, 3-Year Onsite support with next business day response. Warranty repairs may be accomplished through the use of Customer Self Repair (CSR) parts. These parts fall into two categories: 1) Mandatory CSR parts are designed for easy replacement. A travel and labor charge will result when customers decline to replace a Mandatory CSR part; 2) Optional CSR parts are also designed for easy replacement but may involve added complexity. Customers may choose to have HP replace Optional CSR parts at no charge. Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Overview DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 4
NOTE: NOTE: NOTE: NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. Processor Processor Processor Processor One of the following depending on Model Quad-Core Processors Quad-Core Processors Quad-Core Processors Quad-Core Processors Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) Dual-Core Processors Dual-Core Processors Dual-Core Processors Dual-Core Processors Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) NOTE: NOTE: NOTE: NOTE: Up to 2 processors supported. Performance configurations include two processors. Mixing different processor models is not supported. NOTE: NOTE: NOTE: NOTE: HT indicates that the processor model supports Intel® Hyper-Threading Technology. NOTE: NOTE: NOTE: NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active. NOTE: NOTE: NOTE: NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: NOTE: NOTE: NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. Cache Memory Cache Memory Cache Memory Cache Memory One of the following depending on Model 8MB (1 x 8MB) Level 3 cache NOTE: NOTE: NOTE: NOTE: All processor models except for those identified below. 4MB (1 x 4MB) Level 3 cache NOTE: NOTE: NOTE: NOTE: For processors E5506/E5504/E5502. Chipset Chipset Chipset Chipset Intel® 5520 chipset NOTE: NOTE: NOTE: NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/ . Upgradeability Upgradeability Upgradeability Upgradeability Upgradeable to 2 processors Memory Protection Memory Protection Memory Protection Memory Protection Advanced ECC Mirroring mode Lock-step mode QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 5
Memory Memory Memory Memory Type DDR3 Registered (RDIMM) or Unbuffered (UDIMM) Standard (Performance Models) 12 GB (6 x 2 GB) RDIMM Standard (Base Models) 6 GB (3 x 2 GB) RDIMM Standard (Entry Model) 4 GB (2 x 2 GB) UDIMM Maximum (RDIMM) 144 GB (18 x 8 GB) for Registered Memory configurations Maximum (UDIMM) 24 GB (12 x 2 GB) for Unbuffered Memory configurations NOTE: NOTE: NOTE: NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator . DDR3 memory options part number decoder DDR3 memory options part number decoder DDR3 memory options part number decoder DDR3 memory options part number decoder Network Controller Network Controller Network Controller Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Expansion Slots Expansion Slots Expansion Slots Expansion Slots Expansion Slots Expansion Slots Expansion Slots Expansion Slots # # # # Technology Technology Technology Technology Width Width Width Width Connector Connector Connector Connector Width Width Width Width * Form Factor Form Factor Form Factor Form Factor Notes Notes Notes Notes 1 PCIe x4 x8 Half length, full height slot 2 PCIe2 x4 x8 Full length, full height slot 3 PCIe2 x16 x16 Full length, full height slot 4 PCIe2 x4 x8 Full length, full height slot 5 PCIe2 x4 x8 Full length, full height slot 6 PCIe2 x8 x16 Full length, full height slot 7 PCIe2 x4 x8 Full length, full height slot QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 6
8 PCIe2 x16 x16 Full length, full height slot 9 PCIe2 x4 x8 Full length, full height slot 10 PCIe2 X8 X8 Half length, full height slot Utilized by NIC controller "Use the correct model number for the NIC" * Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number. Storage Controller Storage Controller Storage Controller Storage Controller One of the following depending on Model Entry Models HP Smart Array P410i/256 MB Controller (RAID 0/1/1 0/5/5 0) Base Models HP Smart Array P410i/256 MB Controller (RAID 0/1/1 0/5/5 0) Performance Models HP Smart Array P410i/512 MB BBWC Controller (RAID 0/1/1 0/5/5 0/6) Available upgrades: 256MB, 512MB with BBWC, Battery kit upgrade (for BBWC), and Smart Array Advanced Pack (SAAP). Storage Storage Storage Storage Diskette Drive None Standard Optical Drive SATA DVD ROM (standard in all models) Hard Drives None Standard Maximum Internal Maximum Internal Maximum Internal Maximum Internal Storage Type Storage Type Storage Type Storage Type Hot Plug SFF SAS 7.20TB 24 x 300GB Hot Plug LFF SAS 14 TB 14 x 1TB Interfaces Interfaces Interfaces Interfaces Serial 1 (rear) Pointing Device (Mouse) 1 VGA 1 ( 1 front VGA on rack models) Keyboard 1 Network RJ-45 4 (rear) ILO 2.0 remote management port 1 SD slot 1 USB 2.0 Ports 5 (2 on the rear, 2 on the front, 1 internal) NOTE: NOTE: NOTE: NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html Dedicated USB 2.0 Port 1 (available for DAT USB tape connectivity) NOTE: NOTE: NOTE: NOTE: Internal USB ports are optimal for the attachment of HP DAT USB Internal Tape Drives QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 7
Graphics Graphics Graphics Graphics Integrated ATI RN50, 64 MB video standard 16 bit color: maximum resolution of 1600 x 1200 32 bit color: maximum resolution of 1280 x 1024 NOTE: NOTE: NOTE: NOTE: Maximum resolution available via iLO 2 remote console is 1280 x 1024. Form Factor Form Factor Form Factor Form Factor 4U Rack and Tower form factor (7 in, 17.8 cm) HP Insight Control suite HP Insight Control suite HP Insight Control suite HP Insight Control suite HP Insight Control suite delivers essential management, including proactive health management, lights out remote control, optimization of power usage, rapid server deployment, performance analysis, vulnerability scanning and patch management and virtual machine management. HP Insight Control suite installs and licenses the following components by default using a wizard-based integrated installer: HP Systems Insight Manager HP iLO Advanced Pack HP Insight Rapid Deployment software HP Insight Power Manager software HP Insight Performance Manager module HP Insight Vulnerability and Patch Manager module HP Insight Virtual Machine Manager software for ProLiant Additional Insight Software standalone products and management tools included on the Insight Software media kit can be installed manually: HP Insight Server Migration software for ProLiant NOTE: NOTE: NOTE: NOTE: HP Insight Server Migration software for ProLiant is licensed separately from Insight Control suite. HP Insight Remote Support Standard HP Insight Remote Support Advanced (previously Service Essentials Remote Support Pack) NOTE: NOTE: NOTE: NOTE: HP Insight Server Migration software for ProLiant can be installed from the SMP CD included in the Insight Software media kit. NOTE: NOTE: NOTE: NOTE: For additional product and licensing information about HP Insight Control suite, visit: http://www.hp.com/go/ice . NOTE: NOTE: NOTE: NOTE: As of Feb. 1, 2009, HP iLO Power Management Pack is being discontinued. Customer can either purchase HP Insight Control suite which contains all the components of IPMP or the standalone components which include iLO Advanced, Insight Power Manager software and System Insight Manager. HP Insight Control Environment for Linux (ICE-Linux) provides comprehensive discovery, imaging & deployment, monitoring, and management for Linux-based ProLiant server platforms. Built on the industry-leading HP Systems Insight Manager framework, this solution integrates open source technology with experience leveraged from HP's Linux products in HP ICLE and HP XC Clusters, while providing paths to the future with developing management technologies. HP Insight Control suite and most HP Insight Software products include a one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 8
http://www.hp.com/services/insight . HP ProLiant Onboard HP ProLiant Onboard HP ProLiant Onboard HP ProLiant Onboard Administrator Administrator Administrator Administrator HP ProLiant Onboard Administrator (powered by the Integrated Lights-Out 2 management processor) simplifies server setup, health monitoring, power and thermal control, and lights-out remote administration of ProLiant ML, DL, and BL servers. HP ProLiant Onboard Administrator functions without additional software, and can be accessed from any location via a web browser. It works hand-in-hand with HP Systems Insight Manager, Insight Control, and Insight Dynamics - VSE suite helping customers unlock the value of the ProLiant platform and deliver the highest possible quality of IT service to the business. Capabilities of the HP ProLiant Onboard Administrator embedded in ProLiant ML/DL servers include, but are not limited to the following: Rom-based Setup Utility (RBSU) and Option Rom Configuration for Arrays (ORCA) IML and iLO event logging Automatic Server Recovery (ASR) OS independent hardware health status Present server power consumption Virtual Unit ID control Remote serial console Virtual power button control Dynamic Sector Repairing (with Smart Array controller) Drive Parameter Tracking (with Smart Array controller) Hot Spare Boot NOTE: NOTE: NOTE: NOTE: Upon the event of a failed processor in a multi-processing environment, the system will automatically reboot and attempt to use the remaining good processor. Unlock the full remote administration capabilities of HP ProLiant Onboard Administrator with Integrated Lights-Out 2 Advanced. Server Management Server Management Server Management Server Management Stand Alone Software Stand Alone Software Stand Alone Software Stand Alone Software Product - ProLiant Product - ProLiant Product - ProLiant Product - ProLiant Essentials Essentials Essentials Essentials HP Systems Insight Manager HP Systems Insight Manager (HP SIM) provides a unified, secure and extensible standards-based environment to centrally manage servers, storage and other infrastructure devices, (both HP and non-HP) across multiple operating system platforms. For additional information, please see: www.hp.com/go/insight HP Insight Rapid Deployment software HP Insight Rapid Deployment Software (RDP) extends HP Systems Insight Manager with a complete deployment solution for HP ProLiant servers. RDP provides a central location to configure server hardware, deploy Windows, Linux and VMware ESX operating environments and install HP ProLiant Support Pack drivers using images and scripted profiles. For more information, visit: http://www.hp.com/go/rdp . HP Server Migration Pack - Universal Edition Upgrading, replacing, or virtualizing your existing server? Effortlessly transition to new virtual or physical HP ProLiant servers or BladeSystem with automated, accurate and affordable migration of OS, application and data. SMP Universal automates the manual processes required for migrating servers between physical or virtual platforms, whether migrating to VMware or Microsoft virtual machines. SMP Universal allows all of the following migrations: QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 9
physical to ProLiant physical to virtual virtual to virtual virtual to ProLiant NOTE: NOTE: NOTE: NOTE: For more information, visit: http://www.hp.com/go/migrate . HP Insight Dynamics - VSE suite for ProLiant The HP Insight Dynamics - VSE suite for ProLiant is advanced infrastructure management software that allows you to analyze and optimize your adaptive infrastructure to manage physical and virtual resources in the same way. HP Insight Dynamics - VSE gives you a powerful toolkit to accelerate complex technology projects and simplify daily operations. It enables you to plan capacity and power continuously, balance across physical and virtual resources, ensure cost-effective high availability and provision infrastructure consistently. HP Insight Orchestration, an optional extension to Insight Dynamics - VSE, enables IT organizations to provision infrastructure consistently and automatically from pools of shared resources using a self-service portal. Resources provisioned can range from a single virtual machine to complex multi-tier environments and their associated physical and virtual resource requirements. HP Insight Recovery, also an optional extension for Insight Dynamics - VSE, enables cost-effective disaster recovery for physical and virtual environments. Application environments can be reactivated in minutes with the touch of a button to a remote location NOTE: NOTE: NOTE: NOTE: For more information, visit: http://www.hp.com/go/insightdynamics , http://www.hp.com/go/insightorchestration , www.hp.com/go/insightrecovery HP Integrated Lights-Out (iLO) Advanced Pack Unlocks the full capabilities of the ProLiant Onboard Administrator with comprehensive remote control including Virtual KVM remote graphical console, power management capabilities such as power measurement, regulation, and capping, new iLO Text Console, automatic and on-demand video recording of server events, global team collaboration for up to four remote users, virtual media (floppy, CD/DVD, USB key), virtual folders, and enterprise security (directory services and two-factor authentication). For additional information, please see: www.hp.com/go/iLO HP iLO Power Management Pack Energy-efficient management software that delivers centralized control, reliable security, and energy savings for your BladeSystem infrastructure. iPMP combines the total control of iLO 2 Advanced in the area of remote management with the energy monitoring and control of the Insight Power Manager to deliver a robust solution capable of full remote control and power management of ProLiant servers through a unified interface within HP Systems Insight Manager. For additional information, please see: www.hp.com/go/iLO HP Accelerated iSCSI Pack Enables the embedded Multifunction network controller to serve as both a NIC and an iSCSI HBA providing access to SAN storage over the same connection used for networking. Processing of the protocol stack is offloaded to the NIC reducing CPU utilization and greatly improving the speed with which the requests are processed and sent to the network. For additional information, please see: www.hp.com/go/iscsi QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 10
HP Insight Power Manager (IPM) Upgrades the single-server remote management capabilities of iLO Select/Advanced to include centralized reporting and policy-based management of power consumption and thermal output provided by the Insight Power Manager. IPM unifies all of this functionality within a single user interface - HP Systems Insight Manager. For additional information, please see: www.hp.com/go/ipm NOTE: NOTE: NOTE: NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to: http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. Core Infrastructure Core Infrastructure Core Infrastructure Core Infrastructure Management Management Management Management HP Foundation Pack Managing the growing number of servers can be complex and expensive for your organization. IT managers need to address changing business needs with tools that meet the challenges of managing today's complex Datacenters. HP provides management solutions that are designed to simplify a server's installation, configuration and maintenance throughout the entire server lifecyle. This provides the customer with higher levels of operational efficiency and highly reliable systems: www.hp.com/go/foundation . The foundation pack includes: HP SmartStart HP Management HP ProLiant Firmware Maintenance SmartStart version supported (minimum): SmartStart 8.20 http://www.hp.com/servers/smartstart NOTE: NOTE: NOTE: NOTE: In an effort to support reducing our environmental impact, the HP ProLiant Essentials Foundation Pack media will be available as a selectable option for this server at time of order of a CTO SKU. This will allow customers to order the number of media kits that best meet their needs and eliminate receiving unnecessary duplicate media. Insight Management Providers (WBEM) The HP Insight Management WBEM Providers leverage the rich set of base- level instrumentation provided by the system management controllers and drivers, I/O controllers and drivers, and system firmware interfaces delivering in-depth hardware management, including hardware inventory data, system state, and event notifications. Key Benefits Include: Heightened Security Single integrated Security Model Built using industry standard secure protocols and encryption algorithms (SSL, SSH) Reduce the number of entry points into internal network Reduced complexity of setup and configuration Delivers standards-based management across vendor platforms Robust in-depth and usable data that is provided to the HP System Management Homepage and Central Management Console Guaranteed event delivery Reduces overall load on the server by smaller agent footprint and maintenance burden QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 11
Provides in-depth hardware management, inventory data, system state, and event notifications The Insight Management Providers are included on ProLiant Support Packs. For additional information about the Management Providers please visit http://www.hp.com/go/HPwbem Insight Management Agents (SNMP) The Insight Management Agents should be installed on all HP servers to present system instrumentation, health and configuration information into HP Systems Insight Manager and the HP System Management Homepage. The HP System Management Homepage aggregates systems data from Insight Management Agents and other HP management tools, providing a consolidated browser-based interface for managing individual servers. Insight Management Agents and The HP System Management Homepage are included on ProLiant Support Packs, and can also be installed using the server profiles provided with the Rapid Deployment Pack. For additional information about the Management Agents and the HP System Management Homepage please visit the management Web site at: http://www.hp.com/servers/manage . Subscriber's Choice Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides software and driver change notifications for ProLiant products. Sign up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis. ProLiant Support Packs and ROMPaq, software The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options, available through ProLiant Support Packs the HP Insight Rapid Deployment Software, SmartStart or downloaded from software and drivers download pages website at: http://www.hp.com/go/support . HP Serviceguard for Linux HP Serviceguard for Linux HP Serviceguard for Linux HP Serviceguard for Linux (SGLX) (SGLX) (SGLX) (SGLX) HP Serviceguard for Linux provides high availability clustering for Linux applications running on HP Integrity, HP ProLiant and other supported industry-standard servers. Serviceguard for Linux reduces planned and unplanned downtime and delivers efficient, continuous access to business-critical applications - with all of the enterprise features you expect from HP. This high availability clustering solution is designed to protect applications and services from a wide variety of software and hardware failures, monitoring the health of each server (node) and quickly responding to failures such as those that affect system processes, system memory, LAN media and adapters, and application processes. For the most recent list of Linux distributions & kernels, servers and storage supported with Serviceguard for Linux, please see: ftp://ftp.compaq.com/pub/products/servers/ha/linux/SGLX_Certification_Matrix.pdf The following is a quick summary of HP Serviceguard for Linux features and support: Supported Virtual Machines SG/LX in HP Integrity Virtual Machines guests SG/LX in VMware ESX guests SG/LX in Red Hat and SUSE Xen hosts (DOM0) QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 12
Application Integration Toolkits HP Serviceguard for Linux Oracle Database Toolkit HP Serviceguard Extension for SAP on Linux (SGeSAP/LX) Free Application Integration Toolkits: Apache MySQL NFS PostgreSQL Samba Tomcat Sendmail Disaster Tolerant Solutions HP Serviceguard for Linux Extended Distance Cluster (XDC) extends cluster distances up to 100 km, utilizes software RAID mirroring for data replication and is storage array independent HP StorageWorks XP/EVA Cluster Extension Software for Linux (CLX) works seamlessly with HP Serviceguard for Linux, HP StorageWorks Continuous Access, and HP Disk Arrays to automate failover and failback between sites Software updates are distributed by HP Services to customers with support contracts NOTE: NOTE: NOTE: NOTE: For additional information including software and server support on HP Serviceguard for Linux, visit: http://www.hp.com/go/sglx or see the HP Serviceguard for Linux QuickSpecs. NOTE: NOTE: NOTE: NOTE: HP Serviceguard for Linux products for HP ProLiant and select 3rd party x86 class servers include one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/swsupport . Industry Standard Industry Standard Industry Standard Industry Standard Compliance Compliance Compliance Compliance ACPI V2.0 Compliant PCI-Express Gen2 PXE Support WOL Support Microsoft® Logo certifications USB 2.0 SMBIOS 2.6.1 Security Security Security Security Power-on password Keyboard password Diskette drive control Diskette boot control QuickLock, Network Server Mode Parallel and serial interface control Administrator's password QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 13
Security Trusted Platform Security Trusted Platform Security Trusted Platform Security Trusted Platform Module Module Module Module The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys. Windows® BitLocker⢠Drive Encryption (BitLocker) is a data protection feature available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running Windows Server 2008 has not been tampered with while the system was offline. For more information about TPM, including a white paper, go to www.hp.com/go/TPM NOTE: NOTE: NOTE: NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment. NOTE: NOTE: NOTE: NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing the key could result in data loss. Server Power Cords Server Power Cords Server Power Cords Server Power Cords High voltage power cord ships standard with all part numbers. Localized cables included with geographic specific models in other world regions. NOTE: NOTE: NOTE: NOTE: ProLiant DL servers no longer ship standard with NEMA power cords (187335-001) that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected to PDU's in data center racks so they now ship standard with only a PDU power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle (NEMA-15), the above NEMA power cord must be ordered separately. UPS Power Cord Matrix UPS Power Cord Matrix UPS Power Cord Matrix UPS Power Cord Matrix Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and specifications for UPS and PDU units: http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/index.html Power Supply Power Supply Power Supply Power Supply HP has a new design for ProLiant power. The new Common Slot Power Supply bay. This design provides the customer with commonality in power supplies across multiple platforms to save on the cost of spares and allows HP to offer multiple power solutions to fit the customers' needs. Many HP ProLiant Servers come with Common Slot, High Efficiency and Right-Size Power Supplies. Common Slot (CS) designates commonality of the power supply across multiple ProLiant servers. HP's new Common Slot power supplies are designed for highest efficiency to provide power efficiency without degrading performance of the ProLiant. Power Supplies will have efficiency ratings up to 92%. There are three Right Size power options available, depending on the configuration of your server. To make sure you select the correct power supply to meet your configuration, we suggest that you use the HP Power Advisor to decide the "Right-Size" for your configuration. All HP Common Slot power sources are UL, CE Mark Compliant, Hot Plug and Redundant. QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 14
Common Slot ProLiant Common Slot ProLiant Common Slot ProLiant Common Slot ProLiant It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for your needs. HP offers three Power Supply Options: 460Watts, Common Slot,92% Efficiency 750Watts, Common Slot, 92% Efficiency 1200Watts, Common Slot, 90% Efficiency HP's ProLiant Common Slot Power supplies (460W & 750W) meet multiple Energy Efficiency Initiatives. Climate Savers Computing Initiative GOLD, ECOS Consulting 80PLUS GOLD and plans on offering models that meet the Energy Star for Server requirements when they are published. HP's ProLiant Common Slot Power supplies (1200W) meet multiple Energy Efficiency Initiatives. Climate Savers Computing Initiative Bronze, ECOS Consulting 80PLUS Bronze Power Supply requirements. Redundant Power: Optional (1 1 or n n redundant) power supplies can be purchased through power supply option kits (see Redundant Options for part numbers). System Fans System Fans System Fans System Fans (3) Hot Plug fans ship standard (for full redundancy you can purchase the HP ML and DL 370G6 Redundant Fan Kit; PN: 508107-B231) Required Cabling Required Cabling Required Cabling Required Cabling For external storage cabling information, refer to the Web site at: www.hp.com/servers/dl370 or www.hp.com/servers/ml370 . OS Support OS Support OS Support OS Support Microsoft Windows Server Microsoft Windows Server Hyper V Red Hat Enterprise Linux (RHEL) SUSE Linux Enterprise Server (SLES) Oracle Enterprise Linux 5 (OEL) Solaris 10 for x86/x64 based Systems VMware Citrix Essentials for XenServer NOTE: NOTE: NOTE: NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/ossupport and our driver download page http://www.hp.com/support/ML370G6 . QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 15
Rack Airflow Rack Airflow Rack Airflow Rack Airflow Requirements Requirements Requirements Requirements Rack 10000 series Cabinets Rack 10000 series Cabinets Rack 10000 series Cabinets Rack 10000 series Cabinets The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. CAUTION: CAUTION: CAUTION: CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: Front and rear doors : If your 42U server rack includes closing front and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation). Side : The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm). CAUTION: CAUTION: CAUTION: CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. NOTE: NOTE: NOTE: NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: www.hp.com/servers/dl370 or www.hp.com/servers/ml370 . Telco Rack Support Telco Rack Support Telco Rack Support Telco Rack Support ProLiant rack mount servers and tower-to-rack kits include snap-on quick deploy side rails designed to accommodate both round and square hole rack rails. Telco rack solutions for ProLiant servers are available through the following URL: http://www.racksolutions.com/hp . Factory Express Portfolio Factory Express Portfolio Factory Express Portfolio Factory Express Portfolio for Servers and Storage for Servers and Storage for Servers and Storage for Servers and Storage HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to: http://www.hp.com/go/factory-express . HP Enterprise HP Enterprise HP Enterprise HP Enterprise Configurator Configurator Configurator Configurator The HP eConfigure-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. http://www.hp.com/products/configurator QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 16
Service and Support Service and Support Service and Support Service and Support HP Care Pack services provide total care and support expertise with committed response designed to meet your IT and business needs. HP Care Pack services include coverage for the HP branded hardware options qualified for the server and purchased at the same time or afterward that are internal to the enclosure. This also includes the 22" and smaller external monitors and tower UPS options up to 3kVA. These items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, and standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. To fully capitalizing on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions, provides a range of support services designed to meet the varying needs of your business. Whether an SMB, or large global corporation, HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime. Recommended Service Recommended Service Recommended Service Recommended Service - simplify ProLiant solution implementation, maintenance, and management. Support Support Support Support - 3-Year 4-Hour response 24x7 Same Business Day Coverage only Deployment Service Deployment Service Deployment Service Deployment Service - Installation and Start up only Enhanced Service Enhanced Service Enhanced Service Enhanced Service - optimize service level to increase IT performance and availability. Support Support Support Support - 3-Year Support Plus 24 only Refer to the information on "Installation & Start-Up" for service on ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet; to be delivered on a scheduled basis 8am-5pm, M-F, excluding HP holidays. NOTE: NOTE: NOTE: NOTE: For a complete listing of service offerings and information visit: http://www.hp.com/services/proliantservices http://www.hp.com/go/proliant/carepack QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Standard Features DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 17
NOTE: NOTE: NOTE: NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. Tower Models Tower Models Tower Models Tower Models HP ML370 G6 Base HP ML370 G6 Base HP ML370 G6 Base HP ML370 G6 Base Model Model Model Model ML370 E5540 6GB ML370 E5540 6GB ML370 E5540 6GB ML370 E5540 6GB 487791-xx1 Processor(s) Processor(s) Processor(s) Processor(s) (1) Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Cache Memory Cache Memory Cache Memory Cache Memory 8MB (1 x 8MB) Level 3 cache Memory Memory Memory Memory 6 GB (3 x 2 GB) PC3-10600 (DDR3-1333) Registered DIMMs Network Controller Network Controller Network Controller Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Storage Controller Storage Controller Storage Controller Storage Controller HP Smart Array P410i/256MB Controller Hard Drive Hard Drive Hard Drive Hard Drive None ship standard Internal Storage Internal Storage Internal Storage Internal Storage (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) Optical Drive Optical Drive Optical Drive Optical Drive SATA DVD ROM PCI-Express Slots PCI-Express Slots PCI-Express Slots PCI-Express Slots 10 slots - (9) available PCI-e Gen2 slots ( NOTE: NOTE: NOTE: NOTE: 10 slots available, one is taken by the NIC riser card ) Power Supply Power Supply Power Supply Power Supply (1) 750W Hot Plug Power Supply Fans Fans Fans Fans (3) Hot Plug Fans Form Factor Form Factor Form Factor Form Factor 4U Tower HP ML370 G6 Entry HP ML370 G6 Entry HP ML370 G6 Entry HP ML370 G6 Entry Model Model Model Model ML370 E5520 4GB ML370 E5520 4GB ML370 E5520 4GB ML370 E5520 4GB 487795-xx1 Processor(s) Processor(s) Processor(s) Processor(s) (1) Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Cache Memory Cache Memory Cache Memory Cache Memory 8MB (1 x 8MB) Level 3 cache Memory Memory Memory Memory 4 GB (2 x 2 GB) PC3-10600E (DDR3-1333) Registered DIMMs Network Controller Network Controller Network Controller Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Storage Controller Storage Controller Storage Controller Storage Controller HP Smart Array P410i/256MB Controller Hard Drive Hard Drive Hard Drive Hard Drive None ship standard Internal Storage Internal Storage Internal Storage Internal Storage (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) Optical Drive Optical Drive Optical Drive Optical Drive SATA DVD ROM PCI-Express Slots PCI-Express Slots PCI-Express Slots PCI-Express Slots 10 slots - (9) available PCI-e Gen2 slots ( NOTE: NOTE: NOTE: NOTE: 10 slots available, one is taken by the NIC riser card ) Power Supply Power Supply Power Supply Power Supply (1) 460W Hot Plug Power Supply Fans Fans Fans Fans (3) Hot Plug Fans Form Factor Form Factor Form Factor Form Factor 4U Tower QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 18
Rack Models Rack Models Rack Models Rack Models HP DL370 G6 Base HP DL370 G6 Base HP DL370 G6 Base HP DL370 G6 Base Model Model Model Model DL370 E5530 6GB DL370 E5530 6GB DL370 E5530 6GB DL370 E5530 6GB 487794-xx1 Processor(s) Processor(s) Processor(s) Processor(s) (1) Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) Cache Memory Cache Memory Cache Memory Cache Memory 8MB (1 x 8MB) Level 3 cache Memory Memory Memory Memory 6 GB (3 x 2 GB) PC3-10600 (DDR3-1333) Registered DIMMs Network Controller Network Controller Network Controller Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Storage Controller Storage Controller Storage Controller Storage Controller HP Smart Array P410i/256MB Controller Hard Drive Hard Drive Hard Drive Hard Drive None ship standard Internal Storage Internal Storage Internal Storage Internal Storage (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) Optical Drive Optical Drive Optical Drive Optical Drive SATA DVD ROM PCI-Express Slots PCI-Express Slots PCI-Express Slots PCI-Express Slots 10 slots - (9) available PCI-e Gen2 slots ( NOTE: NOTE: NOTE: NOTE: 10 slots available, one is taken by the NIC riser card ) Power Supply Power Supply Power Supply Power Supply (1) 750W Redundant Hot Plug Power Supply Fans Fans Fans Fans (3) Hot Plug Fans Form Factor Form Factor Form Factor Form Factor 4U Rack HP DL370 G6 HP DL370 G6 HP DL370 G6 HP DL370 G6 Performance Model Performance Model Performance Model Performance Model DL370 E5550 12GB DL370 E5550 12GB DL370 E5550 12GB DL370 E5550 12GB 487790-xx1 Processor(s) Processor(s) Processor(s) Processor(s) (2) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) Cache Memory Cache Memory Cache Memory Cache Memory 8MB (1 x 8MB) Level 3 cache Memory Memory Memory Memory 12 GB (6 x 2 GB) PC3-10600 (DDR3-1333) Registered DIMMs Network Controller Network Controller Network Controller Network Controller HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Storage Controller Storage Controller Storage Controller Storage Controller HP Smart Array P410i/512MB with BBWC Hard Drive Hard Drive Hard Drive Hard Drive None ship standard Internal Storage Internal Storage Internal Storage Internal Storage (8) SFF SAS/SATA HD Bays (Standard); Up to (24) SFF SAS/SATA with optional drive cage (up to three 8 SFF drive cage can be installed) Optical Drive Optical Drive Optical Drive Optical Drive SATA DVD ROM PCI-Express Slots PCI-Express Slots PCI-Express Slots PCI-Express Slots 10 slots - (9) available PCI-e Gen2 slots ( NOTE: NOTE: NOTE: NOTE: 10 slots available, one is taken by the NIC riser card ) Power Supply Power Supply Power Supply Power Supply (2) 750W Redundant Hot Plug Power Supplies Fans Fans Fans Fans (5) Fully Redundant Hot Plug Fans Form Factor Form Factor Form Factor Form Factor 4U Rack QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 19
Country Code Key Country Code Key Country Code Key Country Code Key Tower Code Key Tower Code Key Tower Code Key Tower Code Key Rack Code Key Rack Code Key Rack Code Key Rack Code Key XX=00 U.S. English U.S. English XX=01 Australia N/A XX=03 UK N/A XX=04 Germany N/A XX=05 France N/A XX=20 Brazil Brazil XX=29 Japan Japan XX=37 APD APD XX=42 Europe Europe XX=AA PRC PRC QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 20
NOTE: NOTE: NOTE: NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements. NOTE: NOTE: NOTE: NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis. NOTE: NOTE: NOTE: NOTE: FIO indicates that this option only available as a Factory Installable Option. Step 1: Base Configuration (choose one of the following configurable models) Step 1: Base Configuration (choose one of the following configurable models) Step 1: Base Configuration (choose one of the following configurable models) Step 1: Base Configuration (choose one of the following configurable models) Models Models Models Models HP ProLiant ML370 G6 Tower Models HP ProLiant ML370 G6 Tower Models HP ProLiant ML370 G6 Tower Models HP ProLiant ML370 G6 Tower Models HP ProLiant ML370 G6 SFF CTO Chassis 483880-B21 NOTE: NOTE: NOTE: NOTE: Supports Small Form Factor (SFF) - 2.5" Drives Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Integrated Lights-Out embedded HP Smart Array P410i/Zero Memory Controller (8) Hot-Plug (SFF) SAS/SATA Drive Bays (9) available PCI-e Gen2 slots (5) USB ports (3) Hot Plug Fans Tower Form Factor HP ProLiant ML370 G6 LFF CTO Chassis 483879-B21 NOTE: NOTE: NOTE: NOTE: Supports Large Form Factor (LFF) - 3.5" Drives Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Integrated Lights-Out embedded HP Smart Array P410i/Zero Memory Controller (6) Hot-Plug (LFF) SAS/SATA Drive Bays (9) available PCI-e Gen2 slots (5) USB ports (3) Hot Plug Fans Tower Form Factor HP ProLiant DL370 G6 Rack Models HP ProLiant DL370 G6 Rack Models HP ProLiant DL370 G6 Rack Models HP ProLiant DL370 G6 Rack Models HP ProLiant DL370 G6 SFF CTO Chassis 483874-B21 NOTE: NOTE: NOTE: NOTE: Supports Small Form Factor (SFF) - 2.5" Drives Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter Integrated Lights-Out embedded HP Smart Array P410i/Zero Memory Controller (8) Hot-Plug (SFF) SAS/SATA Drive Bays (9) available PCI-e Gen2 slots (5) USB ports (3) Hot Plug Fans 4U Rack Form Factor HP ProLiant DL370 G6 LFF CTO Chassis 483873-B21 NOTE: NOTE: NOTE: NOTE: Supports Large Form Factor (LFF) - 3.5" Drives Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: Factory Integrated Model ships with: HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Configuration Information - Factory Integrated Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 21
Integrated Lights-Out embedded HP Smart Array P410i/Zero Memory Controller (6) Hot-Plug (LFF) SAS/SATA Drive Bays (9) available PCI-e Gen2 slots (5) USB ports (3) Hot Plug Fans 4U Rack Form Factor Step 2: Choose Required Options (only one of the following from each list) Step 2: Choose Required Options (only one of the following from each list) Step 2: Choose Required Options (only one of the following from each list) Step 2: Choose Required Options (only one of the following from each list) Processors Processors Processors Processors NOTE: NOTE: NOTE: NOTE: If High Performance Model features are desired, 2nd processor is included in the Performance Pack part numbers in Step 3 below. Quad-Core Processors Quad-Core Processors Quad-Core Processors Quad-Core Processors Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO 495930-L21 Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO 495932-L21 Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO 495934-L21 Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO 495936-L21 Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO 495938-L21 Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO 495940-L21 Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO 495942-L21 Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO 495944-L21 Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO 505511-L21 Dual-Core Processors Dual-Core Processors Dual-Core Processors Dual-Core Processors Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO 495946-L21 Base Memory Base Memory Base Memory Base Memory Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) HP 2GB 2Rx8 PC3-10600R-9 Kit 500656-B21 HP 4GB 2Rx4 PC3-10600R-9 Kit 500658-B21 HP 4GB 4Rx8 PC3-8500R-7 LP Kit 500660-B21 HP 8GB 2Rx4 PC3-8500R-7 Kit 516423-B21 Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) HP 1GB 1Rx8 PC3-10600E-9 Kit 500668-B21 HP 2GB 2Rx8 PC3-10600E-9 Kit 500670-B21 NOTE: NOTE: NOTE: NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator . NOTE: NOTE: NOTE: NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/ Power Supply Power Supply Power Supply Power Supply NOTE: NOTE: NOTE: NOTE: Refer to HP Power Advisor when selecting a power supply for your QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Configuration Information - Factory Integrated Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 22
configuration, www.hp.co/go/hppoweradvisor . Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at " www.hp.com/go/proliant-energy-efficient " or www.hp.com/go/hppoweradvisor HP 460W CS HE Power Supply Kit 503296-B21 HP 750W CS HE Power Supply Kit 512327-B21 HP 1200W CS HE Power Supply Kit 500172-B21 NOTE: NOTE: NOTE: NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. Step 3: Choose Additional Factory Integratable Options Step 3: Choose Additional Factory Integratable Options Step 3: Choose Additional Factory Integratable Options Step 3: Choose Additional Factory Integratable Options Controllers Controllers Controllers Controllers NOTE: NOTE: NOTE: NOTE: If Additional Memory Cache Module or Controller is Required please pick one of the following: HP 256 MB P-series cache module FIO NOTE: NOTE: NOTE: NOTE: Available for P410i only. 534108-B21 512MB BBWC 462967-B21 HP Smart Array P212/256 MB w/ Battery FIO 491191-B21 HP Smart Array P410/256 MB w/ Battery FIO 491195-B21 HP Smart Array P411/256 MB w/ Battery FIO 491193-B21 Integrated hypervisor Integrated hypervisor Integrated hypervisor Integrated hypervisor (iHV) NOTE: NOTE: NOTE: NOTE: HP VMware ESXi free download from www.software.hp.com - select Virtualization HP VMware 3i Enterprise 2p Lic SW NOTE: NOTE: NOTE: NOTE: For additional information and options kits, please see the QuickSpecs at: www.hp.com/go/vmware . NOTE: NOTE: NOTE: NOTE: HP XenServer Select Edition free download from: http://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do? productNumber=HPXS 430341-B21 HP Essentials -XenServer Platinum Nm Lic 530753-B21 HP ProLiant Virtual Console Full License 508293-B21 XenServer HP Ent Upg iSW Lic 464676-B21 Citrix Essentials for XenServer Enterprise Edition NOTE: NOTE: NOTE: NOTE: For additional information and options kits, please see the Citrix Essentials for XenServer QuickSpecs at www.hp.com/go/citrix 508294-B21 Performance Packs Performance Packs Performance Packs Performance Packs Performance Packs are necessary to configure a HP ProLiant DL370 G6 or a HP ProLiant ML370 G6 to a High Performance Model which includes the latest performance technologies and enterprise class availability features pre-installed for convenience and value. The Performance Pack includes a 2nd processor, redundant fans, power supply, and memory expansion board. NOTE: NOTE: NOTE: NOTE: Must also select 447326-B21 to achieve parity to DL370 G6 or ML370 G6 High Performance Models. HP DL370 G6 and ML370 G6 X5550 HPM FIO Perf Kit 516727-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Configuration Information - Factory Integrated Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 23
Step 4: Choose Additional Options for Factory Integration Step 4: Choose Additional Options for Factory Integration Step 4: Choose Additional Options for Factory Integration Step 4: Choose Additional Options for Factory Integration NOTE: NOTE: NOTE: NOTE: For additional options, please refer to the "Core Options" and "Additional Options" section below. QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Configuration Information - Factory Integrated Models DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 24
NOTE: NOTE: NOTE: NOTE: Some options may not be factory configurable. Please contact your local sales representative for additional information. HP ProLiant ML370 and HP ProLiant ML370 and HP ProLiant ML370 and HP ProLiant ML370 and DL370 G6 Unique DL370 G6 Unique DL370 G6 Unique DL370 G6 Unique Options Options Options Options (8) Small Form Factor (SFF) 2nd Drive Cage Kit 507803-B21 (6) Large Form Factor (LFF) Backplane Kit 507810-B21 (2) Large Form Factor (LFF) Drive Cage Kit 487936-B21 HP ML370 G6 Tower to Rack Conversion Kit 515031-B21 HP ML and DL 370G6 Redundant Fan Kit 508107-B21 Processors Processors Processors Processors Quad-Core Processors Quad-Core Processors Quad-Core Processors Quad-Core Processors Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) 495930-B21 Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) 495932-B21 Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) 495934-B21 Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) 495936-B21 Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) 495938-B21 Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) 495940-B21 Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) 495942-B21 Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) 495944-B21 Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) 505511-B21 Dual-Core Processors Dual-Core Processors Dual-Core Processors Dual-Core Processors Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) 495946-B21 Memory Memory Memory Memory Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) HP 2GB 2Rx8 PC3-10600R-9 Kit 500656-B21 HP 4GB 2Rx4 PC3-10600R-9 Kit 500658-B21 HP 4GB 4Rx8 PC3-8500R-7 LP Kit 500660-B21 HP 8GB 2Rx4 PC3-8500R-7 Kit 516423-B21 Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) HP 1GB 1Rx8 PC3-10600E-9 Kit 500668-B21 HP 2GB 2Rx8 PC3-10600E-9 Kit 500670-B21 NOTE: NOTE: NOTE: NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator NOTE: NOTE: NOTE: NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/ QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Core Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 25
Optical Drives Optical Drives Optical Drives Optical Drives HP Half-Height SATA DVD-ROM Optical Drive 447326-B21 HP Half-Height SATA DVD RW Optical Drive 447328-B21 HP Slim SATA DVD RW Optical Drive 481043-B21 HP Slim SATA DVD-ROM Optical Drive 481041-B21 Hard Drives Hard Drives Hard Drives Hard Drives NOTE: NOTE: NOTE: NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details. SAS Hot Plug SFF Enterprise (ENT) Drives SAS Hot Plug SFF Enterprise (ENT) Drives SAS Hot Plug SFF Enterprise (ENT) Drives SAS Hot Plug SFF Enterprise (ENT) Drives NOTE: NOTE: NOTE: NOTE: Please note that SFF 2.5" (small form factor) drives can only be installed on tower or rack models with SFF chassis (models). HP 300GB 6G SAS 10K SFF DP ENT HDD 507127-B21 HP 300GB 3G SAS 10K SFF DP ENT HDD 492620-B21 HP 146GB 6G SAS 10K SFF DP ENT HDD 507125-B21 HP 146GB 3G SAS 10K SFF DP ENT HDD 418367-B21 HP 146GB 3G SAS 15K SFF DP ENT HDD 504062-B21 HP 72GB 3G SAS 15K SFF DP ENT HDD 418371-B21 HP 72GB 3G SAS 10K SFF DP ENT HDD 384842-B21 HP 36GB 3G SAS 15K SFF DP ENT HDD 418369-B21 NOTE: NOTE: NOTE: NOTE: SAS Enterprise drives have a 3 year warranty. Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.html (Worldwide) SAS Hot Plug 3.5" Enterprise (ENT) Drives SAS Hot Plug 3.5" Enterprise (ENT) Drives SAS Hot Plug 3.5" Enterprise (ENT) Drives SAS Hot Plug 3.5" Enterprise (ENT) Drives HP 450GB 3G SAS 15K 3.5" DP ENT HDD 454232-B21 HP 400GB 3G SAS 10K 3.5" DP ENT HDD 459508-B21 HP 146GB 3G SAS 15K 3.5" DP ENT HDD 384854-B21 HP 72GB 3G SAS 15K 3.5" DP ENT HDD 384852-B21 SAS Hot Plug 3.5" Midline (MDL) Drives SAS Hot Plug 3.5" Midline (MDL) Drives SAS Hot Plug 3.5" Midline (MDL) Drives SAS Hot Plug 3.5" Midline (MDL) Drives NOTE: NOTE: NOTE: NOTE: Please note that LFF 3.5" (large form factor) drives can only be installed on tower or rack models with LFF chassis (models). HP 1TB 3G SAS 7.2K DP MDL HDD 461137-B21 HP 750GB 3G SAS 7.2K DP MDL HDD 461135-B21 SATA Hot Plug SFF Entry (ETY) Drives SATA Hot Plug SFF Entry (ETY) Drives SATA Hot Plug SFF Entry (ETY) Drives SATA Hot Plug SFF Entry (ETY) Drives NOTE: NOTE: NOTE: NOTE: Please note that SFF 2.5" (small form factor) drives can only be installed on tower or rack models with SFF chassis (models). HP 250GB 3G SATA 5.4K SFF ETY HDD 460355-B21 HP 120GB 1.5G SATA 5.4K SFF ETY HDD 458924-B21 NOTE: NOTE: NOTE: NOTE: SATA hard drives have a 1-year warranty. Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html (Worldwide) SATA Hot Plug 3.5" Midline (MDL) Drives SATA Hot Plug 3.5" Midline (MDL) Drives SATA Hot Plug 3.5" Midline (MDL) Drives SATA Hot Plug 3.5" Midline (MDL) Drives HP 1TB 3G SATA 7.2K 3.5" MDL HDD 454146-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Core Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 26
HP 750GB 3G SATA 7.2K 3.5" MDL HDD 458930-B21 HP 500GB 3G SATA 7.2K 3.5" MDL HDD 458928-B21 HP 250GB 3G SATA 7.2K 3.5" MDL HDD 458926-B21 NOTE: NOTE: NOTE: NOTE: SATA hard drives have a 1-year warranty. Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html (Worldwide) Communications Communications Communications Communications HP NC112T PCIe Gigabit Server Adapter 503746-B21 HP NC360T PCI Express Dual Port Gigabit Server Adapter 412648-B21 HP NC364T PCI Express Quad Port Gigabit Server Adapter NOTE: NOTE: NOTE: NOTE: There is a maximum of five NC364T PCI Express Quad Port Gigabit Server Adapters allowed in this server. 435508-B21 HP NC373F PCI Express Multifunction Gigabit Server Adapter 394793-B21 HP NC373T PCI Express Multifunction Gigabit Server Adapter 394791-B21 HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter 458492-B21 HP NC522SFP Dual Port 10GbE Server Adapter NOTE: NOTE: NOTE: NOTE: A minimum of two gigabyte (2 GB) of server memory is required per each NC522SFP adapter. 468332-B21 HP NC524SFP Dual Port 10GbE Module 489892-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs . Redundant Options Redundant Options Redundant Options Redundant Options CAUTION: CAUTION: CAUTION: CAUTION: Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at www.hp.com/go/proliant-energy- efficient . In ProLiant Servers that have more than one power slot (bay), only same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail. HP 460W CS HE Power Supply Kit 503296-B21 HP 750W CS HE Power Supply Kit 512327-B21 HP 1200W CS HE Power Supply Kit 500172-B21 NOTE: NOTE: NOTE: NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. HP ML and DL 370G6 Redundant Fan Kit 508107-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Core Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 27
HP Insight Control Suite HP Insight Control Suite HP Insight Control Suite HP Insight Control Suite NOTE: NOTE: NOTE: NOTE: Electronic licensing options are available for Insight Control suites software products. Please see the appropriate Insight Control QuickSpecs for additional information. www.hp.com/go/ice HP Insight Control suite HP Insight Control suite HP Insight Control suite HP Insight Control suite HP Insight Control suite, No Media 1-Server License including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This part number can be purchased as a single license or as multiple licenses with a single activation key. Customer will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. Only available directly from HP and select resellers in the Americas region. 452148-B22 HP Insight Software Media Kit NOTE: NOTE: NOTE: NOTE: Insight Software DVD media without licenses. Contains Insight Manager and Insight Software products and components licensed by Insight Control suite. Uses an integrated installer to perform quick and accurate software installation and updates. 436222-B21 NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12631_div/12631_div.html HP Insight Control Linux Edition HP Insight Control Linux Edition HP Insight Control Linux Edition HP Insight Control Linux Edition HP Insight Control Environment for Linux, Media pack (DVD) - No licenses included NOTE: NOTE: NOTE: NOTE: This optional Media pack DVD contains the ISO image for HP Insight Control Environment for Linux, HP System Insight Manager, HP Insight Power Manager, HP Virtual Machine Management Pack, and an integrated installer. Servers must be acquired separately. NOTE: NOTE: NOTE: NOTE: This Media pack is optional because the latest ISO image and latest updates may be downloaded at no cost from: http://www.hp.com/go/ice-linux (click on Download button). 464422-B22 HP Insight Control Environment for Linux, No Media, 1-Server license, including one year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This part number can be used to purchase one (1) license with a single activation key. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: NOTE: NOTE: NOTE: One certificate is shipped for each license. 464423-B22 NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_div/13019_div.html Server Management Server Management Server Management Server Management Stand Alone Software Stand Alone Software Stand Alone Software Stand Alone Software NOTE: NOTE: NOTE: NOTE: Electronic licensing options are available for select software products. Please see the appropriate Insight Software standalone product QuickSpecs for additional information. Deploy Deploy Deploy Deploy HP Insight Rapid Deployment software HP Insight Rapid Deployment software HP Insight Rapid Deployment software HP Insight Rapid Deployment software HP Insight Rapid Deployment software No Media 1-Server License including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This license allows 1 server to be deployed and managed via RDP. Customer will receive a printed license entitlement certificate via physical shipment. The license 452151-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 28
entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html HP Insight Server Migration software for ProLiant HP Insight Server Migration software for ProLiant HP Insight Server Migration software for ProLiant HP Insight Server Migration software for ProLiant HP Insight Server Migration software for ProLiant, No Media, Physical / Virtual to ProLiant Single Migration License, including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This license allows 1 physical to ProLiant or virtual to ProLiant migration. Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. 460750-B21 HP Insight Server Migration software for ProLiant, No Media, Physical / Virtual to Virtual Single Migration License, including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This license allows 1 physical to virtual or virtual to virtual migration. Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. 460753-B21 HP Insight Server Migration software for ProLiant, No Media, 1-Year Unlimited Migration License, including 1 year of 24x7 Technical Support NOTE: NOTE: NOTE: NOTE: This license allows unlimited migrations (physical to ProLiant, physical to virtual, virtual to virtual, and virtual to ProLiant) for one year. Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. 460756-B21 NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12855_div/12855_div.html Monitor Monitor Monitor Monitor HP Insight Dynamics-VSE suite for ProLiant HP Insight Dynamics-VSE suite for ProLiant HP Insight Dynamics-VSE suite for ProLiant HP Insight Dynamics-VSE suite for ProLiant HP Insight Dynamics-VSE with Insight Control Environment, 1-server license including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This license supports HP ProLiant ML/DL and c-Class Blade servers. Customer will receive a printed license entitlement certificate via physical shipment. 483527-B21 HP Insight Dynamics-VSE without Insight Control Environment, 1-server license including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: This license supports HP ProLiant ML/DL and c-Class Blade servers. Customer will receive via email a receipt and link to a license entitlement certificate. 483531-B21 NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13050_div/13050_div.html Control Control Control Control HP Integrated Lights-Out Select Pack HP Integrated Lights-Out Select Pack HP Integrated Lights-Out Select Pack HP Integrated Lights-Out Select Pack HP Integrated Lights-Out Select Pack, No Media, 1-Server License NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_div/12362_div.html 452158-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 29
HP Integrated Lights-Out Advanced Pack HP Integrated Lights-Out Advanced Pack HP Integrated Lights-Out Advanced Pack HP Integrated Lights-Out Advanced Pack HP Integrated Lights-Out Advanced Pack, No Media, 1-Server License, including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_div/12362_div.html 512485-B21 Optimize Optimize Optimize Optimize HP Accelerated iSCSI Pack HP Accelerated iSCSI Pack HP Accelerated iSCSI Pack HP Accelerated iSCSI Pack HP Accelerated iSCSI Pack, No Media, Single License NOTE: NOTE: NOTE: NOTE: For use with a single NIC port. Contains one license with a unique license activation key and documentation. NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12466_div/12466_div.html 452679-B21 HP Insight Power Manager (IPM) HP Insight Power Manager (IPM) HP Insight Power Manager (IPM) HP Insight Power Manager (IPM) HP Insight Power Manager software, No Media, 1-Server License, including 1 year of 24x7 Technical Support and Updates NOTE: NOTE: NOTE: NOTE: Customers purchasing this upgrade must already have an iLO Advanced or Select license on each managed server. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: NOTE: NOTE: NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12623_div/12623_div.html 452677-B21 NOTE: NOTE: NOTE: NOTE: Flexible and volume quantity license kits are available for Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various QuickSpecs for more information. Drive Cage Options Drive Cage Options Drive Cage Options Drive Cage Options (8) Small Form Factor (SFF) 2nd Drive Cage Kit 507803-B21 (6) Large Form Factor (LFF) Backplane Kit 507810-B21 (2) Large Form Factor (LFF) Drive Cage Kit 487936-B21 Security Security Security Security HP Trusted Platform Module Option Kit 488069-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 30
Storage Controllers Storage Controllers Storage Controllers Storage Controllers SAS Controllers SAS Controllers SAS Controllers SAS Controllers Smart Array P800 Controller Smart Array P800 Controller Smart Array P800 Controller Smart Array P800 Controller HP Smart Array P800/512 BBWC Controller 381513-B21 Smart Array P212 Controller Smart Array P212 Controller Smart Array P212 Controller Smart Array P212 Controller HP Smart Array P212/ZM Controller 462828-B21 HP Smart Array P212/256 MB Controller 462834-B21 256 MB Cache 462968-B21 Smart Array P410 Controller Smart Array P410 Controller Smart Array P410 Controller Smart Array P410 Controller HP Smart Array P410/256 MB Controller 462862-B21 HP Smart Array P410/512 MB with BBWC Controller 462864-B21 512MB BBWC 462967-B21 Smart Array P411 Controller Smart Array P411 Controller Smart Array P411 Controller Smart Array P411 Controller HP Smart Array P411/256 MB Controller 462830-B21 HP Smart Array P411/512 MB with BBWC Controller 462832-B21 512MB BBWC 462967-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12616_div/12616_div.html (Smart Array P800 Controller) http://h18000.www1.hp.com/products/quickspecs/13203_div/13203_div.html (Smart Array P212 Controller) http://h18000.www1.hp.com/products/quickspecs/13201_div/13201_div.html (Smart Array P410 Controller) http://h18000.www1.hp.com/products/quickspecs/13202_div/13202_div.html (Smart Array P411 Controller) SAS Controller Options SAS Controller Options SAS Controller Options SAS Controller Options HP SAS Expander Card NOTE: NOTE: NOTE: NOTE: For use with the additional 8 SFF drive cage (507803-B21). 468406-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/13232_div/13232_div.html (SAS Expander Card) SAS HBA SAS HBA SAS HBA SAS HBA HP SC08Ge Host Bus Adapter 488765-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/13082_div/13082_div.html (SC08Ge HBA) QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 31
Power Cords Power Cords Power Cords Power Cords NOTE: NOTE: NOTE: NOTE: HP ProLiant servers ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). Nema 5-15P to IEC320-C13, North America low voltage (6 ft/2 m) AF556A Power Cord, Euro, 10A 250 V Straight (6 ft/1.83 m) AF568A Power Cord, UK, 10A 250 V Straight (6 ft/1.83 m) AF570A Power Cord, Danish, 10A 250 V Straight (6 ft/1.83 m) AF566A Power Cord, Swiss, 10A 250 V Straight (6 ft/1.83 m) AF565A Power Cord, Italian, 10A 250 V Straight (6 ft/1.83 m) AF571A Power Cord, South Africa, 10A 250 V Straight (8.2 ft/2.5 m) AF567A Tape Drives Tape Drives Tape Drives Tape Drives NOTE: NOTE: NOTE: NOTE: For the complete listing of Tape Drive offerings, please see: http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html For recommended tape drive offerings for this ProLiant server see the following: USB Tape Drives USB Tape Drives USB Tape Drives USB Tape Drives HP StorageWorks DAT 160 USB Internal Tape Drive Q1580A SAS Tape Drives SAS Tape Drives SAS Tape Drives SAS Tape Drives NOTE: NOTE: NOTE: NOTE: For the ML370 G6, HP recommends purchasing the HP Smart Array P212 Controller (462828-B21) for a dedicated SAS HBA for tape. HP StorageWorks LTO-2 Ultrium 448 SAS Internal Tape Drive DW085A HP StorageWorks LTO-3 Ultrium 920 SAS Internal Tape Drive EH847A HP StorageWorks LTO-4 Ultrium 1760 SAS Internal Tape Drive EH919A NOTE: NOTE: NOTE: NOTE: Please refer to the "Tape Drives, Tape Autoloaders & Tape Libraries" table in the Storage section of this document for a list of SAS controllers with tape support. Disk-Based Backup Disk-Based Backup Disk-Based Backup Disk-Based Backup RDX Removable Disk Backup RDX Removable Disk Backup RDX Removable Disk Backup RDX Removable Disk Backup HP StorageWorks RDX500 Internal Removable Disk Backup System NOTE: NOTE: NOTE: NOTE: 500GB of Disk Storage. AJ934A D2D Backup D2D Backup D2D Backup D2D Backup HP StorageWorks D2D120 Backup System with Data Protector Express Software Kit NOTE: NOTE: NOTE: NOTE: 2TB of Disk Storage EH924A HP StorageWorks D2D130 Backup System with LTO-3 Ultrium 920 SAS Tape Drive NOTE: NOTE: NOTE: NOTE: 3TB of Disk Storage. EH952A HP StorageWorks D2D2503i Backup System NOTE: NOTE: NOTE: NOTE: 3TB of Disk Storage. EH945A HP StorageWorks D2D4004i Backup System NOTE: NOTE: NOTE: NOTE: 4.5TB of Disk Storage. EH938A NOTE: NOTE: NOTE: NOTE: Please see the HP D2D Backup Systems QuickSpecs for additional information: http://www.hp.com/go/d2d QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 32
Tape Autoloaders Tape Autoloaders Tape Autoloaders Tape Autoloaders HP StorageWorks 1/8 G2 Tape Autoloader HP StorageWorks 1/8 G2 Tape Autoloader HP StorageWorks 1/8 G2 Tape Autoloader HP StorageWorks 1/8 G2 Tape Autoloader HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader AK377A HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader AH558A HP StorageWorks 1/8 G2 Tape Autoloader Rack Kit NOTE: NOTE: NOTE: NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions. AH166A NOTE: NOTE: NOTE: NOTE: Please reference the Tape Autoloader QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs Tape Libraries Tape Libraries Tape Libraries Tape Libraries HP StorageWorks MSL2024 Tape Library HP StorageWorks MSL2024 Tape Library HP StorageWorks MSL2024 Tape Library HP StorageWorks MSL2024 Tape Library HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Drive Library AK378A HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SAS Drive Library AH559A HP StorageWorks MSL4048 Tape Library HP StorageWorks MSL4048 Tape Library HP StorageWorks MSL4048 Tape Library HP StorageWorks MSL4048 Tape Library HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SAS Drive Library AK380A HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SAS Drive Library AH560A NOTE: NOTE: NOTE: NOTE: Please reference the MSL Tape Library QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs . High Availability Cluster High Availability Cluster High Availability Cluster High Availability Cluster Options Options Options Options HP Serviceguard for Linux HP Serviceguard for Linux HP Serviceguard for Linux HP Serviceguard for Linux HP Serviceguard Linux for HP ProLiant/x86 Servers Licensed per physical server Includes media and One Year 24x7 Software Support & Updates 463831-B21 HP Serviceguard Linux Oracle Database Toolkit for HP ProLiant/x86 Servers Licensed per cluster Includes media and One Year 24x7 Software Support & Updates 463833-B21 HP Serviceguard Extension for SAP on Linux for HP ProLiant/x86 Servers Licensed per physical server Includes media and One Year 24x7 Software Support & Updates 463834-B21 HP Serviceguard Linux Extended Distance Cluster (XDC) for HP ProLiant/x86 Servers Licensed per physical server Includes media and One Year 24x7 Software Support & Updates 463835-B21 NOTE: NOTE: NOTE: NOTE: The above is not a complete list of all HP Serviceguard for Linux product numbers For a detailed list of supported configuration/certification options for HP Serviceguard for Linux please refer to the HP Serviceguard for Linux Configuration & Ordering Guide available at: http://www.hp.com/go/sglx/info . NOTE: NOTE: NOTE: NOTE: HP Serviceguard for Linux products running on x86 platforms now include one year of 24 x 7 Software Technical Support and Updates. Please see the Support Information section of the HP Serviceguard for Linux QuickSpecs for details. NOTE: NOTE: NOTE: NOTE: For additional information including a complete list of Product Numbers for HP Serviceguard for Linux, please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html (Worldwide) QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 33
StorageWorks Options StorageWorks Options StorageWorks Options StorageWorks Options StorageWorks Fibre Channel HBA StorageWorks Fibre Channel HBA StorageWorks Fibre Channel HBA StorageWorks Fibre Channel HBA NOTE: NOTE: NOTE: NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html HP StorageWorks FC2142SR 4Gb PCI-e HBA A8002A HP StorageWorks FC2242SR Dual Channel 4Gb PCI-e HBA A8003A HP StorageWorks FC1142SR 4Gb PCI-e HBA AE311A HP StorageWorks FC1242SR Dual Channel 4Gb PCI-e HBA AE312A HP StorageWorks 81Q PCI-e FC HBA AK344A HP StorageWorks 81E 8Gb PCI-e FC HBA AJ762A HP StorageWorks 82E 8Gb Dual-port PCI-e FC HBA AJ763A HP StorageWorks 82Q 8Gb Dual Port PCI-e FC HBA AJ764A StorageWorks SCSI HBA StorageWorks SCSI HBA StorageWorks SCSI HBA StorageWorks SCSI HBA HP U320e SCSI Host Bus Adapter NOTE: NOTE: NOTE: NOTE: Recommended Dual Channel Ultra320 SCSI Controller for connecting multi- drive MSL tape libraries to ProLiant servers. AH627A HP StorageWorks 50 HP StorageWorks 50 HP StorageWorks 50 HP StorageWorks 50 Modular Smart Array Modular Smart Array Modular Smart Array Modular Smart Array HP StorageWorks 50 Modular Smart Array 364430-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12245_div/12245_div.html (Worldwide) HP StorageWorks 60 HP StorageWorks 60 HP StorageWorks 60 HP StorageWorks 60 Modular Smart Array Modular Smart Array Modular Smart Array Modular Smart Array HP StorageWorks 60 Modular Smart Array 418408-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12627_div/12627_div.html (Worldwide) HP StorageWorks 70 HP StorageWorks 70 HP StorageWorks 70 HP StorageWorks 70 Modular Smart Array Modular Smart Array Modular Smart Array Modular Smart Array HP StorageWorks 70 Modular Smart Array 418800-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12652_div/12652_div.html (Worldwide) QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 34
Uninterruptible Power Uninterruptible Power Uninterruptible Power Uninterruptible Power Systems - Tower Systems - Tower Systems - Tower Systems - Tower HP T1000v Uninterruptible Power System HP T1000v Uninterruptible Power System HP T1000v Uninterruptible Power System HP T1000v Uninterruptible Power System HP T1000v UPS NOTE: NOTE: NOTE: NOTE: The T1000v is available in China and India only. AF443A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13130_div/13130_div.html (Worldwide) HP T1500 G3 UPS Models HP T1500 G3 UPS Models HP T1500 G3 UPS Models HP T1500 G3 UPS Models HP T1500 G3 UPS, NA AF450A HP T1500 G3 UPS, INTL AF451A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13160_div/13160_div.html (Worldwide) Uninterruptible Power Uninterruptible Power Uninterruptible Power Uninterruptible Power Systems - Rack Systems - Rack Systems - Rack Systems - Rack HP R1500 G2 UPS HP R1500 G2 UPS HP R1500 G2 UPS HP R1500 G2 UPS HP, R1.5kVA UPS, 1U, NA AF419A HP, R1.5kVA UPS, 1U, INTL AF418A HP, R1.5kVA UPS, 1U, JPN/TW AF421A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12507_div/12507_div.html (Worldwide) HP R3000 UPS HP R3000 UPS HP R3000 UPS HP R3000 UPS HP R3000 VA UPS, 2U, DTC, INTL AF414A HP R3000 VA UPS, 2U, L5-30, NA AF422A HP R3000 VA UPS, 2U, L6-20, NA AF423A HP R3000 VA UPS, 2U, L6-20, JPN AF424A HP R3000 VA UPS, 2U, L5-30, JPN AF425A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/10671_div/10671_div.html (Worldwide) HP R3000v Uninterruptible Power System HP R3000v Uninterruptible Power System HP R3000v Uninterruptible Power System HP R3000v Uninterruptible Power System HP R3000v UPS NOTE: NOTE: NOTE: NOTE: The R3000v is available in China and India only. AF444A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13129_div/13129_div.html (Worldwide) HP Rack-Mountable R5500 UPS HP Rack-Mountable R5500 UPS HP Rack-Mountable R5500 UPS HP Rack-Mountable R5500 UPS HP R5500 VA UPS, INTL AF416A HP R5500 VA UPS, NA/JPN AF426A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/11871_div/11871_div.html (Worldwide) QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 35
HP Monitored Power HP Monitored Power HP Monitored Power HP Monitored Power Distribution Unit Distribution Unit Distribution Unit Distribution Unit (PDU) HP Monitored Power Distribution Unit: Full Rack Version HP Monitored Power Distribution Unit: Full Rack Version HP Monitored Power Distribution Unit: Full Rack Version HP Monitored Power Distribution Unit: Full Rack Version HP 17.3 kVA S2324 Monitored PDU- dual input, 3Ã24A (NA/JPN) AF503A HP 8.6 kVA S1324 Monitored PDU- single input, 3Ã, 24A (NA/JPN) AF504A HP 16.6 kVA S2140 Monitored PDU- dual input, 1Ã, 40A (NA/JPN) AF505A HP 8.3 S1140 Monitored PDU- single input, 1Ã, 40A (NA/JPN) AF506A HP 22.1 kVA S2316 Monitored PDU- dual input, 3Ã, 16A (INTL) AF507A HP 11 kVA S1316 Monitored PDU- single input, 3Ã, 16A (INTL) AF508A HP 14.7 kVA S2132 Monitored PDU- dual input, 1Ã, 32A (INTL) AF509A HP 7.3 kVA S1132 Monitored PDU- single input, 1Ã, 32A (INTL) AF510A HP Monitored Power Distribution Unit: Half Rack Version HP Monitored Power Distribution Unit: Half Rack Version HP Monitored Power Distribution Unit: Half Rack Version HP Monitored Power Distribution Unit: Half Rack Version HP 4.9 kVA S124 Monitored PDU- single input, 1Ã, 24A (NA/JPN) AF914A HP 7.3 kVA S132 Monitored PDU- single input, 1Ã, 32A (INTL) AF915A NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12118_div/12118_div.html (Worldwide) Modular PDUs 1U/0U Modular PDUs 1U/0U Modular PDUs 1U/0U Modular PDUs 1U/0U (Up to 32 outlets) NOTE: NOTE: NOTE: NOTE: 1U/0U mounting brackets shipped with the unit (optimized for 10000 and 9000 series racks). Fixed Cord Extension Bars NOTE: NOTE: NOTE: NOTE: Two extension bar sticks; each with (7) C13 plugs. 351655-B21 3.6kVA Model - mPDU, 16A, High (WW) 252663-B24 2.8 kVA Model - mPDU, 24A, Low (NA/JPN) 252663-D71 4.9kVA Model - mPDU, 24A, High (NA/JPN) 252663-D72 7.3kVA Model - mPDU, 32A, High (INT'L) 252663-B31 8.3kVA Model - mPDU, 40A, High (WW) 252663-B21 8.3kVA Model - mPDU, 40A, High (power cord attached) (NA/JPN) 252663-D73 9.2kVA Model - mPDU, 40A, High (power cord attached) (INTL) 252663-B32 NOTE: NOTE: NOTE: NOTE: For additional information on HP Power Distribution Units including accessories please go to: www.hp.com/go/pdu (Worldwide) USB Options USB Options USB Options USB Options HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) DC172B USB 1.44-MB External Diskette Drive (Carbonite) DC141B HP USB 04 Standard Keyboard DT528A#ABA Rack Kit Rack Kit Rack Kit Rack Kit HP ML370 G6 Tower to Rack Conversion Kit 515031-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 36
HP Rack 5000 Series HP Rack 5000 Series HP Rack 5000 Series HP Rack 5000 Series (Graphite Metallic) HP 5642 Rack Unassembled 358254-B21 NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12074_div/12074_div.html (Worldwide) NOTE: NOTE: NOTE: NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower . HP Rack 10000 G2 HP Rack 10000 G2 HP Rack 10000 G2 HP Rack 10000 G2 Series Series Series Series (Carbon/Graphite Metallic) 10642 G2 (42U) Rack Cabinet - Pallet AF001A 10642 G2 (42U) Rack Cabinet - Shock Pallet AF002A 10642 G2 (42U) Rack Cabinet - Crated AF003A 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet AF004A 10636 G2 (36U) Rack Cabinet - Pallet AF011A 10636 G2 (36U) Rack Cabinet - Shock Pallet AF012A 10636 G2 (36U) Rack Cabinet - Crated AF013A 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet AF014A 10622 G2 (22U) Rack Cabinet - Pallet AF021A 10622 G2 (22U) Rack Cabinet - Shock Pallet AF022A 10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock Pallet AF034A 10642 G2 (42U) Rack Cabinet 1200mm Deep - Pallet AF038A 10842 G2 (42U) 800mm Wide Rack Cabinet - Pallet AF041A 10842 G2 (42U) 800mm Wide Rack Cabinet - Shock Pallet AF042A 10647 G2 (47U) Rack Cabinet - Pallet AF031A HP Rack S10614 (14U) Rack Cabinet - Shock Pallet 292302-B22 10647 G2 (47U) Rack Cabinet 1200mm Deep - Shock Pallet NOTE: NOTE: NOTE: NOTE: Due to handling and shipping requirements, AF044A is only orderable through HP Factory Express. It is not for direct sales. Customer site surveys are required before an order is approved. CTO orders may require additional lead time. AF044A 10647 G2 (47U) Rack Cabinet 1200mm Deep - Pallet AF045A NOTE: NOTE: NOTE: NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed. NOTE: NOTE: NOTE: NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). NOTE: NOTE: NOTE: NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html (Worldwide) NOTE: NOTE: NOTE: NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower . QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 37
Keyboards and Monitors Keyboards and Monitors Keyboards and Monitors Keyboards and Monitors TFT7600 Rackmount Keyboard Monitor US AG052A TFT7600 Rackmount Keyboard Monitor UK AG053A TFT7600 Rackmount Keyboard Monitor GR AG054A TFT7600 Rackmount Keyboard Monitor FR AG055A TFT7600 Rackmount Keyboard Monitor IT AG056A TFT7600 Rackmount Keyboard Monitor SP AG057A TFT7600 Rackmount Keyboard Monitor DEN AG058A TFT7600 Rackmount Keyboard Monitor NOR AG059A TFT7600 Rackmount Keyboard Monitor SE/FI AG060A TFT7600 Rackmount Keyboard Monitor SWI AG061A TFT7600 Rackmount Keyboard Monitor PORT AG062A TFT7600 Rackmount Keyboard Monitor BEL AG063A TFT7600 Rackmount Keyboard Monitor JPN2 AG064A TFT7600 Rackmount Keyboard Monitor RUS AG065A TFT7600 Rackmount Keyboard Monitor INTL AG066A 1U Rackmount Keyboard with USB, US AG072A 1U Rackmount Keyboard with USB, UK AG073A 1U Rackmount Keyboard with USB, GR AG074A 1U Rackmount Keyboard with USB, FR AG075A 1U Rackmount Keyboard with USB, ITL AG076A 1U Rackmount Keyboard with USB, SP AG077A 1U Rackmount Keyboard with USB, DEN AG078A 1U Rackmount Keyboard with USB, NOR AG079A 1U Rackmount Keyboard with USB, SE/FI AG080A 1U Rackmount Keyboard with USB, SWI AG081A 1U Rackmount Keyboard with USB, PORT AG082A 1U Rackmount Keyboard with USB, BEL AG083A 1U Rackmount Keyboard with USB, JPN2 AG084A 1U Rackmount Keyboard with USB, RUS AG085A 1U Rackmount Keyboard with USB, INTL AG086A NOTE: NOTE: NOTE: NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower . QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 38
HP KVM Switch Options HP KVM Switch Options HP KVM Switch Options HP KVM Switch Options 2x1x16 IP Console Switch with Virtual Media AF601A 4x1x16 IP Console Switch with Virtual Media AF602A 2x16 Server Console Switch with Virtual Media AF600A PS/2 Virtual Media Interface Adapter, 1 pack NOTE: NOTE: NOTE: NOTE: Requires PS/2 and one USB port on server. AF604A Server Console Switch (KVM), 0 x 1 x 8 port 336044-B21 Server Console Switch (KVM), 0 x 2 x 16 port 336045-B21 PS/2 Interface Adapter, 1 pack 262588-B21 PS/2 Interface Adapter, 8 pack 262587-B21 NOTE: NOTE: NOTE: NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm . HP 1x4 Console Switch (ALL) AF611A PS2 Server Console Cable, 6 ft, 2 pack AF612A USB Server Console Cable, 6 ft, 2 pack AF613A NOTE: NOTE: NOTE: NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm . HP Serial Console Server HP Serial Console Server HP Serial Console Server HP Serial Console Server Options Options Options Options HP 16 Port Serial Console Server (worldwide) AF101A HP 48 Port Serial Console Server (worldwide) AF102A Serial Adapter, RJ45-DB9 DCE Female, 1 Pack AF103A Serial Adapter, RJ45-DB9 DCE Female, 8 Pack AF110A NOTE: NOTE: NOTE: NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm . NOTE: NOTE: NOTE: NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm . QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 39
Service and Support Service and Support Service and Support Service and Support Offerings Offerings Offerings Offerings (HP Care Pack Services) Hardware Services On-site Service Hardware Services On-site Service Hardware Services On-site Service Hardware Services On-site Service 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic U4528E 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic U4529E Hardware Services 6-Hour Call to Repair On-site Service Hardware Services 6-Hour Call to Repair On-site Service Hardware Services 6-Hour Call to Repair On-site Service Hardware Services 6-Hour Call to Repair On-site Service 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic U4530E Installation & Start-up Services Installation & Start-up Services Installation & Start-up Services Installation & Start-up Services Hardware Installation, Electronic U4538E Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am- 5pm, M-F, excl. HP holidays, Electronic U4539E Support Plus Support Plus Support Plus Support Plus Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic U4540E Support Plus 24 Support Plus 24 Support Plus 24 Support Plus 24 Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic U4541E Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic U6311E Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic U8333E NOTE: NOTE: NOTE: NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack . QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Additional Options DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 40
NOTE: NOTE: NOTE: NOTE: Memory configurations listed do not apply to "Factory Integrated Models". HP ProLiant DL370 G6 Models HP ProLiant DL370 G6 Models HP ProLiant DL370 G6 Models HP ProLiant DL370 G6 Models HP ProLiant ML370 G6 Models HP ProLiant ML370 G6 Models HP ProLiant ML370 G6 Models HP ProLiant ML370 G6 Models DDR3 memory population guidelines DDR3 memory population guidelines DDR3 memory population guidelines DDR3 memory population guidelines For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator Some DIMM installation guidelines are summarized below: For servers with eighteen (18) memory slots: There are three (3) channels per processor; six (6) channels per server There are three (3) DIMM slots for each memory channel; eighteen (18) total slots Memory channel 1 consists of the three (3) DIMMs that are closest to the processor Memory channel 3 consists of the three (3) DIMMs that are furthest from the processor DIMM slots that are white should be populated first Do not mix Unbuffered memory (UDIMMs) with Registered memory (RDIMMs) Do not install DIMMs if the corresponding processor is not installed If only one processor is installed in a 2CPU system, only half of the DIMM slots are available To maximize performance, balance the total memory capacity between all installed processors It is not required, but it is recommended to load the channels similarly if possible You can only have up to eight (8) ranks installed per channel You can only install two quad-rank DIMMs per channel You can only install two UDIMMs per channel; if available, the third slot in the channel must remain empty Populate DIMMs from heaviest load (quad-rank) to lightest load (single-rank) within a channel Heaviest load (DIMM with most ranks) within a channel goes furthest from the chipset For memory mirroring mode, channel 3 must be unpopulated. Channels 1 and 2 are populated identically For lock-step mode, channel 3 must be unpopulated. DIMMs in channels 1 and 2 will be installed in pairs. The paired slots will be 1,4; 2,5; 3;6 on a 3DPC system or 1,4; 2,5; on a 2DPC system No mixing DIMM voltage; all DIMMs must be the same voltage DIMM Type -> Registered Dimms (RDIMMs) Registered Dimms (RDIMMs) Registered Dimms (RDIMMs) Registered Dimms (RDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) DIMM Rank -> Dual Rank (2R) Dual Rank (2R) Dual Rank (2R) Dual Rank (2R) Quad Rank (4R) Quad Rank (4R) Quad Rank (4R) Quad Rank (4R) Single Rank (1R) Single Rank (1R) Single Rank (1R) Single Rank (1R) Dual Rank (2R) Dual Rank (2R) Dual Rank (2R) Dual Rank (2R) DIMM Capacity -> 2GB 4GB 8GB 2GB 4GB 1GB 2GB 1GB 2GB DIMM Native Speed (MHz) -> 1333 1333 1066 * 1066 1333 * * 1333 SLOTS THAT CAN BE POPULATED SLOTS THAT CAN BE POPULATED SLOTS THAT CAN BE POPULATED SLOTS THAT CAN BE POPULATED 18 slot servers 18 18 18 * 12 12 * * 12 MAXIMUM CAPACITY (GB) MAXIMUM CAPACITY (GB) MAXIMUM CAPACITY (GB) MAXIMUM CAPACITY (GB) 18 slot servers 36 72 144 * 48 12 * * 24 POPULATED DIMM SPEED (MHz) POPULATED DIMM SPEED (MHz) POPULATED DIMM SPEED (MHz) POPULATED DIMM SPEED (MHz) 1 DIMM Per Channel 1333 1333 1066 * 1066 1333 * * 1333 2 DIMM Per Channel 1066 1066 1066 * 800 1066 * * 1066 3 DIMM Per Channel 800 800 800 * * * * * * * not supported by HP at this time. NOTES: NOTES: NOTES: NOTES: QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Memory DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 41
Mixing DIMM speeds is allowed, but the system processor speed rules always override the DIMM capabilities If you do mix DIMM speeds, the memory bus will default to the minimum clock rate of all DIMMs in the system - even if the slower DIMM is on the other processor If you install 1x 1066MHz DIMM in channel 1 and 1x 1333MHz DIMM in channel 2, you still run at 1066MHz If you install 1x 1066MHz DIMM in channel 1 and 5x 1333MHz DIMMs with 1 DIMM Per Channel (DPC) in each of the other channels, you run at 1066MHz If you install 3DPC in one channel (if applicable) and 1DPC in all other channels, you run at 800MHz 95 Watt CPU's are required for 1333MHz DIMM speeds. All other CPU's are capable of up to 1066MHz References to the above MHz speeds are for the various speeds of DDR3 DIMMs; 1333 refers to DDR3-1333, etc. DIMM slot and configuration diagrams DIMM slot and configuration diagrams DIMM slot and configuration diagrams DIMM slot and configuration diagrams Basic memory slot & population diagram Basic memory slot & population diagram Basic memory slot & population diagram Basic memory slot & population diagram Population order; start with "A" first, "B" second, "C" third, etc. 18 DIMM SLOTS (9 per CPU node) 18 DIMM SLOTS (9 per CPU node) 18 DIMM SLOTS (9 per CPU node) 18 DIMM SLOTS (9 per CPU node) CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G 1 G Chnl 1 2 D 2 D 3 A 3 A Chnl 2 4 H 4 H Chnl 2 5 E 5 E 6 B 6 B Chnl 3 7 I 7 I Chnl 3 8 F 8 F 9 C 9 C Standard memory configuration (1 CPU model) Standard memory configuration (1 CPU model) Standard memory configuration (1 CPU model) Standard memory configuration (1 CPU model) 6GB, consisting of three (3) 2GB dual-rank PC3-10600 RDIMMs CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G; empty 1 G; empty Chnl 1 2 D; empty 2 D; empty 3 A; 2GB DIMM 3 A; empty Chnl 2 4 H; empty 4 H; empty Chnl 2 5 E; empty 5 E; empty 6 B; 2GB DIMM 6 B; empty Chnl 3 7 I; empty 7 I; empty Chnl 3 8 F; empty 8 F; empty 9 C; 2GB DIMM 9 C; empty QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Memory DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 42
Standard memory plus optional memory (1 CPU model) Standard memory plus optional memory (1 CPU model) Standard memory plus optional memory (1 CPU model) Standard memory plus optional memory (1 CPU model) 54GB, consisting of three (3) 2GB RDIMMs plus six (6) 8GB RDIMMs 3x 2GB dual-rank PC3-10600 RDIMMs 6x 8GB dual-rank PC3-8500 RDIMMs CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G; 8GB DIMM 1 G; empty Chnl 1 2 D; 8GB DIMM 2 D; empty 3 A; 2GB DIMM 3 A; empty Chnl 2 4 H; 8GB DIMM 4 H; empty Chnl 2 5 E; 8GB DIMM 5 E; empty 6 B; 2GB DIMM 6 B; empty Chnl 3 7 I; 8GB DIMM 7 I; empty Chnl 3 8 F; 8GB DIMM 8 F; empty 9 C; 2GB DIMM 9 C; empty Standard memory replaced with optional memory (1 CPU model) Standard memory replaced with optional memory (1 CPU model) Standard memory replaced with optional memory (1 CPU model) Standard memory replaced with optional memory (1 CPU model) RDIMM maximum configuration RDIMM maximum configuration RDIMM maximum configuration RDIMM maximum configuration 72GB, consisting of nine (9) 8GB dual-rank PC3-8500 RDIMMs CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G; 8GB DIMM 1 G; empty Chnl 1 2 D; 8GB DIMM 2 D; empty 3 A; 8GB DIMM 3 A; empty Chnl 2 4 H; 8GB DIMM 4 H; empty Chnl 2 5 E; 8GB DIMM 5 E; empty 6 B; 8GB DIMM 6 B; empty Chnl 3 7 I; 8GB DIMM 7 I; empty Chnl 3 8 F; 8GB DIMM 8 F; empty UDIMM maximum configuration (1 CPU model) UDIMM maximum configuration (1 CPU model) UDIMM maximum configuration (1 CPU model) UDIMM maximum configuration (1 CPU model) 12GB, consisting of six (6) 2GB dual-rank PC3-10600 UDIMMs QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Memory DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 43
CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G; empty 1 G; empty Chnl 1 2 D; 2GB DIMM 2 D; empty 3 A; 2GB DIMM 3 A; empty Chnl 2 4 H; empty 4 H; empty Chnl 2 5 E; 2GB DIMM 5 E; empty 6 B; 2GB DIMM 6 B; empty Chnl 3 7 I; empty 7 I; empty Chnl 3 8 F; 2GB DIMM 8 F; empty 9 C; 2GB DIMM 9 C; empty Standard memory replaced with optional memory (2 CPU model) Standard memory replaced with optional memory (2 CPU model) Standard memory replaced with optional memory (2 CPU model) Standard memory replaced with optional memory (2 CPU model) RDIMM maximum configuration RDIMM maximum configuration RDIMM maximum configuration RDIMM maximum configuration 144GB, consisting of eighteen (18) 8GB PC3-8500 RDIMMs CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G; 8GB DIMM 1 G; 8GB DIMM Chnl 1 2 D; 8GB DIMM 2 D; 8GB DIMM 3 A; 8GB DIMM 3 A; 8GB DIMM Chnl 2 4 H; 8GB DIMM 4 H; 8GB DIMM Chnl 2 5 E; 8GB DIMM 5 E; 8GB DIMM 6 B; 8GB DIMM 6 B; 8GB DIMM Chnl 3 7 I; 8GB DIMM 7 I; 8GB DIMM Chnl 3 8 F; 8GB DIMM 8 F; 8GB DIMM 9 C; 8GB DIMM 9 C; 8GB DIMM UDIMM maximum configuration (2 CPU model) UDIMM maximum configuration (2 CPU model) UDIMM maximum configuration (2 CPU model) UDIMM maximum configuration (2 CPU model) 24GB, consisting of twelve (12) 2GB dual-rank PC3-10600 UDIMMs QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Memory DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 44
CPU1 CPU1 CPU1 CPU1 CPU2 CPU2 CPU2 CPU2 slot # population order slot # population order Chnl 1 1 G; empty 1 G; empty Chnl 1 2 D; 2GB DIMM 2 D; 2GB DIMM 3 A; 2GB DIMM 3 A; 2GB DIMM Chnl 2 4 H; empty 4 H; empty Chnl 2 5 E; 2GB DIMM 5 E; 2GB DIMM 6 B; 2GB DIMM 6 B; 2GB DIMM Chnl 3 7 I; empty 7 I; empty Chnl 3 8 F; 2GB DIMM 8 F; 2GB DIMM 9 C; 2GB DIMM 9 C; 2GB DIMM NOTE: NOTE: NOTE: NOTE: Capacity references are rounded to the common Gigabyte values. 1GB = 1024MB 2GB = 2048MB 4GB = 4096MB 8GB = 8192MB Following are memory options available from HP: Following are memory options available from HP: Following are memory options available from HP: Following are memory options available from HP: Memory Memory Memory Memory Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) Registered DIMMs (RDIMMs) HP 2GB 2Rx8 PC3-10600R-9 Kit 500656-B21 HP 4GB 2Rx4 PC3-10600R-9 Kit 500658-B21 HP 4GB 4Rx8 PC3-8500R-7 LP Kit 500660-B21 HP 8GB 2Rx4 PC3-8500R-7 Kit 516423-B21 Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) Unbuffered with ECC DIMMs (UDIMMs) HP 1GB 1Rx8 PC3-10600E-9 Kit 500668-B21 HP 2GB 2Rx8 PC3-10600E-9 Kit 500670-B21 NOTE: NOTE: NOTE: NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator . NOTE: NOTE: NOTE: NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: http://h18004.www1.hp.com/products/servers/platforms/energyefficient/ QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Memory DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 45
A Removable media bay B (B) SATA DVD-ROM Drive (Standard in all BTO Models) C Optical Drive (blank) 1-8 Eight SFF SAS/SATA HD Bays (Standard in all BTO Models) A Removable media bay B SATA DVD-ROM Drive (Standard in all BTO Models) C Optical Drive (blank) 1-8 Eight SFF SAS/SATA HD Bays (Standard in all BTO Models) 1-24 Twenty-four small form factor (SFF) hot-plug drive bays to support Serial-attached SCSI (SAS) and Serial ATA (SATA) drives with optional drive cages (up to three 8 SFF drive cage can be installed) 1-14 Fourteen large form factor (LFF) hot-plug drive bays to support Serial-attached SCSI (SAS) and Serial ATA (SATA) drives with optional drive cages QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Storage DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 46
Drive Support Drive Support Drive Support Drive Support Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller Removable Media Removable Media Removable Media Removable Media Half-Height SATA DVD- ROM Optical Drive Up to 2 A, B Integrated IDE Half-Height SATA DVD RW Optical Drive Up to 2 A, B Integrated IDE HP Slim SATA DVD-ROM Optical Drive Up to 2 NOTE: NOTE: NOTE: NOTE: Also please use if the 3 drive cage is populated C Integrated IDE HP Slim SATA DVD RW Optical Drive Up to 2 NOTE: NOTE: NOTE: NOTE: Also please use if the 3 drive cage is populated C Integrated IDE Hard Drives Hard Drives Hard Drives Hard Drives NOTE: NOTE: NOTE: NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details. SAS Hot Plug SFF Enterprise (ENT) Drives SAS Hot Plug SFF Enterprise (ENT) Drives SAS Hot Plug SFF Enterprise (ENT) Drives SAS Hot Plug SFF Enterprise (ENT) Drives Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 300GB 6G SAS 10K DP 300GB 3G SAS 10K DP 146GB 6G SAS 10K DP 146GB 3G SAS 10K DP 146GB 3G SAS 15K DP 72GB 3G SAS 10K DP 72GB 3G SAS 15K DP 36GB 3G SAS 15K DP Up to 24 1-8 1-24 HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller SAS Hot Plug 3.5" Enterprise (ENT) Drives SAS Hot Plug 3.5" Enterprise (ENT) Drives SAS Hot Plug 3.5" Enterprise (ENT) Drives SAS Hot Plug 3.5" Enterprise (ENT) Drives Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 450GB 3G SAS 15K DP 400GB 3G SAS 10K DP 146GB 3G SAS 15K DP 72GB 3G SAS 15K DP Up to 14 1-14 HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Storage DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 47
SAS Hot Plug 3.5" Midline (MDL) Drives SAS Hot Plug 3.5" Midline (MDL) Drives SAS Hot Plug 3.5" Midline (MDL) Drives SAS Hot Plug 3.5" Midline (MDL) Drives Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 1TB 3G SAS 7.2K DP 750GB 3G SAS 7.2K DP Up to 14 1-14 HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller SATA Hot Plug SFF Entry (ETY) Drives SATA Hot Plug SFF Entry (ETY) Drives SATA Hot Plug SFF Entry (ETY) Drives SATA Hot Plug SFF Entry (ETY) Drives Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 250GB 3G SATA 5.4K 120GB 1.5G SATA 5.4K Up to 24 1-8 1-24 HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller SATA Hot Plug 3.5" Midline (MDL) Drives SATA Hot Plug 3.5" Midline (MDL) Drives SATA Hot Plug 3.5" Midline (MDL) Drives SATA Hot Plug 3.5" Midline (MDL) Drives Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 1TB 3G SATA 7.2K 750GB 3G SATA 7.2K 500GB 3G SATA 7.2K 250GB 3G SATA 7.2K Up to 14 1-14 HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Storage DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 48
External Storage External Storage External Storage External Storage Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Host Controller or Adapter Host Controller or Adapter Host Controller or Adapter Host Controller or Adapter 50 Modular Smart Array Up to 4 External HP Smart Array P800/512 BBWC Controller 60 Modular Smart Array Up to 4 External HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller Up to 8 HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller 70 Modular Smart Array Up to 2 External HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller Up to 4 HP Smart Array P800/512 BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller Tape and Disk-Based Backup Tape and Disk-Based Backup Tape and Disk-Based Backup Tape and Disk-Based Backup NOTE: NOTE: NOTE: NOTE: For a complete listing of compatible tape and disk-based backup offerings, please visit: www.hp.com/go/connect . Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller Part Number Part Number Part Number Part Number Internal USB Tape Drives Internal USB Tape Drives Internal USB Tape Drives Internal USB Tape Drives DAT 40 USB DAT 72 USB DAT 160 USB B,C USB 2.0 Port N/A USB Tape Drives, External USB Tape Drives, External USB Tape Drives, External USB Tape Drives, External DAT 40 USB DAT 72 USB DAT 160 USB 1U Rack-Mount Kit External USB 2.0 Port N/A SAS Tape Drives, Internal SAS Tape Drives, Internal SAS Tape Drives, Internal SAS Tape Drives, Internal DAT 160 SAS LTO-2 Ultrium 448 SAS LTO-3 Ultrium 920 SAS LTO-4 Ultrium 1760 SAS B,C HP Smart Array P212/Zero Memory Controller 462828-B21 SAS Tape Drives, Internal SAS Tape Drives, Internal SAS Tape Drives, Internal SAS Tape Drives, Internal LTO-4 Ultrium 1840 SAS B C HP Smart Array P212/Zero Memory Controller 462828-B21 SAS Tape Drives, External SAS Tape Drives, External SAS Tape Drives, External SAS Tape Drives, External DAT 160 SAS LTO-2 Ultrium 448 SAS LTO-3 Ultrium 920 SAS LTO-4 Ultrium 1760 SAS LTO-4 Ultrium 1840 SAS 1U Rack-Mount 3U Rack-Mount External HP Smart Array P212/Zero Memory Controller 462828-B21 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Storage DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 49
SAS Tape Automation, SAS Tape Automation, SAS Tape Automation, SAS Tape Automation, External External External External 1/8 G2 Autoloader MSL2024 MSL4048 MSL8096 External HP Smart Array P212/Zero Memory Controller 462828-B21 Fibre Tape Automation, Fibre Tape Automation, Fibre Tape Automation, Fibre Tape Automation, External External External External MSL2024 MSL4048 MSL8096 MSL6000 External Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs for detailed connectivity information. N/A HP StorageWorks RDX HP StorageWorks RDX HP StorageWorks RDX HP StorageWorks RDX Removable Disk Backup Removable Disk Backup Removable Disk Backup Removable Disk Backup System, Internal System, Internal System, Internal System, Internal RDX160 RDX320 RDX500 B,C USB 2.0 Port N/A HP StorageWorks RDX HP StorageWorks RDX HP StorageWorks RDX HP StorageWorks RDX Removable Disk Backup Removable Disk Backup Removable Disk Backup Removable Disk Backup System, External System, External System, External System, External RDX160 RDX320 RDX500 External USB 2.0 Port N/A HP StorageWorks D2D HP StorageWorks D2D HP StorageWorks D2D HP StorageWorks D2D Backup Systems Backup Systems Backup Systems Backup Systems D2D120 D2D130 D2D2503i D2D4004i External Embedded Network Controller N/A QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Storage DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 50
HP 460W Power Supply HP 460W Power Supply HP 460W Power Supply HP 460W Power Supply Part Number - AC 460W PSU Part Number - AC 460W PSU Part Number - AC 460W PSU Part Number - AC 460W PSU 503296-B21 Input Voltage Range (Vrms) Input Voltage Range (Vrms) Input Voltage Range (Vrms) Input Voltage Range (Vrms) 100 to 240 Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) 50/60 Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) 100 100 100 100 120 120 120 120 208 208 208 208 200 200 200 200 220 220 220 220 230 230 230 230 240 240 240 240 Maximum Rated Output Wattage 460 460 460 460 460 460 460 Nominal Input Current (A rms) 5.5 4.5 2.6 2.5 2.4 2.3 2.2 Max Rated Input Wattage Rating (Watts) 526 520 505 505 503 503 503 Max. Rated VA (Volt-Amp) 548 542 527 527 524 524 524 Efficiency (%) at Max. Rated Output Wattage 87.5 88.5 91 91 91.5 91.5 91.5 Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97 Leakage Current (mA) 0.42 0.50 0.83 0.87 0.92 0.96 1.00 Max. Inrush Current (A peak) 30 30 30 30 30 30 30 Max. Inrush Current duration (mS) 20 20 20 20 20 20 20 Maximum British Thermal Unit Rating (BTU-Hr) 1794 1773 1725 1725 1715 1715 1715 HP 750W Power Supply HP 750W Power Supply HP 750W Power Supply HP 750W Power Supply Part Number - AC 750W PSU Part Number - AC 750W PSU Part Number - AC 750W PSU Part Number - AC 750W PSU 512327-B21 Input Voltage Range (Vrms) Input Voltage Range (Vrms) Input Voltage Range (Vrms) Input Voltage Range (Vrms) 100 to 240 Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) 50/60 Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) 100 100 100 100 120 120 120 120 208 208 208 208 200 200 200 200 220 220 220 220 230 230 230 230 240 240 240 240 Maximum Rated Output Wattage 750 750 750 750 750 750 750 Nominal Input Current (A rms) 8.9 7.4 4.3 4.1 3.9 3.7 3.6 Max Rated Input Wattage Rating (Watts) 857 847 824 825 820 820 820 Max. Rated VA (Volt-Amp) 894 884 859 859 854 854 854 Efficiency (%) at Max. Rated Output Wattage 87.5 88.5 91 91 91.5 91.5 91.5 Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97 Leakage Current (mA) 0.42 0.50 0.83 0.87 0.92 0.96 1.00 Max. Inrush Current (A peak) 30 30 30 30 30 30 30 Max. Inrush Current duration (mS) 20 20 20 20 20 20 20 Maximum British Thermal Unit Rating (BTU-Hr) 2925 2892 2812 2812 2797 2797 2797 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Power Specifications DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 51
HP 1200W Power Supply HP 1200W Power Supply HP 1200W Power Supply HP 1200W Power Supply Part Number - AC Part Number - AC Part Number - AC Part Number - AC 500172-B21 Operational Input Voltage Range Operational Input Voltage Range Operational Input Voltage Range Operational Input Voltage Range (Vrms) (Vrms) (Vrms) (Vrms) 100 to 240 Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) Frequency Range (Nominal) (Hz) 50/60 Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) Nominal Input Voltage (Vrms) 100 100 100 100 120 120 120 120 208 208 208 208 200 200 200 200 220 220 220 220 230 230 230 230 240 240 240 240 Maximum Rated Output Wattage 800 900 1200 1200 1200 1200 1200 Nominal Input Current (A rms) 9.7 9.0 7.0 6.8 6.4 9.1 5.9 Max Rated Input Wattage Rating (Watts) 930 1034 1348 1348 1348 1348 1348 Max. Rated VA (Volt-Amp) 970 1079 1406 1406 1406 1406 1406 Efficiency (%) at Max. Rated Output Wattage 86 87 89 89 89 89 89 Power Factor 0.97 0.97 0.97 0.97 0.97 0.97 0.97 Leakage Current (mA) 0.42 0.50 0.83 0.87 0.92 0.96 1.00 Max. Inrush Current (A peak) 30 30 30 30 30 30 30 Max. Inrush Current duration (mS) 20 20 20 20 20 20 20 Maximum British Thermal Unit Rating (BTU-Hr) 3174 3530 4600 4600 4600 4600 4600 To review typical system power ratings use the Active Answers HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor To drill down to calculators: - Click on: "ProLiant Servers" - Click on the Server of interest. Example: DL370 G6 or ML370 G6 - Click on: "Power Calculator" link. (You may need to scroll down to see it) QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Power Specifications DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 52
System Unit System Unit System Unit System Unit Tower Dimensions Tower Dimensions Tower Dimensions Tower Dimensions (H x W x D) (with bezel) 18.52 x 9.75 x 29.12 in (47.04 x 24.77 x 73..96 cm) Rack Dimensions Rack Dimensions Rack Dimensions Rack Dimensions (H x W x D) (with bezel) 6.88 x 19.03 x 27.53 in (17.48 x 48.34 x 69.93 cm) Tower Weight Tower Weight Tower Weight Tower Weight (approximate) Maximum (two hard drives, power supply, and processor installed) 103.06 lbs (46.75 kg) Minimum (one hard drive, power supply, and processor installed) 66,14 lbs (30.00 kg) Rack Weight Rack Weight Rack Weight Rack Weight (approximate) Maximum (two hard drives, power supply, and processor installed) 103.06 lbs (46,75 kg) Minimum (one hard drive, power supply, and processor installed) 55.12 lbs (25.00 kg) Input Requirements Input Requirements Input Requirements Input Requirements (per power supply) Rated Line Voltage 90 - 132 VAC, 180 - 264 VAC Rated Input Current 7.5A (at 100 VAC), 3.8A (at 200 VAC) Rated Input Frequency 47 to 63 Hz Rated Input Power 980W (at 100 VAC) 1035W (at 120 VAC) 1170W (at 240 VAC) BTU Rating BTU Rating BTU Rating BTU Rating Maximum 460W - 1773 BTU / hr (at 120 VAC), 1715 (at 240 VAC) 750W - 2892 BTU / hr (at 120 VAC), 2797 (at 240 VAC) 1200W - 3530 BTU / hr (at 120 VAC), 4600 (at 240 VAC) Power Specifications Power Specifications Power Specifications Power Specifications To review typical system power ratings use the HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant- energy-efficient - Click on the system of interest. Example: DL370 G6 or ML370 G6 - Follow the instructions of the next screens. Power Supply Output Power Supply Output Power Supply Output Power Supply Output (per power supply) Rated Steady-State Power 460 W (at 100 VAC) Maximum Peak Power 460 W (at 200 VAC) 460 W (at 100 VAC) 460 W (at 200 VAC) NOTE: NOTE: NOTE: NOTE: See Power Supply Specifications tables for complete details on 460W PSU and optional 750W and 1200W Power Supply Options. System Inlet Temperature System Inlet Temperature System Inlet Temperature System Inlet Temperature Operating 10° to 35°C (50° to 95°F) at sea level with an QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Technical Specifications DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 53
altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). Non-operating -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). Relative Humidity Relative Humidity Relative Humidity Relative Humidity (non-condensing) Operating 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non- condensing. Non-operating 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non- condensing. Altitude Altitude Altitude Altitude Operating 3048 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). Non-operating 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). Acoustic Noise Acoustic Noise Acoustic Noise Acoustic Noise Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). Idle Idle Idle Idle L WAd 5.6 B for 1P Non-Redundant; 5.5 B for 2P Redundant L pAm 39 dB for 1P Non-Redundant; 39 dB for 2P Redundant Operating Operating Operating Operating L WAd 5.6 B for 1P Non-Redundant; 5.5 B for 2P Redundant L pAm 39 dB for 1P Non-Redundant; 39 dB for 2P Redundant NOTE: NOTE: NOTE: NOTE: The Listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels. Emissions Classification Emissions Classification Emissions Classification Emissions Classification (EMC) FCC Rating Class B Normative Standards CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Technical Specifications DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 54
NOTE: NOTE: NOTE: NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements. Smart Array P410i Smart Array P410i Smart Array P410i Smart Array P410i Controller Controller Controller Controller Dimensions Dimensions Dimensions Dimensions (not including bracket) Low Profile PCIe Form Factor 7.5 in x 9.5 in x 2.25 in (19.05 cm x 24.13 cm x 5.72 cm) Disk Drive and Enclosure Disk Drive and Enclosure Disk Drive and Enclosure Disk Drive and Enclosure Interface - Transfer rate Interface - Transfer rate Interface - Transfer rate Interface - Transfer rate 3G SAS (Serial Attached SCSI)/6G SAS Capable 1.5G SATA (Serial ATA)/3G SATA Capable SAS Connectors SAS Connectors SAS Connectors SAS Connectors 2 internal (Mini-SAS) x8 wide port connectors Cache Memory Speed Cache Memory Speed Cache Memory Speed Cache Memory Speed DDR2-800MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth. Server Interface Server Interface Server Interface Server Interface x8 5G PCIe 2.0 provides 4GB/s maximum bandwidth SAS Speed SAS Speed SAS Speed SAS Speed x8 3G SAS provides 2.4GB/s maximum bandwidth Cache Memory Cache Memory Cache Memory Cache Memory 40-bit 256MB ECC protected cache (72-bit 512MB BBWC module upgrades available); transportable with battery-backed upgrade Logical Drives Supported Logical Drives Supported Logical Drives Supported Logical Drives Supported Up to 12 logical drives Maximum Logical Drive Maximum Logical Drive Maximum Logical Drive Maximum Logical Drive Capacity Capacity Capacity Capacity Greater than 2TB Host Memory Addressing Host Memory Addressing Host Memory Addressing Host Memory Addressing 64-bit, supporting greater than 4GB server memory space RAID Support RAID Support RAID Support RAID Support RAID 6, 6 0 (Advanced Data Guarding) NOTE: NOTE: NOTE: NOTE: The minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade is required to enable RAID 6, 6 0 RAID 5, 5 0 (Distributed Data Guarding) NOTE: NOTE: NOTE: NOTE: The 256 MB & Battery Kit upgrade is required to enable RAID 5, 5 0 support of the Smart Array P410i RAID 1 0 (Striping & Mirroring) RAID 0 (Striping) Upgradeable Firmware Upgradeable Firmware Upgradeable Firmware Upgradeable Firmware Upgradeable Firmware with recovery ROM feature QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Technical Specifications DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 55
NC375i Integrated Quad NC375i Integrated Quad NC375i Integrated Quad NC375i Integrated Quad Port Multifunction Gigabit Port Multifunction Gigabit Port Multifunction Gigabit Port Multifunction Gigabit Server Adapter Server Adapter Server Adapter Server Adapter Network Interface Network Interface Network Interface Network Interface 10Base-T/100Base-TX/1000Base-TX Compatibility Compatibility Compatibility Compatibility IEEE 802.3 10Base-T IEEE 802.3ab 1000Base-T IEEE 802.3u 100Base-TX IEEE 802.3ad 1000Base-TX IEEE 802.1p 100Base-TX IEEE 802.1q 100Base-TX Data Transfer Method Data Transfer Method Data Transfer Method Data Transfer Method PCI Express, four lanes (x4) Network Transfer Rate Network Transfer Rate Network Transfer Rate Network Transfer Rate 10Base-T (Half-Duplex) 10 Mb/s 10Base-T (Full-Duplex) 20 Mb/s 100Base-TX (Half-Duplex) 100 Mb/s 100Base-TX (Full-Duplex) 200 Mb/s 1000Base-TX (Half and Full-Duplex) 2000 Mb/s Connector Connector Connector Connector RJ-45 Cable Support Cable Support Cable Support Cable Support 10Base-T Categories 3, 4 or 5 UTP up to 328 ft (100 m) 100Base-TX Category 5 or higher UTP; up to 328 ft (100 m) 1000Base-TX Category 5 or higher UTP; up to 328 ft (100 m) Environment-friendly Environment-friendly Environment-friendly Environment-friendly Products and Approach Products and Approach Products and Approach Products and Approach End-of-life Management End-of-life Management End-of-life Management End-of-life Management and Recycling and Recycling and Recycling and Recycling Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green . To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green . These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. © Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and other countries. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less. QuickSpecs HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant DL370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) HP ProLiant ML370 Generation 6 (G6) Technical Specifications DA - 13242 Worldwide â Version 3 â April 2, 2009 Page 56